The Impact of Short-Term Professional Continuous Glucose Monitoring on Glycemic Control Via Lifestyle Improvement.

Abstract:

BACKGROUND:The efficacy of short-term professional continuous glucose monitoring (CGM) for glycemic control in patients with diabetes remains unclear. METHODS:We performed a 3-month study to evaluate the benefits of CGM in 64 patients. RESULTS:The overall glycemic control of patients who underwent CGM improved significantly; however, that of patients maintaining the same medications did not improve overall. Thirty-one patients with unchanged medications were divided into improved (n = 12) versus nonimproved (n = 19) groups. In the improved group, baseline hemoglobin A1c (HbA1c) levels were higher than in the nonimproved group (P = 0.0066) despite mean blood glucose levels remaining the same (P = 0.3406). The improved group also exhibited lower glucose variability. CONCLUSIONS:Patients with lower than expected mean glucose levels, based on HbA1c values, and patients with lower glucose level variability during CGM may be able to improve their glycemic control after lifestyle change without treatment modification.

journal_name

Diabetes Technol Ther

authors

Shibusawa R,Yamada E,Okada S,Nakajima Y,Bastie CC,Yamada M

doi

10.1089/dia.2018.0164

subject

Has Abstract

pub_date

2018-09-01 00:00:00

pages

628-631

issue

9

eissn

1520-9156

issn

1557-8593

journal_volume

20

pub_type

杂志文章
  • Effectiveness of virtual reality using video gaming technology in elderly adults with diabetes mellitus.

    abstract:BACKGROUND:Diabetes in elderly adults is associated with an increased risk of fall. The aim of study was to determine whether a virtual reality exercise (VRE) program would improve balance, strength, gait, and falls efficacy in elderly adults with diabetes. SUBJECTS AND METHODS:Fifty-five subjects with diabetes mellit...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2013.0050

    authors: Lee S,Shin S

    更新日期:2013-06-01 00:00:00

  • Psychosocial correlates of continuous glucose monitoring use in youth and adults with type 1 diabetes and parents of youth.

    abstract:BACKGROUND:Continuous glucose monitoring (CGM) has been shown to improve glycemic control and reduce hypoglycemia with consistent use. Youth, however, are unlikely to use CGM consistently. We compared psychological characteristics of youth with type 1 diabetes, their parents, and adults with type 1 diabetes randomized ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2011.0201

    authors: Markowitz JT,Pratt K,Aggarwal J,Volkening LK,Laffel LM

    更新日期:2012-06-01 00:00:00

  • Evaluation of the Adherence to Continuous Glucose Monitoring in the Management of Type 1 Diabetes Patients on Sensor-Augmented Pump Therapy: The SENLOCOR Study.

    abstract:BACKGROUND:Continuous glucose monitoring (CGM) and sensor-augmented pump (SAP) therapy improve glucose control provided good adherence. In France, not only diabetologists, nurses, and dieticians but also nurses employed by homecare providers (HCPNs) are together involved in the initiation and/or follow-up of continuous...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究

    doi:10.1089/dia.2015.0240

    authors: Picard S,Hanaire H,Baillot-Rudoni S,Gilbert-Bonnemaison E,Not D,Reznik Y,Guerci B

    更新日期:2016-03-01 00:00:00

  • Resistance to Data Loss of Glycemic Variability Measurements in Long-Term Continuous Glucose Monitoring.

    abstract:: Background: Continuous glucose monitoring (CGM) is a method of estimating blood glucose values from those recorded in the interstitial fluid. Because increasingly longer CGM measurements are possible, errors and data loss become more and more likely and potentially more da...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0247

    authors: Kucharski P,Pagacz K,Szadkowska A,Młynarski W,Romanowski A,Fendler W

    更新日期:2018-12-01 00:00:00

  • Overcoming skin's barrier: the search for effective and user-friendly drug delivery.

