The effect of middle age on the late positive component of the auditory event-related potential.

Abstract:

BACKGROUND:We recently described a research study in which age-related changes in interaural asymmetry were elicited using the N400 of the auditory event-related potentials (AERP) (Davis et al, 2013). The N400 was the primary focus due to its sensitivity to various aspects of semantic processing (Kutas and Hillyard, 1984), which we measured using a quasi-dichotic semantic category judgment task in competing speech. In this article, we describe age-related changes that occurred in the late positive component (LPC) of the AERP in the same study. The LPC peak occurs subsequent to the N400 peak on the AERP waveform and has been associated with context updating and further evaluation and processing of stimulus meaning (Juottonen et al, 1996). Neither age group showed significant interaural asymmetry in the LPC. However, a robust age-related difference in LPC scalp topography was observed. PURPOSE:The LPC of the auditory event-related potentials was utilized to evaluate age-related differences in language processing in a quasi-dichotic competing speech task. RESEARCH DESIGN:Electrophysiological responses were obtained on a word-pair semantic categorization task presented through a front loudspeaker while ignoring competing speech that was presented through either left (competition left [CL]) or right (competition right [CR]) loudspeakers. The LPC was compared between young and middle-aged groups in three conditions: side of competition, semantic judgment, and electrode position. STUDY SAMPLE:Twenty young (18-24 yr) and twenty middle-aged (44-57 yr) females with normal hearing sensitivity participated in this study. DATA COLLECTION AND ANALYSIS:Individual, as well as grand-averaged, AERP waveforms and scalp topographies were analyzed in response to the word pairs. The LPC component was subjected to a mixed design analysis of variance (ANOVA) for peak latency and amplitude measures in the latency range of 700-800 msec. Since statistical analyses showed little difference in the LPC component as a function of side of competition, the AERP data were collapsed for the CL and CR conditions. The LPC was analyzed in two ways: first at mid-parieto-central electrode locations, second across midline electrodes from PZ to FZ. RESULTS:Analysis of the mid-parieto-central electrodes showed no amplitude or latency differences for either group or side of competition. The second analysis (across midline electrodes), however, showed a significant amplitude interaction between electrode position and group, indicating that the two age groups were equivalent in the posterior region of the scalp but divergent as electrode site moved frontally. Significant age-related scalp topography differences were found in both semantic judgment conditions. No significant latency differences were found in any condition. CONCLUSIONS:The middle-aged group showed substantially greater LPC peak amplitude in the frontal regions of the scalp than young adults. These results were in concert with N400 results, which suggested that the middle-aged group required more attentional/cognitive resources than young adults in order to maintain a high performance level on a linguistic task in the presence of competing linguistic stimuli (Davis et al, 2013).

journal_name

J Am Acad Audiol

authors

Davis TM,Jerger J

doi

10.3766/jaaa.25.2.8

subject

Has Abstract

pub_date

2014-02-01 00:00:00

pages

199-209

issue

2

eissn

1050-0545

issn

2157-3107

journal_volume

25

pub_type

杂志文章
  • A FIT solution.

    abstract::The Fusion at Inferred Threshold (FIT) test is a clinically useful procedure for assessing air-conduction pure-tone thresholds in any ear that may not be tested by conventional procedures with masking. It has not been widely reported in the literature. This article describes the FIT test procedure and provides four ca...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Pope ML

    更新日期:1998-06-01 00:00:00

  • Exponential Modeling of Frequency-Following Responses in American Neonates and Adults.

    abstract:BACKGROUND:The scalp-recorded frequency-following response (FFR) has been widely accepted in assessing the brain's processing of speech stimuli for people who speak tonal and nontonal languages. Characteristics of scalp-recorded FFRs with increasing number of sweeps have been delineated through the use of an exponentia...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.16135

    authors: Jeng FC,Nance B,Montgomery-Reagan K,Lin CD

    更新日期:2018-02-01 00:00:00

  • Potential Benefits of an Integrated Electric-Acoustic Sound Processor with Children: A Preliminary Report.

    abstract:BACKGROUND:A number of published studies have demonstrated the benefits of electric-acoustic stimulation (EAS) over conventional electric stimulation for adults with functional low-frequency acoustic hearing and severe-to-profound high-frequency hearing loss. These benefits potentially include better speech recognition...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.15133

    authors: Wolfe J,Neumann S,Schafer E,Marsh M,Wood M,Baker RS

    更新日期:2017-02-01 00:00:00

  • The influence of aging on interaural asymmetries in middle latency response amplitude.

