Abstract:
:New glucose sensors based on various technologies are being developed to provide information for improved therapy in diabetes. There is a need to establish rational performance standards for these sensors. Frequently sampled, direct blood glucose recordings representative of blood glucose excursions in diabetes are the "gold standard." An extensive literature search revealed a limited number of diabetic and nondiabetic blood glucose recordings suitable for this purpose. Certain blood glucose recordings reflect the diversity of glycemic dynamics and provide sufficient challenge for evaluation of sensor systems. These recordings were converted into an accessible electronic format. An example is given of the use of these benchmark data to estimate aliasing error, or the error due to insufficient sampling frequency, based on a hypothetical sensor system having some properties of conventional "fingerstick" systems. Discrete sampling systems accumulate substantial aliasing error as the sampling period increases.
journal_name
Diabetes Technol Therjournal_title
Diabetes technology & therapeuticsauthors
Bremer TM,Edelman SV,Gough DAdoi
10.1089/15209150152607196keywords:
subject
Has Abstractpub_date
2001-10-01 00:00:00pages
409-18issue
3eissn
1520-9156issn
1557-8593journal_volume
3pub_type
杂志文章abstract:BACKGROUND:The purpose of this study is to test the agreement between energy expenditure estimate of the SenseWear(®) Armband Pro3 (SWA) (BodyMedia, Pittsburgh, PA) and the Omron HJ-720 (Omron Healthcare, Kyoto, Japan) step counter with indirect calorimetry (IC) as a gold standard in older individuals with type 1 and t...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2012.0235
更新日期:2013-05-01 00:00:00
abstract:: Background: FreeStyle Libre is a factory-calibrated continuous 14-day glucose sensor. Little is known about the accuracy of FreeStyle Libre as a function of sensor age. Methods: We assessed the accuracy of FreeStyle Libre in 14...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章
doi:10.1089/dia.2019.0262
更新日期:2020-03-01 00:00:00
abstract::Chronic hyperglycemia, as assessed by hemoglobin A1c (HbA1c) levels, has been associated with the development of microvascular and macrovascular complications of diabetes. Several studies have shown that acute hyperglycemia can add to the effect of chronic hyperglycemia in inducing tissue damage. Acute hyperglycemia c...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/dia.2010.0146
更新日期:2011-03-01 00:00:00
abstract::Continuous glucose monitoring (CGM) systems have been available for more than 15 years by now. However, market uptake is relatively low in most countries; in other words, relatively few patients with diabetes use CGM systems regularly. One major reason for the reluctance of patients to use CGM systems is the costs ass...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2015.0296
更新日期:2016-02-01 00:00:00
abstract:OBJECTIVE:To evaluate the safety of in-home use of the MiniMed™ 670G system with SmartGuard™ technology in children with type 1 diabetes (T1D). METHODS:Participants (N = 105, ages 7-13 years, mean age 10.8 ± 1.8 years) were enrolled at nine centers (eight in the United States and one in Israel) and completed a 2-week ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2018.0264
更新日期:2019-01-01 00:00:00
abstract:BACKGROUND:The junction of telemedicine home monitoring with multifaceted disease management programs seems nowadays a promising direction to combine the need for an intensive approach to deal with diabetes and the pressure to contain the costs of the interventions. Several projects in the European Union and the United...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2004.6.567
更新日期:2004-10-01 00:00:00
abstract:BACKGROUND:Persistent use of real-time continuous glucose monitoring (CGM) improves diabetes control in individuals with type 1 diabetes (T1D) and type 2 diabetes (T2D). METHODS:PRECISE II was a nonrandomized, blinded, prospective, single-arm, multicenter study that evaluated the accuracy and safety of the implantable...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究
doi:10.1089/dia.2017.0142
更新日期:2018-03-01 00:00:00
abstract:BACKGROUND:This study was designed to validate the use of SoloSTAR (sanofi-aventis Deutschland GmbH, Frankfurt, Germany), a new disposable pen developed for use with insulin glargine by patients with type 1 or type 2 diabetes. METHODS:This single-center, open-label, single-arm, sequential trial enrolled subjects with ...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章
doi:10.1089/dia.2008.0079
更新日期:2008-10-01 00:00:00
