Abstract:
BACKGROUND:The American National Standards Institute (ANSI) provides standards used to govern standardization of all hearing aids. If hearing aids do not meet specifications, there are potential negative implications for hearing aid users, professionals, and the industry. Recent literature has not investigated the proportion of new hearing aids in compliance with the ANSI specifications for quality control standards when they arrive in the clinic before dispensing. PURPOSE:The aims of this study were to determine the percentage of new hearing aids compliant with the relevant ANSI standard and to report trends in electroacoustic analysis data. RESEARCH DESIGN:New hearing aids were evaluated for quality control via the ANSI S3.22-2009 standard. In addition, quality control of directional processing was also assessed. STUDY SAMPLE:Seventy-three behind-the-ear hearing aids from four major manufacturers, that were purchased for clinical patients were evaluated before dispensing. DATA COLLECTION AND ANALYSIS:Audioscan Verifit (version 3.1) hearing instrument fitting system was used to complete electroacoustic analysis and directional processing evaluation of the hearing aids. Frye's Fonix 8000 test box system (Fonix 8000) was also used to cross-check equivalent input noise (EIN) measurements. These measurements were then analyzed for trends across brands and specifications. RESULTS:All of the hearing aids evaluated were found to be out of specification for at least one measure. EIN and attack and release times were the measures most frequently out of specification. EIN was found to be affected by test box isolation for two of the four brands tested. Systematic discrepancies accounted for ∼93% of the noncompliance issues, while unsystematic quality control issues accounted for the remaining 7%. CONCLUSIONS:The high number of systematic discrepancies between the data collected and the specifications published by the manufacturers suggests there are clear issues related to the specific protocols used for quality control testing. These issues present a significant barrier for hearing aid dispensers when attempting to accurately determine if a hearing aid is functioning appropriately. The significant number of unsystematic discrepancies supports the continued importance of quality control measures of new and repaired hearing aids to ensure that the device is functioning properly before it is dispensed and to avoid future negative implications of fitting a faulty device.
journal_name
J Am Acad Audioljournal_title
Journal of the American Academy of Audiologyauthors
Holder JT,Picou EM,Gruenwald JM,Ricketts TAdoi
10.3766/jaaa.15027subject
Has Abstractpub_date
2016-09-01 00:00:00pages
619-27issue
8eissn
1050-0545issn
2157-3107journal_volume
27pub_type
杂志文章abstract:BACKGROUND:The Four Alternative Auditory Feature test (FAAF) is a word-based closed-set speech recognition test. Because the original test materials were recorded in British English dialect, it is not appropriate for use in the United States. PURPOSE:The purpose of this study was to produce an American dialect FAAF (A...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.25.8.4
更新日期:2014-09-01 00:00:00
abstract::Probe-microphone measurements are typically made with behind-the-ear (BTE) and in-the-ear (ITE) hearing aids with the loudspeaker located at 0-degrees or 45-degrees azimuth at head level and the reference microphone positioned on the head near the hearing aid microphone. With body-worn instruments, these conditions ma...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1994-03-01 00:00:00
abstract:PURPOSE:There will likely be several different tinnitus treatments necessary, and it is important to understand patient preferences and factors that might contribute to treatment acceptability. This study explores the acceptability of a wide range of different tinnitus treatments, from noninvasive wearable devices to s...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.23.2.6
更新日期:2012-02-01 00:00:00
abstract:BACKGROUND:Despite improvements in cochlear implants (CIs), CI recipients continue to experience significant communicative difficulty in background noise. Many potential solutions have been proposed to help increase signal-to-noise ratio in noisy environments, including signal processing and external accessories. To da...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.26.1.6
更新日期:2015-01-01 00:00:00
abstract::The efficacy of a digital hearing aid with a directional microphone was examined in a school-aged population. Twenty children (9 with a mild-to-moderately-severe hearing loss and 11 with a moderate-to-severe hearing loss) between 7 1/2 and 13 2/3 years of age wore the study hearing aids binaurally for 30 days prior to...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1999-11-01 00:00:00
abstract::A 52-year-old male was evaluated by the authors after initially reporting fullness in his left ear while traveling on an airplane. A unique feature of the patient's complaint was the development of severe bilateral hyperacusis (loudness discomfort levels of between 20-34 dB HL) in spite of the fact that the hearing lo...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:2000-06-01 00:00:00
