Administration of Biosimilar Insulin Analogs: Role of Devices.

Abstract:

:With the expiration of patent protection for several originator insulin analog molecules, the availability of insulin analog copies is set to increase. Many regulatory authorities have developed, and continue to refine, guidelines for the approval of biosimilar insulin analogs. Aspects such as the structure, pharmacokinetics and pharmacodynamics, efficacy, safety, and immunogenicity of biosimilar insulin analogs are extensively addressed in these guidelines, but how the biosimilar insulin analog is administered to people with diabetes is not usually a topic. The aim of this article is to highlight that the delivery device-drug combination is of particular importance. Regulatory, legal, and practical aspects of the delivery device, be it a syringe, pen, or pump, have to be considered in the context of biosimilar insulin analogs. Although the safety and efficacy of biosimilar insulin analogs per se are of primary importance for physicians and people with diabetes, functions and features of the devices used for administration also require attention from a practical point of view. Unfortunately, although there are several clinical studies investigating the technical aspects of and patient preference for the originator insulin analog pens, there are currently very little published data for nonoriginator or biosimilar insulin analog pens. In addition, it is not known if it is safe to assume that a biosimilar insulin analog cartridge is compatible with an existing originator insulin analog pen. We believe that there is a need for more discussion on the role of devices for administration of biosimilar insulin analogs.

journal_name

Diabetes Technol Ther

authors

Heinemann L,Fritz I,Khatami H,Edelman SV

doi

10.1089/dia.2016.0263

subject

Has Abstract

pub_date

2017-02-01 00:00:00

pages

79-84

issue

2

eissn

1520-9156

issn

1557-8593

journal_volume

19

pub_type

杂志文章,评审
  • Analysis of continuous glucose monitoring data from non-diabetic and diabetic children: a tale of two algorithms.

    abstract::Use of the Medtronic MiniMed Continuous Glucose Monitoring System (CGMS) in non-diabetic children has revealed many low and high sensor glucose (SG) values, suggesting that the original analytical algorithm (Solutions 2.0) might be overreading glycemic excursions. A revised algorithm (Solutions 3.0) was introduced in ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/152091503765691866

    authors: Weinzimer SA,DeLucia MC,Boland EA,Steffen A,Tamborlane WV

    更新日期:2003-01-01 00:00:00

  • Basal plus basal-bolus approach in type 2 diabetes.

    abstract::Type 2 diabetes is characterized by insulin resistance and progressive β-cell deterioration. As β-cell function declines, most patients with type 2 diabetes treated with oral agents, in monotherapy or combination, will require insulin therapy. Addition of basal insulin (glargine, detemir, or NPH/neutral protamine lisp...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2011.0001

    authors: Ampudia-Blasco FJ,Rossetti P,Ascaso JF

    更新日期:2011-06-01 00:00:00

  • The design and performance of the exubera pulmonary insulin delivery system.

    abstract::The Exubera system (Pfizer, New York, NY/Nektar Therapeutics, San Carlos, CA) is an integration of five major new technologies: protein formulation, powder processing, powder filling, drug packaging, and delivery device. The product provides a simple interface, where the patient interacts only with the delivery device...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2007.0222

    authors: Harper NJ,Gray S,De Groot J,Parker JM,Sadrzadeh N,Schuler C,Schumacher JD,Seshadri S,Smith AE,Steeno GS,Stevenson CL,Taniere R,Wang M,Bennett DB

    更新日期:2007-06-01 00:00:00

  • A Prospective Multicenter Evaluation of the Accuracy of a Novel Implanted Continuous Glucose Sensor: PRECISE II.

    abstract:BACKGROUND:Persistent use of real-time continuous glucose monitoring (CGM) improves diabetes control in individuals with type 1 diabetes (T1D) and type 2 diabetes (T2D). METHODS:PRECISE II was a nonrandomized, blinded, prospective, single-arm, multicenter study that evaluated the accuracy and safety of the implantable...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究

    doi:10.1089/dia.2017.0142

    authors: Christiansen MP,Klaff LJ,Brazg R,Chang AR,Levy CJ,Lam D,Denham DS,Atiee G,Bode BW,Walters SJ,Kelley L,Bailey TS