abstract::The microdialysis technique allows extraction of substances (e.g., glucose) from fluids in the human body for quantitative measurements ex vivo. The microdialysis catheter can be inserted in many different tissues; for continuous glucose monitoring it is most often implanted in the subcutaneous fat tissue in the abdom...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/152091503322250578
更新日期:2003-01-01 00:00:00
abstract:BACKGROUND:Continuous glucose monitoring (CGM) has been shown to improve glycemic control and reduce hypoglycemia with consistent use. Youth, however, are unlikely to use CGM consistently. We compared psychological characteristics of youth with type 1 diabetes, their parents, and adults with type 1 diabetes randomized ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2011.0201
更新日期:2012-06-01 00:00:00
abstract::Disease registries are a searchable list of all patients with a particular chronic condition that often interface with an electronic medical record. The well-designed registry links all members of the patient's health team and provides key information for patients and physicians. The critical impact of a registry is t...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2008.0057
更新日期:2009-04-01 00:00:00
abstract:BACKGROUND:This article reports a prolonged trial with insulin pumps implanted in patients with type 1 diabetes showing poor glucose control and a high rate of complications. METHODS:We reviewed data from 181 patients undergoing implanted insulin pump therapy. Analysis included hemoglobin A1c (HbA1c) values, body weig...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2010.0209
更新日期:2011-06-01 00:00:00
abstract:BACKGROUND:Diabetes mellitus is rare in young infants and neonates. Continuous subcutaneous insulin infusion (CSII) is used most frequently for insulin treatment in this age group. However, the individual doctor's experience is scarce because of the low prevalence of diabetes in this age. For this study patients treate...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,多中心研究
doi:10.1089/dia.2015.0030
更新日期:2015-12-01 00:00:00
abstract:BACKGROUND:To protect against ischemia, pressure-induced vasodilation (PIV) causes an increase in skin blood flow. Endothelial dysfunction, which is commonly found in older patients and those with diabetes, and global temperatures can affect the resting blood flow in skin, which may reduce the blood flow during and aft...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2009.0097
更新日期:2009-12-01 00:00:00
abstract:OBJECTIVE:This study assessed the association of serum adiponectin with carotid intimal medial thickness (IMT) in Asian Indians with different grades of glucose intolerance. METHODS:Subjects with normal glucose tolerance (NGT) (n = 520), impaired glucose tolerance (IGT) (n = 115), and type 2 diabetes mellitus (T2DM) (...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2009.0100
更新日期:2010-02-01 00:00:00
abstract:BACKGROUND:Little information is available regarding glucose fluctuations in postprandial states and during the oral glucose tolerance test (OGTT) in Japanese people with normal glucose tolerance (NGT). METHODS:Glucose profiles of 27 Japanese people were measured for 4 days by using continuous glucose monitoring. A 75...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2008.0083
更新日期:2009-07-01 00:00:00
abstract:: Background: Glycemic variability (GV) is an important component of glycemic control for patients with type 1 diabetes (T1D). The inadequacy of existing measurements lies in the fact that they view the variability from different aspects, so that no consensus has been reache...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2019.0250
更新日期:2020-04-01 00:00:00
abstract::It is becoming increasingly acknowledged that people with Type 2 Diabetes represent what can be termed "an enriched population": a group that has the greatest risk of morbidity and mortality from cardiovascular diseases such as myocardial infarcts and strokes. Due to the tremendous toll, both human and financial, that...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,评审
doi:10.1089/15209150050025258
更新日期:2000-07-01 00:00:00
abstract:: Background: Current manual diabetic retinopathy (DR) screening using eye care experts cannot scale to screen the growing population of diabetes patients who are at risk for vision loss. EyeArt system is an automated, cloud-based artificial intelligence (AI) eye screening t...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2019.0164
更新日期:2019-11-01 00:00:00
abstract:: Background: The objective of this study was to assess the safety and performance of the Omnipod® personalized model predictive control (MPC) algorithm in adults, adolescents, and children aged ≥6 years with type 1 diabetes (T1D) under free-living conditions using an invest...