    abstract:BACKGROUND:Auditory-evoked potentials (EPs) provide a more objective assessment of central auditory nervous system (CANS) dysfunction when compared to behavioral measures because they do not require a behavioral response (Anderson and Kraus, 2010). In this regard, the middle latency response (MLR) has been considered a...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.25.4.4

    authors: Weihing J,Musiek F

    更新日期:2014-04-01 00:00:00

  • Spectrotemporal modulation sensitivity as a predictor of speech intelligibility for hearing-impaired listeners.

    abstract:BACKGROUND:A model that can accurately predict speech intelligibility for a given hearing-impaired (HI) listener would be an important tool for hearing-aid fitting or hearing-aid algorithm development. Existing speech-intelligibility models do not incorporate variability in suprathreshold deficits that are not well pre...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.24.4.5

    authors: Bernstein JG,Mehraei G,Shamma S,Gallun FJ,Theodoroff SM,Leek MR

    更新日期:2013-04-01 00:00:00

  • Within-subject comparison of speech perception benefits for congenitally deaf adolescents with an electrotactile speech processor and a cochlear implant.

    abstract::This study assessed speech perception benefits for three congenitally deaf adolescents who used an electrotactile speech processor (Tickle Talker(TM)) and subsequently went on to use a Nucleus Minisystem 22 cochlear implant. Both devices provided significant and comparable benefits for all children in the device plus ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Sarant J,Cowan R,Blamey P,Galvin K,Clark G

    更新日期:1996-04-01 00:00:00

  • Routine use of the crystal device integrity testing system in pediatric patients.

    abstract::Crystal Device Integrity Testing System (CITS), the first commercially available testing system of its type, allows rapid assessment of cochlear implant function by measuring averaged electrode voltages-the scalp-recorded fields generated by electrode currents. We describe our experience performing routine integrity t...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.17.10.4

    authors: Monin DL,Kazahaya K,Franck KH

    更新日期:2006-11-01 00:00:00

  • Cochlear implant microphone location affects speech recognition in diffuse noise.

    abstract:BACKGROUND:Despite improvements in cochlear implants (CIs), CI recipients continue to experience significant communicative difficulty in background noise. Many potential solutions have been proposed to help increase signal-to-noise ratio in noisy environments, including signal processing and external accessories. To da...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.26.1.6

    authors: Kolberg ER,Sheffield SW,Davis TJ,Sunderhaus LW,Gifford RH

    更新日期:2015-01-01 00:00:00

  • The Australian experience: global system for mobile communications wireless telephones and hearing aids.

    abstract::A digital, wireless telephone system, the Global System for Mobile Communications (GSM), was introduced in Australia in 1993. Studies were conducted at the National Acoustic Laboratories to determine how the use of GSM mobile telephones (i.e., wireless telephones) causes interference in hearing aids and how hearing ai...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Byrne D,Burwood E

    更新日期:2001-06-01 00:00:00

  • Development of hearing. Part III. Postnatal development.

    abstract::As humans, we hear the way we do because of at least three major forces. The first is phylogeny, the evolutionary changes in the auditory system since its beginnings. The second is embryology, the formation of the system in each individual. Finally, there is the interaction between the biologically determined mechanis...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,评审

    doi:

    authors: Peck JE

    更新日期:1995-03-01 00:00:00

  • A Comparison of Word-Recognition Performances on the Auditec and VA Recorded Versions of Northwestern University Auditory Test No. 6 by Young Listeners with Normal Hearing and by Older Listeners with Sensorineural Hearing Loss Using a Randomized Presentat

    abstract:BACKGROUND:The Auditec of St. Louis and the Department of Veterans Affairs (VA) recorded versions of the Northwestern University Auditory Test No. 6 (NU-6) are in common usage. Data on young adults with normal hearing for pure tones (YNH) demonstrate equal recognition performances on the two versions when the VA versio...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,随机对照试验

    doi:10.3766/jaaa.17135

    authors: Wilson RH

    更新日期:2019-05-01 00:00:00

  • Patient preferences and willingness to pay for tinnitus treatments.

    abstract:PURPOSE:There will likely be several different tinnitus treatments necessary, and it is important to understand patient preferences and factors that might contribute to treatment acceptability. This study explores the acceptability of a wide range of different tinnitus treatments, from noninvasive wearable devices to s...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.23.2.6

    authors: Tyler RS

    更新日期:2012-02-01 00:00:00

  • Effects of pre-existing hearing loss and gender on proposed ANSI S12.13 outcomes for characterizing hearing conservation program effectiveness: preliminary investigation.

