Abstract:
OBJECTIVE:To evaluate the safety of in-home use of the MiniMed™ 670G system with SmartGuard™ technology in children with type 1 diabetes (T1D). METHODS:Participants (N = 105, ages 7-13 years, mean age 10.8 ± 1.8 years) were enrolled at nine centers (eight in the United States and one in Israel) and completed a 2-week baseline run-in phase in Manual Mode followed by a 3-month study phase with Auto Mode enabled. Sensor glucose (SG), glycated hemoglobin (HbA1c), percentage of SG values across glucose ranges, and SG variability, during the run-in and study phases were compared. Participants underwent frequent sample testing with i-STAT® venous reference measurement during a hotel period (6 days/5 nights) to evaluate the system's continuous glucose monitoring performance. RESULTS:Auto Mode was used a median of 81% of the time. From baseline to end of study, overall SG dropped by 6.9 ± 17.2 mg/dL (P < 0.001), HbA1c decreased from 7.9% ± 0.8% to 7.5% ± 0.6% (P < 0.001), percentage of time in target glucose range (70-180 mg/dL) increased from 56.2% ± 11.4% to 65.0% ± 7.7% (P < 0.001), and the SG coefficient of variation decreased from 39.6% ± 5.4% to 38.5% ± 3.8% (P = 0.009). The percentage of SG values within target glucose range was 68.2% ± 9.1% and that of i-STAT reference values was 65.6% ± 17.7%. The percentage of values within 20%/20 of the i-STAT reference was 85.2%. There were no episodes of severe hypoglycemia or diabetic ketoacidosis during the study phase. CONCLUSION:In-home use of MiniMed 670G system Auto Mode for 3 months by children with T1D, similar to MiniMed 670G system use by adolescents and adults with T1D, was safe and associated with reduced HbA1c levels and increased time in target glucose range, compared with baseline.
journal_name
Diabetes Technol Therjournal_title
Diabetes technology & therapeuticsauthors
Forlenza GP,Pinhas-Hamiel O,Liljenquist DR,Shulman DI,Bailey TS,Bode BW,Wood MA,Buckingham BA,Kaiserman KB,Shin J,Huang S,Lee SW,Kaufman FRdoi
10.1089/dia.2018.0264subject
Has Abstractpub_date
2019-01-01 00:00:00pages
11-19issue
1eissn
1520-9156issn
1557-8593journal_volume
21pub_type
杂志文章abstract::Hyperspectral imaging (HSI) has been useful in monitoring several medical conditions, which to date have generally involved local changes in skin oxygenation of isolated regions of interest such as skin flaps or small burns. Here, by contrast, we present a study in which HSI was used to assess the local cutaneous mani...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/152091503322527058
更新日期:2003-01-01 00:00:00
abstract:BACKGROUND:Visual disabilities due to diabetes are on the rise, especially in urban areas of developing countries. Proper health planning will need evidence-based information. STUDY DESIGN AND METHODS:We estimated the prevalence and identified the determinants of eye complications among persons with diabetes screened ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2009.0033
更新日期:2009-09-01 00:00:00
abstract:BACKGROUND:The purpose of this study was to evaluate the performance of an insulin infusion protocol targeting a blood glucose (BG) level of 140-180 mg/dL and to characterize protocol adherence. MATERIALS AND METHODS:This was a retrospective observational cohort study including patients for whom the protocol was order...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2015.0046
更新日期:2016-02-01 00:00:00
abstract:BACKGROUND:Stress-induced hyperglycemia is prevalent in critical care, even in patients with no history of diabetes. Increased counter-regulatory hormone response increases gluconeogenesis and effective insulin resistance, which can be exacerbated by drug therapy. Control of blood glucose levels to the 4.0-6.1 mmol/L r...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2006.8.449
更新日期:2006-08-01 00:00:00
abstract:BACKGROUND:Continuous subcutaneous insulin infusion (CSII) is an effective method of insulin substitution with increased risk of hypoglycemia and diabetic ketoacidosis (DKA) in rare situations. The lack of subcutaneous long-acting insulin and short half-life of serum insulin increases the risk of ketosis and DKA follow...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2008.0124
更新日期:2009-08-01 00:00:00
abstract:UNLABELLED:Abstract Objective: Controlled inpatient studies on the effects of food, physical activity (PA), and insulin dosing on glucose excursions exist, but such outpatient data are limited. We report here outpatient data on glucose excursions and its key determinants over 5 days in 30 adolescents with type 1 diab...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2012.0053
更新日期:2012-08-01 00:00:00
abstract:BACKGROUND:Prediction of glycemic profile is an important task for both early recognition of hypoglycemia and enhancement of the control algorithms for optimization of insulin infusion rate. Adaptive models for glucose prediction and recognition of hypoglycemia based on statistical and artificial intelligence technique...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2011.0093
更新日期:2012-02-01 00:00:00
abstract:BACKGROUND:We aimed to assess the effect of continuous subcutaneous insulin infusion (CSII) therapy in patients with "recalcitrant diabetes" whose glycemia had not been controlled adequately with multiple daily injections of insulin or insulin plus oral hypoglycemic agents. PATIENTS AND METHODS:We retrospectively anal...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2009.0066
