Abstract:
: Background: FreeStyle Libre is a factory-calibrated continuous 14-day glucose sensor. Little is known about the accuracy of FreeStyle Libre as a function of sensor age. Methods: We assessed the accuracy of FreeStyle Libre in 14 adults with type 1 diabetes. Each study participant attended our research facility for two or three 24-h visits, during which they wore a FreeStyle Libre aged 0-1 day, 5-7 days, or 13-14 days. Plasma glucose levels were measured every 10-30 min using YSI2300 STAT Plus Analyser. Participants also wore Dexcom G5® glucose sensor aged 1-2 days. We assessed sensors' accuracy using mean absolute relative difference (MARD) between FreeStyle Libre, the Dexcom G5 sensor, and plasma glucose. Results: We had 1930 pairs of FreeStyle Libre sensor-plasma glucose measurements, collected from 36 FreeStyle Libre sensors, 18 of which were sensors aged 0-1 day, 9 were sensors aged 5-7 days, and 9 were sensors aged 13-14 days. The mean and median MARD for FreeStyle Libre sensors aged 0-1 days were 14.5% and 11.2%, respectively, and for sensors aged 13-14 days were 14.7% and 11.2%, respectively, but for sensors aged 5-7 days were 7.8% and 6.6%, respectively (P = 0.03 vs. sensors aged 0-1 days, and P = 0.06 vs. sensors aged 13-14 days). The percentage of points falling in the potentially dangerous zones C, D, or E in Clarke's error grid analysis were 1.9% for FreeStyle Libre sensors aged 0-1 day, 0.2% for sensors aged 5-7 days, and 0.4% for sensors aged 13-14 days. The overall accuracy of FreeStyle Libre and Dexcom G5 sensor was the same (mean MARD 12.8% and 12.5%, respectively; P = 0.57). Conclusions: FreeStyle Libre's accuracy is adequate during its entire lifetime but is least accurate during its first and last days. ClinicalTrials.gov Identifier: NCT02814123.
journal_name
Diabetes Technol Therjournal_title
Diabetes technology & therapeuticsauthors
Tsoukas M,Rutkowski J,El-Fathi A,Yale JF,Bernier-Twardy S,Bossy A,Pytka E,Legault L,Haidar Adoi
10.1089/dia.2019.0262subject
Has Abstractpub_date
2020-03-01 00:00:00pages
203-207issue
3eissn
1520-9156issn
1557-8593journal_volume
22pub_type
临床试验,杂志文章abstract:AIM:To describe the continuous glucose monitoring (CGM) profiles of type 1 diabetes (T1D) offspring in the early neonatal period and its association with maternal intrapartum glucose control. METHODS:A prospective observational study of T1D pregnant women and their neonatal offspring. Women had a CGM sensor inserted 2...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2018.0221
更新日期:2019-01-01 00:00:00
abstract:BACKGROUND:Children with positive islet autoantibodies monitored prospectively avoid metabolic decompensation at type 1 diabetes (T1D) diagnosis. However, the effects of early diagnosis and treatment on preservation of insulin secretion and long-term metabolic control are unknown. We compared characteristics of childre...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2015.0029
更新日期:2015-09-01 00:00:00
abstract::Several biopharmaceuticals, including insulin and insulin analogs, are, or shortly will be, off-patent, thereby providing an opportunity for companies to attempt to manufacture "copies" commonly referred to as biosimilars and also known as follow-on biologics. Reassurance that such copy biologics are equally safe and ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2012.0105
更新日期:2012-11-01 00:00:00
abstract:BACKGROUND:Insulin pumps (for continuous subcutaneous insulin infusion [CSII]) are used widely in type 1 diabetes mellitus. Although there has been considerable study of outcomes, there are few recent data on CSII-associated adverse events and no data on family perceptions of adverse events and their confidence in deal...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2013.0315
更新日期:2014-04-01 00:00:00
abstract:BACKGROUND:This study explored the relationships between exogenous insulin requirements and endogenous variables in elderly patients with type 2 diabetes (T2D). SUBJECTS AND METHODS:Patients with T2D 65 years of age or older were enrolled for a short hospitalization period in order to start or change their basal-bolus...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2015.0044
更新日期:2016-05-01 00:00:00
abstract:BACKGROUND:As healthy diet and physical activity can improve glucometabolic control in patients with type 2 diabetes, lifestyle changes should be the basis for each therapy. The only tool to visualize immediate effects of food pattern and exercise on blood glucose levels is self-monitoring of blood glucose (SMBG). Ther...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2010.0008
更新日期:2010-07-01 00:00:00
abstract:BACKGROUND:A brief history of the field of human factors research is covered, along with how this discipline is leveraged within medical device companies, to eliminate design flaws in products, in order to make them safe and effective for human use. The way in which human factors research was used to develop the t:slim...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究