    abstract::Although hypodermic needles rapidly deliver large doses of drugs such as insulin across the skin for systemic administration, the pain, local trauma, and difficulty to achieve sustained or complex delivery profiles has motivated development of novel alternative technologies. Microneedles, jet injectors, and thermal po...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/152091501300209606

    authors: Prausnitz MR

    更新日期:2001-07-01 00:00:00

  • The influence of environmental temperature on the response of the skin to local pressure: the impact of aging and diabetes.

    abstract:BACKGROUND:To protect against ischemia, pressure-induced vasodilation (PIV) causes an increase in skin blood flow. Endothelial dysfunction, which is commonly found in older patients and those with diabetes, and global temperatures can affect the resting blood flow in skin, which may reduce the blood flow during and aft...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2009.0097

    authors: McLellan K,Petrofsky JS,Zimmerman G,Lohman E,Prowse M,Schwab E,Lee S

    更新日期:2009-12-01 00:00:00

  • Design and Clinical Evaluation of the Interoperable Artificial Pancreas System (iAPS) Smartphone App: Interoperable Components with Modular Design for Progressive Artificial Pancreas Research and Development.

    abstract:BACKGROUND:There is an unmet need for a modular artificial pancreas (AP) system for clinical trials within the existing regulatory framework to further AP research projects from both academia and industry. We designed, developed, and tested the interoperable artificial pancreas system (iAPS) smartphone app that can int...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0278

    authors: Deshpande S,Pinsker JE,Zavitsanou S,Shi D,Tompot R,Church MM,Andre C,Doyle FJ 3rd,Dassau E

    更新日期:2019-01-01 00:00:00

  • Outpatient assessment of determinants of glucose excursions in adolescents with type 1 diabetes: proof of concept.

    abstract:UNLABELLED:Abstract Objective: Controlled inpatient studies on the effects of food, physical activity (PA), and insulin dosing on glucose excursions exist, but such outpatient data are limited. We report here outpatient data on glucose excursions and its key determinants over 5 days in 30 adolescents with type 1 diab...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2012.0053

    authors: Maahs DM,Mayer-Davis E,Bishop FK,Wang L,Mangan M,McMurray RG

    更新日期:2012-08-01 00:00:00

  • Interactive educational diabetes/insulin tutorial at www.2aida.info.

    abstract::The World Wide Web now hosts a multitude of diabetes educational materials in various formats. Of particular interest is the diabetes/insulin tutorial available at the AIDA Website (accessible directly at: www.2aida.info). The tutorial combines textual or "static" information with an interactive diabetes simulator-AID...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2006.8.126

    authors: Reed K,Lehmann ED

    更新日期:2006-02-01 00:00:00

  • Role of chronic and acute hyperglycemia in the development of diabetes complications.

    abstract::Chronic hyperglycemia, as assessed by hemoglobin A1c (HbA1c) levels, has been associated with the development of microvascular and macrovascular complications of diabetes. Several studies have shown that acute hyperglycemia can add to the effect of chronic hyperglycemia in inducing tissue damage. Acute hyperglycemia c...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2010.0146

    authors: Marcovecchio ML,Lucantoni M,Chiarelli F

    更新日期:2011-03-01 00:00:00

  • Clinical Practice Recommendations on the Routine Use of Eversense, the First Long-Term Implantable Continuous Glucose Monitoring System.

    abstract:: Background: The use of real-time continuous glucose monitoring (rtCGM) systems has proved to positively impact the management of type 1 diabetes with the potential to lower HbA1c, reduce frequency and time spent in hypoglycemia, and lower glycemic variability. Nevertheless...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0397

    authors: Deiss D,Szadkowska A,Gordon D,Mallipedhi A,Schütz-Fuhrmann I,Aguilera E,Ringsell C,De Block C,Irace C

    更新日期:2019-05-01 00:00:00

  • The Effects of Subcutaneous Insulin Infusion Versus Multiple Insulin Injections on Glucose Variability in Young Adults with Type 1 Diabetes: The 2-Year Follow-Up of the Observational METRO Study.