更新日期:2009-11-01 00:00:00
abstract::Current clinical guidelines for diabetes care encourage self-monitoring of blood glucose (SMBG) to improve glycemic control. Specific protocols remain variable, however, particularly among non-insulin-using patients. This is due in part to efficacy studies that neglect to consider (1) the performance of monitoring equ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2008.0104
更新日期:2008-12-01 00:00:00
abstract:BACKGROUND:Glucose variability (GV) has been increasingly (or more extensively) studied in patients with type 1 diabetes (T1D) in the ambulatory setting; limited data exist on GV in hospitalized patients with T1D. MATERIALS AND METHODS:Retrospective single center cohort study, we analyzed in-hospital glucose measureme...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2017.0107
更新日期:2017-10-01 00:00:00
abstract:BACKGROUND:Continuous glucose monitoring (CGM) technologies report measurements of interstitial glucose concentration every 5 min. CGM technologies have the potential to be utilized for prediction of prospective glucose concentrations with subsequent optimization of glycemic control. This article outlines a feed-forwar...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2010.0104
更新日期:2011-02-01 00:00:00
abstract:OBJECTIVE:This study was designed to assess whether waist circumference can predict metabolic syndrome abnormalities in primary schoolchildren. RESEARCH DESIGN AND METHODS:Of 5,103 children (2,526 males) 4-13 years old who underwent anthropometric measurements, 530 had more extensive testing. Body mass index (BMI), wa...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究
doi:10.1089/dia.2006.0017
更新日期:2007-04-01 00:00:00
abstract:BACKGROUND:The OpT2mise randomized trial was designed to compare the effects of continuous subcutaneous insulin infusion (CSII) and multiple daily injections (MDI) on glucose profiles in patients with type 2 diabetes. RESEARCH DESIGN AND METHODS:Patients with glycated hemoglobin (HbA1c) levels of ≥8% (64 mmol/mol) and...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2015.0159
更新日期:2016-01-01 00:00:00
abstract:BACKGROUND:Balance is sensed through peripheral and central receptors and mediated by central control through the brain and spinal cord. Although some evidence exists as to the areas of the brain involved and how processing of data occurs in young individuals, nothing has been published on people with diabetes. The pur...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2012.0152
更新日期:2012-11-01 00:00:00
abstract::Glucose oxidase has had a central role in previous glucose sensing methods and is key to the development of certain new glucose sensors. The immobilized enzyme is specific for glucose and sufficiently long-lived for many sensor applications, but new glucose sensing applications may place increased demands on the enzym...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/15209150050194242
更新日期:2000-10-01 00:00:00
abstract:: Background: The objective of this study was to assess the safety and performance of the Omnipod® personalized model predictive control (MPC) algorithm in adults, adolescents, and children aged ≥6 years with type 1 diabetes (T1D) under free-living conditions using an invest...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章,多中心研究
doi:10.1089/dia.2019.0286
更新日期:2020-03-01 00:00:00
abstract:BACKGROUND:Diabetic foot ulcer area is a basic parameter used for monitoring the wound healing and effectiveness of the treatment applied. TeleDiaFoS (developed earlier in collaboration with the Department and Clinic of Gastroenterology and Metabolic Diseases, Medical University of Warsaw, Warsaw, Poland) is one of jus...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2011.0082
更新日期:2011-11-01 00:00:00
abstract:BACKGROUND:Previous studies of aerobic exercise have found lower sensor accuracy during exercise. Whether or not resistance exercise would also be associated with lower sensor accuracy has not yet been examined. This study sought to investigate the accuracy of continuous glucose monitoring sensor values at rest, during...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2012.0182
更新日期:2013-01-01 00:00:00
abstract:BACKGROUND:Microneedles have previously been used to deliver insulin to animal models, but not in human subjects. This study tested the hypothesis that hollow microneedles can deliver insulin to modulate blood glucose levels in subjects with type 1 diabetes in a minimally invasive manner. METHODS:This study was carrie...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2008.0103
更新日期:2009-06-01 00:00:00
abstract:BACKGROUND:Real-time continuous glucose monitoring (CGM) was studied in 140 adults with diabetes over a 12-week period of home use. Hemoglobin A(1c)(HbA1c) was measured on day 1 (baseline) and at weeks 6 and 12. METHODS:On day 1, participants received the CGM device (STS(R) System, DexCom, Inc., San Diego, CA) and und...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章,多中心研究
doi:10.1089/dia.2007.0205
更新日期:2007-06-01 00:00:00
abstract:BACKGROUND:The objective of this investigation was to evaluate the test-retest repeatability of insulin sensitivity and secretion indices derived from liquid meal tolerance tests (MTTs) in subjects with normal fasting glucose (NFG) (n = 20), impaired fasting glucose (IFG) (n = 20), or type 2 diabetes mellitus (n = 38)....