doi:10.1089/dia.2013.0098
更新日期:2013-10-01 00:00:00
abstract:BACKGROUND:The efficacy of short-term professional continuous glucose monitoring (CGM) for glycemic control in patients with diabetes remains unclear. METHODS:We performed a 3-month study to evaluate the benefits of CGM in 64 patients. RESULTS:The overall glycemic control of patients who underwent CGM improved signif...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2018.0164
更新日期:2018-09-01 00:00:00
abstract:AIM:Insulin therapy induces remission in subjects with newly diagnosed type 2 diabetes mellitus (T2DM). This study assessed the insulin and C-peptide levels in newly diagnosed T2DM subjects during low-dose insulin therapy. SUBJECTS AND METHODS:Twenty newly diagnosed, drug-naive, T2DM patients without acute or chronic ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2010.0187
更新日期:2011-04-01 00:00:00
abstract:BACKGROUND:The Ascensia CONTOUR System (Bayer HealthCare LLC, Elkhart, IN) is a new blood glucose (BG) monitoring system (BGMS) that uses glucose dehydrogenase chemistry and that combines low sample volume, fast response time, an auto-control marking feature, and an auto-calibration function in a small package. METHOD...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究
doi:10.1089/dia.2005.7.283
更新日期:2005-04-01 00:00:00
abstract::This paper presents a critical review of continuous glucose monitoring studies that address accuracy, utility in assessing glucose variability, detection of hypoglycemia for improved metabolic control or reduced glucose variability, impact on quality of life, reduced fear of hypoglycemia, and applicability in helping ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2007.0261
更新日期:2008-04-01 00:00:00
abstract:OBJECTIVE:This study was designed to assess whether waist circumference can predict metabolic syndrome abnormalities in primary schoolchildren. RESEARCH DESIGN AND METHODS:Of 5,103 children (2,526 males) 4-13 years old who underwent anthropometric measurements, 530 had more extensive testing. Body mass index (BMI), wa...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究
doi:10.1089/dia.2006.0017
更新日期:2007-04-01 00:00:00
abstract:BACKGROUND:The junction of telemedicine home monitoring with multifaceted disease management programs seems nowadays a promising direction to combine the need for an intensive approach to deal with diabetes and the pressure to contain the costs of the interventions. Several projects in the European Union and the United...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2004.6.567
更新日期:2004-10-01 00:00:00
abstract:BACKGROUND:The recent availability of a continuous glucose monitor offers the opportunity to match the demands of intensive diabetes management with a period of equally intensive blood glucose monitoring. The present study evaluates the performance of the MiniMed continuous glucose monitoring system (CGMS) in patients ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/152091500316737
更新日期:2000-04-01 00:00:00
abstract:BACKGROUND:Narcolepsy is a severe sleep disorder that in most patients is characterized by the deficiency of central orexin. Clinically, narcolepsy is associated with obesity. Currently, there is a literature controversy about the potential alteration of leptin levels in narcoleptic patients. Theoretically, diminished ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2006.0037
更新日期:2007-08-01 00:00:00
abstract::It is widely accepted that noninvasive glucose monitoring (NIGM) has the potential to revolutionize diabetes therapy. However, current approaches to NIGM studied to date have not yet demonstrated a level of acceptable functionality to allow real-time use, beyond restricted fields of application. A number of reviews ha...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2009.0095
更新日期:2010-01-01 00:00:00
abstract::Skin integrity and diabetes device placement are ongoing concerns for people with diabetes who utilize continuous glucose monitors (CGMs) and continuous subcutaneous insulin infusion pumps. This is especially significant for individuals with skin sensitivities, pediatric patients, and those who use devices chronically...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2018.0080
更新日期:2018-06-01 00:00:00
abstract:BACKGROUND:Multicenter long-term studies of predictors for the effectiveness of continuous subcutaneous insulin infusion (CSII) in clinical practice are lacking. We hypothesized that there are substantially greater reductions in hemoglobin A1c (HbA1c) in patients with poor glycemic control and that other predictors may...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2014.0139
更新日期:2015-01-01 00:00:00
