Incretin mimetics and dipeptidyl peptidase-IV inhibitors: a review of emerging therapies for type 2 diabetes.

Abstract:

:Type 2 diabetes is thought to develop as a result of progressive beta-cell dysfunction in the setting of insulin resistance, leading to increased risks of microvascular and macrovascular complications. Type 2 diabetes is currently treated with diet and exercise, followed by oral drug therapy, and finally exogenous insulin. While this approach is known to improve glycemic control, none of the currently available therapies significantly improve beta-cell function. In addition, this approach does not address defects in hormonal secretion thought to play key roles in the pathophysiology of type 2 diabetes. Type 2 diabetes is characterized by excess glucagon secretion and insufficient secretion of the hormone amylin from the pancreatic beta-cell. In addition, individuals with type 2 diabetes demonstrate insufficient secretion of the incretin hormone glucagon-like peptide-1 (GLP-1). Novel therapies that leverage the so-called "incretin effect" of GLP-1 (including the incretin mimetics and dipeptidyl peptidase-IV (DPP-IV) inhibitors) are being actively developed for the management of type 2 diabetes. Incretin mimetics are either derivatives of GLP-1, modified to resist proteolysis, or are novel peptides that share glucoregulatory functions with GLP-1 and are naturally resistant to proteolysis. DPP-IV inhibitors enhance the concentration of endogenous GLP-1 by limiting proteolysis of native GLP-1. With the approval of exenatide- the first "incretin mimetic"-treatment of type 2 diabetes will no doubt be changed. An understanding of the effects of these compounds will be needed to enhance the clinical approach to diabetes treatment.

journal_name

Diabetes Technol Ther

authors

Kendall DM,Kim D,Maggs D

doi

10.1089/dia.2006.8.385

subject

Has Abstract

pub_date

2006-06-01 00:00:00

pages

385-96

issue

3

eissn

1520-9156

issn

1557-8593

journal_volume

8

pub_type

杂志文章,评审
  • NerveCheck for the Detection of Sensory Loss and Neuropathic Pain in Diabetes.

    abstract:BACKGROUND:Accurate and economic detection of nerve damage in diabetes is key to more widespread diagnosis of patients with diabetic peripheral neuropathy (DPN) and painful diabetic neuropathy. This study examined the diagnostic performance of NerveCheck, an inexpensive ($500) quantitative sensory testing (QST) device....

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2016.0279

    authors: Ponirakis G,Odriozola MN,Odriozola S,Petropoulos IN,Azmi S,Ferdousi M,Fadavi H,Alam U,Marshall A,Jeziorska M,Miro A,Kheyami A,Tavakoli M,Al-Ahmar A,Odriozola MB,Odriozola A,Malik RA

    更新日期:2016-12-01 00:00:00

  • Effectiveness of Automated Insulin Management Features of the MiniMed® 640G Sensor-Augmented Insulin Pump.

    abstract:BACKGROUND:Automated insulin management features of the MiniMed® 640G sensor-augmented pump system include suspension in response to predicted low sensor glucose (SG) values ("suspend before low"), suspension in response to existing low SG values ("suspend on low"), and automatic restarting of basal insulin delivery up...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2016.0216

    authors: Zhong A,Choudhary P,McMahon C,Agrawal P,Welsh JB,Cordero TL,Kaufman FR

    更新日期:2016-10-01 00:00:00

  • Self-monitoring of blood glucose in diabetes: from evidence to clinical reality in Central and Eastern Europe--recommendations from the international Central-Eastern European expert group.

    abstract::Self-monitoring of blood glucose (SMBG) is universally considered to be an integral part of type 1 diabetes management and crucial for optimizing the safety and efficacy of complex insulin regimens. This extends to type 2 diabetes patients on intensive insulin therapy, and there is also a growing body of evidence sugg...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2013.0302

    authors: Czupryniak L,Barkai L,Bolgarska S,Bronisz A,Broz J,Cypryk K,Honka M,Janez A,Krnic M,Lalic N,Martinka E,Rahelic D,Roman G,Tankova T,Várkonyi T,Wolnik B,Zherdova N