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2010.0083
更新日期:2010-11-01 00:00:00
abstract:BACKGROUND:Continuous glucose monitoring (CGM) has been shown to improve glycemic control and reduce hypoglycemia with consistent use. Youth, however, are unlikely to use CGM consistently. We compared psychological characteristics of youth with type 1 diabetes, their parents, and adults with type 1 diabetes randomized ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2011.0201
更新日期:2012-06-01 00:00:00
abstract:AIMS:This study compared glycemic control and maternal and fetal outcomes in pregnant women with type 1 diabetes mellitus (T1DM) treated with multiple daily injections (MDI) or continuous subcutaneous insulin infusion (CSII) using regular (RI) or lispro (LP) insulin. METHODS:Three hundred fifteen consecutive singleton...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2010.0111
更新日期:2010-12-01 00:00:00
abstract::With the expiration of patent protection for several originator insulin analog molecules, the availability of insulin analog copies is set to increase. Many regulatory authorities have developed, and continue to refine, guidelines for the approval of biosimilar insulin analogs. Aspects such as the structure, pharmacok...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2016.0263
更新日期:2017-02-01 00:00:00
abstract::The Editor of Diabetes Technology & Therapeutics is officially retracting the article entitled, "No Deleterious Effect of Lockdown Due to COVID-19 Pandemic on Glycaemic Control, Measured by Glucose Monitoring, in Adults with Type 1 Diabetes," by Beato-Vibora PI. Diabetes Technol Ther 2020; epub DOI: 10.1089/dia.2020.0...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,收录出版
doi:10.1089/dia.2020.0184
更新日期:2020-05-12 00:00:00
abstract::Patients with diabetes play with a double-edged sword when it comes to deciding glucose and A1c target levels. On the one side, tight control has been shown to be crucial in avoiding long-term complications; on the other, tighter control leads to an increased risk of iatrogenic hypoglycemia, which is compounded when h...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2005.7.3
更新日期:2005-02-01 00:00:00
abstract::There is a clear role for inflammation in the development of type 2 diabetes and its associated co-morbidities. Circulating inflammatory markers such as C-reactive protein, sialic acid, and interleukin- 6 are all significant independent predictors of disease. A number of nutritional components are hypothesized to modu...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2006.8.45
更新日期:2006-02-01 00:00:00
abstract:AIMS:This study evaluated treatment satisfaction, comfort, and function using the wireless OmniPod™ Insulin Management System (Insulet Corp., Bedford, MA) compared with conventional (infusion set) insulin pumps in young adults with type 1 diabetes. RESEARCH DESIGN AND METHODS:Twenty-nine patients (age, 24.0 ± 5.1 year...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2011.0228
更新日期:2012-05-01 00:00:00
abstract:: Objective: To assess the degree, duration, mean absolute relative difference (MARD), and error analysis of discrepant values per continuous glucose monitoring (CGM) systems after hydroxyurea (HU) administration. Research Design and Methods: ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2020.0490
更新日期:2020-12-30 00:00:00
abstract:BACKGROUND:Weight gain often occurs when insulin therapy is initiated. The long-acting insulin analog insulin detemir has been shown to be effective and well tolerated when used in basal-bolus regimens or as an add-on to oral antidiabetic drugs (OADs) and causes less weight gain than other insulins. The aim of this exp...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1089/dia.2008.0282