Recording and evaluation of an American dialect version of the Four Alternative Auditory Feature test.

Abstract:

BACKGROUND:The Four Alternative Auditory Feature test (FAAF) is a word-based closed-set speech recognition test. Because the original test materials were recorded in British English dialect, it is not appropriate for use in the United States. PURPOSE:The purpose of this study was to produce an American dialect FAAF (AFAAF). RESEARCH DESIGN:The AFAAF materials spoken by a native American-English speaking male were recorded and digitally edited. In the validation study, the AFAAF was administered monaurally at five signal-to-noise ratios (SNRs) in both ears for each listener. STUDY SAMPLE:A total of 20 young adults with normal hearing participated in the validation study. DATA COLLECTION AND ANALYSIS:For each participant, speech recognition scores were collected in one session. The speech level was fixed at 70 dB SPL and the steady-state talker-matched noise level was varied, resulting in five SNRs from -15 to -5 dB. One full list (80 words) was used for each SNR. For each participant, a performance-intensity (PI) function was fit to the discrete mean percent correct scores for the five SNRs according to a best-fit, three-parameter sigmoid function. In addition, scores for the left and right ears were compared to examine test-retest reliability. RESULTS:RESULTS show that the slope of the PI function is 6% per dB, the mean test-retest difference scores for the five SNRs are within 3 rationalized arcsine units (rau), and the 95% critical difference for the 80-word scores is 12 rau. Compared with the FAAF, the slope of the PI function for the AFAAF is slightly less steep. Test-retest reliability of the AFAAF is at least equal to that of the FAAF. CONCLUSIONS:It is concluded that the AFAAF is similar but not identical to the FAAF. The AFAAF is now available for measuring speech recognition performance in listeners who use American English as a native language.

journal_name

J Am Acad Audiol

authors

Xu J,Cox RM

doi

10.3766/jaaa.25.8.4

subject

Has Abstract

pub_date

2014-09-01 00:00:00

pages

737-45

issue

8

eissn

1050-0545

issn

2157-3107

journal_volume

25

pub_type

杂志文章
  • A review of common dermatologic disorders of the external ear.

    abstract::Skin disorders of the external ear are common. Although audiologists will not necessarily treat these conditions, it is important for them to be aware of these disorders and refer patients to a specialist in some instances. This report summarizes eight of the most commonly encountered skin conditions with an emphasis ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,评审

    doi:10.3766/jaaa.19.3.6

    authors: Garvey C,Garvey K,Hendi A

    更新日期:2008-03-01 00:00:00

  • Evidence against the influence of aging on distortion-product otoacoustic emissions.

    abstract::Previous research has reported reduced otoacoustic emission amplitude as a function of age. In each study, however, interpretation of findings was confounded by age-related hearing loss. The present study was designed to re-evaluate the contribution of age and peripheral hearing loss on the prevalence and amplitude of...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Strouse AL,Ochs MT,Hall JW 3rd

    更新日期:1996-10-01 00:00:00

  • Routine use of the crystal device integrity testing system in pediatric patients.

    abstract::Crystal Device Integrity Testing System (CITS), the first commercially available testing system of its type, allows rapid assessment of cochlear implant function by measuring averaged electrode voltages-the scalp-recorded fields generated by electrode currents. We describe our experience performing routine integrity t...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.17.10.4

    authors: Monin DL,Kazahaya K,Franck KH

    更新日期:2006-11-01 00:00:00

  • The Benefit of Remote Microphones Using Four Wireless Protocols.

    abstract:BACKGROUND:Many studies have reported the speech recognition benefits of a personal remote microphone system when used by adult listeners with hearing loss. The advance of wireless technology has allowed for many wireless audio transmission protocols. Some of these protocols interface with commercially available hearin...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,随机对照试验

    doi:10.3766/jaaa.15008

    authors: Rodemerk KS,Galster JA

    更新日期:2015-09-01 00:00:00

  • Effects of ear-canal static pressure on pure-tone thresholds and wideband acoustic immittance.

