Evaluation of a BICROS System with a Directional Microphone in the Receiver and Transmitter.

Abstract:

BACKGROUND:The bilateral contralateral routing of signals (BICROS) system has provided limited benefit for speech recognition in noise for patients with asymmetric sensorineural hearing loss, even when an automatic adaptive multichannel directional microphone (DM) is in the receiver (Rx) and an omnidirectional microphone (OM) is in the transmitter (Tx). A recent BICROS system was introduced that can be programmed with a DM in the Rx and an OM or a DM in the Tx. PURPOSE:To examine if significant differences in sentence recognition in noise and subjective preferences are present between an OM and an adaptive broadband DM programmed in the Tx of a BICROS system with an automatic adaptive multichannel DM programmed in the Rx. RESEARCH DESIGN:A randomized crossover single-blind design was used to assess differences between the OM and DM programmed in the Tx. STUDY SAMPLE:Eighteen adult experienced BICROS system users were recruited. DATA COLLECTION AND ANALYSIS:The BICROS system was fit using real-ear insertion gain measures. The Tx was programmed with an OM and a DM and the Rx was always programmed with an automatic adaptive multichannel DM. The order of microphone condition in the Tx was counterbalanced. Participants acclimatized to the BICROS system for 4 weeks and returned and completed the Abbreviated Profile of Hearing Aid Benefit (APHAB) for the respective microphone condition. The Tx was then programmed with the other microphone condition and participants acclimatized for another four weeks. At the final visit, the APHAB was completed for the respective microphone condition. After eight weeks of acclimatization, Hearing in Noise Test sentences were presented in the R-Space™ system with the Tx in either the OM or DM condition for three listening conditions: (1) speech from 90° to the Rx and noise from 0°, 90°, and 180° to the Tx (Sp Rx/N Tx), (2) speech from 90° to the Tx and noise from 0°, 90°, and 180° to the Rx (Sp Tx/N Rx), and (3) speech from 0° and noise from eight surrounding loudspeakers separated by 45° (diffuse). RESULTS:A two-factor repeated measures analysis of variance revealed no significant differences between the OM and DM microphone conditions for Sp Rx/N Tx listening condition. A significant mean disadvantage of 1.9 dB (p < 0.01) was revealed for the DM compared to the OM for Sp Tx/N Rx listening condition and a mean advantage of 2.6 dB (p < 0.001) for the DM compared to the OM in a diffuse listening condition. There were no significant differences in the APHAB aided problem and resulting benefit scores between the OM and DM for the following subscales: ease of communication, background noise, reverberation, and aversiveness of sounds. CONCLUSIONS:No significant differences were revealed between OM and DM for Sp Rx/N Tx. The DM performed significantly poorer than OM for the Sp Tx/N Rx listening condition. Results revealed significant benefit for the DM compared to OM for the diffuse listening condition. No significant differences were revealed between the OM and DM on the APHAB.

journal_name

J Am Acad Audiol

authors

Valente M,Oeding K

doi

10.3766/jaaa.15031

subject

Has Abstract

pub_date

2015-11-01 00:00:00

pages

856-71

issue

10

eissn

1050-0545

issn

2157-3107

journal_volume

26

pub_type

杂志文章,随机对照试验
  • Short- and long-term effects of the modified swedish version of the Active Communication Education (ACE) program for adults with hearing loss.

    abstract:BACKGROUND:In Sweden, there is a lack of evidence-based rehabilitation programs for hearing loss. The Active Communication Education program (ACE) has successfully been used in Australia and was translated and evaluated in a Swedish pilot study. The pilot study included 23 participants (age 87 yr). No statistically sig...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.25.9.7

    authors: Oberg M,Bohn T,Larsson U

    更新日期:2014-10-01 00:00:00

  • Pitch and Duration Pattern Sequence Tests in 7- to 11-Year-Old Children: Results Depend on Response Mode.

    abstract:BACKGROUND:Pitch pattern sequence (PPS) and duration pattern sequence (DPS) tests are frequently used in the assessment of auditory processing disorder. Current recommendations suggest alternate, interchangeable modes for responding to stimuli. PURPOSE:The objective of the study is to evaluate the influence of respons...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.16132

    authors: Balen SA,Moore DR,Sameshima K

    更新日期:2019-01-01 00:00:00

  • Rate, frequency, and intensity effects on early auditory evoked potentials and binaural interaction component in humans.

