Abstract:
BACKGROUND:In current practice, the status of residual low-frequency acoustic hearing in hearing preservation cochlear implantation (CI) is unknown until activation two to three weeks postoperatively. The intraoperatively measured electrically evoked compound action potential (ECAP), a synchronous response from electrically stimulated auditory nerve fibers, is one of the first markers of auditory nerve function after cochlear implant surgery and such may provide information regarding the status of residual low-frequency acoustic hearing. PURPOSE:This study aimed to evaluate the relationship between intraoperative ECAP at the time of CI and presence of preoperative and postoperative low-frequency acoustic hearing. RESEARCH DESIGN:A retrospective case review. STUDY SAMPLE:Two hundred seventeen adult ears receiving CI (42 Advanced Bionics, 82 Cochlear, and 93 MED-EL implants). INTERVENTIONS:Intraoperative ECAP and CI. DATA COLLECTION AND ANALYSIS:ECAP measurements were obtained intraoperatively, whereas residual hearing data were obtained from postoperative CI activation audiogram. A linear mixed model test revealed no interaction effects for the following variables: manufacturer, electrode location (basal, middle, and apical), preoperative low-frequency pure-tone average (LFPTA), and postoperative LFPTA. The postoperative residual low-frequency hearing status was defined as preservation of unaided air conduction thresholds ≤90 dB at 250 Hz. Electrode location and hearing preservation data were analyzed individually for both the ECAP threshold and ECAP maximum amplitude using multiple t-tests, without assuming a consistent standard deviation between the groups, and with alpha correction. RESULTS:The maximum amplitude, in microvolts, was significantly higher throughout apical and middle regions of the cochlea in patients who had preserved low-frequency acoustic hearing as compared with those who did not have preserved hearing (p = 0.0001 and p = 0.0088, respectively). ECAP threshold, in microamperes, was significantly lower throughout the apical region of the cochlea in patients with preserved low-frequency acoustic hearing as compared with those without preserved hearing (p = 0.0099). Basal electrode maximum amplitudes and middle and basal electrode thresholds were not significantly correlated with postoperative low-frequency hearing. CONCLUSIONS:Apical and middle electrode maximum amplitudes and apical electrode thresholds detected through intraoperative ECAP measurements are significantly correlated with preservation of low-frequency acoustic hearing. This association may represent a potential immediate feedback mechanism for postoperative outcomes that can be applied to all CIs.
journal_name
J Am Acad Audioljournal_title
Journal of the American Academy of Audiologyauthors
Nassiri AM,Yawn RJ,Gifford RH,Haynes DS,Roberts JB,Gilbane MS,Murfee J,Bennett MLdoi
10.3766/jaaa.18052subject
Has Abstractpub_date
2019-11-01 00:00:00pages
918-926issue
10eissn
1050-0545issn
2157-3107journal_volume
30pub_type
杂志文章abstract:PURPOSE:Vestibular rehabilitation exercises have been proven to reduce symptoms and diminish the risk of falls in those with dizziness and balance impairments. The first purpose of this study is to investigate a new method of measuring head movements during habituation vestibular rehabilitation exercises. The second is...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.16026
更新日期:2018-01-01 00:00:00
abstract::In this article we review, and discuss the clinical implications of, five projects currently underway in the Cochlear Implant Laboratory at Arizona State University. The projects are (1) norming the AzBio sentence test, (2) comparing the performance of bilateral and bimodal cochlear implant (CI) patients in realistic ...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.23.6.2
更新日期:2012-06-01 00:00:00
abstract:BACKGROUND:We recently described a research study in which age-related changes in interaural asymmetry were elicited using the N400 of the auditory event-related potentials (AERP) (Davis et al, 2013). The N400 was the primary focus due to its sensitivity to various aspects of semantic processing (Kutas and Hillyard, 19...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.25.2.8
更新日期:2014-02-01 00:00:00
abstract:BACKGROUND:Untreated sensorineural hearing loss (SNHL) is associated with chronic health-care conditions, isolation, loneliness, and reduced quality of life. Although hearing aids can minimize the negative effects of SNHL, only about one in five persons with SNHL seeks help for communication problems. Many persons wait...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章,meta分析
doi:10.3766/jaaa.14076
更新日期:2016-04-01 00:00:00