    abstract:BACKGROUND:Wideband acoustic immittance (WAI) measures provide information about middle-ear function across the traditional audiometric frequency range from 0.25 to 8.0 kHz. Recent studies have found that WAI is effective in predicting the presence of conductive hearing loss (CHL). It is not known whether WAI can accur...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.25.5.5

    authors: Feeney MP,Sanford CA,Putterman DB

    更新日期:2014-05-01 00:00:00

  • Hearing and balance screening and referrals for Medicare patients: a national survey of primary care physicians.

    abstract::Hearing and balance problems are prevalent among the elderly. Primary care physicians (PCPs) are important pivotal points of entry for ensuring that patients receive needed audiology services. New Medicare beneficiaries are entitled to one-time preventative examinations including hearing/balance screenings. A 35-item ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.19.2.7

    authors: Johnson CE,Danhauer JL,Koch LL,Celani KE,Lopez IP,Williams VA

    更新日期:2008-02-01 00:00:00

  • Adults with auditory neuropathy: comparison of auditory steady-state response and pure-tone audiometry.

    abstract:BACKGROUND:The relation between the auditory steady-state response (ASSR) and behavioral audiometric thresholds requires further clarification in the case of adults with auditory neuropathy/auditory dys-synchrony (AN/AD). PURPOSE:The aim of this study was to compare pure-tone audiometric threshold (PTAT) and ASSR in a...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.20.10.4

    authors: Jafari Z,Malayeri S,Ashayeri H,Farahani MA

    更新日期:2009-11-01 00:00:00

  • The Words-in-Noise (WIN) test with multitalker babble and speech-spectrum noise maskers.

    abstract::The Words-in-Noise (WIN) test uses monosyllabic words in seven signal-to-noise ratios of multitalker babble (MTB) to evaluate the ability of individuals to understand speech in background noise. The purpose of this study was to evaluate the criterion validity of the WIN by comparing recognition performances under MTB ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.18.6.7

    authors: Wilson RH,Carnell CS,Cleghorn AL

    更新日期:2007-06-01 00:00:00

  • Common Sound Scenarios: A Context-Driven Categorization of Everyday Sound Environments for Application in Hearing-Device Research.

    abstract:BACKGROUND:Evaluation of hearing-device signal-processing features is performed for research and development purposes, but also in clinical settings. Most people agree that the benefit experienced in a hearing-device user's daily life is most important, but laboratory tests are popular since they can be performed unifo...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.15105

    authors: Wolters F,Smeds K,Schmidt E,Christensen EK,Norup C

    更新日期:2016-07-01 00:00:00

  • Reliability and validity of high-frequency (8-20 kHz) thresholds obtained on a computer-based audiometer as compared to a documented laboratory system.

    abstract::A Macintosh computer-based audiometer (Virtual 320) was evaluated for reliability and validity of high-frequency (8-20 kHz) thresholds by comparison with a well documented laboratory high-frequency evaluation system (PARVA-HF). High-frequency earphones originally provided with the V320 for high-frequency testing requi...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Fausti SA,Frey RH,Henry JA,Knutsen JL,Olson DJ

    更新日期:1990-07-01 00:00:00

  • Big Stimulus, Little Ears: Safety in Administering Vestibular-Evoked Myogenic Potentials in Children.

    abstract:BACKGROUND:Cervical and ocular vestibular-evoked myogenic potentials (VEMPs) have become common clinical vestibular assessments. However, VEMP testing requires high intensity stimuli, raising concerns regarding safety with children, where sound pressure levels may be higher due to their smaller ear canal volumes. PURP...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.15097

    authors: Thomas MLA,Fitzpatrick D,McCreery R,Janky KL

    更新日期:2017-05-01 00:00:00

  • Evaluation of a cognitive test battery in young and elderly normal-hearing and hearing-impaired persons.

    abstract::A cognitive test battery sensitive to processes important for speech understanding was developed and investigated. Test stimuli are presented as text or in an auditory or audiovisual modality. The tests investigate phonologic processing and verbal information processing. Four subject groups, young/elderly with normal-...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Hällgren M,Larsby B,Lyxell B,Arlinger S

    更新日期:2001-07-01 00:00:00

  • Video otoscopy in audiologic practice.

    abstract::Recent advances in endoscopic optics and miniature video camera technology have made video otoscopy (VO) accessible to audiologists in a practical way. Seven categories of VO applications are presented with clinical examples: (1) general examination of the earcanal and tympanic membrane, (2) physician communication/te...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Sullivan RF