    abstract:BACKGROUND:Type 1 diabetic patients have high instability of daily glucose levels. The aim of this study was to evaluate the long-term effects of continuous subcutaneous insulin infusion (CSII) therapy, compared with multiple daily injections of insulin (MDI), on glucose variability, in young type 1 diabetic patients t...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2017.0334

    authors: Maiorino MI,Bellastella G,Casciano O,Cirillo P,Simeon V,Chiodini P,Petrizzo M,Gicchino M,Romano O,Caruso P,Giugliano D,Esposito K

    更新日期:2018-02-01 00:00:00

  • Development of optimal kids insulin dosing system formulas for young children with type 1 diabetes mellitus.

    abstract:OBJECTIVE:This study was designed to develop predictive formulas for precise insulin dosing in young children with type 1 diabetes (T1DM). RESEARCH DESIGN AND METHODS:Consecutive 1-year data from a group of 14 young patients (eight girls, six boys) 3.9 ± 0.8 years old with diabetes duration of 2.0 ± 0.8 years, transit...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2011.0184

    authors: Alemzadeh R,Hoffmann RG,Dasgupta M,Parton E

    更新日期:2012-05-01 00:00:00

  • Development and Validation of the Continuous Subcutaneous Insulin Infusion-Related Quality-of-Life (CSII-QOL) Scale.

    abstract:: Background: Continuous subcutaneous insulin infusion (CSII) is associated with improved glycemic control, a reduced incidence of hypoglycemia, and improved quality of life (QOL). To date, however, there has been no QOL scale specific to CSII. The objective of this study wa...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2019.0216

    authors: Sakane N,Murata T,Tone A,Kato K,Kimura M,Kawashima S,Sawaki H,Hirota Y,Okada A,Kuroda A,Matsuhisa M,Watanabe T,Suganuma A,Nirengi S,Toyoda M

    更新日期:2020-03-01 00:00:00

  • Improved Postprandial Glycemic Control with Faster-Acting Insulin Aspart in Patients with Type 1 Diabetes Using Continuous Subcutaneous Insulin Infusion.

    abstract:BACKGROUND:Faster aspart is insulin aspart (IAsp) in a new formulation, which in continuous subcutaneous insulin infusion (CSII) in subjects with type 1 diabetes has shown a faster onset and offset of glucose-lowering effect than IAsp. METHODS:This double-blind, randomized, crossover active-controlled trial compared 2...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2016.0350

    authors: Bode BW,Johnson JA,Hyveled L,Tamer SC,Demissie M

    更新日期:2017-01-01 00:00:00

  • Metrics to Evaluate Quality of Glycemic Control: Comparison of Time in Target, Hypoglycemic, and Hyperglycemic Ranges with "Risk Indices".

    abstract:OBJECTIVE:We sought to cross validate several metrics for quality of glycemic control, hypoglycemia, and hyperglycemia. RESEARCH DESIGN AND METHODS:We analyzed the mathematical properties of several metrics for overall glycemic control, and for hypo- and hyperglycemia, to evaluate their similarities, differences, and ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2017.0416

    authors: Rodbard D

    更新日期:2018-05-01 00:00:00

  • Predicting the effectiveness of insulin pump therapy on glycemic control in clinical practice: a retrospective study of patients with type 1 diabetes from 10 outpatient diabetes clinics in Sweden over 5 years.

    abstract:BACKGROUND:Multicenter long-term studies of predictors for the effectiveness of continuous subcutaneous insulin infusion (CSII) in clinical practice are lacking. We hypothesized that there are substantially greater reductions in hemoglobin A1c (HbA1c) in patients with poor glycemic control and that other predictors may...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2014.0139

    authors: Clements M,Matuleviciene V,Attvall S,Ekelund M,Pivodic A,Dahlqvist S,Fahlén M,Haraldsson B,Lind M

    更新日期:2015-01-01 00:00:00

  • Differences in exhaled gas profiles between patients with type 2 diabetes and healthy controls.

