Abstract:
AIMS:Skin autofluorescence (AF) has been associated with complications of diabetes. We evaluated the influence of skin color and ethnicity on the association between skin AF and the presence of diabetes-related complications. MATERIALS AND METHODS:In a multiethnic type 2 diabetes cohort we investigated all patients with available skin AF measurements. The associations between skin AF and hemoglobin A1c (HbA1c) and the presence of complications of diabetes were estimated, stratified for ethnicity and quartiles of ultraviolet reflectance percentage (R%). RESULTS:In total, 810 patients (438 native Dutch, 372 non-Dutch) were included. Because of too low an R%, 32% of black Africans and 19% of Hindustanis were excluded. Non-Dutch patients had lower AF values compared with Dutch patients (median AF=2.69 [interquartile range (IQR), 2.26-3.09] vs. 3.06 [IQR, 2.65-3.50] arbitrary units; P<0.001), but the R% was also lower (non-Dutch, median R%=12% [IQR, 9-15%]; Dutch, median R%=18% [IQR, 14-23%]; P=0.027). In the multivariate analysis, skin AF was only a determinant for complications in patients with R% 25(th) percentile (macrovascular, odds ratio [OR]=1.71 [95% confidence interval (CI), 1.05-2.77] vs. 1.15 [95% CI, 0.55-2.40] in the lowest quartile of R%; microvascular, OR=1.81 [95% CI, 1.20-2.75] vs. OR=0.87 [95% CI, 0.50-1.51]). A similar pattern was observed for nephropathy, neuropathy, and retinopathy separately. In non-Dutch patients AF was not a significant determinant for diabetes complication risk, whereas HbA1c was for nephropathy, retinopathy, and neuropathy. CONCLUSIONS:Skin AF measurement is a valuable tool for the assessment of micro- and macrovascular complication risk in patients with light skin color types. Even after exclusion of patients with too low a reflectance, the current performance of the AGE Reader™ (DiagnOptics Technologies BV, Groningen, The Netherlands) was insufficient in darker-skinned patients.
journal_name
Diabetes Technol Therjournal_title
Diabetes technology & therapeuticsauthors
Ahdi M,Gerdes VE,Graaff R,Kuipers S,Smit AJ,Meesters EWdoi
10.1089/dia.2013.0374subject
Has Abstractpub_date
2015-02-01 00:00:00pages
88-95issue
2eissn
1520-9156issn
1557-8593journal_volume
17pub_type
杂志文章abstract:BACKGROUND:To examine trimester-specific associations among glycemic variability, fetal growth, and birthweight in pregnancies with type 1 diabetes mellitus (Type 1 DM). METHODS:In this retrospective cohort study of 41 pregnant women with Type 1 DM, we used continuous glucose monitoring (CGM) data to calculate glycemi...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2017.0443
更新日期:2018-06-01 00:00:00
abstract:BACKGROUND:Pregnancy and early motherhood are extraordinarily demanding periods for women with type 1 diabetes, who therefore need optimal support. This article describes the process of developing person-centered Web-based support for women with type 1 diabetes during the period of pregnancy through early motherhood. I...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2012.0217
更新日期:2013-01-01 00:00:00
abstract:BACKGROUND:The junction of telemedicine home monitoring with multifaceted disease management programs seems nowadays a promising direction to combine the need for an intensive approach to deal with diabetes and the pressure to contain the costs of the interventions. Several projects in the European Union and the United...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2004.6.567
更新日期:2004-10-01 00:00:00
abstract:BACKGROUND:The Optimizing Control in Diabetes (OPTIMIZE) survey was conducted to understand the patients' perspective to achieving good glycemic control and to determine how patients' perceptions of insulin may affect their decisions to initiate or intensify their insulin therapy. METHODS:A total of 1,444 subjects wit...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究
doi:10.1089/dia.2008.0249
更新日期:2008-02-01 00:00:00
abstract:BACKGROUND:Vascular endothelial growth factor (VEGF) is involved in the pathogenesis of diabetic microvascular disease. Most diabetes patients have higher serum levels of ferritin that may participate in diabetic vascular complications through high oxidative stress induced by iron. However, the mechanistic link between...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2013.0181
更新日期:2014-04-01 00:00:00
abstract::Patients with diabetes play with a double-edged sword when it comes to deciding glucose and A1c target levels. On the one side, tight control has been shown to be crucial in avoiding long-term complications; on the other, tighter control leads to an increased risk of iatrogenic hypoglycemia, which is compounded when h...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2005.7.3
更新日期:2005-02-01 00:00:00