    更新日期:2018-03-01 00:00:00

  • Comparison of Second-Generation Basal Insulin Analogs: A Review of the Evidence from Continuous Glucose Monitoring.

    abstract::Many people with insulin-treated diabetes continue to experience inadequate glycemic control and a high incidence of hypoglycemic events, despite improvements in therapeutic strategies. While glycated hemoglobin (HbA1c) is currently recognized as the gold-standard for assessing glycemic control, the measure reflects m...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2020.0180

    authors: Battelino T,Edelman SV,Nishimura R,Bergenstal RM

    更新日期:2021-01-01 00:00:00

  • Determining clinical and psychological benefits and barriers with continuous glucose monitoring therapy.

    abstract:BACKGROUND:Preventing the complications of diabetes requires tight control and minimizing blood glucose fluctuation. Pursuing these goals increases the risk of severe hypoglycemia. The authors hoped to identify if using continuous glucose monitoring (CGM) decreased the incidence of severe hypoglycemia, resulted in less...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2009.0121

    authors: Halford J,Harris C

    更新日期:2010-03-01 00:00:00

  • Design and Clinical Evaluation of the Interoperable Artificial Pancreas System (iAPS) Smartphone App: Interoperable Components with Modular Design for Progressive Artificial Pancreas Research and Development.

    abstract:BACKGROUND:There is an unmet need for a modular artificial pancreas (AP) system for clinical trials within the existing regulatory framework to further AP research projects from both academia and industry. We designed, developed, and tested the interoperable artificial pancreas system (iAPS) smartphone app that can int...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0278

    authors: Deshpande S,Pinsker JE,Zavitsanou S,Shi D,Tompot R,Church MM,Andre C,Doyle FJ 3rd,Dassau E

    更新日期:2019-01-01 00:00:00

  • A tale of two compartments: interstitial versus blood glucose monitoring.

    abstract::Self-monitoring of blood glucose was described as one of the most important advancements in diabetes management since the invention of insulin in 1920. Recent advances in glucose sensor technology for measuring interstitial glucose concentrations have challenged the dominance of glucose meters in diabetes management, ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2009.0002

    authors: Cengiz E,Tamborlane WV

    更新日期:2009-06-01 00:00:00

  • Metrics to Evaluate Quality of Glycemic Control: Comparison of Time in Target, Hypoglycemic, and Hyperglycemic Ranges with "Risk Indices".

    abstract:OBJECTIVE:We sought to cross validate several metrics for quality of glycemic control, hypoglycemia, and hyperglycemia. RESEARCH DESIGN AND METHODS:We analyzed the mathematical properties of several metrics for overall glycemic control, and for hypo- and hyperglycemia, to evaluate their similarities, differences, and ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2017.0416

    authors: Rodbard D

    更新日期:2018-05-01 00:00:00

  • A comparison between simplified and intensive dose-titration algorithms using AIR inhaled insulin for insulin-naive patients with type 2 diabetes in a randomized noninferiority trial.

    abstract:BACKGROUND:Insulin initiation and optimization is a challenge for patients with type 2 diabetes. Our objective was to determine whether safety and efficacy of AIR inhaled insulin (Eli Lilly and Co., Indianapolis, IN) (AIR is a registered trademark of Alkermes, Inc., Cambridge, MA) using a simplified regimen was noninfe...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2009.0036

    authors: Mathieu C,Cuddihy R,Arakaki RF,Belin RM,Planquois JM,Lyons JN,Heilmann CR

    更新日期:2009-09-01 00:00:00

  • Variability of insulin absorption and insulin action.

