Abstract:
: Background: The objective of this study was to assess the safety and performance of the Omnipod® personalized model predictive control (MPC) algorithm in adults, adolescents, and children aged ≥6 years with type 1 diabetes (T1D) under free-living conditions using an investigational device. Materials and Methods: A 96-h hybrid closed-loop (HCL) study was conducted in a supervised hotel/rental home setting following a 7-day outpatient standard therapy (ST) phase. Eligible participants were aged 6-65 years with A1C <10.0% using insulin pump therapy or multiple daily injections. Meals during HCL were unrestricted, with boluses administered per usual routine. There was daily physical activity. The primary endpoints were percentage of time with sensor glucose <70 and ≥250 mg/dL. Results: Participants were 11 adults, 10 adolescents, and 15 children aged (mean ± standard deviation) 28.8 ± 7.9, 14.3 ± 1.3, and 9.9 ± 1.0 years, respectively. Percentage time ≥250 mg/dL during HCL was 4.5% ± 4.2%, 3.5% ± 5.0%, and 8.6% ± 8.8% per respective age group, a 1.6-, 3.4-, and 2.0-fold reduction compared to ST (P = 0.1, P = 0.02, and P = 0.03). Percentage time <70 mg/dL during HCL was 1.9% ± 1.3%, 2.5% ± 2.0%, and 2.2% ± 1.9%, a statistically significant decrease in adults when compared to ST (P = 0.005, P = 0.3, and P = 0.3). Percentage time 70-180 mg/dL increased during HCL compared to ST, reaching significance for adolescents and children: HCL 73.7% ± 7.5% vs. ST 68.0% ± 15.6% for adults (P = 0.08), HCL 79.0% ± 12.6% vs. ST 60.6% ± 13.4% for adolescents (P = 0.01), and HCL 69.2% ± 13.5% vs. ST 54.9% ± 12.9% for children (P = 0.003). Conclusions: The Omnipod personalized MPC algorithm was safe and performed well over 5 days and 4 nights of use by a cohort of participants ranging from youth aged ≥6 years to adults with T1D under supervised free-living conditions with challenges, including daily physical activity and unrestricted meals.
journal_name
Diabetes Technol Therjournal_title
Diabetes technology & therapeuticsauthors
Sherr JL,Buckingham BA,Forlenza GP,Galderisi A,Ekhlaspour L,Wadwa RP,Carria L,Hsu L,Berget C,Peyser TA,Lee JB,O'Connor J,Dumais B,Huyett LM,Layne JE,Ly TTdoi
10.1089/dia.2019.0286subject
Has Abstractpub_date
2020-03-01 00:00:00pages
174-184issue
3eissn
1520-9156issn
1557-8593journal_volume
22pub_type
临床试验,杂志文章,多中心研究abstract:BACKGROUND:Vascular endothelial growth factor (VEGF) is involved in the pathogenesis of diabetic microvascular disease. Most diabetes patients have higher serum levels of ferritin that may participate in diabetic vascular complications through high oxidative stress induced by iron. However, the mechanistic link between...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2013.0181
更新日期:2014-04-01 00:00:00
abstract:BACKGROUND:Diabetic foot ulcer area is a basic parameter used for monitoring the wound healing and effectiveness of the treatment applied. TeleDiaFoS (developed earlier in collaboration with the Department and Clinic of Gastroenterology and Metabolic Diseases, Medical University of Warsaw, Warsaw, Poland) is one of jus...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2011.0082
更新日期:2011-11-01 00:00:00
abstract::Innovo (Novo Nordisk A/S, Hillerød, Denmark) is a new insulin injection system that offers built-in memory and a large, clear display to provide patients with more control during insulin injections. The aim of this trial was to compare the efficacy and safety of Innovo and NovoPen 3 (Novo Nordisk A/S) in patients expe...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章,多中心研究,随机对照试验
doi:10.1089/152091504322783413
更新日期:2004-02-01 00:00:00
abstract:BACKGROUND AND OBJECTIVE:Hyperglycemia occurs commonly in patients admitted to medical intensive care units (MICUs). Whether real-time (RT) continuous glucose monitoring (CGM) improves glycemic control and variability and reduces hypoglycemia in severely ill MICU patients with an Acute Physiology and Chronic Health Eva...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1089/dia.2015.0151
更新日期:2015-12-01 00:00:00
abstract::The transplantation of microencapsulated islets may allow reversal of hyperglycemia in the absence of immunosuppression. Poly-L-lysine (PLL) on capsules may potentiate the fibrotic reaction against implanted capsules. The aims of this study were to investigate how the biocompatibility of such capsules affects their fu...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/152091503322250677
更新日期:2003-01-01 00:00:00
abstract:BACKGROUND:Accurate and economic detection of nerve damage in diabetes is key to more widespread diagnosis of patients with diabetic peripheral neuropathy (DPN) and painful diabetic neuropathy. This study examined the diagnostic performance of NerveCheck, an inexpensive ($500) quantitative sensory testing (QST) device....