    abstract::The binaural interaction component (BIC) of the auditory brainstem response (ABR) and BIC of the frequency-following response (FFR) to tonal stimuli were studied in normal-hearing adults. The ABR and BIC latencies from all subjects were consistently shorter to the click-like sound than to the 2.0 kHz tone burst. Incre...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Parthasarathy TK,Moushegian G

    更新日期:1993-07-01 00:00:00

  • Exponential Modeling of Frequency-Following Responses in American Neonates and Adults.

    abstract:BACKGROUND:The scalp-recorded frequency-following response (FFR) has been widely accepted in assessing the brain's processing of speech stimuli for people who speak tonal and nontonal languages. Characteristics of scalp-recorded FFRs with increasing number of sweeps have been delineated through the use of an exponentia...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.16135

    authors: Jeng FC,Nance B,Montgomery-Reagan K,Lin CD

    更新日期:2018-02-01 00:00:00

  • Recording and evaluation of an American dialect version of the Four Alternative Auditory Feature test.

    abstract:BACKGROUND:The Four Alternative Auditory Feature test (FAAF) is a word-based closed-set speech recognition test. Because the original test materials were recorded in British English dialect, it is not appropriate for use in the United States. PURPOSE:The purpose of this study was to produce an American dialect FAAF (A...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.25.8.4

    authors: Xu J,Cox RM

    更新日期:2014-09-01 00:00:00

  • The Middle Latency Response: A Review of Findings in Various Central Nervous System Lesions.

    abstract:BACKGROUND:The middle latency response (MLR) first came to light as an auditory evoked potential in 1958. Since then, it has aroused substantial interest and investigation by clinicians and researchers alike. In recent history, its use and popularity have dwindled in tandem with various other auditory evoked potentials...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.16141

    authors: Musiek F,Nagle S

    更新日期:2018-10-01 00:00:00

  • Role of hearing AIDS in tinnitus intervention: a scoping review.

    abstract:BACKGROUND:Tinnitus can have a devastating impact on the quality of life of the sufferer. Although the mechanisms underpinning tinnitus remain uncertain, hearing loss is often associated with its onset, and hearing aids are among the most commonly used tools for its management. PURPOSE:To conduct a scoping review to e...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.24.8.11

    authors: Shekhawat GS,Searchfield GD,Stinear CM

    更新日期:2013-09-01 00:00:00

  • Pediatric Audiology in North America: Current Clinical Practice and How It Relates to the American Academy of Audiology Pediatric Amplification Guideline.

    abstract:BACKGROUND:There is broad consensus that screening and diagnosis of permanent hearing loss in children must be embedded within a comprehensive, evidence-based, family-centered intervention program. Clinical practice guidelines (CPGs) for pediatric hearing assessment and hearing aid verification aim to reduce variabilit...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.15064

    authors: Moodie S,Rall E,Eiten L,Lindley G,Gordey D,Davidson L,Bagatto M,Scollie S

    更新日期:2016-03-01 00:00:00

  • Acceptable noise level, phoneme recognition in noise, and measures of auditory efferent activity.

    abstract::Acceptable noise level (ANL) is unrelated to sentence recognition in noise but may be related to phoneme recognition in noise (PRN). Individual differences in efferent activity in medial olivocochlear bundle (MOCB) and acoustic reflex (AR) pathways may account for intersubject variability in ANL and PRN. Monotic and d...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.16.8.2

    authors: Harkrider AW,Smith SB

    更新日期:2005-09-01 00:00:00

  • Improving Hearing Performance for Cochlear Implant Recipients with Use of a Digital, Wireless, Remote-Microphone, Audio-Streaming Accessory.

    abstract:BACKGROUND:Cochlear implant (CI) recipients experience difficulty understanding speech in noise. Remote-microphone technology that improves the signal-to-noise ratio is recognized as an effective means to improve speech recognition in noise; however, there are no published studies evaluating the potential benefits of a...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.15005

    authors: Wolfe J,Morais M,Schafer E

    更新日期:2015-06-01 00:00:00

  • Central auditory processing in a patient with bilateral temporal lobe tumors: case report.

    abstract::The purpose of this article is to report the audiologic and central auditory processing abilities of a 34-year-old male with a right temporal lobe tumor and a history of bilateral tumors of the temporal lobes. The patient was evaluated presurgical re-exploration and again at 2.5 months and 4 months postoperatively. Te...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Fallis-Cunningham R,Keith RW,Warnick RE