abstract::Prevalence of diabetes continues to increase in urban areas, and escalation is discernible in semi-urban and rural areas. It is reported to affect Asian Indians a decade earlier compared with other populations, and complications (e.g., nephropathy) occur earlier and are severe and more prevalent than in other races. B...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2013.0373
更新日期:2014-08-01 00:00:00
abstract::Insulin infusion pump therapy has dramatically improved over the past 20 years and can now address some of the specific challenges related to toddlers with diabetes. We discuss both the non-randomized and randomized controlled trials comparing continuous subcutaneous insulin infusion (CSII) and multiple daily injectio...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2009.0182
更新日期:2010-06-01 00:00:00
abstract::Chronic hyperglycemia, as assessed by hemoglobin A1c (HbA1c) levels, has been associated with the development of microvascular and macrovascular complications of diabetes. Several studies have shown that acute hyperglycemia can add to the effect of chronic hyperglycemia in inducing tissue damage. Acute hyperglycemia c...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2010.0146
更新日期:2011-03-01 00:00:00
abstract:BACKGROUND:The aim of this study was to elucidate the characteristics of accuracy of subcutaneous continuous glucose monitoring (SCGM) in the perioperative period for neurosurgical and cardiac surgery patients. METHODS:Forty-five subjects, including healthy volunteers (n = 15), neurosurgical patients (n = 15), and car...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2018.0140
更新日期:2018-10-01 00:00:00
abstract:BACKGROUND:Currently, it is still unknown whether differences in glycemic control have any effect on glucose and insulin kinetics after vildagliptin administration. The aim of this study was to evaluate the effect of vildagliptin on glucose and insulin concentrations during a 24-h period in type 2 diabetes patients wit...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2013.0020
更新日期:2013-07-01 00:00:00
abstract::The microdialysis technique allows extraction of substances (e.g., glucose) from fluids in the human body for quantitative measurements ex vivo. The microdialysis catheter can be inserted in many different tissues; for continuous glucose monitoring it is most often implanted in the subcutaneous fat tissue in the abdom...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/152091503322250578
更新日期:2003-01-01 00:00:00
abstract:BACKGROUND:Glutamic acid decarboxylase-65 (GAD65) is a major autoantigen in autoimmune diabetes and is discharged from injured islet beta cells. GAD65 may also be released by transplanted islets undergoing immunological rejection. To test hypotheses regarding the utility of GAD65 as a biomarker for transplant rejection...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2006.8.207
更新日期:2006-04-01 00:00:00
abstract:BACKGROUND:For patients with diabetes, the quality of outpatient glycemic control is readily assessed by hemoglobin A1c. In contrast, standardized measures for assessing the quality of blood glucose (BG) management in hospitalized patients are lacking. Because of recent studies demonstrating the benefits of strict glyc...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2006.8.560
更新日期:2006-10-01 00:00:00
abstract:OBJECTIVE:To assess whether snacking could be used with closed-loop (CL) insulin delivery to avoid exercise-induced reductions in plasma glucose (PG), as well as elevations in PG at the end of exercise. RESEARCH DESIGN AND METHODS:Twelve type 1 diabetes (T1D) subjects (age 13-36 years, duration 10.7 ± 8.4 years, A1c 7...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2016.0311
更新日期:2016-12-01 00:00:00
abstract:BACKGROUND:Obstructive sleep apnea (OSA), a highly prevalent condition, is independently associated with increased risks of developing type 2 diabetes mellitus (T2D) and metabolic syndrome. It is unclear, however, if the severity of OSA has any impact on glycemic control among patients with T2D. We therefore aimed to d...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2011.0005
更新日期:2011-09-01 00:00:00
abstract:AIM:The aim of this study was to assess the associations of six single nucleotide polymorphisms (SNPs) of three genes (DRD3, COMT, and SCL6A4) with type 2 diabetes mellitus (T2DM) in Southern Chinese. SUBJECTS AND METHODS:Five hundred ninety-five cases with T2DM and 725 healthy controls of Han origin were recruited fr...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2014.0344
更新日期:2015-08-01 00:00:00
abstract:OBJECTIVES:Hyperglycemia is a prominent feature among patients exposed to major stress such as in cardiac surgery. The implementation of a continuous glucose monitoring system (CGMS) for glucose monitoring during cardiac surgery was assessed. SUBJECTS AND METHODS:Fifty-nine consecutive patients who underwent cardiac s...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2011.0154
更新日期:2012-03-01 00:00:00