abstract::In a clinical experiment, it was found that there is a high correlation between the compliance measured by tympanometry and the minimum size of the earmold vent, which just solves the client's occlusion problem related to his/her own voice when using a hearing aid. For ears with sensorineural hearing losses, complianc...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:2002-01-01 00:00:00
abstract::This paper describes several techniques used to explore the role of cognitive factors in auditory performance in elderly adults. Two factors, cognitive slowing and age-related memory constraints, receive special attention. Assessing listeners' ability to report the content of time-compressed speech shows elderly adult...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1996-06-01 00:00:00
abstract::The primary aim of the present study was to investigate parent satisfaction with a neonatal hearing screening program through use of a valid and reliable questionnaire developed for this purpose (Parent Satisfaction Questionnaire with Neonatal Hearing Screening Program; PSQ-NHSP). Eighty parents whose children had rec...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.17.4.4
更新日期:2006-04-01 00:00:00
abstract::A digital, wireless telephone system, the Global System for Mobile Communications (GSM), was introduced in Australia in 1993. Studies were conducted at the National Acoustic Laboratories to determine how the use of GSM mobile telephones (i.e., wireless telephones) causes interference in hearing aids and how hearing ai...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:2001-06-01 00:00:00
abstract:PURPOSE:To determine if one-octave multitone (MT) stimuli increase the amplitude of cortical auditory-evoked potentials (CAEPs) in individuals with a hearing loss when compared to standard pure-tone (PT) stimuli and narrow-band noise (NBN). RESEARCH DESIGN:CAEPs were obtained from 16 hearing-impaired adults in respons...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.15068
更新日期:2016-05-01 00:00:00
abstract:BACKGROUND:Tinnitus can have a devastating impact on the quality of life of the sufferer. Although the mechanisms underpinning tinnitus remain uncertain, hearing loss is often associated with its onset, and hearing aids are among the most commonly used tools for its management. PURPOSE:To conduct a scoping review to e...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.24.8.11
更新日期:2013-09-01 00:00:00
abstract:BACKGROUND:The acceptable noise level (ANL) serves to accurately predict the listener's likelihood of success with amplification. It has been proposed as a pre-hearing aid fitting protocol for hearing aid selection and counseling purposes. The ANL is a subjective measure of the listener's ability to accept background n...
journal_title:Journal of the American Academy of Audiology
pub_type: 临床试验,杂志文章
doi:10.3766/jaaa.23.7.5
更新日期:2012-07-01 00:00:00
abstract:BACKGROUND:Cervical and ocular vestibular-evoked myogenic potentials (VEMPs) have become common clinical vestibular assessments. However, VEMP testing requires high intensity stimuli, raising concerns regarding safety with children, where sound pressure levels may be higher due to their smaller ear canal volumes. PURP...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.15097
更新日期:2017-05-01 00:00:00
abstract::A 34-year-old female presented to our clinic with complaints of hearing loss, tinnitus, and severe rotational vertigo. A test battery including complete audiometric testing, auditory brainstem response (ABR) audiometry, electronystagmography (ENG), electrocochleography (ECoG), and dehydration testing was performed. Mo...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1993-11-01 00:00:00
abstract::The cross-check principle was proposed by Jerger and Hayes over 20 years ago. Actually, the cross-check principle consists of a concept and a specific test protocol. The concept, that one test result confirms another test result, is still in use. Their specific protocol is essentially forgotten. The cross-check protoc...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章,评审
doi:
更新日期:2003-07-01 00:00:00
abstract:BACKGROUND:Production effect (PE) is a memory phenomenon referring to better memory for produced (vocalized) than for non-produced (silently read) items. Reading aloud was found to improve verbal memory for normal-hearing individuals, as well as for cochlear implant users, studying visually and aurally presented materi...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.17030
更新日期:2018-11-01 00:00:00
abstract::The purpose of this study was to develop a test to assess the ability of persons with cochlear implants (CIs) to interpret musical signals. Up to this time, the main direction in outcomes studies of cochlear implantation has been in relation to speech recognition abilities. With improvement in CI hardware and processi...
