Continuous glucose monitoring and diabetes health outcomes: a critical appraisal.

Abstract:

:This paper presents a critical review of continuous glucose monitoring studies that address accuracy, utility in assessing glucose variability, detection of hypoglycemia for improved metabolic control or reduced glucose variability, impact on quality of life, reduced fear of hypoglycemia, and applicability in helping patients to overcome their reluctance to intensify insulin therapy. This analysis can be used to delineate the evidence that is still missing when considering continuous glucose monitoring as an established tool in clinical practice and for reimbursement of the system and services.

journal_name

Diabetes Technol Ther

authors

Reach G

doi

10.1089/dia.2007.0261

subject

Has Abstract

pub_date

2008-04-01 00:00:00

pages

69-80

issue

2

eissn

1520-9156

issn

1557-8593

journal_volume

10

pub_type

杂志文章,评审
  • Intervention trials for prevention of metabolic syndrome and type 2 diabetes: focus on Asian Indians.

    abstract::Prevalence of diabetes continues to increase in urban areas, and escalation is discernible in semi-urban and rural areas. It is reported to affect Asian Indians a decade earlier compared with other populations, and complications (e.g., nephropathy) occur earlier and are severe and more prevalent than in other races. B...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2013.0373

    authors: Shrivastava U,Misra A

    更新日期:2014-08-01 00:00:00

  • Outpatient assessment of determinants of glucose excursions in adolescents with type 1 diabetes: proof of concept.

    abstract:UNLABELLED:Abstract Objective: Controlled inpatient studies on the effects of food, physical activity (PA), and insulin dosing on glucose excursions exist, but such outpatient data are limited. We report here outpatient data on glucose excursions and its key determinants over 5 days in 30 adolescents with type 1 diab...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2012.0053

    authors: Maahs DM,Mayer-Davis E,Bishop FK,Wang L,Mangan M,McMurray RG

    更新日期:2012-08-01 00:00:00

  • The Effects of Subcutaneous Insulin Infusion Versus Multiple Insulin Injections on Glucose Variability in Young Adults with Type 1 Diabetes: The 2-Year Follow-Up of the Observational METRO Study.

    abstract:BACKGROUND:Type 1 diabetic patients have high instability of daily glucose levels. The aim of this study was to evaluate the long-term effects of continuous subcutaneous insulin infusion (CSII) therapy, compared with multiple daily injections of insulin (MDI), on glucose variability, in young type 1 diabetic patients t...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2017.0334

    authors: Maiorino MI,Bellastella G,Casciano O,Cirillo P,Simeon V,Chiodini P,Petrizzo M,Gicchino M,Romano O,Caruso P,Giugliano D,Esposito K

    更新日期:2018-02-01 00:00:00

  • Basal plus basal-bolus approach in type 2 diabetes.

    abstract::Type 2 diabetes is characterized by insulin resistance and progressive β-cell deterioration. As β-cell function declines, most patients with type 2 diabetes treated with oral agents, in monotherapy or combination, will require insulin therapy. Addition of basal insulin (glargine, detemir, or NPH/neutral protamine lisp...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2011.0001

    authors: Ampudia-Blasco FJ,Rossetti P,Ascaso JF

    更新日期:2011-06-01 00:00:00

  • Efficacy and Tolerability of Exenatide Once Weekly Over 6 Years in Patients with Type 2 Diabetes: An Uncontrolled Open-Label Extension of the DURATION-1 Study.

    abstract:BACKGROUND:Long-term treatment is necessary to slow the progression of type 2 diabetes (T2D). Here, we examined the safety and efficacy of 6 years of treatment with exenatide once weekly (QW) among patients with T2D in the DURATION-1 trial. METHODS:The study enrolled patients aged ≥16 years with T2D treated primarily ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章

    doi:10.1089/dia.2016.0107

    authors: Henry RR,Klein EJ,Han J,Iqbal N

    更新日期:2016-11-01 00:00:00

  • Daily glucose profiles in Japanese people with normal glucose tolerance as assessed by continuous glucose monitoring.

