Abstract:
BACKGROUND:Diabetes in elderly adults is associated with an increased risk of fall. The aim of study was to determine whether a virtual reality exercise (VRE) program would improve balance, strength, gait, and falls efficacy in elderly adults with diabetes. SUBJECTS AND METHODS:Fifty-five subjects with diabetes mellitus over 65 years of age were randomly assigned to a VRE group (VREG) (n=27) and a control group (CG) (n=28). The VREG received the VRE program and diabetes education, whereas the CG received only the diabetes education. The VRE program used video gaming (PlayStation(®) 2; Sony, Tokyo, Japan) and was conducted for 50 min twice a week for 10 weeks. Balance, muscle strength, gait, and falls efficacy were measured at baseline and after intervention. Measurements were taken using a clinical tests (the one-leg-standing test, the Berg Balance Scale, the functional reach test, the timed up-and-go test, and the sit-to-stand test), and gait analysis. A self-administered questionnaire was used to measure falls efficacy. RESULTS:After training, the VREG showed significantly improved balance, decreased sit-to-stand times, and increased gait speed, cadence, and falls efficacy. CONCLUSIONS:The VRE program was to maximize the effects of exercise by triggering players was to be fully immersed into the games and enhanced major influential factors on the falls of subject. This study suggests VRE programs are feasible and effective for reduced the risk of falls in elderly adults with type 2 diabetes.
journal_name
Diabetes Technol Therjournal_title
Diabetes technology & therapeuticsauthors
Lee S,Shin Sdoi
10.1089/dia.2013.0050subject
Has Abstractpub_date
2013-06-01 00:00:00pages
489-96issue
6eissn
1520-9156issn
1557-8593journal_volume
15pub_type
杂志文章,随机对照试验abstract:BACKGROUND:During the proteomic era, one of the most rapidly growing areas in biomedical research is biomarker discovery, particularly using proteomic technologies. The urinary proteome is known to be a valuable field of study and has become one of the most attractive subdisciplines in clinical proteomics for human dis...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2010.0078
更新日期:2010-12-01 00:00:00
abstract:AIMS:The aim was to investigate the prevalence of diabetic sensorimotor polyneuropathy (DSPN) and cardiovascular autonomic neuropathy (CAN) in a Danish population of young adults with type 1 diabetes (T1D) using both established and novel measuring modalities. Furthermore, to investigate the association between continu...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2018.0249
更新日期:2018-11-21 00:00:00
abstract:OBJECTIVE:Exercise is a cornerstone of diabetes therapy in type 1 diabetes mellitus (DMT1) patients. The type of exercise is important in determining the propensity to hypoglycemia. We assessed, by continuous glucose monitoring (CGM), the glucose profiles during and in the following 20h after a session of two different...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1089/dia.2010.0038
更新日期:2010-10-01 00:00:00
abstract:AIMS:This study assessed patient-reported outcomes in a multicenter study of adults with type 2 diabetes taking mealtime Technosphere(®) inhaled insulin (MannKind Corp., Valencia, CA) and basal insulin (insulin glargine) or premixed aspart insulin 70/30. METHODS:Subjects were 618 non-smoking adults with starting hemog...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章,多中心研究,随机对照试验
doi:10.1089/dia.2011.0037
更新日期:2011-12-01 00:00:00
abstract::Existing standards of the management of the diabetic patients are not efficient enough, and further improvement is needed. The major objective of this paper is to present and discuss the therapeutic effectiveness of an intensive care telematic system designed and applied for intensive treatment of pregnant type 1 diab...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章
doi:10.1089/15209150152811207
更新日期:2001-01-01 00:00:00
abstract:BACKGROUND:The objective of this investigation was to evaluate the test-retest repeatability of insulin sensitivity and secretion indices derived from liquid meal tolerance tests (MTTs) in subjects with normal fasting glucose (NFG) (n = 20), impaired fasting glucose (IFG) (n = 20), or type 2 diabetes mellitus (n = 38)....