    更新日期:1998-08-01 00:00:00

  • A Comparison of Word-Recognition Performances on the Auditec and VA Recorded Versions of Northwestern University Auditory Test No. 6 by Young Listeners with Normal Hearing and by Older Listeners with Sensorineural Hearing Loss Using a Randomized Presentat

    abstract:BACKGROUND:The Auditec of St. Louis and the Department of Veterans Affairs (VA) recorded versions of the Northwestern University Auditory Test No. 6 (NU-6) are in common usage. Data on young adults with normal hearing for pure tones (YNH) demonstrate equal recognition performances on the two versions when the VA versio...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,随机对照试验

    doi:10.3766/jaaa.17135

    authors: Wilson RH

    更新日期:2019-05-01 00:00:00

  • Development of a clinical test of musical perception: appreciation of music in cochlear implantees (AMICI).

    abstract::The purpose of this study was to develop a test to assess the ability of persons with cochlear implants (CIs) to interpret musical signals. Up to this time, the main direction in outcomes studies of cochlear implantation has been in relation to speech recognition abilities. With improvement in CI hardware and processi...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 临床试验,杂志文章

    doi:10.3766/jaaa.19.1.6

    authors: Spitzer JB,Mancuso D,Cheng MY

    更新日期:2008-01-01 00:00:00

  • Human frequency-following response correlates of the distortion product at 2F1-F2.

    abstract::We characterized the 2F1-F2 distortion product reflected in the human frequency-following response (FFR). In the first experiment, we evaluated the input-output growth functions of the distortion product at 2F1-F2 (FFR-DP) for three primary pairs. In the second experiment, we tested the effect of primary tone level va...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.15.3.2

    authors: Pandya PK,Krishnan A

    更新日期:2004-03-01 00:00:00

  • Evaluating performance with high-frequency emphasis amplification.

    abstract::Hearing aid fitting for individuals with high-frequency impairment has been difficult because of the limited gain available at those frequencies. Special high-frequency emphasis hearing aids have been developed in an attempt to alleviate this problem. The insertion-gain responses and changes in speech-recognition perf...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Lee LW,Humes LE,Wilde G

    更新日期:1993-03-01 00:00:00

  • Hearing-aid-processed tone pips: electroacoustic and ABR characteristics.

    abstract::The auditory brainstem response (ABR) recorded while wearing a hearing aid may supply supplemental information about the benefit and appropriateness of the hearing aid for certain infants. The purposes of this study were (1) to determine the effects of different output limiting circuits on the acoustics of tone-pip st...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Brown E,Klein AJ,Snydee KA

    更新日期:1999-04-01 00:00:00

  • Examining Effects of Physical Exertion on the Dynamic Visual Acuity Test in Collegiate Athletes.

    abstract:BACKGROUND:Acute symptoms of dizziness and/or imbalance commonly experienced in athletes postconcussion are speculated to arise from dysfunction at multiple levels (i.e., inner ear or central vestibular system) to appropriately integrate afferent sensory information. Disruption along any pathway of the balance system c...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.15110

    authors: Patterson JN,Murphy AM,Honaker JA

    更新日期:2017-01-01 00:00:00

  • Use of the median method to enhance detection of the mismatch negativity in the responses of individual listeners.

    abstract::The median method was evaluated as an alternative way of expressing the mismatch negativity (MMN). Traditionally, signal averaging has been used to extract these event-related potentials from unwanted background noise. However, mean values are biased by unrejected artifact that skews the relatively small distribution ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Fox LG,Dalebout SD

    更新日期:2002-02-01 00:00:00

  • Evaluation of a cognitive test battery in young and elderly normal-hearing and hearing-impaired persons.

    abstract::A cognitive test battery sensitive to processes important for speech understanding was developed and investigated. Test stimuli are presented as text or in an auditory or audiovisual modality. The tests investigate phonologic processing and verbal information processing. Four subject groups, young/elderly with normal-...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Hällgren M,Larsby B,Lyxell B,Arlinger S

    更新日期:2001-07-01 00:00:00

  • Investigating speechreading and deafness.

    abstract:BACKGROUND:The visual speech signal can provide sufficient information to support successful communication. However, individual differences in the ability to appreciate that information are large, and relatively little is known about their sources. PURPOSE:Here a body of research is reviewed regarding the development ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,评审

    doi:10.3766/jaaa.21.3.4

    authors: Auer ET

    更新日期:2010-03-01 00:00:00

  • The Chinese Hearing Questionnaire for School Children.