    abstract::Draft American National Standard "Evaluating the Effectiveness of Hearing Conservation Programs" identifies potentially important links between audiometric threshold variability outcomes and occupational hearing conservation program (HCP) practices. Unacceptable threshold variability in annual audiograms may identify ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Amos NE,Simpson TH

    更新日期:1995-11-01 00:00:00

  • Estimating audiometric thresholds using auditory steady-state responses.

    abstract::Human auditory steady-state responses (ASSRs) were recorded using stimulus rates of 78-95 Hz in normal young subjects, in elderly subjects with relatively normal hearing, and in elderly subjects with sensorineural hearing impairment. Amplitude-intensity functions calculated relative to actual sensory thresholds (sensa...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.16.3.3

    authors: Picton TW,Dimitrijevic A,Perez-Abalo MC,Van Roon P

    更新日期:2005-03-01 00:00:00

  • Speech perception for adult cochlear implant recipients in a realistic background noise: effectiveness of preprocessing strategies and external options for improving speech recognition in noise.

    abstract:BACKGROUND:Although cochlear implant patients are achieving increasingly higher levels of performance, speech perception in noise continues to be problematic. The newest generations of implant speech processors are equipped with preprocessing and/or external accessories that are purported to improve listening in noise....

    journal_title:Journal of the American Academy of Audiology

    pub_type: 临床试验,杂志文章

    doi:10.3766/jaaa.21.7.3

    authors: Gifford RH,Revit LJ

    更新日期:2010-07-01 00:00:00

  • Psychoacoustic measures of tinnitus.

    abstract::This report reviews research from the 1930s to the present that has extended our understanding by investigating the characteristics of tinnitus that can be studied using psychoacoustic techniques. Studies of tinnitus masking and residual inhibition began in the 1970s, leading to the therapeutic use of tinnitus masking...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,评审

    doi:

    authors: Henry JA,Meikle MB

    更新日期:2000-03-01 00:00:00

  • Hearing and balance screening and referrals for Medicare patients: a national survey of primary care physicians.

    abstract::Hearing and balance problems are prevalent among the elderly. Primary care physicians (PCPs) are important pivotal points of entry for ensuring that patients receive needed audiology services. New Medicare beneficiaries are entitled to one-time preventative examinations including hearing/balance screenings. A 35-item ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.19.2.7

    authors: Johnson CE,Danhauer JL,Koch LL,Celani KE,Lopez IP,Williams VA

    更新日期:2008-02-01 00:00:00

  • Measuring Binaural Temporal-Fine-Structure Sensitivity in Hearing-Impaired Listeners, Using the TFS-AF Test.

    abstract:BACKGROUND:Various methods have been used to measure temporal-fine-structure (TFS) sensitivity in hearing-impaired (HI) listeners. A new method called TFS-adaptive frequency (TFS-AF) test, tracks the highest frequency up to which a person can detect a given interaural phase difference (IPD) in bursts of pure tones. So ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.18068

    authors: Mathew DS,Sreenivasan A,Alexander A,Palani S

    更新日期:2020-02-01 00:00:00

  • Hearing aid selection for the 1990s: where to?

    abstract::This paper discusses trends and issues in selecting amplification for new, mainly nonlinear, types of hearing aids. Some-concerns are that nonvalidated prescription formulae may proliferate; that, through concentration on loudness normalization, alternative rationales are not being evaluated; and that most new fitting...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,评审

    doi:

    authors: Byrne D

    更新日期:1996-12-01 00:00:00

  • An attempt to improve bilateral cochlear implants by increasing the distance between electrodes and providing complementary information to the two ears.

    abstract:OBJECTIVES:The purpose of this investigation was to determine if adult bilateral cochlear implant recipients could benefit from using a speech processing strategy in which the input spectrum was interleaved among electrodes across the two implants. DESIGN:Two separate experiments were conducted. In both experiments, s...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.21.1.7

    authors: Tyler RS,Witt SA,Dunn CC,Perreau A,Parkinson AJ,Wilson BS

    更新日期:2010-01-01 00:00:00

  • Recovery of speech perception performance after prolonged auditory deprivation: case study.