    abstract:BACKGROUND:Little information is available regarding glucose fluctuations in postprandial states and during the oral glucose tolerance test (OGTT) in Japanese people with normal glucose tolerance (NGT). METHODS:Glucose profiles of 27 Japanese people were measured for 4 days by using continuous glucose monitoring. A 75...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2008.0083

    authors: Tsujino D,Nishimura R,Taki K,Miyashita Y,Morimoto A,Tajima N

    更新日期:2009-07-01 00:00:00

  • Personal glycation factors and calculated HbA1c for diabetes management: Real-world data from the DPV registry.

    abstract::Background Glycated hemoglobin A1c (HbA1c) is a key biomarker in the glycemic management of individuals with diabetes but the relationship with glucose levels can be variable. A recent kinetic model has described a calculated HbA1c (cHbA1c) that is individual-specific. Our aim was to validate the routine clinical use ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2020.0553

    authors: Xu Y,Grimsmann JM,Karges B,Hofer SE,Danne T,Holl RW,Ajjan RA,Dunn TD

    更新日期:2021-01-04 00:00:00

  • Effects of sleep apnea severity on glycemic control in patients with type 2 diabetes prior to continuous positive airway pressure treatment.

    abstract:BACKGROUND:Obstructive sleep apnea (OSA), a highly prevalent condition, is independently associated with increased risks of developing type 2 diabetes mellitus (T2D) and metabolic syndrome. It is unclear, however, if the severity of OSA has any impact on glycemic control among patients with T2D. We therefore aimed to d...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2011.0005

    authors: Pillai A,Warren G,Gunathilake W,Idris I

    更新日期:2011-09-01 00:00:00

  • Evaluation of Blood Glucose Meter Efficacy in an Antenatal Diabetes Clinic.

    abstract:BACKGROUND:The optimal treatment of diabetes in pregnancy requires accurate measurement of blood glucose levels, in order to minimize adverse outcomes for both mother and neonate. Self-monitoring of blood glucose is routinely used to measure glycemic control and to assess whether treatment targets are being met; howeve...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,收录出版

    doi:10.1089/dia.2015.0104

    authors: McGrath RT,Donnelly VC,Glastras SJ,Preda VA,Sheriff N,Ward P,Hocking SL,Fulcher GR

    更新日期:2016-02-01 00:00:00

  • Comparison of Metabolic Outcomes in Children Diagnosed with Type 1 Diabetes Through Research Screening (Diabetes Autoimmunity Study in the Young [DAISY]) Versus in the Community.

    abstract:BACKGROUND:Children with positive islet autoantibodies monitored prospectively avoid metabolic decompensation at type 1 diabetes (T1D) diagnosis. However, the effects of early diagnosis and treatment on preservation of insulin secretion and long-term metabolic control are unknown. We compared characteristics of childre...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2015.0029

    authors: Chan CL,Taki I,Dong F,Hoffman M,Norris JM,Klingensmith G,Rewers MJ,Steck AK

    更新日期:2015-09-01 00:00:00

  • Randomized Evaluation of Glycemic Control in the Medical Intensive Care Unit Using Real-Time Continuous Glucose Monitoring (REGIMEN Trial).

    abstract:BACKGROUND AND OBJECTIVE:Hyperglycemia occurs commonly in patients admitted to medical intensive care units (MICUs). Whether real-time (RT) continuous glucose monitoring (CGM) improves glycemic control and variability and reduces hypoglycemia in severely ill MICU patients with an Acute Physiology and Chronic Health Eva...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1089/dia.2015.0151

    authors: De Block CE,Gios J,Verheyen N,Manuel-y-Keenoy B,Rogiers P,Jorens PG,Scuffi C,Van Gaal LF

    更新日期:2015-12-01 00:00:00

  • Noninvasive continuous glucose monitoring using photoacoustic technology-results from the first 62 subjects.