    更新日期:2014-07-01 00:00:00

  • Virtual Coaching to Enhance Diabetes Care.

    abstract::Rates of diabetes are increasing worldwide and there is not a sufficient clinical workforce to care for these patients. Diabetes-related apps are a feasible way to provide diabetes education to large numbers of people with diabetes but attrition rates are high. Apps enhanced by virtual coaching may be a way to circumn...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2019.0016

    authors: Ramchandani N

    更新日期:2019-06-01 00:00:00

  • Biochemical stabilization of glucagon at alkaline pH.

    abstract:BACKGROUND:For patients with type 1 diabetes mellitus, a bihormonal artificial endocrine pancreas system utilizing glucagon and insulin has been found to stabilize glycemic control. However, commercially available formulations of glucagon cannot currently be used in such systems because of physical instability characte...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2014.0047

    authors: Caputo N,Jackson MA,Castle JR,El Youssef J,Bakhtiani PA,Bergstrom CP,Carroll JM,Breen ME,Leonard GL,David LL,Roberts CT Jr,Ward WK

    更新日期:2014-11-01 00:00:00

  • Outpatient assessment of determinants of glucose excursions in adolescents with type 1 diabetes: proof of concept.

    abstract:UNLABELLED:Abstract Objective: Controlled inpatient studies on the effects of food, physical activity (PA), and insulin dosing on glucose excursions exist, but such outpatient data are limited. We report here outpatient data on glucose excursions and its key determinants over 5 days in 30 adolescents with type 1 diab...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2012.0053

    authors: Maahs DM,Mayer-Davis E,Bishop FK,Wang L,Mangan M,McMurray RG

    更新日期:2012-08-01 00:00:00

  • Development and Validation of the Continuous Subcutaneous Insulin Infusion-Related Quality-of-Life (CSII-QOL) Scale.

    abstract:: Background: Continuous subcutaneous insulin infusion (CSII) is associated with improved glycemic control, a reduced incidence of hypoglycemia, and improved quality of life (QOL). To date, however, there has been no QOL scale specific to CSII. The objective of this study wa...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2019.0216

    authors: Sakane N,Murata T,Tone A,Kato K,Kimura M,Kawashima S,Sawaki H,Hirota Y,Okada A,Kuroda A,Matsuhisa M,Watanabe T,Suganuma A,Nirengi S,Toyoda M

    更新日期:2020-03-01 00:00:00

  • A tale of two compartments: interstitial versus blood glucose monitoring.

    abstract::Self-monitoring of blood glucose was described as one of the most important advancements in diabetes management since the invention of insulin in 1920. Recent advances in glucose sensor technology for measuring interstitial glucose concentrations have challenged the dominance of glucose meters in diabetes management, ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2009.0002

    authors: Cengiz E,Tamborlane WV

    更新日期:2009-06-01 00:00:00

  • Feasibility Study of a Hybrid Closed-Loop System with Automated Insulin Correction Boluses.

    abstract:: Background: The Medtronic MiniMed™ 670G system adjusts basal insulin delivery in response to continuous glucose monitoring levels and is already in use in clinical practice. We tested the home-based feasibility of the new MiniMed advanced hybrid closed-loop (AHCL) system, ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2020.0448

    authors: Nimri R,Grosman B,Roy A,Nir J,Fisch Shvalb N,Kurtz N,Loewenthal N,Gillon-Keren M,Muller I,Atlas E,Phillip M

    更新日期:2020-12-08 00:00:00

  • Management of patients with diabetes through information technology: tools for monitoring and control of the patients' metabolic behavior.

    abstract:BACKGROUND:The junction of telemedicine home monitoring with multifaceted disease management programs seems nowadays a promising direction to combine the need for an intensive approach to deal with diabetes and the pressure to contain the costs of the interventions. Several projects in the European Union and the United...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2004.6.567

    authors: Bellazzi R,Arcelloni M,Ferrari P,Decata P,Hernando ME,García A,Gazzaruso C,Gómez EJ,Larizza C,Fratino P,Stefanelli M