journal_title:Journal of the American Academy of Audiology
pub_type: 临床试验,杂志文章
doi:10.3766/jaaa.19.1.6
更新日期:2008-01-01 00:00:00
abstract:BACKGROUND:The scalp-recorded frequency-following response (FFR) has been widely accepted in assessing the brain's processing of speech stimuli for people who speak tonal and nontonal languages. Characteristics of scalp-recorded FFRs with increasing number of sweeps have been delineated through the use of an exponentia...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.16135
更新日期:2018-02-01 00:00:00
abstract:BACKGROUND:Current fitting guidelines from the American Academy of Audiology (Academy) support the use of objective electroacoustic measures and behavioral testing when fitting frequency modulation (FM) systems to hearing aids. However, only behavioral testing is recommended when fitting FM systems to individuals with ...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.24.10.6
更新日期:2013-11-01 00:00:00
abstract::Skin disorders of the external ear are common. Although audiologists will not necessarily treat these conditions, it is important for them to be aware of these disorders and refer patients to a specialist in some instances. This report summarizes eight of the most commonly encountered skin conditions with an emphasis ...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章,评审
doi:10.3766/jaaa.19.3.6
更新日期:2008-03-01 00:00:00
abstract::The use of tone-burst stimuli for electrocochleography (ECochG) may offer certain advantages over conventional broad-band clicks. Namely, the summating potential (SP) component can be examined at different frequencies and may be easier to define and measure. To apply these findings clinically, it would first be necess...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1994-01-01 00:00:00
abstract::The Hearing-in-Noise Test (HINT) is able to measure the benefit to speech intelligibility in noise conferred when the noise masker is displaced 90 degrees in eccentricity from a speech source located at zero degrees azimuth. Both psychoacoustic and neurophysiological data suggest that the perceptual benefit of the 90-...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.14.9.7
更新日期:2003-11-01 00:00:00
abstract::In the last few years, a clinical consensus has emerged regarding the necessary components of an early management program for hearing-impaired children. Early detection of hearing loss, a parent-infant and supervised nursery program, and optimal amplification provisions are among these components. This paper explores ...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1992-01-01 00:00:00
abstract::Hearing loss is the most common of all disabilities in China, with three million of the 1.4 billion population affected. Recently, the release of an official neonatal hearing screening consensus has drawn attention to the importance of continued surveillance throughout childhood and the need for a system that is suite...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.16.9.6
更新日期:2005-10-01 00:00:00
abstract:BACKGROUND:Many studies have reported the speech recognition benefits of a personal remote microphone system when used by adult listeners with hearing loss. The advance of wireless technology has allowed for many wireless audio transmission protocols. Some of these protocols interface with commercially available hearin...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章,随机对照试验
doi:10.3766/jaaa.15008
更新日期:2015-09-01 00:00:00
abstract::The amplitude modulation-following response (AMFR), an auditory evoked potential elicited by continuous amplitude-modulated tones, can be recorded for carrier frequencies across the audiometric range. AMFR thresholds (based on the amplitude spectra of the responses) have been found to closely follow behavioral thresho...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1993-01-01 00:00:00
abstract::A speech test evaluation and presentation system is described. The test presentation subsystem has the flexibility and speed of live-voice testing while using recorded test materials. The speech test evaluation subsystem compares an individual subject's test performance on a monosyllabic word test with that of an aver...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1999-07-01 00:00:00
abstract:PURPOSE:To investigate the test-retest reliability of real-ear aided response (REAR) measures in open and closed hearing aid fittings in children using appropriate probe-microphone calibration techniques (stored equalization for open fittings and concurrent equalization for closed fittings). RESEARCH DESIGN:Probe-micr...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.24.7.11
更新日期:2013-07-01 00:00:00
abstract:BACKGROUND:In Sweden, there is a lack of evidence-based rehabilitation programs for hearing loss. The Active Communication Education program (ACE) has successfully been used in Australia and was translated and evaluated in a Swedish pilot study. The pilot study included 23 participants (age 87 yr). No statistically sig...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.25.9.7
更新日期:2014-10-01 00:00:00
abstract::The tolerability of aided impulsive-type stimuli was investigated in a group of 13 hearing-impaired listeners. Two linear circuits (one with a class A and one with a class D output stage) and one adaptive frequency response (AFR) circuit (with a class D output stage) were investigated. In a three-way paired-comparison...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1994-09-01 00:00:00
abstract:BACKGROUND:Evaluation of hearing-device signal-processing features is performed for research and development purposes, but also in clinical settings. Most people agree that the benefit experienced in a hearing-device user's daily life is most important, but laboratory tests are popular since they can be performed unifo...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.15105
更新日期:2016-07-01 00:00:00