    abstract:BACKGROUND:Continuous glucose monitoring is a useful tool for the achievement of improved glucose control in patients with diabetes. We tested the ability of a novel noninvasive continuous glucose monitor to track glucose excursions. METHODS:The novel noninvasive Aprise sensor (Glucon Inc., Boulder, CO) utilizes the p...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章

    doi:10.1089/dia.2006.0059

    authors: Weiss R,Yegorchikov Y,Shusterman A,Raz I

    更新日期:2007-02-01 00:00:00

  • Continuous Subcutaneous Insulin Infusion in Neonates and Infants Below 1 Year: Analysis of Initial Bolus and Basal Rate Based on the Experiences from the German Working Group for Pediatric Pump Treatment.

    abstract:BACKGROUND:Diabetes mellitus is rare in young infants and neonates. Continuous subcutaneous insulin infusion (CSII) is used most frequently for insulin treatment in this age group. However, the individual doctor's experience is scarce because of the low prevalence of diabetes in this age. For this study patients treate...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究

    doi:10.1089/dia.2015.0030

    authors: Kapellen TM,Heidtmann B,Lilienthal E,Rami-Merhar B,Engler-Schmidt C,Holl RW

    更新日期:2015-12-01 00:00:00

  • Waist circumference identifies primary school children with metabolic syndrome abnormalities.

    abstract:OBJECTIVE:This study was designed to assess whether waist circumference can predict metabolic syndrome abnormalities in primary schoolchildren. RESEARCH DESIGN AND METHODS:Of 5,103 children (2,526 males) 4-13 years old who underwent anthropometric measurements, 530 had more extensive testing. Body mass index (BMI), wa...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究

    doi:10.1089/dia.2006.0017

    authors: Hirschler V,Maccallini G,Calcagno M,Aranda C,Jadzinsky M

    更新日期:2007-04-01 00:00:00

  • The emergence of biosimilar insulin preparations--a cause for concern?

    abstract::Several biopharmaceuticals, including insulin and insulin analogs, are, or shortly will be, off-patent, thereby providing an opportunity for companies to attempt to manufacture "copies" commonly referred to as biosimilars and also known as follow-on biologics. Reassurance that such copy biologics are equally safe and ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2012.0105

    authors: Owens DR,Landgraf W,Schmidt A,Bretzel RG,Kuhlmann MK

    更新日期:2012-11-01 00:00:00

  • Feasibility Study of a Hybrid Closed-Loop System with Automated Insulin Correction Boluses.

    abstract:: Background: The Medtronic MiniMed™ 670G system adjusts basal insulin delivery in response to continuous glucose monitoring levels and is already in use in clinical practice. We tested the home-based feasibility of the new MiniMed advanced hybrid closed-loop (AHCL) system, ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2020.0448

    authors: Nimri R,Grosman B,Roy A,Nir J,Fisch Shvalb N,Kurtz N,Loewenthal N,Gillon-Keren M,Muller I,Atlas E,Phillip M

    更新日期:2020-12-08 00:00:00

  • Reduced weight gain with insulin detemir compared to NPH insulin is not explained by a reduction in hypoglycemia.

    abstract:BACKGROUND:Weight gain often occurs when insulin therapy is initiated. The long-acting insulin analog insulin detemir has been shown to be effective and well tolerated when used in basal-bolus regimens or as an add-on to oral antidiabetic drugs (OADs) and causes less weight gain than other insulins. The aim of this exp...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1089/dia.2008.0282

    authors: Davies MJ,Derezinski T,Pedersen CB,Clauson P

    更新日期:2008-08-01 00:00:00

  • Evaluation of the Adherence to Continuous Glucose Monitoring in the Management of Type 1 Diabetes Patients on Sensor-Augmented Pump Therapy: The SENLOCOR Study.