abstract::In a clinical experiment, it was found that there is a high correlation between the compliance measured by tympanometry and the minimum size of the earmold vent, which just solves the client's occlusion problem related to his/her own voice when using a hearing aid. For ears with sensorineural hearing losses, complianc...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:2002-01-01 00:00:00
abstract::A Macintosh computer-based audiometer (Virtual 320) was evaluated for reliability and validity of high-frequency (8-20 kHz) thresholds by comparison with a well documented laboratory high-frequency evaluation system (PARVA-HF). High-frequency earphones originally provided with the V320 for high-frequency testing requi...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1990-07-01 00:00:00
abstract::Although it has been reported that smoking has deleterious effects on the middle ears of smokers, including their eustachian tubes, investigators have failed to find differences in the tympanometric characteristics of smokers and nonsmokers. In the present study, however, we found that the Valsalva-induced tympanometr...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1997-08-01 00:00:00
abstract::The Hearing-in-Noise Test (HINT) is able to measure the benefit to speech intelligibility in noise conferred when the noise masker is displaced 90 degrees in eccentricity from a speech source located at zero degrees azimuth. Both psychoacoustic and neurophysiological data suggest that the perceptual benefit of the 90-...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.14.9.7
更新日期:2003-11-01 00:00:00
abstract::The case reported here, a 26-year-old woman, has a bilaterally symmetric, severe-to-profound, sensorineural hearing loss, acquired early in life. Phoneme recognition scores were essentially symmetric at the onset of the investigation. She was basically monaurally aided from age 4 to age 24, at which time a loss of fun...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1993-09-01 00:00:00
abstract:BACKGROUND:A deficit in the processing of auditory information may underlie problems in understanding speech in the presence of background noise, degraded speech, and in following spoken instructions. Children with auditory processing disorders are challenged in the classroom because of ambient noise levels and maybe a...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.26.4.4
更新日期:2015-04-01 00:00:00
abstract::The Words-in-Noise (WIN) test uses monosyllabic words in seven signal-to-noise ratios of multitalker babble (MTB) to evaluate the ability of individuals to understand speech in background noise. The purpose of this study was to evaluate the criterion validity of the WIN by comparing recognition performances under MTB ...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.18.6.7
更新日期:2007-06-01 00:00:00
abstract:BACKGROUND:Significant growth in the U.S. population over the next 30 yr will likely increase the demand for hearing-care services. In addition, increased accessibility to hearing-care services may be realized due to increased insurance coverage associated with health-care reform efforts. In order to meet this demand, ...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章,评审
doi:10.3766/jaaa.24.5.7
更新日期:2013-05-01 00:00:00
abstract:BACKGROUND:Prior to undergoing vestibular function testing, it is not uncommon for clinicians to request that patients abstain from caffeine 24 hr prior to the administration of the tests. However, there is little evidence that caffeine affects vestibular function. PURPOSE:To evaluate whether the results from two test...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.25.3.5
更新日期:2014-03-01 00:00:00
abstract:BACKGROUND:Auditory fitness for duty (AFFD) testing is an important element in an assessment of workers' ability to perform job tasks safely and effectively. Functional hearing is particularly critical to job performance in law enforcement. Most often, assessment is based on pure-tone detection thresholds; however, its...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.22.6.2
更新日期:2011-06-01 00:00:00
abstract:BACKGROUND:Although newborn hearing screening programs have been introduced in most states in Australia, the prevalence of conductive hearing loss and middle ear pathology in the infants referred through these programs is not known. PURPOSE:This study was designed to (1) evaluate the prevalence of conductive hearing l...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.23.9.2
更新日期:2012-10-01 00:00:00
abstract::Compact disc versions of the frequency (pitch) and duration pattern tests are reported. Results are similar to previous reports on these tests using taped materials. Mean performance of normal-hearing young adults for both pattern perception tests was approximately 90 percent. There was no effect of the two presentati...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1994-07-01 00:00:00
