The effect of local subcutaneous delivery of vascular endothelial growth factor on the function of a chronically implanted amperometric glucose sensor.

Abstract:

:The foreign body capsule that forms around implanted devices such as glucose sensors is hypovascular and has limited permeability to glucose. Such a capsule may function better if well vascularized. We hypothesized that capsular vascularization achieved by local release of vascular endothelial growth factor (VEGF) would lead to enhanced function. Amperometric glucose sensor array disks, each with four indicating electrodes, were implanted into rats. Animals received local subcutaneous infusions of VEGF(165) via osmotic pumps at a location on the sensor face 2 mm from one of the electrodes ("near units"). "Intermediate" electrode units were 15 mm, and "distant" units were 22 mm, from the VEGF source. Every 2 weeks, a glucose infusion was given to assess sensor function by telemetry. Near units demonstrated a lower lag duration (delay after blood glucose) than intermediate and distant units. The mean absolute relative difference for near units was less than for distant units. The percentage of data pairs in the A region of the Clarke error grid of the near sensing units was greater than that of the distant units. Values for the functional measures for saline controls fell between near and distant VEGF values. Glucose sensor function was found to be more favorable in units immediately adjacent to the VEGF infusion port. The most likely cause for this finding is increased neovessel growth in the surrounding foreign body capsule. Slow release of angiogenic growth factors may be a potential method for chronically enhancing the function of a subcutaneously implanted biosensor.

journal_name

Diabetes Technol Ther

authors

Ward WK,Wood MD,Casey HM,Quinn MJ,Federiuk IF

doi

10.1089/152091504773731320

keywords:

subject

Has Abstract

pub_date

2004-04-01 00:00:00

pages

137-45

issue

2

eissn

1520-9156

issn

1557-8593

journal_volume

6

pub_type

杂志文章
  • The association of self-monitoring of blood glucose use with medication adherence and glycemic control in patients with type 2 diabetes initiating non-insulin treatment.

    abstract:BACKGROUND:The value of self-monitoring of blood glucose (SMBG) for persons with type 2 diabetes who do not use insulin remains controversial. This observational study compares the likelihood of medication adherence and change in glycated hemoglobin (A1C) for non-insulin-using patients using SMBG versus those not using...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2012.0047

    authors: Virdi N,Daskiran M,Nigam S,Kozma C,Raja P

    更新日期:2012-09-01 00:00:00

  • Fluorescein kinetics in interstitial fluid harvested from diabetic skin during fluorescein angiography: implications for glucose monitoring.

    abstract:BACKGROUND:Glucose monitoring based on sampling skin interstitial fluid (ISF) is being developed as an alternative to fingerstick blood glucose monitoring. Time delays between rapidly changing levels of glucose in blood and interstitial fluid have been reported in the literature to be between 5 and 20 minutes. This stu...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/152091599317530

    authors: Smith A,Yang D,Delcher H,Eppstein J,Williams D,Wilkes S

    更新日期:1999-04-01 00:00:00

  • Continuous subcutaneous insulin infusion and multiple dose of insulin regimen display similar patterns of blood glucose excursions in pediatric type 1 diabetes.

    abstract:BACKGROUND:Continuous subcutaneous insulin infusion (CSII) is believed to decrease glycemic variability and clinical hypoglycemia compared with the multiple daily insulin (MDI) regimen. To compare the indices of glycemic instability between CSII and MDI, we analyzed the continuous glucose monitoring system (CGMS) (Medt...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章

    doi:10.1089/dia.2005.7.587

    authors: Alemzadeh R,Palma-Sisto P,Parton EA,Holzum MK

    更新日期:2005-08-01 00:00:00

  • The Impact of Short-Term Professional Continuous Glucose Monitoring on Glycemic Control Via Lifestyle Improvement.