    abstract:AIMS:Recent advances in analytical technology allow the detection of several hundred volatile organic compounds (VOCs) in human exhaled air, many of which reflect unidentified endogenous pathways. This study was performed to determine whether a breath gas analysis using proton transfer reaction-mass spectrometry (PTR-M...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2009.0181

    authors: Greiter MB,Keck L,Siegmund T,Hoeschen C,Oeh U,Paretzke HG

    更新日期:2010-06-01 00:00:00

  • Randomized Evaluation of Glycemic Control in the Medical Intensive Care Unit Using Real-Time Continuous Glucose Monitoring (REGIMEN Trial).

    abstract:BACKGROUND AND OBJECTIVE:Hyperglycemia occurs commonly in patients admitted to medical intensive care units (MICUs). Whether real-time (RT) continuous glucose monitoring (CGM) improves glycemic control and variability and reduces hypoglycemia in severely ill MICU patients with an Acute Physiology and Chronic Health Eva...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1089/dia.2015.0151

    authors: De Block CE,Gios J,Verheyen N,Manuel-y-Keenoy B,Rogiers P,Jorens PG,Scuffi C,Van Gaal LF

    更新日期:2015-12-01 00:00:00

  • Patients' perceptions of subcutaneous insulin in the OPTIMIZE study: a multicenter follow-up study.

    abstract:BACKGROUND:The Optimizing Control in Diabetes (OPTIMIZE) survey was conducted to understand the patients' perspective to achieving good glycemic control and to determine how patients' perceptions of insulin may affect their decisions to initiate or intensify their insulin therapy. METHODS:A total of 1,444 subjects wit...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究

    doi:10.1089/dia.2008.0249

    authors: Cefalu WT,Mathieu C,Davidson J,Freemantle N,Gough S,Canovatchel W,OPTIMIZE Coalition.

    更新日期:2008-02-01 00:00:00

  • Biochemical stabilization of glucagon at alkaline pH.

    abstract:BACKGROUND:For patients with type 1 diabetes mellitus, a bihormonal artificial endocrine pancreas system utilizing glucagon and insulin has been found to stabilize glycemic control. However, commercially available formulations of glucagon cannot currently be used in such systems because of physical instability characte...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2014.0047

    authors: Caputo N,Jackson MA,Castle JR,El Youssef J,Bakhtiani PA,Bergstrom CP,Carroll JM,Breen ME,Leonard GL,David LL,Roberts CT Jr,Ward WK

    更新日期:2014-11-01 00:00:00

  • In vivo glucose monitoring using dual-wavelength polarimetry to overcome corneal birefringence in the presence of motion.

    abstract:OBJECTIVE:Over the past 35 years considerable research has been performed toward the investigation of noninvasive and minimally invasive glucose monitoring techniques. Optical polarimetry is one noninvasive technique that has shown promise as a means to ascertain blood glucose levels through measuring the glucose conce...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2012.0070

    authors: Pirnstill CW,Malik BH,Gresham VC,Coté GL

    更新日期:2012-09-01 00:00:00

  • Efficacy and Safety of Biosimilar SAR342434 Insulin Lispro in Adults with Type 1 Diabetes Also Using Insulin Glargine-SORELLA 1 Study.

    abstract:BACKGROUND:SAR342434 is a biosimilar follow-on of insulin lispro-Humalog®. This study aimed to show similar efficacy, safety, and immunogenicity of SAR342434 (SAR-Lis) versus insulin lispro-Humalog (Ly-Lis) in adult patients with type 1 diabetes (T1DM) treated with multiple daily injections while using basal insulin gl...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1089/dia.2017.0117

    authors: Garg SK,Wernicke-Panten K,Rojeski M,Pierre S,Kirchhein Y,Jedynasty K

    更新日期:2017-09-01 00:00:00

  • Description and preliminary evaluation of a Multiagent Intelligent Dosing System (MAIDS) to manage combination insulin-oral agent therapy in type 2 diabetes.