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2010.0083
更新日期:2010-11-01 00:00:00
abstract:BACKGROUND:This exploratory study examined the pharmacokinetics and pharmacodynamics of a Bentley Pharmaceuticals, Inc. (North Hampton, NH) proprietary insulin formulation utilizing CPE-215 technology designed for intranasal administration. METHODS:Eight fasting healthy volunteers (four men, four women; body mass inde...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章
doi:10.1089/dia.2005.7.124
更新日期:2005-02-01 00:00:00
abstract::Chronic hyperglycemia, as assessed by hemoglobin A1c (HbA1c) levels, has been associated with the development of microvascular and macrovascular complications of diabetes. Several studies have shown that acute hyperglycemia can add to the effect of chronic hyperglycemia in inducing tissue damage. Acute hyperglycemia c...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2010.0146
更新日期:2011-03-01 00:00:00
abstract:BACKGROUND:Preventing the complications of diabetes requires tight control and minimizing blood glucose fluctuation. Pursuing these goals increases the risk of severe hypoglycemia. The authors hoped to identify if using continuous glucose monitoring (CGM) decreased the incidence of severe hypoglycemia, resulted in less...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2009.0121
更新日期:2010-03-01 00:00:00
abstract:BACKGROUND:Glutamic acid decarboxylase-65 (GAD65) is a major autoantigen in autoimmune diabetes and is discharged from injured islet beta cells. GAD65 may also be released by transplanted islets undergoing immunological rejection. To test hypotheses regarding the utility of GAD65 as a biomarker for transplant rejection...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2006.8.207
更新日期:2006-04-01 00:00:00
abstract:BACKGROUND:Pregnancy and early motherhood are extraordinarily demanding periods for women with type 1 diabetes, who therefore need optimal support. This article describes the process of developing person-centered Web-based support for women with type 1 diabetes during the period of pregnancy through early motherhood. I...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2012.0217
更新日期:2013-01-01 00:00:00
abstract:BACKGROUND:Microneedles have previously been used to deliver insulin to animal models, but not in human subjects. This study tested the hypothesis that hollow microneedles can deliver insulin to modulate blood glucose levels in subjects with type 1 diabetes in a minimally invasive manner. METHODS:This study was carrie...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2008.0103
更新日期:2009-06-01 00:00:00
abstract:BACKGROUND:Continuous glucose monitoring (CGM) provides glucose trend information that can be used to guide treatment and motivate patients with diabetes. Currently, the evidence on effectiveness of CGM in patients with type 2 diabetes is debatable. We aim to provide a systematic review and meta-analysis to synthesize ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,meta分析
doi:10.1089/dia.2018.0177
更新日期:2018-09-01 00:00:00
abstract:BACKGROUND:This article reports a prolonged trial with insulin pumps implanted in patients with type 1 diabetes showing poor glucose control and a high rate of complications. METHODS:We reviewed data from 181 patients undergoing implanted insulin pump therapy. Analysis included hemoglobin A1c (HbA1c) values, body weig...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2010.0209
更新日期:2011-06-01 00:00:00
abstract:BACKGROUND:There are currently few data available on the long-term use of continuous subcutaneous insulin infusion (CSII) (insulin pump) therapy in children. METHODS:Charts from 291 youth with type 1 diabetes (T1D) who were treated with CSII therapy for at least 1 year were reviewed. Data analysis included hemoglobin ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2007.0214
更新日期:2007-10-01 00:00:00
abstract:AIMS:This study compared glycemic control and maternal and fetal outcomes in pregnant women with type 1 diabetes mellitus (T1DM) treated with multiple daily injections (MDI) or continuous subcutaneous insulin infusion (CSII) using regular (RI) or lispro (LP) insulin. METHODS:Three hundred fifteen consecutive singleton...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2010.0111
更新日期:2010-12-01 00:00:00
abstract::Continuous glucose monitoring (CGM) is a new tool that has recently become available to people with diabetes. Properly designing and conducting trials in order to answer important questions regarding the clinical usefulness of CGM is very difficult and fraught with many confounding variables and unique challenges. Ini...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2009.0012
更新日期:2009-06-01 00:00:00
abstract:AIMS:Recent advances in analytical technology allow the detection of several hundred volatile organic compounds (VOCs) in human exhaled air, many of which reflect unidentified endogenous pathways. This study was performed to determine whether a breath gas analysis using proton transfer reaction-mass spectrometry (PTR-M...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2009.0181