    更新日期:2004-10-01 00:00:00

  • Recovery of β-cell functions with low-dose insulin therapy: study in newly diagnosed type 2 diabetes mellitus patients.

    abstract:AIM:Insulin therapy induces remission in subjects with newly diagnosed type 2 diabetes mellitus (T2DM). This study assessed the insulin and C-peptide levels in newly diagnosed T2DM subjects during low-dose insulin therapy. SUBJECTS AND METHODS:Twenty newly diagnosed, drug-naive, T2DM patients without acute or chronic ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2010.0187

    authors: Bhattacharya S,Ammini AC,Jyotsna V,Gupta N,Dwivedi S

    更新日期:2011-04-01 00:00:00

  • Daily glucose profiles in Japanese people with normal glucose tolerance as assessed by continuous glucose monitoring.

    abstract:BACKGROUND:Little information is available regarding glucose fluctuations in postprandial states and during the oral glucose tolerance test (OGTT) in Japanese people with normal glucose tolerance (NGT). METHODS:Glucose profiles of 27 Japanese people were measured for 4 days by using continuous glucose monitoring. A 75...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2008.0083

    authors: Tsujino D,Nishimura R,Taki K,Miyashita Y,Morimoto A,Tajima N

    更新日期:2009-07-01 00:00:00

  • Alternative delivery of insulin via eye drops.

    abstract:BACKGROUND:Various insulin delivery systems have been considered for systemic absorption other than injections. Although the ocular route has been suggested, its use is limited by the amount of insulin absorbed systemically via eyes. In order to improve the absorption rate of insulin into systemic circulations, the eff...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2005.7.695

    authors: Xuan B,McClellan DA,Moore R,Chiou GC

    更新日期:2005-10-01 00:00:00

  • Role of Continuous Glucose Monitoring in Clinical Trials: Recommendations on Reporting.

    abstract::Thanks to significant improvements in the precision, accuracy, and usability of continuous glucose monitoring (CGM), its relevance in both ambulatory diabetes care and clinical research is increasing. In this study, we address the latter perspective and derive provisional reporting recommendations. CGM systems have be...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2017.0054

    authors: Schnell O,Barnard K,Bergenstal R,Bosi E,Garg S,Guerci B,Haak T,Hirsch IB,Ji L,Joshi SR,Kamp M,Laffel L,Mathieu C,Polonsky WH,Snoek F,Home P

    更新日期:2017-07-01 00:00:00

  • Design and Clinical Evaluation of the Interoperable Artificial Pancreas System (iAPS) Smartphone App: Interoperable Components with Modular Design for Progressive Artificial Pancreas Research and Development.

    abstract:BACKGROUND:There is an unmet need for a modular artificial pancreas (AP) system for clinical trials within the existing regulatory framework to further AP research projects from both academia and industry. We designed, developed, and tested the interoperable artificial pancreas system (iAPS) smartphone app that can int...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0278

    authors: Deshpande S,Pinsker JE,Zavitsanou S,Shi D,Tompot R,Church MM,Andre C,Doyle FJ 3rd,Dassau E

    更新日期:2019-01-01 00:00:00

  • Estimated Lifetime Economic Burden of Type 1 Diabetes.

    abstract:: Background: The financial strain of type 1 diabetes on the United States health care system, patients, and employers underscores the importance of developing novel treatments for the disease. This study estimated the lifetime economic burden attributable to type 1 diabetes...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2019.0398

    authors: Sussman M,Benner J,Haller MJ,Rewers M,Griffiths R

    更新日期:2020-02-01 00:00:00

  • Evaluation of the Adherence to Continuous Glucose Monitoring in the Management of Type 1 Diabetes Patients on Sensor-Augmented Pump Therapy: The SENLOCOR Study.

    abstract:BACKGROUND:Continuous glucose monitoring (CGM) and sensor-augmented pump (SAP) therapy improve glucose control provided good adherence. In France, not only diabetologists, nurses, and dieticians but also nurses employed by homecare providers (HCPNs) are together involved in the initiation and/or follow-up of continuous...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究

    doi:10.1089/dia.2015.0240

    authors: Picard S,Hanaire H,Baillot-Rudoni S,Gilbert-Bonnemaison E,Not D,Reznik Y,Guerci B