    abstract:BACKGROUND:The efficacy of short-term professional continuous glucose monitoring (CGM) for glycemic control in patients with diabetes remains unclear. METHODS:We performed a 3-month study to evaluate the benefits of CGM in 64 patients. RESULTS:The overall glycemic control of patients who underwent CGM improved signif...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0164

    authors: Shibusawa R,Yamada E,Okada S,Nakajima Y,Bastie CC,Yamada M

    更新日期:2018-09-01 00:00:00

  • Continuous glucose monitoring reveals delayed nocturnal hypoglycemia after intermittent high-intensity exercise in nontrained patients with type 1 diabetes.

    abstract:OBJECTIVE:Exercise is a cornerstone of diabetes therapy in type 1 diabetes mellitus (DMT1) patients. The type of exercise is important in determining the propensity to hypoglycemia. We assessed, by continuous glucose monitoring (CGM), the glucose profiles during and in the following 20h after a session of two different...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1089/dia.2010.0038

    authors: Maran A,Pavan P,Bonsembiante B,Brugin E,Ermolao A,Avogaro A,Zaccaria M

    更新日期:2010-10-01 00:00:00

  • Behavioral Patterns and Associations with Glucose Control During 12-Week Randomized Free-Living Clinical Trial of Day and Night Hybrid Closed-Loop Insulin Delivery in Adults with Type 1 Diabetes.

    abstract:OBJECTIVES:We evaluated patterns of meal intake, insulin bolus delivery, and fingerstick glucose measurements during hybrid closed-loop and sensor-augmented pump (SAP) therapy, including associations with glucose control. METHODS:Data were retrospectively analyzed from pump-treated adults with type 1 diabetes who unde...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2016.0307

    authors: Emami A,Willinska ME,Thabit H,Leelarathna L,Hartnell S,Dellweg S,Benesch C,Mader JK,Holzer M,Kojzar H,Pieber TR,Arnolds S,Evans ML,Hovorka R

    更新日期:2017-07-01 00:00:00

  • Measurement Performance of Two Continuous Tissue Glucose Monitoring Systems Intended for Replacement of Blood Glucose Monitoring.

    abstract:BACKGROUND:Currently, two systems for continuous tissue glucose monitoring (CGM) (Dexcom® G5 [DG5] and FreeStyle Libre [FL]) are intended to replace blood glucose monitoring (BGM) and, according to manufacturer labeling, are distributed as such in some jurisdictions, including the United States and the European Union. ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0105

    authors: Freckmann G,Link M,Pleus S,Westhoff A,Kamecke U,Haug C

    更新日期:2018-08-01 00:00:00

  • Reduction in hemoglobin A1C with real-time continuous glucose monitoring: results from a 12-week observational study.

    abstract:BACKGROUND:Real-time continuous glucose monitoring (CGM) was studied in 140 adults with diabetes over a 12-week period of home use. Hemoglobin A(1c)(HbA1c) was measured on day 1 (baseline) and at weeks 6 and 12. METHODS:On day 1, participants received the CGM device (STS(R) System, DexCom, Inc., San Diego, CA) and und...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1089/dia.2007.0205

    authors: Bailey TS,Zisser HC,Garg SK

    更新日期:2007-06-01 00:00:00

  • A Real-World Prospective Study of the Safety and Effectiveness of the Loop Open Source Automated Insulin Delivery System.

    abstract:OBJECTIVE:To evaluate the safety and effectiveness of the Loop Do-It-Yourself (DIY) automated insulin delivery system. RESEARCH DESIGN AND METHODS:A prospective real-world observational study was conducted, which included 558 adults and children (age range 1 to 71 years, mean HbA1c 6.8±1.0%) who initiated Loop either ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2020.0535

    authors: Lum J,Bailey R,Barnes-Lomen V,Naranjo D,Hood K,Lal RA,Arbiter B,Brown A,DeSalvo DJ,Pettus J,Calhoun P,Beck RW

    更新日期:2020-11-23 00:00:00

  • Feasibility Study of a Hybrid Closed-Loop System with Automated Insulin Correction Boluses.