    abstract::Subcutaneous (s.c.) injections of identical insulin doses may lead to considerable intra- and inter-individual differences in the current metabolic control of patients with diabetes mellitus. This well-known variability of the metabolic effect of insulin hampers practical insulin therapy considerably. The aim of this ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/152091502320798312

    authors: Heinemann L

    更新日期:2002-01-01 00:00:00

  • Intervention trials for prevention of metabolic syndrome and type 2 diabetes: focus on Asian Indians.

    abstract::Prevalence of diabetes continues to increase in urban areas, and escalation is discernible in semi-urban and rural areas. It is reported to affect Asian Indians a decade earlier compared with other populations, and complications (e.g., nephropathy) occur earlier and are severe and more prevalent than in other races. B...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2013.0373

    authors: Shrivastava U,Misra A

    更新日期:2014-08-01 00:00:00

  • Skin autofluorescence and complications of diabetes: does ethnic background or skin color matter?

    abstract:AIMS:Skin autofluorescence (AF) has been associated with complications of diabetes. We evaluated the influence of skin color and ethnicity on the association between skin AF and the presence of diabetes-related complications. MATERIALS AND METHODS:In a multiethnic type 2 diabetes cohort we investigated all patients wi...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2013.0374

    authors: Ahdi M,Gerdes VE,Graaff R,Kuipers S,Smit AJ,Meesters EW

    更新日期:2015-02-01 00:00:00

  • Person-centered Web support to women with type 1 diabetes in pregnancy and early motherhood--the development process.

    abstract:BACKGROUND:Pregnancy and early motherhood are extraordinarily demanding periods for women with type 1 diabetes, who therefore need optimal support. This article describes the process of developing person-centered Web-based support for women with type 1 diabetes during the period of pregnancy through early motherhood. I...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2012.0217

    authors: Berg M,Adolfsson A,Ranerup A,Sparud-Lundin C,University of Gothenburg Centre for Person-Centred Care.

    更新日期:2013-01-01 00:00:00

  • What we can really expect from telemedicine in intensive diabetes treatment: results from 3-year study on type 1 pregnant diabetic women.

    abstract::Existing standards of the management of the diabetic patients are not efficient enough, and further improvement is needed. The major objective of this paper is to present and discuss the therapeutic effectiveness of an intensive care telematic system designed and applied for intensive treatment of pregnant type 1 diab...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章

    doi:10.1089/15209150152811207

    authors: Wojcicki JM,Ladyzynski P,Krzymien J,Jozwicka E,Blachowicz J,Janczewska E,Czajkowski K,Karnafel W

    更新日期:2001-01-01 00:00:00

  • Development of optimal kids insulin dosing system formulas for young children with type 1 diabetes mellitus.

    abstract:OBJECTIVE:This study was designed to develop predictive formulas for precise insulin dosing in young children with type 1 diabetes (T1DM). RESEARCH DESIGN AND METHODS:Consecutive 1-year data from a group of 14 young patients (eight girls, six boys) 3.9 ± 0.8 years old with diabetes duration of 2.0 ± 0.8 years, transit...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2011.0184

    authors: Alemzadeh R,Hoffmann RG,Dasgupta M,Parton E

    更新日期:2012-05-01 00:00:00

  • Overcoming skin's barrier: the search for effective and user-friendly drug delivery.

    abstract::Although hypodermic needles rapidly deliver large doses of drugs such as insulin across the skin for systemic administration, the pain, local trauma, and difficulty to achieve sustained or complex delivery profiles has motivated development of novel alternative technologies. Microneedles, jet injectors, and thermal po...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/152091501300209606

    authors: Prausnitz MR

    更新日期:2001-07-01 00:00:00

  • Differences in exhaled gas profiles between patients with type 2 diabetes and healthy controls.