    abstract::Hearing loss is the most common of all disabilities in China, with three million of the 1.4 billion population affected. Recently, the release of an official neonatal hearing screening consensus has drawn attention to the importance of continued surveillance throughout childhood and the need for a system that is suite...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.16.9.6

    authors: Bu X,Li X,Driscoll C

    更新日期:2005-10-01 00:00:00

  • Do Modern Hearing Aids Meet ANSI Standards?

    abstract:BACKGROUND:The American National Standards Institute (ANSI) provides standards used to govern standardization of all hearing aids. If hearing aids do not meet specifications, there are potential negative implications for hearing aid users, professionals, and the industry. Recent literature has not investigated the prop...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.15027

    authors: Holder JT,Picou EM,Gruenwald JM,Ricketts TA

    更新日期:2016-09-01 00:00:00

  • The effect of middle age on the late positive component of the auditory event-related potential.

    abstract:BACKGROUND:We recently described a research study in which age-related changes in interaural asymmetry were elicited using the N400 of the auditory event-related potentials (AERP) (Davis et al, 2013). The N400 was the primary focus due to its sensitivity to various aspects of semantic processing (Kutas and Hillyard, 19...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.25.2.8

    authors: Davis TM,Jerger J

    更新日期:2014-02-01 00:00:00

  • The Effect of Presentation Mode and Production Type on Word Memory for Hearing Impaired Signers.

    abstract:BACKGROUND:Production effect (PE) is a memory phenomenon referring to better memory for produced (vocalized) than for non-produced (silently read) items. Reading aloud was found to improve verbal memory for normal-hearing individuals, as well as for cochlear implant users, studying visually and aurally presented materi...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.17030

    authors: Swead RT,Mama Y,Icht M

    更新日期:2018-11-01 00:00:00

  • Progression of hearing loss following the completion of chemotherapy and radiation therapy: case report.

    abstract::There have been scattered accounts reported in the oncology literature of progressive hearing loss following the conclusion of chemotherapy. In this case study, we report the audiologic findings of such a case. These data underscore the need for post-therapy monitoring in cases where threshold shifts are discovered du...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Sweetow RW,Will TI

    更新日期:1993-11-01 00:00:00

  • Spectrotemporal modulation sensitivity as a predictor of speech intelligibility for hearing-impaired listeners.

    abstract:BACKGROUND:A model that can accurately predict speech intelligibility for a given hearing-impaired (HI) listener would be an important tool for hearing-aid fitting or hearing-aid algorithm development. Existing speech-intelligibility models do not incorporate variability in suprathreshold deficits that are not well pre...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.24.4.5

    authors: Bernstein JG,Mehraei G,Shamma S,Gallun FJ,Theodoroff SM,Leek MR

    更新日期:2013-04-01 00:00:00

  • Dehydration testing and the diagnosis of Menière's disease: case report.

    abstract::A 34-year-old female presented to our clinic with complaints of hearing loss, tinnitus, and severe rotational vertigo. A test battery including complete audiometric testing, auditory brainstem response (ABR) audiometry, electronystagmography (ENG), electrocochleography (ECoG), and dehydration testing was performed. Mo...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Yellin MW,Waller M,Roland PS

    更新日期:1993-11-01 00:00:00

  • Evaluation of a "direct-comparison" approach to automatic switching in omnidirectional/directional hearing aids.

    abstract:BACKGROUND:Hearing aids today often provide both directional (DIR) and omnidirectional (OMNI) processing options with the currently active mode selected automatically by the device. The most common approach to automatic switching involves "acoustic scene analysis" where estimates of various acoustic properties of the l...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.19.9.6

    authors: Summers V,Grant KW,Walden BE,Cord MT,Surr RK,Elhilali M

    更新日期:2008-10-01 00:00:00

  • Evidence against the influence of aging on distortion-product otoacoustic emissions.

    abstract::Previous research has reported reduced otoacoustic emission amplitude as a function of age. In each study, however, interpretation of findings was confounded by age-related hearing loss. The present study was designed to re-evaluate the contribution of age and peripheral hearing loss on the prevalence and amplitude of...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Strouse AL,Ochs MT,Hall JW 3rd

    更新日期:1996-10-01 00:00:00

  • Hearing impaired children's preference for, and performance with, four combinations of directional microphone and digital noise reduction technology.

    abstract:BACKGROUND:Before advanced noise-management features can be recommended for use in children with hearing loss, evidence regarding their ability to use these features to optimize speech perception is necessary. PURPOSE:The purpose of this study was to examine the relation between children's preference for, and performa...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.24.9.7

    authors: Pittman AL,Hiipakka MM

    更新日期:2013-10-01 00:00:00