    abstract:BACKGROUND:Continuous glucose monitoring (CGM) and sensor-augmented pump (SAP) therapy improve glucose control provided good adherence. In France, not only diabetologists, nurses, and dieticians but also nurses employed by homecare providers (HCPNs) are together involved in the initiation and/or follow-up of continuous...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究

    doi:10.1089/dia.2015.0240

    authors: Picard S,Hanaire H,Baillot-Rudoni S,Gilbert-Bonnemaison E,Not D,Reznik Y,Guerci B

    更新日期:2016-03-01 00:00:00

  • Variability of insulin absorption and insulin action.

    abstract::Subcutaneous (s.c.) injections of identical insulin doses may lead to considerable intra- and inter-individual differences in the current metabolic control of patients with diabetes mellitus. This well-known variability of the metabolic effect of insulin hampers practical insulin therapy considerably. The aim of this ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/152091502320798312

    authors: Heinemann L

    更新日期:2002-01-01 00:00:00

  • Development of optimal kids insulin dosing system formulas for young children with type 1 diabetes mellitus.

    abstract:OBJECTIVE:This study was designed to develop predictive formulas for precise insulin dosing in young children with type 1 diabetes (T1DM). RESEARCH DESIGN AND METHODS:Consecutive 1-year data from a group of 14 young patients (eight girls, six boys) 3.9 ± 0.8 years old with diabetes duration of 2.0 ± 0.8 years, transit...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2011.0184

    authors: Alemzadeh R,Hoffmann RG,Dasgupta M,Parton E

    更新日期:2012-05-01 00:00:00

  • Enhancing glucose sensor models: modeling the drop-outs.

    abstract:BACKGROUND:Computer simulation environments have been used in the development of many artificial pancreas systems. A glucose sensor model is an essential part of these environments, and different models have been proposed. However, not one of these models accounts for drop-outs of sensor readings, a well-known phenomen...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2014.0309

    authors: Emami A,Rabasa-Lhoret R,Haidar A

    更新日期:2015-06-01 00:00:00

  • Evaluation of hemoglobin A1c criteria to assess preoperative diabetes risk in cardiac surgery patients.

    abstract:OBJECTIVE:Hemoglobin A1c (A1C) has recently been recommended for diagnosing diabetes mellitus and diabetes risk (prediabetes). Its performance compared with fasting plasma glucose (FPG) and 2-h post-glucose load (2HPG) is not well delineated. We compared the performance of A1C with that of FPG and 2HPG in preoperative ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2011.0074

    authors: Gianchandani RY,Saberi S,Zrull CA,Patil PV,Jha L,Kling-Colson SC,Gandia KG,DuBois EC,Plunkett CD,Bodnar TW,Pop-Busui R

    更新日期:2011-12-01 00:00:00

  • High Glucose Variability in Hospitalized Patients with Type 1 Diabetes Mellitus.

    abstract:BACKGROUND:Glucose variability (GV) has been increasingly (or more extensively) studied in patients with type 1 diabetes (T1D) in the ambulatory setting; limited data exist on GV in hospitalized patients with T1D. MATERIALS AND METHODS:Retrospective single center cohort study, we analyzed in-hospital glucose measureme...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2017.0107

    authors: Dadlani V,Tamhane SU,Sun A,Sharma A,Delivanis DA,Thapa P,Carter RE,Kudva YC

    更新日期:2017-10-01 00:00:00

  • RETRACTED: No deleterious effect of lockdown due to COVID-19 pandemic on glycaemic control, measured by glucose monitoring, in adults with type 1 diabetes.

    abstract::The Editor of Diabetes Technology & Therapeutics is officially retracting the article entitled, "No Deleterious Effect of Lockdown Due to COVID-19 Pandemic on Glycaemic Control, Measured by Glucose Monitoring, in Adults with Type 1 Diabetes," by Beato-Vibora PI. Diabetes Technol Ther 2020; epub DOI: 10.1089/dia.2020.0...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,收录出版

    doi:10.1089/dia.2020.0184

    authors: Beato-Víbora PI

    更新日期:2020-05-12 00:00:00

  • Behavioral Patterns and Associations with Glucose Control During 12-Week Randomized Free-Living Clinical Trial of Day and Night Hybrid Closed-Loop Insulin Delivery in Adults with Type 1 Diabetes.