abstract::This study assessed speech perception benefits for three congenitally deaf adolescents who used an electrotactile speech processor (Tickle Talker(TM)) and subsequently went on to use a Nucleus Minisystem 22 cochlear implant. Both devices provided significant and comparable benefits for all children in the device plus ...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1996-04-01 00:00:00
abstract:BACKGROUND:Tele-audiology provides a means to offer audiologic rehabilitation (AR) in a cost-, resource-, and time-effective manner. If designed appropriately, it also has the capability of personalizing rehabilitation to the user in terms of content, depth of detail, etc., thus permitting selection of the best content...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章,评审
doi:10.3766/jaaa.14062
更新日期:2015-10-01 00:00:00
abstract::The Three-Clinic Hearing Aid Selection Profile (HASP) was developed to assess a patient's beliefs about a number of basic considerations felt to be critical to the hearing aid selection (HAS) process. These characteristics are felt to be key to the acceptance of amplification and include motivation, expectations, cost...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:2001-03-01 00:00:00
abstract::This paper discusses trends and issues in selecting amplification for new, mainly nonlinear, types of hearing aids. Some-concerns are that nonvalidated prescription formulae may proliferate; that, through concentration on loudness normalization, alternative rationales are not being evaluated; and that most new fitting...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章,评审
doi:
更新日期:1996-12-01 00:00:00
abstract:BACKGROUND:Many studies have reported the speech recognition benefits of a personal remote microphone system when used by adult listeners with hearing loss. The advance of wireless technology has allowed for many wireless audio transmission protocols. Some of these protocols interface with commercially available hearin...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章,随机对照试验
doi:10.3766/jaaa.15008
更新日期:2015-09-01 00:00:00
abstract::In recent years, we have observed causes of congenital or early onset hearing disorders that had not been recognized or known to exist before. These include drugs passed to an as-yet unborn child. Principal among them is alcohol, but others, such as cocaine, are now also occupying our attention. This article reviews t...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章,评审
doi:
更新日期:1995-09-01 00:00:00
abstract::The literature suggests that directional microphone hearing aids (DMHAs) are a viable means for improving the signal-to-noise ratio (SNR) for hearing-impaired listeners. The amount of directional advantage they provide, however, remains relatively unclear because of variability observed among individual studies. The p...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章,meta分析
doi:
更新日期:2001-04-01 00:00:00
abstract::Auditory brainstem responses were measured in response to 1000-Hz tone bursts from 115 patients with sensorineural hearing loss, presumably of cochlear origin. Mean wave V latencies and variability were comparable to those observed in normal hearing subjects for similar stimuli. The range of interaural differences in ...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1992-05-01 00:00:00
abstract:BACKGROUND:Degraded hearing in older adults has been associated with reduced postural control and higher risk of falls. Both hearing loss (HL) and falls have dramatic effects on older persons' quality of life (QoL). A large body of research explored the comorbidity between the two domains. PURPOSE:The aim of the curre...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章,评审
doi:10.3766/jaaa.16044
更新日期:2017-06-01 00:00:00
abstract:BACKGROUND:The acoustic stapedial reflex (ASR) test provides useful information about the function of the auditory system. While it is frequently used with adults and children in a clinical setting, its use with young infants is limited. Presently, there are few data for neonates and inadequate research into the test-r...
journal_title:Journal of the American Academy of Audiology
pub_type: 临床试验,杂志文章
doi:10.3766/jaaa.23.1.5
更新日期:2012-01-01 00:00:00
abstract::This study examined the influence of technology, demographic factors, and prefitting expectations, attitudes, and adjustment to hearing loss on hearing aid outcome. Clients obtaining new hearing aids completed questionnaires measuring personal adjustment to hearing loss, expectations of and attitudes toward hearing ai...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:2001-02-01 00:00:00
abstract:PURPOSE:Vestibular rehabilitation exercises have been proven to reduce symptoms and diminish the risk of falls in those with dizziness and balance impairments. The first purpose of this study is to investigate a new method of measuring head movements during habituation vestibular rehabilitation exercises. The second is...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.16026
更新日期:2018-01-01 00:00:00