    abstract::The case reported here, a 26-year-old woman, has a bilaterally symmetric, severe-to-profound, sensorineural hearing loss, acquired early in life. Phoneme recognition scores were essentially symmetric at the onset of the investigation. She was basically monaurally aided from age 4 to age 24, at which time a loss of fun...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Boothroyd A

    更新日期:1993-09-01 00:00:00

  • Prescriptive hearing aid fitting by parameter adjustment and selection.

    abstract::We describe the rationale for the development of a psychophysical procedure that allows individual listeners to adjust the frequency-gain characteristic of a programmable hearing aid on a unidimensional scale, based on a target-gain reference value. The listener's task is to adjust the frequency response and select th...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Punch JL,Robb R

    更新日期:1992-03-01 00:00:00

  • Electrocochleography in the evaluation of patients with Ménière's disease/endolymphatic hydrops.

    abstract::Electrocochleography (ECochG) has evolved as an important tool in the diagnosis/assessment/monitoring of Ménière's disease/endolymphatic hydrops (MD/ELH). This manuscript provides an update on the use of ECochG for these purposes. The material presented includes descriptions of the components of the electrocochleogram...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,评审

    doi:10.3766/jaaa.17.1.6

    authors: Ferraro JA,Durrant JD

    更新日期:2006-01-01 00:00:00

  • Evidence against the influence of aging on distortion-product otoacoustic emissions.

    abstract::Previous research has reported reduced otoacoustic emission amplitude as a function of age. In each study, however, interpretation of findings was confounded by age-related hearing loss. The present study was designed to re-evaluate the contribution of age and peripheral hearing loss on the prevalence and amplitude of...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Strouse AL,Ochs MT,Hall JW 3rd

    更新日期:1996-10-01 00:00:00

  • Prediction and statistical evaluation of speech recognition test scores.

    abstract::A speech test evaluation and presentation system is described. The test presentation subsystem has the flexibility and speed of live-voice testing while using recorded test materials. The speech test evaluation subsystem compares an individual subject's test performance on a monosyllabic word test with that of an aver...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Studebaker GA,Gray GA,Branch WE

    更新日期:1999-07-01 00:00:00

  • Observations on the relations among occlusion effect, compliance, and vent size.

    abstract::In a clinical experiment, it was found that there is a high correlation between the compliance measured by tympanometry and the minimum size of the earmold vent, which just solves the client's occlusion problem related to his/her own voice when using a hearing aid. For ears with sensorineural hearing losses, complianc...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Carle R,Laugesen S,Nielsen C

    更新日期:2002-01-01 00:00:00

  • Recent changes in the etiology of hearing disorders: perinatal drug exposure.

    abstract::In recent years, we have observed causes of congenital or early onset hearing disorders that had not been recognized or known to exist before. These include drugs passed to an as-yet unborn child. Principal among them is alcohol, but others, such as cocaine, are now also occupying our attention. This article reviews t...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,评审

    doi:

    authors: Gerber SE,Epstein L,Mencher LS

    更新日期:1995-09-01 00:00:00

  • Evaluation of auditory functions for Royal Canadian Mounted Police officers.

    abstract:BACKGROUND:Auditory fitness for duty (AFFD) testing is an important element in an assessment of workers' ability to perform job tasks safely and effectively. Functional hearing is particularly critical to job performance in law enforcement. Most often, assessment is based on pure-tone detection thresholds; however, its...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.22.6.2

    authors: Vaillancourt V,Laroche C,Giguère C,Beaulieu MA,Legault JP

    更新日期:2011-06-01 00:00:00

  • A comparison of gain for adults from generic hearing aid prescriptive methods: impacts on predicted loudness, frequency bandwidth, and speech intelligibility.

    abstract:BACKGROUND:Prescriptive methods have been at the core of modern hearing aid fittings for the past several decades. Every decade or so, there have been revisions to existing methods and/or the emergence of new methods that become widely used. In 2001 Byrne et al provided a comparison of insertion gain for generic prescr...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.22.7.5

    authors: Johnson EE,Dillon H

    更新日期:2011-07-01 00:00:00

  • Video otoscopy in audiologic practice.

    abstract::Recent advances in endoscopic optics and miniature video camera technology have made video otoscopy (VO) accessible to audiologists in a practical way. Seven categories of VO applications are presented with clinical examples: (1) general examination of the earcanal and tympanic membrane, (2) physician communication/te...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Sullivan RF

    更新日期:1997-12-01 00:00:00