Abstract:
:A 34-year-old female presented to our clinic with complaints of hearing loss, tinnitus, and severe rotational vertigo. A test battery including complete audiometric testing, auditory brainstem response (ABR) audiometry, electronystagmography (ENG), electrocochleography (ECoG), and dehydration testing was performed. Monitoring of hearing sensitivity, speech understanding, and ECoG responses following administration of a dehydrating agent were sensitive measures of cochlear function and confirmed the diagnosis of Meniere's disease. The induced changes also contributed to the therapeutic measures recommended.
journal_name
J Am Acad Audioljournal_title
Journal of the American Academy of Audiologyauthors
Yellin MW,Waller M,Roland PSsubject
Has Abstractpub_date
1993-11-01 00:00:00pages
432-6issue
6eissn
1050-0545issn
2157-3107journal_volume
4pub_type
杂志文章abstract:BACKGROUND:Tele-audiology provides a means to offer audiologic rehabilitation (AR) in a cost-, resource-, and time-effective manner. If designed appropriately, it also has the capability of personalizing rehabilitation to the user in terms of content, depth of detail, etc., thus permitting selection of the best content...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章,评审
doi:10.3766/jaaa.14062
更新日期:2015-10-01 00:00:00
abstract:BACKGROUND:Wideband reflectance (WBR) provides important information about middle ear function and can explain variations in how the middle ear receives, absorbs, and transmits sound energy across a wide range of frequencies. However, as of yet, few normative studies have been published to guide clinicians in the pract...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.19.5.4
更新日期:2008-05-01 00:00:00
abstract:BACKGROUND: Ecological momentary assessment (EMA) is a methodology involving repeated surveys to collect in-situ self-reports that describe respondents' current or recent experiences. Audiology literature comparing in-situ and retrospective self-reports is scarce. PURPOSE: To compare the sensitivity of in-situ and ret...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.1055/s-0040-1719133
更新日期:2020-12-15 00:00:00
abstract::Recent advances in endoscopic optics and miniature video camera technology have made video otoscopy (VO) accessible to audiologists in a practical way. Seven categories of VO applications are presented with clinical examples: (1) general examination of the earcanal and tympanic membrane, (2) physician communication/te...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1997-12-01 00:00:00
abstract::In studies to date, the effectiveness of the directional microphone has been investigated independently of the signal processing scheme used in the hearing aid. In addition, the number and placement of the background noise speakers can create an advantage for a particular polar pattern (i.e., cardioid, supercardioid, ...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:2001-11-01 00:00:00
abstract:BACKGROUND:Although audiologists have been using support personnel for over 45 yr, controversy and variability continue with respect to the entry-level education, training methods, and scope of practice. PURPOSE:As part of a larger clinical practices survey, this report focuses on use of audiology assistants (AAs) for...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章,多中心研究
doi:10.3766/jaaa.17004
更新日期:2018-05-01 00:00:00
abstract::The amplitude modulation-following response (AMFR), an auditory evoked potential elicited by continuous amplitude-modulated tones, can be recorded for carrier frequencies across the audiometric range. AMFR thresholds (based on the amplitude spectra of the responses) have been found to closely follow behavioral thresho...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1993-01-01 00:00:00
abstract::The Words-in-Noise (WIN) test uses monosyllabic words in seven signal-to-noise ratios of multitalker babble (MTB) to evaluate the ability of individuals to understand speech in background noise. The purpose of this study was to evaluate the criterion validity of the WIN by comparing recognition performances under MTB ...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.18.6.7
更新日期:2007-06-01 00:00:00
abstract:BACKGROUND:The scalp-recorded frequency-following response (FFR) has been widely accepted in assessing the brain's processing of speech stimuli for people who speak tonal and nontonal languages. Characteristics of scalp-recorded FFRs with increasing number of sweeps have been delineated through the use of an exponentia...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.16135
更新日期:2018-02-01 00:00:00
abstract::The Fusion at Inferred Threshold (FIT) test is a clinically useful procedure for assessing air-conduction pure-tone thresholds in any ear that may not be tested by conventional procedures with masking. It has not been widely reported in the literature. This article describes the FIT test procedure and provides four ca...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1998-06-01 00:00:00
abstract:BACKGROUND:Both wide dynamic range compression (WDRC) and ChannelFree (CF) processing strategies in hearing aids were designed to improve listener comfort and consonant identification, yet few studies have actually compared them. PURPOSE:To determine whether CF processing provides equal or better consonant identificat...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章,随机对照试验
doi:10.3766/jaaa.14057
更新日期:2015-07-01 00:00:00
abstract:BACKGROUND: Both the Roger remote microphone and on-ear, adaptive beamforming technologies (e.g., Phonak UltraZoom) have been shown to improve speech understanding in noise for cochlear implant (CI) listeners when tested in audio-only (A-only) test environments. PURPOSE: Our aim was to determine if adult and pediatric...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.1055/s-0040-1718893
更新日期:2020-12-09 00:00:00
abstract::Loudness discomfort levels (LDLs) were measured in dB HL and SPL at discrete frequencies between 500 to 4000 Hz on 31 hearing-impaired ears using TDH-50P and ER-3A earphones. The results revealed no significant differences in the measured sound pressure level (SPL) between the two earphones at all test frequencies. Ho...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1997-02-01 00:00:00
abstract:BACKGROUND:Binaural hearing improves our ability to understand speech and to localize sounds. Hearing loss can interfere with binaural cues, and despite the success of amplification, ∼25% of people with bilateral hearing loss fit with two hearing aids choose to wear only one (e.g., Brooks and Bulmer, 1981). One explana...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.22.3.6
更新日期:2011-03-01 00:00:00
abstract:PURPOSE:To present a case study in order to alert clinicians to the possibility of occurrence of intermodulation distortion during otoacoustic emissions testing that arises from the cavity formed by the external auditory meatus and tympanic membrane rather than from the inner ear, compromising the reliability and valid...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.20.5.3
更新日期:2009-05-01 00:00:00
abstract::The effect of feedback reduction (FBR) systems on sound quality recorded from two commercially available hearing aids was evaluated using paired comparison judgments by 16 participants with mild to severe sloping hearing loss. These comparisons were made with the FBR systems on and off without audible feedback and whi...