更新日期:2010-06-01 00:00:00
abstract:: Background: The prevalence of diabetes in youth is increasing worldwide in parallel with the obesity epidemic. This study aimed to determine the incidence rates of dysglycemia (diabetes or prediabetes) and evaluate the predictors of its progression or regression to normal ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2020.0109
更新日期:2020-12-01 00:00:00
abstract::The World Wide Web now hosts a multitude of diabetes educational materials in various formats. Of particular interest is the diabetes/insulin tutorial available at the AIDA Website (accessible directly at: www.2aida.info). The tutorial combines textual or "static" information with an interactive diabetes simulator-AID...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2006.8.126
更新日期:2006-02-01 00:00:00
abstract:BACKGROUND:Understanding the effect size, variability, and underlying physiology of the dawn phenomenon is important for next-generation closed-loop control algorithms for type 1 diabetes (T1D). SUBJECTS AND METHODS:We used an iterative protocol design to study 16 subjects with T1D on individualized insulin pump thera...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2015.0011
更新日期:2015-08-01 00:00:00
abstract:BACKGROUND:There is no consensus as to the best method to assess glycemic variability from continuous glucose monitoring (CGM) data. Rate of change has been suggested as a preferred method of assessing glycemic variability, but this assertion has not been validated. METHODS:Forty-eight hours of CGM data were analyzed ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究
doi:10.1089/dia.2010.0215
更新日期:2011-06-01 00:00:00
abstract:BACKGROUND:Different reference methods are used for the accuracy assessment of continuous glucose monitoring (CGM) systems. The effect of using venous, arterialized-venous, or capillary reference measurements on CGM accuracy is unclear. METHODS:We evaluated 21 individuals with type 1 diabetes using a capillary calibra...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2017.0189
更新日期:2017-11-01 00:00:00
abstract:: Background: Current manual diabetic retinopathy (DR) screening using eye care experts cannot scale to screen the growing population of diabetes patients who are at risk for vision loss. EyeArt system is an automated, cloud-based artificial intelligence (AI) eye screening t...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2019.0164
更新日期:2019-11-01 00:00:00
abstract::Treatments for type 1 diabetes have advanced significantly over recent years. There are now multiple hybrid closed-loop systems commercially available and additional systems are in development. Challenges remain, however. This review outlines the recent advances in closed-loop systems and outlines the remaining challe...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2019.0469
更新日期:2020-07-01 00:00:00
abstract:BACKGROUND:The optimal treatment of diabetes in pregnancy requires accurate measurement of blood glucose levels, in order to minimize adverse outcomes for both mother and neonate. Self-monitoring of blood glucose is routinely used to measure glycemic control and to assess whether treatment targets are being met; howeve...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,收录出版
doi:10.1089/dia.2015.0104
更新日期:2016-02-01 00:00:00
abstract:BACKGROUND:Children with positive islet autoantibodies monitored prospectively avoid metabolic decompensation at type 1 diabetes (T1D) diagnosis. However, the effects of early diagnosis and treatment on preservation of insulin secretion and long-term metabolic control are unknown. We compared characteristics of childre...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2015.0029
更新日期:2015-09-01 00:00:00
abstract::It is becoming increasingly acknowledged that people with Type 2 Diabetes represent what can be termed "an enriched population": a group that has the greatest risk of morbidity and mortality from cardiovascular diseases such as myocardial infarcts and strokes. Due to the tremendous toll, both human and financial, that...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/15209150050025258
更新日期:2000-07-01 00:00:00
abstract::With the expiration of patent protection for several originator insulin analog molecules, the availability of insulin analog copies is set to increase. Many regulatory authorities have developed, and continue to refine, guidelines for the approval of biosimilar insulin analogs. Aspects such as the structure, pharmacok...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2016.0263
更新日期:2017-02-01 00:00:00
abstract:BACKGROUND:We assessed the impact of using an automated bolus advisor integrated into a blood glucose meter on the timing and frequency of adjusting insulin therapy parameter settings and whether the availability of this technology would increase blood glucose test strip utilization in diabetes patients treated with mu...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1089/dia.2013.0280
更新日期:2014-05-01 00:00:00