    abstract:: Background: The Medtronic MiniMed™ 670G system adjusts basal insulin delivery in response to continuous glucose monitoring levels and is already in use in clinical practice. We tested the home-based feasibility of the new MiniMed advanced hybrid closed-loop (AHCL) system, ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2020.0448

    authors: Nimri R,Grosman B,Roy A,Nir J,Fisch Shvalb N,Kurtz N,Loewenthal N,Gillon-Keren M,Muller I,Atlas E,Phillip M

    更新日期:2020-12-08 00:00:00

  • Reference values of skin autofluorescence.

    abstract:BACKGROUND:Skin autofluorescence (AF) as measured with the AGE Reader (DiagnOptics Technologies, Groningen, The Netherlands) is a noninvasive prognostic marker in diabetes mellitus and other diseases with increased cardiovascular risk. This study provides reference values of healthy Caucasian control subjects as a func...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2009.0113

    authors: Koetsier M,Lutgers HL,de Jonge C,Links TP,Smit AJ,Graaff R

    更新日期:2010-05-01 00:00:00

  • The effect of capsule composition in the reversal of hyperglycemia in diabetic mice transplanted with microencapsulated allogeneic islets.

    abstract::The transplantation of microencapsulated islets may allow reversal of hyperglycemia in the absence of immunosuppression. Poly-L-lysine (PLL) on capsules may potentiate the fibrotic reaction against implanted capsules. The aims of this study were to investigate how the biocompatibility of such capsules affects their fu...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/152091503322250677

    authors: King A,Lau J,Nordin A,Sandler S,Andersson A

    更新日期:2003-01-01 00:00:00

  • Combining basal insulin analogs with glucagon-like peptide-1 mimetics.

    abstract::Basal insulin analogs are recognized as an effective method of achieving and maintaining glycemic control for patients with type 2 diabetes. However, the progressive nature of the disease means that some individuals may require additional ways to maintain their glycemic goals. Intensification in these circumstances ha...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2010.0250

    authors: Perfetti R

    更新日期:2011-09-01 00:00:00

  • Daily glucose profiles in Japanese people with normal glucose tolerance as assessed by continuous glucose monitoring.

    abstract:BACKGROUND:Little information is available regarding glucose fluctuations in postprandial states and during the oral glucose tolerance test (OGTT) in Japanese people with normal glucose tolerance (NGT). METHODS:Glucose profiles of 27 Japanese people were measured for 4 days by using continuous glucose monitoring. A 75...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2008.0083

    authors: Tsujino D,Nishimura R,Taki K,Miyashita Y,Morimoto A,Tajima N

    更新日期:2009-07-01 00:00:00

  • Inaccurate Glucose Sensor Values After Hydroxyurea Administration.

    abstract:: Objective: To assess the degree, duration, mean absolute relative difference (MARD), and error analysis of discrepant values per continuous glucose monitoring (CGM) systems after hydroxyurea (HU) administration. Research Design and Methods: ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2020.0490

    authors: Tellez SE,Hornung LN,Courter JD,Abu-El-Haija M,Nathan JD,Lawson SA,Elder DA

    更新日期:2020-12-30 00:00:00

  • Determining clinical and psychological benefits and barriers with continuous glucose monitoring therapy.

    abstract:BACKGROUND:Preventing the complications of diabetes requires tight control and minimizing blood glucose fluctuation. Pursuing these goals increases the risk of severe hypoglycemia. The authors hoped to identify if using continuous glucose monitoring (CGM) decreased the incidence of severe hypoglycemia, resulted in less...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2009.0121

    authors: Halford J,Harris C

    更新日期:2010-03-01 00:00:00

  • Evaluation of a new blood glucose monitoring system with auto-calibration.