journal_title:Journal of the American Academy of Audiology
pub_type: 临床试验,杂志文章
doi:10.3766/jaaa.18.5.5
更新日期:2007-05-01 00:00:00
abstract:BACKGROUND/PURPOSE:The acceptable noise level (ANL) test is the only test that is known to predict success with hearing aids with a high degree of accuracy. A person's ANL is the maximal amount of background noise that he or she is "willing to put up with" while listening to running speech. It is defined as the speech ...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.25.6.10
更新日期:2014-06-01 00:00:00
abstract:BACKGROUND:For children with developmental delays (DDs) of any kind (e.g., global DDs, autism spectrum disorder, and Down syndrome), it is essential to understand if a hearing loss may be contributing to these delays. However, toddlers with DDs may have difficulty understanding directions, may be uncomfortable with a n...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.18070
更新日期:2020-05-01 00:00:00
abstract::The present investigation was conducted to help determine whether source activity of the direct recorded N1 response differed from that of the gamma band response (GBR). Auditory evoked cortical potential data from two patients with intractable epilepsy undergoing prolonged video EEG monitoring after implantation of s...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1998-04-01 00:00:00
abstract::This paper describes several techniques used to explore the role of cognitive factors in auditory performance in elderly adults. Two factors, cognitive slowing and age-related memory constraints, receive special attention. Assessing listeners' ability to report the content of time-compressed speech shows elderly adult...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1996-06-01 00:00:00
abstract::There have been scattered accounts reported in the oncology literature of progressive hearing loss following the conclusion of chemotherapy. In this case study, we report the audiologic findings of such a case. These data underscore the need for post-therapy monitoring in cases where threshold shifts are discovered du...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1993-11-01 00:00:00
abstract:BACKGROUND:Prior to undergoing vestibular function testing, it is not uncommon for clinicians to request that patients abstain from caffeine 24 hr prior to the administration of the tests. However, there is little evidence that caffeine affects vestibular function. PURPOSE:To evaluate whether the results from two test...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.25.3.5
更新日期:2014-03-01 00:00:00
abstract:BACKGROUND:In current practice, the status of residual low-frequency acoustic hearing in hearing preservation cochlear implantation (CI) is unknown until activation two to three weeks postoperatively. The intraoperatively measured electrically evoked compound action potential (ECAP), a synchronous response from electri...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.18052
更新日期:2019-11-01 00:00:00
abstract::A 48-item questionnaire was administered to 100 older adults to determine their expectations regarding hearing aid use. The sample consisted of volunteers from a variety of senior citizen organizations and ranged in age from 55 to 92 years. Only individuals who reported no prior hearing aid usage were included in the ...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1991-07-01 00:00:00
abstract:BACKGROUND:The acceptable noise level (ANL) serves to accurately predict the listener's likelihood of success with amplification. It has been proposed as a pre-hearing aid fitting protocol for hearing aid selection and counseling purposes. The ANL is a subjective measure of the listener's ability to accept background n...
journal_title:Journal of the American Academy of Audiology
pub_type: 临床试验,杂志文章
doi:10.3766/jaaa.23.7.5
更新日期:2012-07-01 00:00:00
abstract:BACKGROUND:Auditory fitness for duty (AFFD) testing is an important element in an assessment of workers' ability to perform job tasks safely and effectively. Functional hearing is particularly critical to job performance in law enforcement. Most often, assessment is based on pure-tone detection thresholds; however, its...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.22.6.2
更新日期:2011-06-01 00:00:00
abstract::The use of tone-burst stimuli for electrocochleography (ECochG) may offer certain advantages over conventional broad-band clicks. Namely, the summating potential (SP) component can be examined at different frequencies and may be easier to define and measure. To apply these findings clinically, it would first be necess...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1994-01-01 00:00:00
abstract::This paper describes the listening habits and musical enjoyment of postlingually deafened adults who use cochlear implants. Sixty-five implant recipients (35 females, 30 males) participated in a survey containing questions about musical background, prior involvement in music, and audiologic success with the implant in...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:2000-07-01 00:00:00
abstract::The cross-check principle was proposed by Jerger and Hayes over 20 years ago. Actually, the cross-check principle consists of a concept and a specific test protocol. The concept, that one test result confirms another test result, is still in use. Their specific protocol is essentially forgotten. The cross-check protoc...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章,评审
doi:
更新日期:2003-07-01 00:00:00
abstract::In this article we review, and discuss the clinical implications of, five projects currently underway in the Cochlear Implant Laboratory at Arizona State University. The projects are (1) norming the AzBio sentence test, (2) comparing the performance of bilateral and bimodal cochlear implant (CI) patients in realistic ...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.23.6.2
更新日期:2012-06-01 00:00:00