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2016.0279
更新日期:2016-12-01 00:00:00
abstract:BACKGROUND:Proper healing of ulcers and wounds on the feet of diabetes patients is important in order to prevent amputation. If the wound area reduction during the first 4 weeks of the treatment is not 40% or more, reevaluation of the treatment is necessary. The wound area evaluation is not complicated when the patient...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2011.0004
更新日期:2011-08-01 00:00:00
abstract:BACKGROUND:Continuous glucose monitoring is a useful tool for the achievement of improved glucose control in patients with diabetes. We tested the ability of a novel noninvasive continuous glucose monitor to track glucose excursions. METHODS:The novel noninvasive Aprise sensor (Glucon Inc., Boulder, CO) utilizes the p...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章
doi:10.1089/dia.2006.0059
更新日期:2007-02-01 00:00:00
abstract::Diabetic nephropathy is one of the major causes of end-stage renal disease and is often associated with other macrovascular complications such as ischemic heart disease and peripheral vascular disease. Angiotensin converting enzyme inhibitors (ACE-I) and angiotensin II receptor blockers (AIIR) have both been shown to ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/152091502760098456
更新日期:2002-01-01 00:00:00
abstract:PURPOSE:This study investigated reasons for the rejection and discontinuation of insulin pump therapy and explored general attitudes towards this mode of therapy among young patients with type 1 diabetes. METHODS:A questionnaire was developed using a focus group of young people with diabetes. It was then used to surve...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2009.0080
更新日期:2010-01-01 00:00:00
abstract:: Background: The prevalence of diabetes in youth is increasing worldwide in parallel with the obesity epidemic. This study aimed to determine the incidence rates of dysglycemia (diabetes or prediabetes) and evaluate the predictors of its progression or regression to normal ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2020.0109
更新日期:2020-12-01 00:00:00
abstract:OBJECTIVE:this study assessed patient-related factors associated with persistence and resumption of using pens as insulin delivery devices. METHODS:patients (n = 549; 300 current pen users, 249 former pen users) were recruited from national panels to participate in computer-assisted telephone interviews. Measures incl...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2010.0128
更新日期:2011-01-01 00:00:00
abstract:OBJECTIVE:This study was designed to assess whether waist circumference can predict metabolic syndrome abnormalities in primary schoolchildren. RESEARCH DESIGN AND METHODS:Of 5,103 children (2,526 males) 4-13 years old who underwent anthropometric measurements, 530 had more extensive testing. Body mass index (BMI), wa...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究
doi:10.1089/dia.2006.0017
更新日期:2007-04-01 00:00:00
abstract::Maintaining optimal blood glucose (BG) control is difficult for type 1 diabetes mellitus (T1DM) patients when typical daily regimens of food, insulin and exercise are altered. Artificial intelligence (AI) systems consisting of treatment algorithms calibrated through large datasets of patient specific information may o...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/15209150050501989
更新日期:2000-01-01 00:00:00
abstract:BACKGROUND:Continuous glucose monitoring (CGM) provides glucose trend information that can be used to guide treatment and motivate patients with diabetes. Currently, the evidence on effectiveness of CGM in patients with type 2 diabetes is debatable. We aim to provide a systematic review and meta-analysis to synthesize ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,meta分析
doi:10.1089/dia.2018.0177
更新日期:2018-09-01 00:00:00
abstract:BACKGROUND:Prediction of glycemic profile is an important task for both early recognition of hypoglycemia and enhancement of the control algorithms for optimization of insulin infusion rate. Adaptive models for glucose prediction and recognition of hypoglycemia based on statistical and artificial intelligence technique...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2011.0093
更新日期:2012-02-01 00:00:00
abstract::The World Wide Web has become remarkably quickly an alternative source of information for patients and their relatives, as well as students and health-care professionals. A whole plethora of websites and Internet-based applications related to diabetes have appeared in recent years. In this column, selected issues surr...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2005.7.225
更新日期:2005-02-01 00:00:00
abstract:BACKGROUND:Automated insulin management features of the MiniMed® 640G sensor-augmented pump system include suspension in response to predicted low sensor glucose (SG) values ("suspend before low"), suspension in response to existing low SG values ("suspend on low"), and automatic restarting of basal insulin delivery up...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2016.0216