abstract:BACKGROUND:Continuous glucose monitoring (CGM) and sensor-augmented pump (SAP) therapy improve glucose control provided good adherence. In France, not only diabetologists, nurses, and dieticians but also nurses employed by homecare providers (HCPNs) are together involved in the initiation and/or follow-up of continuous...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究
doi:10.1089/dia.2015.0240
更新日期:2016-03-01 00:00:00
abstract:: Background: FreeStyle Libre is a factory-calibrated continuous 14-day glucose sensor. Little is known about the accuracy of FreeStyle Libre as a function of sensor age. Methods: We assessed the accuracy of FreeStyle Libre in 14...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章
doi:10.1089/dia.2019.0262
更新日期:2020-03-01 00:00:00
abstract::Glucagon-like peptide 1 receptor agonists (GLP-1 RAs) are highly effective at lowering hemoglobin A1c (HbA1c) and facilitating weight loss. Four agents in the GLP-1 RA class, albiglutide, liraglutide, dulaglutide, and semaglutide, also have cardioprotective effects. However, subcutaneous administration of these agents...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2019.0185
更新日期:2020-01-01 00:00:00
abstract::Existing standards of the management of the diabetic patients are not efficient enough, and further improvement is needed. The major objective of this paper is to present and discuss the therapeutic effectiveness of an intensive care telematic system designed and applied for intensive treatment of pregnant type 1 diab...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章
doi:10.1089/15209150152811207
更新日期:2001-01-01 00:00:00
abstract:BACKGROUND:This study explored the relationships between exogenous insulin requirements and endogenous variables in elderly patients with type 2 diabetes (T2D). SUBJECTS AND METHODS:Patients with T2D 65 years of age or older were enrolled for a short hospitalization period in order to start or change their basal-bolus...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2015.0044
更新日期:2016-05-01 00:00:00
abstract::Several biopharmaceuticals, including insulin and insulin analogs, are, or shortly will be, off-patent, thereby providing an opportunity for companies to attempt to manufacture "copies" commonly referred to as biosimilars and also known as follow-on biologics. Reassurance that such copy biologics are equally safe and ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2012.0105
更新日期:2012-11-01 00:00:00
abstract:BACKGROUND:Narcolepsy is a severe sleep disorder that in most patients is characterized by the deficiency of central orexin. Clinically, narcolepsy is associated with obesity. Currently, there is a literature controversy about the potential alteration of leptin levels in narcoleptic patients. Theoretically, diminished ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2006.0037
更新日期:2007-08-01 00:00:00
abstract::Diabetic nephropathy is one of the major causes of end-stage renal disease and is often associated with other macrovascular complications such as ischemic heart disease and peripheral vascular disease. Angiotensin converting enzyme inhibitors (ACE-I) and angiotensin II receptor blockers (AIIR) have both been shown to ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/152091502760098456
更新日期:2002-01-01 00:00:00
abstract:BACKGROUND:Glucose variability (GV) has been increasingly (or more extensively) studied in patients with type 1 diabetes (T1D) in the ambulatory setting; limited data exist on GV in hospitalized patients with T1D. MATERIALS AND METHODS:Retrospective single center cohort study, we analyzed in-hospital glucose measureme...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2017.0107
更新日期:2017-10-01 00:00:00
abstract::Maintaining optimal blood glucose (BG) control is difficult for type 1 diabetes mellitus (T1DM) patients when typical daily regimens of food, insulin and exercise are altered. Artificial intelligence (AI) systems consisting of treatment algorithms calibrated through large datasets of patient specific information may o...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/15209150050501989
更新日期:2000-01-01 00:00:00
abstract::There is a clear role for inflammation in the development of type 2 diabetes and its associated co-morbidities. Circulating inflammatory markers such as C-reactive protein, sialic acid, and interleukin- 6 are all significant independent predictors of disease. A number of nutritional components are hypothesized to modu...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2006.8.45
更新日期:2006-02-01 00:00:00
abstract:BACKGROUND:Continuous glucose monitoring (CGM) has been shown to improve glycemic control and reduce hypoglycemia with consistent use. Youth, however, are unlikely to use CGM consistently. We compared psychological characteristics of youth with type 1 diabetes, their parents, and adults with type 1 diabetes randomized ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2011.0201
更新日期:2012-06-01 00:00:00