    abstract:BACKGROUND:Computer decision support systems are potentially effective methods for adjusting insulin, but current models do not take into account simultaneous changes of more than one agent. We describe the development of the Multiagent Intelligent Dosing System (MAIDS, Dimensional Dosing Systems, Wexford, PA) for pred...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2005.7.937

    authors: Cook CB,McMichael JP,Dunbar VG,Lieberman R

    更新日期:2005-12-01 00:00:00

  • ROSSO-in-praxi: a self-monitoring of blood glucose-structured 12-week lifestyle intervention significantly improves glucometabolic control of patients with type 2 diabetes mellitus.

    abstract:BACKGROUND:As healthy diet and physical activity can improve glucometabolic control in patients with type 2 diabetes, lifestyle changes should be the basis for each therapy. The only tool to visualize immediate effects of food pattern and exercise on blood glucose levels is self-monitoring of blood glucose (SMBG). Ther...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2010.0008

    authors: Kempf K,Kruse J,Martin S

    更新日期:2010-07-01 00:00:00

  • Continuous glucose monitoring pilot in low-income type 1 diabetes patients.

    abstract:BACKGROUND:Continuous glucose monitoring (CGM) has been shown to be a valuable tool to improve glycemic control in patients with diabetes. The objective of this pilot study was to develop and implement CGM in an existing diabetes clinic for low-income patients on multiple daily injections. SUBJECTS AND METHODS:This wa...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2013.0072

    authors: Sequeira PA,Montoya L,Ruelas V,Xing D,Chen V,Beck R,Peters AL

    更新日期:2013-10-01 00:00:00

  • Safety and Efficacy of Initializing the Control-IQ Artificial Pancreas System Based on Total Daily Insulin in Adolescents with Type 1 Diabetes.

    abstract:: Objective: To assess the safety and efficacy of a simplified initialization for the Tandem t:slim X2 Control-IQ hybrid closed-loop system, using parameters based on total daily insulin ("MyTDI") in adolescents with type 1 diabetes under usual activity and during periods of...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2019.0471

    authors: Schoelwer MJ,Robic JL,Gautier T,Fabris C,Carr K,Clancy-Oliveri M,Brown SA,Anderson SM,DeBoer MD,Cherñavvsky DR,Breton MD

    更新日期:2020-08-01 00:00:00

  • Behavioral Patterns and Associations with Glucose Control During 12-Week Randomized Free-Living Clinical Trial of Day and Night Hybrid Closed-Loop Insulin Delivery in Adults with Type 1 Diabetes.

    abstract:OBJECTIVES:We evaluated patterns of meal intake, insulin bolus delivery, and fingerstick glucose measurements during hybrid closed-loop and sensor-augmented pump (SAP) therapy, including associations with glucose control. METHODS:Data were retrospectively analyzed from pump-treated adults with type 1 diabetes who unde...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2016.0307

    authors: Emami A,Willinska ME,Thabit H,Leelarathna L,Hartnell S,Dellweg S,Benesch C,Mader JK,Holzer M,Kojzar H,Pieber TR,Arnolds S,Evans ML,Hovorka R

    更新日期:2017-07-01 00:00:00

  • Family perceptions of insulin pump adverse events in children and adolescents.

    abstract:BACKGROUND:Insulin pumps (for continuous subcutaneous insulin infusion [CSII]) are used widely in type 1 diabetes mellitus. Although there has been considerable study of outcomes, there are few recent data on CSII-associated adverse events and no data on family perceptions of adverse events and their confidence in deal...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2013.0315

    authors: Wheeler BJ,Donaghue KC,Heels K,Ambler GR

    更新日期:2014-04-01 00:00:00

  • Efficacy and safety performance of the Innovo insulin doser.

    abstract::Innovo (Novo Nordisk A/S, Hillerød, Denmark) is a new insulin injection system that offers built-in memory and a large, clear display to provide patients with more control during insulin injections. The aim of this trial was to compare the efficacy and safety of Innovo and NovoPen 3 (Novo Nordisk A/S) in patients expe...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1089/152091504322783413

    authors: Valk NK,Cerny G,Sieber J,Lytzen L,Berg B

    更新日期:2004-02-01 00:00:00