更新日期:2016-10-01 00:00:00
abstract::Most previous attempts at the development of a "smart tattoo" for glucose monitoring in diabetes--implantable fluorescent microspheres that can be implanted intradermally and interrogated transdermally using light--have focused on the encapsulation of a competitive binding assay for glucose within hydrogel microsphere...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2006.8.288
更新日期:2006-06-01 00:00:00
abstract::Current clinical guidelines for diabetes care encourage self-monitoring of blood glucose (SMBG) to improve glycemic control. Specific protocols remain variable, however, particularly among non-insulin-using patients. This is due in part to efficacy studies that neglect to consider (1) the performance of monitoring equ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2008.0104
更新日期:2008-12-01 00:00:00
abstract:OBJECTIVE:Hemoglobin A1c (A1C) has recently been recommended for diagnosing diabetes mellitus and diabetes risk (prediabetes). Its performance compared with fasting plasma glucose (FPG) and 2-h post-glucose load (2HPG) is not well delineated. We compared the performance of A1C with that of FPG and 2HPG in preoperative ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2011.0074
更新日期:2011-12-01 00:00:00
abstract::Self-monitoring of blood glucose was described as one of the most important advancements in diabetes management since the invention of insulin in 1920. Recent advances in glucose sensor technology for measuring interstitial glucose concentrations have challenged the dominance of glucose meters in diabetes management, ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2009.0002
更新日期:2009-06-01 00:00:00
abstract:BACKGROUND:Drugs with unspecific stimulating effects on beta-cell secretion increase the homeostasis model assessment (HOMA)-B score, indicating improved beta-cell "function." We investigated whether the beta-cell protection provided by adding pioglitazone (PIO) to glimepiride (GLIM) in comparison to up-titrating the G...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2010.0019
更新日期:2010-08-01 00:00:00
abstract:BACKGROUND:This study explored the relationships between exogenous insulin requirements and endogenous variables in elderly patients with type 2 diabetes (T2D). SUBJECTS AND METHODS:Patients with T2D 65 years of age or older were enrolled for a short hospitalization period in order to start or change their basal-bolus...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2015.0044
更新日期:2016-05-01 00:00:00
abstract:INTRODUCTION:The ProAct study has shown that a pump switch to the Accu-Chek(®) Combo system (Roche Diagnostics Deutschland GmbH, Mannheim, Germany) in type 1 diabetes patients results in stable glycemic control with significant improvements in glycated hemoglobin (HbA1c) in patients with unsatisfactory baseline HbA1c a...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章,多中心研究
doi:10.1089/dia.2014.0278
更新日期:2015-06-01 00:00:00
abstract:BACKGROUND:Implanted insulin pumps using the peritoneal route provide long-term improvement of glucose control compared with subcutaneous insulin therapy in type 1 diabetes (T1D) patients. The stability of insulin preparation is critical for a safe use in implanted pumps. Insuman implantable(®) (400 IU/mL) (Sanofi-Aven...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1089/dia.2013.0369
更新日期:2014-09-01 00:00:00
abstract:BACKGROUND:Currently, two systems for continuous tissue glucose monitoring (CGM) (Dexcom® G5 [DG5] and FreeStyle Libre [FL]) are intended to replace blood glucose monitoring (BGM) and, according to manufacturer labeling, are distributed as such in some jurisdictions, including the United States and the European Union. ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2018.0105
更新日期:2018-08-01 00:00:00
abstract::Type 2 diabetes is thought to develop as a result of progressive beta-cell dysfunction in the setting of insulin resistance, leading to increased risks of microvascular and macrovascular complications. Type 2 diabetes is currently treated with diet and exercise, followed by oral drug therapy, and finally exogenous ins...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2006.8.385
更新日期:2006-06-01 00:00:00
abstract:BACKGROUND:This article reports a prolonged trial with insulin pumps implanted in patients with type 1 diabetes showing poor glucose control and a high rate of complications. METHODS:We reviewed data from 181 patients undergoing implanted insulin pump therapy. Analysis included hemoglobin A1c (HbA1c) values, body weig...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2010.0209
更新日期:2011-06-01 00:00:00
abstract::Use of the Medtronic MiniMed Continuous Glucose Monitoring System (CGMS) in non-diabetic children has revealed many low and high sensor glucose (SG) values, suggesting that the original analytical algorithm (Solutions 2.0) might be overreading glycemic excursions. A revised algorithm (Solutions 3.0) was introduced in ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/152091503765691866
更新日期:2003-01-01 00:00:00