    更新日期:1997-12-01 00:00:00

  • A comparison of gain for adults from generic hearing aid prescriptive methods: impacts on predicted loudness, frequency bandwidth, and speech intelligibility.

    abstract:BACKGROUND:Prescriptive methods have been at the core of modern hearing aid fittings for the past several decades. Every decade or so, there have been revisions to existing methods and/or the emergence of new methods that become widely used. In 2001 Byrne et al provided a comparison of insertion gain for generic prescr...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.22.7.5

    authors: Johnson EE,Dillon H

    更新日期:2011-07-01 00:00:00

  • Hearing aid selection for the 1990s: where to?

    abstract::This paper discusses trends and issues in selecting amplification for new, mainly nonlinear, types of hearing aids. Some-concerns are that nonvalidated prescription formulae may proliferate; that, through concentration on loudness normalization, alternative rationales are not being evaluated; and that most new fitting...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,评审

    doi:

    authors: Byrne D

    更新日期:1996-12-01 00:00:00

  • Prediction and statistical evaluation of speech recognition test scores.

    abstract::A speech test evaluation and presentation system is described. The test presentation subsystem has the flexibility and speed of live-voice testing while using recorded test materials. The speech test evaluation subsystem compares an individual subject's test performance on a monosyllabic word test with that of an aver...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Studebaker GA,Gray GA,Branch WE

    更新日期:1999-07-01 00:00:00

  • FM amplification for enhancement of conversational discourse skills: case study.

    abstract::The purpose of this single-subject pilot study was to examine the efficacy of FM amplification for enhancing the discourse skills of a 4-year-old girl with a history of speech-language impairments, otitis media with effusion (OME), and motoric delays. Over a period of several weeks, language treatment sessions were co...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Clarke-Klein SM,Roush J,Roberts JE,Davis K,Medley L

    更新日期:1995-05-01 00:00:00

  • Cognitive factors in auditory performance: context, speed of processing, and constraints of memory.

    abstract::This paper describes several techniques used to explore the role of cognitive factors in auditory performance in elderly adults. Two factors, cognitive slowing and age-related memory constraints, receive special attention. Assessing listeners' ability to report the content of time-compressed speech shows elderly adult...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Wingfield A

    更新日期:1996-06-01 00:00:00

  • Acceptable noise level, phoneme recognition in noise, and measures of auditory efferent activity.

    abstract::Acceptable noise level (ANL) is unrelated to sentence recognition in noise but may be related to phoneme recognition in noise (PRN). Individual differences in efferent activity in medial olivocochlear bundle (MOCB) and acoustic reflex (AR) pathways may account for intersubject variability in ANL and PRN. Monotic and d...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.16.8.2

    authors: Harkrider AW,Smith SB

    更新日期:2005-09-01 00:00:00

  • Optimizing the benefit of sound processors coupled to personal FM systems.

    abstract:BACKGROUND:Use of personal frequency modulated (FM) systems significantly improves speech recognition in noise for users of cochlear implants (CI). There are, however, a number of adjustable parameters of the cochlear implant and FM receiver that may affect performance and benefit, and there is limited evidence to guid...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 临床试验,杂志文章

    doi:10.3766/jaaa.19.8.2

    authors: Wolfe J,Schafer EC

    更新日期:2008-09-01 00:00:00

  • Probe-microphone measurements with body-worn instruments: loudspeaker and reference microphone effects.

    abstract::Probe-microphone measurements are typically made with behind-the-ear (BTE) and in-the-ear (ITE) hearing aids with the loudspeaker located at 0-degrees or 45-degrees azimuth at head level and the reference microphone positioned on the head near the hearing aid microphone. With body-worn instruments, these conditions ma...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Nelson JA,Hawkins DB

    更新日期:1994-03-01 00:00:00

  • Use of a digital hearing aid with directional microphones in school-aged children.

    abstract::The efficacy of a digital hearing aid with a directional microphone was examined in a school-aged population. Twenty children (9 with a mild-to-moderately-severe hearing loss and 11 with a moderate-to-severe hearing loss) between 7 1/2 and 13 2/3 years of age wore the study hearing aids binaurally for 30 days prior to...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Kuk FK,Kollofski C,Brown S,Melum A,Rosenthal A