    abstract:OBJECTIVES:We evaluated patterns of meal intake, insulin bolus delivery, and fingerstick glucose measurements during hybrid closed-loop and sensor-augmented pump (SAP) therapy, including associations with glucose control. METHODS:Data were retrospectively analyzed from pump-treated adults with type 1 diabetes who unde...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2016.0307

    authors: Emami A,Willinska ME,Thabit H,Leelarathna L,Hartnell S,Dellweg S,Benesch C,Mader JK,Holzer M,Kojzar H,Pieber TR,Arnolds S,Evans ML,Hovorka R

    更新日期:2017-07-01 00:00:00

  • A recent survey confirms the efficacy and the safety of implanted insulin pumps during long-term use in poorly controlled type 1 diabetes patients.

    abstract:BACKGROUND:This article reports a prolonged trial with insulin pumps implanted in patients with type 1 diabetes showing poor glucose control and a high rate of complications. METHODS:We reviewed data from 181 patients undergoing implanted insulin pump therapy. Analysis included hemoglobin A1c (HbA1c) values, body weig...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2010.0209

    authors: Schaepelynck P,Renard E,Jeandidier N,Hanaire H,Fermon C,Rudoni S,Catargi B,Riveline JP,Guerci B,Millot L,Martin JF,Sola A,EVADIAC Group.

    更新日期:2011-06-01 00:00:00

  • Nutritional influences on inflammation and type 2 diabetes risk.

    abstract::There is a clear role for inflammation in the development of type 2 diabetes and its associated co-morbidities. Circulating inflammatory markers such as C-reactive protein, sialic acid, and interleukin- 6 are all significant independent predictors of disease. A number of nutritional components are hypothesized to modu...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2006.8.45

    authors: Browning LM,Jebb SA

    更新日期:2006-02-01 00:00:00

  • Development of a Collaborative Algorithm for the Management of Type 2 Diabetes during Ramadan: An Anchor on Empowerment.

    abstract::Empowerment plays significant roles in the complex management of type 2 diabetes. International guidelines have provided recommendations on management of Muslims who fast during Ramadan. However, there remains a lack of patient-centered epistemic tool to empower healthcare providers and patients in managing diabetes d...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2018.0159

    authors: Lum ZK,See Toh WY,Lim SM,Rusli KDB,Abdul Shakoor SAKK,Tsou KYK,Chew DEK,Dalan R,Kwek SC,Othman N,Lian JX,Lee JY

    更新日期:2018-10-01 00:00:00

  • Continuous glucose monitoring pilot in low-income type 1 diabetes patients.

    abstract:BACKGROUND:Continuous glucose monitoring (CGM) has been shown to be a valuable tool to improve glycemic control in patients with diabetes. The objective of this pilot study was to develop and implement CGM in an existing diabetes clinic for low-income patients on multiple daily injections. SUBJECTS AND METHODS:This wa...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2013.0072

    authors: Sequeira PA,Montoya L,Ruelas V,Xing D,Chen V,Beck R,Peters AL

    更新日期:2013-10-01 00:00:00

  • Reduction in hemoglobin A1C with real-time continuous glucose monitoring: results from a 12-week observational study.

    abstract:BACKGROUND:Real-time continuous glucose monitoring (CGM) was studied in 140 adults with diabetes over a 12-week period of home use. Hemoglobin A(1c)(HbA1c) was measured on day 1 (baseline) and at weeks 6 and 12. METHODS:On day 1, participants received the CGM device (STS(R) System, DexCom, Inc., San Diego, CA) and und...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1089/dia.2007.0205

    authors: Bailey TS,Zisser HC,Garg SK

    更新日期:2007-06-01 00:00:00