journal_title:Diabetes technology & therapeutics
pub_type: 临床试验,杂志文章,多中心研究
doi:10.1089/dia.2019.0286
更新日期:2020-03-01 00:00:00
abstract:BACKGROUND:Recent evidence emphasizes the importance of maintaining normoglycemia in critically ill patients to reduce morbidity and mortality. Different analytical methods of varying accuracy exist for obtaining and measuring blood glucose in critically ill patients. The purpose of this study was to determine if there...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2008.0263
更新日期:2008-06-01 00:00:00
abstract:BACKGROUND:Various insulin delivery systems have been considered for systemic absorption other than injections. Although the ocular route has been suggested, its use is limited by the amount of insulin absorbed systemically via eyes. In order to improve the absorption rate of insulin into systemic circulations, the eff...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2005.7.695
更新日期:2005-10-01 00:00:00
abstract:: Background: The use of real-time continuous glucose monitoring (rtCGM) systems has proved to positively impact the management of type 1 diabetes with the potential to lower HbA1c, reduce frequency and time spent in hypoglycemia, and lower glycemic variability. Nevertheless...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2018.0397
更新日期:2019-05-01 00:00:00
abstract:BACKGROUND:Continuous glucose monitoring (CGM) time-series are often analyzed, retrospectively, to investigate glucose variability (GV), a risk factor for the development of complications in type 1 diabetes (T1D). In the literature, several tens of different indices for GV quantification have been proposed, but many of...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,meta分析
doi:10.1089/dia.2013.0252
更新日期:2014-10-01 00:00:00
abstract:BACKGROUND:Insulin initiation and optimization is a challenge for patients with type 2 diabetes. Our objective was to determine whether safety and efficacy of AIR inhaled insulin (Eli Lilly and Co., Indianapolis, IN) (AIR is a registered trademark of Alkermes, Inc., Cambridge, MA) using a simplified regimen was noninfe...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2009.0036
更新日期:2009-09-01 00:00:00
abstract:BACKGROUND:Because strict glucose control is important for reducing the complications of diabetes, the self-monitoring of blood glucose is one of the fundamental treatment modalities. Many glucometers have been developed. In the present study, we evaluated a new glucometer: GlucoDr Plus (Allmedicus, Anyang, Gyeonggi-do...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2009.0134
更新日期:2010-04-01 00:00:00
abstract:AIMS:This study evaluated treatment satisfaction, comfort, and function using the wireless OmniPod™ Insulin Management System (Insulet Corp., Bedford, MA) compared with conventional (infusion set) insulin pumps in young adults with type 1 diabetes. RESEARCH DESIGN AND METHODS:Twenty-nine patients (age, 24.0 ± 5.1 year...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2011.0228
更新日期:2012-05-01 00:00:00
abstract:BACKGROUND:Drugs with unspecific stimulating effects on beta-cell secretion increase the homeostasis model assessment (HOMA)-B score, indicating improved beta-cell "function." We investigated whether the beta-cell protection provided by adding pioglitazone (PIO) to glimepiride (GLIM) in comparison to up-titrating the G...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章,随机对照试验
doi:10.1089/dia.2010.0019
更新日期:2010-08-01 00:00:00
abstract:: Objective: To assess the degree, duration, mean absolute relative difference (MARD), and error analysis of discrepant values per continuous glucose monitoring (CGM) systems after hydroxyurea (HU) administration. Research Design and Methods: ...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2020.0490
更新日期:2020-12-30 00:00:00
abstract::Skin integrity and diabetes device placement are ongoing concerns for people with diabetes who utilize continuous glucose monitors (CGMs) and continuous subcutaneous insulin infusion pumps. This is especially significant for individuals with skin sensitivities, pediatric patients, and those who use devices chronically...
journal_title:Diabetes technology & therapeutics
pub_type: 杂志文章
doi:10.1089/dia.2018.0080
更新日期:2018-06-01 00:00:00