    更新日期:2016-03-01 00:00:00

  • Factors Affecting Recruitment of Participants for Studies of Diabetes Technology in Newly Diagnosed Youth with Type 1 Diabetes: A Qualitative Focus Group Study with Parents and Children.

    abstract:BACKGROUND:Relatively little is known about parents' or children's attitudes toward recruitment for, and participation in, studies of new diabetes technologies immediately after diagnosis. This study investigated factors affecting recruitment of participants for studies in newly diagnosed youth with type 1 diabetes. M...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2016.0157

    authors: Farrington C,Allen J,Tauschmann M,Randell T,Trevelyan N,Hovorka R

    更新日期:2016-09-01 00:00:00

  • The emergence of biosimilar insulin preparations--a cause for concern?

    abstract::Several biopharmaceuticals, including insulin and insulin analogs, are, or shortly will be, off-patent, thereby providing an opportunity for companies to attempt to manufacture "copies" commonly referred to as biosimilars and also known as follow-on biologics. Reassurance that such copy biologics are equally safe and ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2012.0105

    authors: Owens DR,Landgraf W,Schmidt A,Bretzel RG,Kuhlmann MK

    更新日期:2012-11-01 00:00:00

  • Measurement Performance of Two Continuous Tissue Glucose Monitoring Systems Intended for Replacement of Blood Glucose Monitoring.

    abstract:BACKGROUND:Currently, two systems for continuous tissue glucose monitoring (CGM) (Dexcom® G5 [DG5] and FreeStyle Libre [FL]) are intended to replace blood glucose monitoring (BGM) and, according to manufacturer labeling, are distributed as such in some jurisdictions, including the United States and the European Union. ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0105

    authors: Freckmann G,Link M,Pleus S,Westhoff A,Kamecke U,Haug C

    更新日期:2018-08-01 00:00:00

  • Accuracy of FreeStyle Libre in Adults with Type 1 Diabetes: The Effect of Sensor Age.

    abstract:: Background: FreeStyle Libre is a factory-calibrated continuous 14-day glucose sensor. Little is known about the accuracy of FreeStyle Libre as a function of sensor age. Methods: We assessed the accuracy of FreeStyle Libre in 14...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章

    doi:10.1089/dia.2019.0262

    authors: Tsoukas M,Rutkowski J,El-Fathi A,Yale JF,Bernier-Twardy S,Bossy A,Pytka E,Legault L,Haidar A

    更新日期:2020-03-01 00:00:00

  • Evaluation of a new blood glucose monitoring system with auto-calibration.

    abstract:BACKGROUND:The Ascensia CONTOUR System (Bayer HealthCare LLC, Elkhart, IN) is a new blood glucose (BG) monitoring system (BGMS) that uses glucose dehydrogenase chemistry and that combines low sample volume, fast response time, an auto-control marking feature, and an auto-calibration function in a small package. METHOD...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究

    doi:10.1089/dia.2005.7.283

    authors: Kilo C,Pinson M,Joynes JO,Joseph H,Monhaut N,Parkes JL,Baum J

    更新日期:2005-04-01 00:00:00

  • Validation of physical activity monitors in individuals with diabetes: energy expenditure estimation by the multisensor SenseWear Armband Pro3 and the step counter Omron HJ-720 against indirect calorimetry during walking.

    abstract:BACKGROUND:The purpose of this study is to test the agreement between energy expenditure estimate of the SenseWear(®) Armband Pro3 (SWA) (BodyMedia, Pittsburgh, PA) and the Omron HJ-720 (Omron Healthcare, Kyoto, Japan) step counter with indirect calorimetry (IC) as a gold standard in older individuals with type 1 and t...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2012.0235

    authors: Machač S,Procházka M,Radvanský J,Slabý K

    更新日期:2013-05-01 00:00:00

  • Characterization of Daily Glycemic Variability in Subjects with Type 1 Diabetes Using a Mixture of Metrics.