abstract:BACKGROUND:This exploratory study examined the pharmacokinetics and pharmacodynamics of a Bentley Pharmaceuticals, Inc. (North Hampton, NH) proprietary insulin formulation utilizing CPE-215 technology designed for intranasal administration. METHODS:Eight fasting healthy volunteers (four men, four women; body mass inde...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章
doi:10.1089/dia.2005.7.124
更新日期:2005-02-01 00:00:00
abstract::Current clinical guidelines for diabetes care encourage self-monitoring of blood glucose (SMBG) to improve glycemic control. Specific protocols remain variable, however, particularly among non-insulin-using patients. This is due in part to efficacy studies that neglect to consider (1) the performance of monitoring equ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2008.0104
更新日期:2008-12-01 00:00:00
abstract:BACKGROUND:This study was designed to assess the accuracy, reliability, and contribution to clinical decision-making of two commercially available continuous glucose monitoring (CGM) devices using a novel analytical approach. STUDY DESIGN:Eleven individuals with type 1 diabetes and five with type 2 diabetes wore a Gua...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2008.0041
更新日期:2009-01-01 00:00:00
abstract::Many people with insulin-treated diabetes continue to experience inadequate glycemic control and a high incidence of hypoglycemic events, despite improvements in therapeutic strategies. While glycated hemoglobin (HbA1c) is currently recognized as the gold-standard for assessing glycemic control, the measure reflects m...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2020.0180
更新日期:2021-01-01 00:00:00
abstract:BACKGROUND:Accurate and economic detection of nerve damage in diabetes is key to more widespread diagnosis of patients with diabetic peripheral neuropathy (DPN) and painful diabetic neuropathy. This study examined the diagnostic performance of NerveCheck, an inexpensive ($500) quantitative sensory testing (QST) device....
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2016.0279
更新日期:2016-12-01 00:00:00
abstract:BACKGROUND:Gestational diabetes mellitus (GDM) is associated with adverse perinatal outcomes, if not treated. International guidelines recommend screening "all or high-risk women" at the initial prenatal visit, when a fasting plasma glucose (FPG) between 92 and 126 mg/dL is diagnostic for GDM. However, glucose testing ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2011.0225
更新日期:2012-05-01 00:00:00
abstract:: Background: Continuous subcutaneous insulin infusion (CSII) is associated with improved glycemic control, a reduced incidence of hypoglycemia, and improved quality of life (QOL). To date, however, there has been no QOL scale specific to CSII. The objective of this study wa...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2019.0216
更新日期:2020-03-01 00:00:00
abstract:BACKGROUND:Diabetic foot ulcer area is a basic parameter used for monitoring the wound healing and effectiveness of the treatment applied. TeleDiaFoS (developed earlier in collaboration with the Department and Clinic of Gastroenterology and Metabolic Diseases, Medical University of Warsaw, Warsaw, Poland) is one of jus...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2011.0082
更新日期:2011-11-01 00:00:00
abstract:BACKGROUND:The value of self-monitoring of blood glucose (SMBG) for persons with type 2 diabetes who do not use insulin remains controversial. This observational study compares the likelihood of medication adherence and change in glycated hemoglobin (A1C) for non-insulin-using patients using SMBG versus those not using...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2012.0047
更新日期:2012-09-01 00:00:00
abstract:BACKGROUND:Glucose variability (GV) has been increasingly (or more extensively) studied in patients with type 1 diabetes (T1D) in the ambulatory setting; limited data exist on GV in hospitalized patients with T1D. MATERIALS AND METHODS:Retrospective single center cohort study, we analyzed in-hospital glucose measureme...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2017.0107
更新日期:2017-10-01 00:00:00
abstract::Empowerment plays significant roles in the complex management of type 2 diabetes. International guidelines have provided recommendations on management of Muslims who fast during Ramadan. However, there remains a lack of patient-centered epistemic tool to empower healthcare providers and patients in managing diabetes d...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2018.0159
更新日期:2018-10-01 00:00:00
abstract:BACKGROUND:Continuous glucose monitoring (CGM) time-series are often analyzed, retrospectively, to investigate glucose variability (GV), a risk factor for the development of complications in type 1 diabetes (T1D). In the literature, several tens of different indices for GV quantification have been proposed, but many of...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,meta分析
doi:10.1089/dia.2013.0252