    abstract:BACKGROUND:The Ascensia CONTOUR System (Bayer HealthCare LLC, Elkhart, IN) is a new blood glucose (BG) monitoring system (BGMS) that uses glucose dehydrogenase chemistry and that combines low sample volume, fast response time, an auto-control marking feature, and an auto-calibration function in a small package. METHOD...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究

    doi:10.1089/dia.2005.7.283

    authors: Kilo C,Pinson M,Joynes JO,Joseph H,Monhaut N,Parkes JL,Baum J

    更新日期:2005-04-01 00:00:00

  • Evaluation of Blood Glucose Meter Efficacy in an Antenatal Diabetes Clinic.

    abstract:BACKGROUND:The optimal treatment of diabetes in pregnancy requires accurate measurement of blood glucose levels, in order to minimize adverse outcomes for both mother and neonate. Self-monitoring of blood glucose is routinely used to measure glycemic control and to assess whether treatment targets are being met; howeve...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,收录出版

    doi:10.1089/dia.2015.0104

    authors: McGrath RT,Donnelly VC,Glastras SJ,Preda VA,Sheriff N,Ward P,Hocking SL,Fulcher GR

    更新日期:2016-02-01 00:00:00

  • Role of continuous subcutaneous insulin infusion in patients with recalcitrant diabetes in South India.

    abstract:BACKGROUND:We aimed to assess the effect of continuous subcutaneous insulin infusion (CSII) therapy in patients with "recalcitrant diabetes" whose glycemia had not been controlled adequately with multiple daily injections of insulin or insulin plus oral hypoglycemic agents. PATIENTS AND METHODS:We retrospectively anal...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2009.0066

    authors: Sudhakaran C,Anjana RM,Rao K,Unnikrishnan R 1st,Suresh T,Mohan V

    更新日期:2009-11-01 00:00:00

  • Human factors research applied: the development of a personal touch screen insulin pump and users' perceptions of actual use.

    abstract:BACKGROUND:A brief history of the field of human factors research is covered, along with how this discipline is leveraged within medical device companies, to eliminate design flaws in products, in order to make them safe and effective for human use. The way in which human factors research was used to develop the t:slim...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究

    doi:10.1089/dia.2013.0098

    authors: Schaeffer NE

    更新日期:2013-10-01 00:00:00

  • Continuous glucose monitoring pilot in low-income type 1 diabetes patients.

    abstract:BACKGROUND:Continuous glucose monitoring (CGM) has been shown to be a valuable tool to improve glycemic control in patients with diabetes. The objective of this pilot study was to develop and implement CGM in an existing diabetes clinic for low-income patients on multiple daily injections. SUBJECTS AND METHODS:This wa...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2013.0072

    authors: Sequeira PA,Montoya L,Ruelas V,Xing D,Chen V,Beck R,Peters AL

    更新日期:2013-10-01 00:00:00

  • Improved glycemic control after long-term insulin pump use in pediatric patients with type 1 diabetes.

    abstract:BACKGROUND:There are currently few data available on the long-term use of continuous subcutaneous insulin infusion (CSII) (insulin pump) therapy in children. METHODS:Charts from 291 youth with type 1 diabetes (T1D) who were treated with CSII therapy for at least 1 year were reviewed. Data analysis included hemoglobin ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2007.0214

    authors: Scrimgeour L,Cobry E,McFann K,Burdick P,Weimer C,Slover R,Chase HP

    更新日期:2007-10-01 00:00:00

  • Predicting the effectiveness of insulin pump therapy on glycemic control in clinical practice: a retrospective study of patients with type 1 diabetes from 10 outpatient diabetes clinics in Sweden over 5 years.

    abstract:BACKGROUND:Multicenter long-term studies of predictors for the effectiveness of continuous subcutaneous insulin infusion (CSII) in clinical practice are lacking. We hypothesized that there are substantially greater reductions in hemoglobin A1c (HbA1c) in patients with poor glycemic control and that other predictors may...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2014.0139

    authors: Clements M,Matuleviciene V,Attvall S,Ekelund M,Pivodic A,Dahlqvist S,Fahlén M,Haraldsson B,Lind M