    更新日期:1999-11-01 00:00:00

  • Acoustic and hearing aid circuit variables affecting the tolerability of aided impulsive-type sounds.

    abstract::The tolerability of aided impulsive-type stimuli was investigated in a group of 13 hearing-impaired listeners. Two linear circuits (one with a class A and one with a class D output stage) and one adaptive frequency response (AFR) circuit (with a class D output stage) were investigated. In a three-way paired-comparison...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Fortune TW,Preves DA

    更新日期:1994-09-01 00:00:00

  • The masking-level difference in children.

    abstract::The masking-level difference (MLD) was investigated in children aged 3.9 to 9.5 years and in an adult control group in order to examine the development of the MLD with age. A three-alternative forced-choice adaptive tracking procedure was used for all listeners. MLDs were determined for a 500-Hz pure-tone signal prese...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Hall JW 3rd,Grose JH

    更新日期:1990-04-01 00:00:00

  • Potential Benefits of an Integrated Electric-Acoustic Sound Processor with Children: A Preliminary Report.

    abstract:BACKGROUND:A number of published studies have demonstrated the benefits of electric-acoustic stimulation (EAS) over conventional electric stimulation for adults with functional low-frequency acoustic hearing and severe-to-profound high-frequency hearing loss. These benefits potentially include better speech recognition...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.15133

    authors: Wolfe J,Neumann S,Schafer E,Marsh M,Wood M,Baker RS

    更新日期:2017-02-01 00:00:00

  • Personal amplification for school-age children with auditory processing disorders.

    abstract:BACKGROUND:Children with auditory processing disorders (APD) are described to have a signal-to-noise ratio (SNR) difficulty. Frequency-modulated (FM) systems have been reported to improve this situation. Yet the use of personal amplification that may be more portable has not been attempted. PURPOSE:To determine whethe...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.19.6.3

    authors: Kuk F,Jackson A,Keenan D,Lau CC

    更新日期:2008-06-01 00:00:00

  • Test-retest reliability of probe-microphone verification in children fitted with open and closed hearing aid tips.

    abstract:PURPOSE:To investigate the test-retest reliability of real-ear aided response (REAR) measures in open and closed hearing aid fittings in children using appropriate probe-microphone calibration techniques (stored equalization for open fittings and concurrent equalization for closed fittings). RESEARCH DESIGN:Probe-micr...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.24.7.11

    authors: Kim H,Ricketts TA

    更新日期:2013-07-01 00:00:00

  • Speech Understanding and Sound Source Localization by Cochlear Implant Listeners Using a Pinna-Effect Imitating Microphone and an Adaptive Beamformer.

    abstract:BACKGROUND:Sentence understanding scores for patients with cochlear implants (CIs) when tested in quiet are relatively high. However, sentence understanding scores for patients with CIs plummet with the addition of noise. PURPOSE:To assess, for patients with CIs (MED-EL), (1) the value to speech understanding of two n...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.16126

    authors: Dorman MF,Natale S,Loiselle L

    更新日期:2018-03-01 00:00:00

  • Intertester reliability of the acceptable noise level.

    abstract:BACKGROUND:The acceptable noise level (ANL) serves to accurately predict the listener's likelihood of success with amplification. It has been proposed as a pre-hearing aid fitting protocol for hearing aid selection and counseling purposes. The ANL is a subjective measure of the listener's ability to accept background n...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 临床试验,杂志文章

    doi:10.3766/jaaa.23.7.5

    authors: Gordon-Hickey S,Adams E,Moore R,Gaal A,Berry K,Brock S

    更新日期:2012-07-01 00:00:00

  • Measuring parent satisfaction with a neonatal hearing screening program.

    abstract::The primary aim of the present study was to investigate parent satisfaction with a neonatal hearing screening program through use of a valid and reliable questionnaire developed for this purpose (Parent Satisfaction Questionnaire with Neonatal Hearing Screening Program; PSQ-NHSP). Eighty parents whose children had rec...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.17.4.4

    authors: Mazlan R,Hickson L,Driscoll C

    更新日期:2006-04-01 00:00:00