    abstract:: Background: Glycemic variability (GV) is an important component of glycemic control for patients with type 1 diabetes (T1D). The inadequacy of existing measurements lies in the fact that they view the variability from different aspects, so that no consensus has been reache...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2019.0250

    authors: Zheng F,Jalbert M,Forbes F,Bonnet S,Wojtusciszyn A,Lablanche S,Benhamou PY

    更新日期:2020-04-01 00:00:00

  • Preserving Skin Integrity with Chronic Device Use in Diabetes.

    abstract::Skin integrity and diabetes device placement are ongoing concerns for people with diabetes who utilize continuous glucose monitors (CGMs) and continuous subcutaneous insulin infusion pumps. This is especially significant for individuals with skin sensitivities, pediatric patients, and those who use devices chronically...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0080

    authors: Messer LH,Berget C,Beatson C,Polsky S,Forlenza GP

    更新日期:2018-06-01 00:00:00

  • Development of optimal kids insulin dosing system formulas for young children with type 1 diabetes mellitus.

    abstract:OBJECTIVE:This study was designed to develop predictive formulas for precise insulin dosing in young children with type 1 diabetes (T1DM). RESEARCH DESIGN AND METHODS:Consecutive 1-year data from a group of 14 young patients (eight girls, six boys) 3.9 ± 0.8 years old with diabetes duration of 2.0 ± 0.8 years, transit...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2011.0184

    authors: Alemzadeh R,Hoffmann RG,Dasgupta M,Parton E

    更新日期:2012-05-01 00:00:00

  • Efficacy and Safety of Biosimilar SAR342434 Insulin Lispro in Adults with Type 1 Diabetes Also Using Insulin Glargine-SORELLA 1 Study.

    abstract:BACKGROUND:SAR342434 is a biosimilar follow-on of insulin lispro-Humalog®. This study aimed to show similar efficacy, safety, and immunogenicity of SAR342434 (SAR-Lis) versus insulin lispro-Humalog (Ly-Lis) in adult patients with type 1 diabetes (T1DM) treated with multiple daily injections while using basal insulin gl...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1089/dia.2017.0117

    authors: Garg SK,Wernicke-Panten K,Rojeski M,Pierre S,Kirchhein Y,Jedynasty K

    更新日期:2017-09-01 00:00:00

  • Noninvasive continuous glucose monitoring using photoacoustic technology-results from the first 62 subjects.

    abstract:BACKGROUND:Continuous glucose monitoring is a useful tool for the achievement of improved glucose control in patients with diabetes. We tested the ability of a novel noninvasive continuous glucose monitor to track glucose excursions. METHODS:The novel noninvasive Aprise sensor (Glucon Inc., Boulder, CO) utilizes the p...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章

    doi:10.1089/dia.2006.0059

    authors: Weiss R,Yegorchikov Y,Shusterman A,Raz I

    更新日期:2007-02-01 00:00:00

  • Lasers and diabetic retinopathy: the art of gentle destruction.

    abstract::Laser retinal photocoagulation represents the primary therapy for the potentially blinding manifestations of diabetic retinopathy. Advances in laser therapy for diabetic eye disease have arisen from the convergence of laser technology and clinical ophthalmology. In this review, the basis of laser therapy in diabetic r...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/152091599317396

    authors: Petrovic V,Bhisitkul RB

    更新日期:1999-07-01 00:00:00

  • Using multiple measures of glycemia to support individualized diabetes management: recommendations for clinicians, patients, and payers.

    abstract::By the year 2030, the diabetes pandemic will likely affect more than 10% of the world's population. The personal, public health, and economic crises implicit in this trend call for decisive action. Yet, escalating dilemmas thwart full realization of current therapies. First, controversial studies, such as the Action t...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2012.0132

    authors: Hirsch IB,Amiel SA,Blumer IR,Bode BW,Edelman SV,Seley JJ,Verderese CA,Kilpatrick ES

    更新日期:2012-11-01 00:00:00