    更新日期:2015-01-01 00:00:00

  • Safety and Efficacy of Initializing the Control-IQ Artificial Pancreas System Based on Total Daily Insulin in Adolescents with Type 1 Diabetes.

    abstract:: Objective: To assess the safety and efficacy of a simplified initialization for the Tandem t:slim X2 Control-IQ hybrid closed-loop system, using parameters based on total daily insulin ("MyTDI") in adolescents with type 1 diabetes under usual activity and during periods of...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2019.0471

    authors: Schoelwer MJ,Robic JL,Gautier T,Fabris C,Carr K,Clancy-Oliveri M,Brown SA,Anderson SM,DeBoer MD,Cherñavvsky DR,Breton MD

    更新日期:2020-08-01 00:00:00

  • Factors associated with persistence and resumption of insulin pen use for patients with type 2 diabetes.

    abstract:OBJECTIVE:this study assessed patient-related factors associated with persistence and resumption of using pens as insulin delivery devices. METHODS:patients (n = 549; 300 current pen users, 249 former pen users) were recruited from national panels to participate in computer-assisted telephone interviews. Measures incl...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2010.0128

    authors: Peyrot M,Rubin RR

    更新日期:2011-01-01 00:00:00

  • Patient-reported outcomes in adults with type 2 diabetes using mealtime inhaled technosphere insulin and basal insulin versus premixed insulin.

    abstract:AIMS:This study assessed patient-reported outcomes in a multicenter study of adults with type 2 diabetes taking mealtime Technosphere(®) inhaled insulin (MannKind Corp., Valencia, CA) and basal insulin (insulin glargine) or premixed aspart insulin 70/30. METHODS:Subjects were 618 non-smoking adults with starting hemog...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1089/dia.2011.0037

    authors: Peyrot M,Rubin RR

    更新日期:2011-12-01 00:00:00

  • Recovery of β-cell functions with low-dose insulin therapy: study in newly diagnosed type 2 diabetes mellitus patients.

    abstract:AIM:Insulin therapy induces remission in subjects with newly diagnosed type 2 diabetes mellitus (T2DM). This study assessed the insulin and C-peptide levels in newly diagnosed T2DM subjects during low-dose insulin therapy. SUBJECTS AND METHODS:Twenty newly diagnosed, drug-naive, T2DM patients without acute or chronic ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2010.0187

    authors: Bhattacharya S,Ammini AC,Jyotsna V,Gupta N,Dwivedi S

    更新日期:2011-04-01 00:00:00

  • Non-invasive glucose measurement technologies: an update from 1999 to the dawn of the new millennium.

    abstract::There are three main issues in non-invasive (NI) glucose measurements: namely, specificity, compartmentalization of glucose values, and calibration. There has been progress in the use of near-infrared and mid-infrared spectroscopy. Recently new glucose measurement methods have been developed, exploiting the effect of ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2004.6.660

    authors: Khalil OS

    更新日期:2004-10-01 00:00:00

  • A dynamic risk measure from continuous glucose monitoring data.

    abstract:BACKGROUND:The quantitative analysis of glucose time-series can greatly help the management of diabetes. In particular, a static nonlinear transformation, which symmetrizes the distribution of glucose levels by bringing them in the so-called risk space, was proposed previously for both self-monitoring blood glucose and...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2011.0006

    authors: Guerra S,Sparacino G,Facchinetti A,Schiavon M,Man CD,Cobelli C

    更新日期:2011-08-01 00:00:00

  • Clinical predictors of glycosylated hemoglobin response to thiazolidinedione therapy.

    abstract:BACKGROUND:The aim of this investigation was to assess clinical predictors of the glycosylated hemoglobin (HbA1C) response after the addition of a thiazolidinedione (TZD) to a biguanide, a sulfonylurea, or both in subjects with type 2 diabetes. METHODS:Chart review (n = 68 physicians) was used to identify consecutive ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2007.0248

    authors: Izumi R,Hurt J,Maki KC,Bell M,Zavras AI,McCamish M

    更新日期:2007-12-01 00:00:00