    abstract:AIMS:Recent advances in analytical technology allow the detection of several hundred volatile organic compounds (VOCs) in human exhaled air, many of which reflect unidentified endogenous pathways. This study was performed to determine whether a breath gas analysis using proton transfer reaction-mass spectrometry (PTR-M...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2009.0181

    authors: Greiter MB,Keck L,Siegmund T,Hoeschen C,Oeh U,Paretzke HG

    更新日期:2010-06-01 00:00:00

  • RETRACTED: No deleterious effect of lockdown due to COVID-19 pandemic on glycaemic control, measured by glucose monitoring, in adults with type 1 diabetes.

    abstract::The Editor of Diabetes Technology & Therapeutics is officially retracting the article entitled, "No Deleterious Effect of Lockdown Due to COVID-19 Pandemic on Glycaemic Control, Measured by Glucose Monitoring, in Adults with Type 1 Diabetes," by Beato-Vibora PI. Diabetes Technol Ther 2020; epub DOI: 10.1089/dia.2020.0...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,收录出版

    doi:10.1089/dia.2020.0184

    authors: Beato-Víbora PI

    更新日期:2020-05-12 00:00:00

  • Evaluation of Blood Glucose Meter Efficacy in an Antenatal Diabetes Clinic.

    abstract:BACKGROUND:The optimal treatment of diabetes in pregnancy requires accurate measurement of blood glucose levels, in order to minimize adverse outcomes for both mother and neonate. Self-monitoring of blood glucose is routinely used to measure glycemic control and to assess whether treatment targets are being met; howeve...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,收录出版

    doi:10.1089/dia.2015.0104

    authors: McGrath RT,Donnelly VC,Glastras SJ,Preda VA,Sheriff N,Ward P,Hocking SL,Fulcher GR

    更新日期:2016-02-01 00:00:00

  • Continuous glucose monitoring reveals delayed nocturnal hypoglycemia after intermittent high-intensity exercise in nontrained patients with type 1 diabetes.

    abstract:OBJECTIVE:Exercise is a cornerstone of diabetes therapy in type 1 diabetes mellitus (DMT1) patients. The type of exercise is important in determining the propensity to hypoglycemia. We assessed, by continuous glucose monitoring (CGM), the glucose profiles during and in the following 20h after a session of two different...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1089/dia.2010.0038

    authors: Maran A,Pavan P,Bonsembiante B,Brugin E,Ermolao A,Avogaro A,Zaccaria M

    更新日期:2010-10-01 00:00:00

  • Management of patients with diabetes through information technology: tools for monitoring and control of the patients' metabolic behavior.

    abstract:BACKGROUND:The junction of telemedicine home monitoring with multifaceted disease management programs seems nowadays a promising direction to combine the need for an intensive approach to deal with diabetes and the pressure to contain the costs of the interventions. Several projects in the European Union and the United...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2004.6.567

    authors: Bellazzi R,Arcelloni M,Ferrari P,Decata P,Hernando ME,García A,Gazzaruso C,Gómez EJ,Larizza C,Fratino P,Stefanelli M

    更新日期:2004-10-01 00:00:00

  • The emergence of biosimilar insulin preparations--a cause for concern?

    abstract::Several biopharmaceuticals, including insulin and insulin analogs, are, or shortly will be, off-patent, thereby providing an opportunity for companies to attempt to manufacture "copies" commonly referred to as biosimilars and also known as follow-on biologics. Reassurance that such copy biologics are equally safe and ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2012.0105

    authors: Owens DR,Landgraf W,Schmidt A,Bretzel RG,Kuhlmann MK

    更新日期:2012-11-01 00:00:00

  • The influence of environmental temperature on the response of the skin to local pressure: the impact of aging and diabetes.

    abstract:BACKGROUND:To protect against ischemia, pressure-induced vasodilation (PIV) causes an increase in skin blood flow. Endothelial dysfunction, which is commonly found in older patients and those with diabetes, and global temperatures can affect the resting blood flow in skin, which may reduce the blood flow during and aft...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2009.0097

    authors: McLellan K,Petrofsky JS,Zimmerman G,Lohman E,Prowse M,Schwab E,Lee S

    更新日期:2009-12-01 00:00:00

  • The effect of local subcutaneous delivery of vascular endothelial growth factor on the function of a chronically implanted amperometric glucose sensor.

    abstract::The foreign body capsule that forms around implanted devices such as glucose sensors is hypovascular and has limited permeability to glucose. Such a capsule may function better if well vascularized. We hypothesized that capsular vascularization achieved by local release of vascular endothelial growth factor (VEGF) wou...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/152091504773731320

    authors: Ward WK,Wood MD,Casey HM,Quinn MJ,Federiuk IF

    更新日期:2004-04-01 00:00:00

  • Mitigating Reductions in Glucose During Exercise on Closed-Loop Insulin Delivery: The Ex-Snacks Study.

    abstract:OBJECTIVE:To assess whether snacking could be used with closed-loop (CL) insulin delivery to avoid exercise-induced reductions in plasma glucose (PG), as well as elevations in PG at the end of exercise. RESEARCH DESIGN AND METHODS:Twelve type 1 diabetes (T1D) subjects (age 13-36 years, duration 10.7 ± 8.4 years, A1c 7...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2016.0311

    authors: Patel NS,Van Name MA,Cengiz E,Carria LR,Tichy EM,Weyman K,Weinzimer SA,Tamborlane WV,Sherr JL

    更新日期:2016-12-01 00:00:00

  • Predicting the effectiveness of insulin pump therapy on glycemic control in clinical practice: a retrospective study of patients with type 1 diabetes from 10 outpatient diabetes clinics in Sweden over 5 years.

    abstract:BACKGROUND:Multicenter long-term studies of predictors for the effectiveness of continuous subcutaneous insulin infusion (CSII) in clinical practice are lacking. We hypothesized that there are substantially greater reductions in hemoglobin A1c (HbA1c) in patients with poor glycemic control and that other predictors may...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2014.0139

    authors: Clements M,Matuleviciene V,Attvall S,Ekelund M,Pivodic A,Dahlqvist S,Fahlén M,Haraldsson B,Lind M

    更新日期:2015-01-01 00:00:00

  • Feasibility of a portable bihormonal closed-loop system to control glucose excursions at home under free-living conditions for 48 hours.

    abstract:BACKGROUND:This study assessed the feasibility of a portable bihormonal closed-loop system at home. SUBJECTS AND METHODS:Sixteen pump-treated patients with type 1 diabetes received 48 h of closed-loop therapy with a telemonitored insulin- and glucagon-delivering closed-loop system and 48 h of patient-managed open-loop...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2013.0166

    authors: van Bon AC,Luijf YM,Koebrugge R,Koops R,Hoekstra JB,DeVries JH

    更新日期:2014-03-01 00:00:00

  • Venous, Arterialized-Venous, or Capillary Glucose Reference Measurements for the Accuracy Assessment of a Continuous Glucose Monitoring System.

    abstract:BACKGROUND:Different reference methods are used for the accuracy assessment of continuous glucose monitoring (CGM) systems. The effect of using venous, arterialized-venous, or capillary reference measurements on CGM accuracy is unclear. METHODS:We evaluated 21 individuals with type 1 diabetes using a capillary calibra...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2017.0189

    authors: Kropff J,van Steen SC,deGraaff P,Chan MW,van Amstel RBE,DeVries JH

    更新日期:2017-11-01 00:00:00

  • The association of self-monitoring of blood glucose use with medication adherence and glycemic control in patients with type 2 diabetes initiating non-insulin treatment.

    abstract:BACKGROUND:The value of self-monitoring of blood glucose (SMBG) for persons with type 2 diabetes who do not use insulin remains controversial. This observational study compares the likelihood of medication adherence and change in glycated hemoglobin (A1C) for non-insulin-using patients using SMBG versus those not using...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2012.0047

    authors: Virdi N,Daskiran M,Nigam S,Kozma C,Raja P

    更新日期:2012-09-01 00:00:00