Cochlear implant microphone location affects speech recognition in diffuse noise.

Abstract:

BACKGROUND:Despite improvements in cochlear implants (CIs), CI recipients continue to experience significant communicative difficulty in background noise. Many potential solutions have been proposed to help increase signal-to-noise ratio in noisy environments, including signal processing and external accessories. To date, however, the effect of microphone location on speech recognition in noise has focused primarily on hearing aid users. PURPOSE:The purpose of this study was to (1) measure physical output for the T-Mic as compared with the integrated behind-the-ear (BTE) processor mic for various source azimuths, and (2) to investigate the effect of CI processor mic location for speech recognition in semi-diffuse noise with speech originating from various source azimuths as encountered in everyday communicative environments. RESEARCH DESIGN:A repeated-measures, within-participant design was used to compare performance across listening conditions. STUDY SAMPLE:A total of 11 adults with Advanced Bionics CIs were recruited for this study. DATA COLLECTION AND ANALYSIS:Physical acoustic output was measured on a Knowles Experimental Mannequin for Acoustic Research (KEMAR) for the T-Mic and BTE mic, with broadband noise presented at 0 and 90° (directed toward the implant processor). In addition to physical acoustic measurements, we also assessed recognition of sentences constructed by researchers at Texas Instruments, the Massachusetts Institute of Technology, and the Stanford Research Institute (TIMIT sentences) at 60 dBA for speech source azimuths of 0, 90, and 270°. Sentences were presented in a semi-diffuse restaurant noise originating from the R-SPACE 8-loudspeaker array. Signal-to-noise ratio was determined individually to achieve approximately 50% correct in the unilateral implanted listening condition with speech at 0°. Performance was compared across the T-Mic, 50/50, and the integrated BTE processor mic. RESULTS:The integrated BTE mic provided approximately 5 dB attenuation from 1500-4500 Hz for signals presented at 0° as compared with 90° (directed toward the processor). The T-Mic output was essentially equivalent for sources originating from 0 and 90°. Mic location also significantly affected sentence recognition as a function of source azimuth, with the T-Mic yielding the highest performance for speech originating from 0°. CONCLUSIONS:These results have clinical implications for (1) future implant processor design with respect to mic location, (2) mic settings for implant recipients, and (3) execution of advanced speech testing in the clinic.

journal_name

J Am Acad Audiol

authors

Kolberg ER,Sheffield SW,Davis TJ,Sunderhaus LW,Gifford RH

doi

10.3766/jaaa.26.1.6

subject

Has Abstract

pub_date

2015-01-01 00:00:00

pages

51-8; quiz 109-10

issue

1

eissn

1050-0545

issn

2157-3107

journal_volume

26

pub_type

杂志文章
  • Double checking the cross-check principle.

    abstract::The cross-check principle was proposed by Jerger and Hayes over 20 years ago. Actually, the cross-check principle consists of a concept and a specific test protocol. The concept, that one test result confirms another test result, is still in use. Their specific protocol is essentially forgotten. The cross-check protoc...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,评审

    doi:

    authors: Turner RG

    更新日期:2003-07-01 00:00:00

  • Use of the median method to enhance detection of the mismatch negativity in the responses of individual listeners.

    abstract::The median method was evaluated as an alternative way of expressing the mismatch negativity (MMN). Traditionally, signal averaging has been used to extract these event-related potentials from unwanted background noise. However, mean values are biased by unrejected artifact that skews the relatively small distribution ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Fox LG,Dalebout SD

    更新日期:2002-02-01 00:00:00

  • The effect of digital phase cancellation feedback reduction systems on amplified sound quality.

    abstract::The effect of feedback reduction (FBR) systems on sound quality recorded from two commercially available hearing aids was evaluated using paired comparison judgments by 16 participants with mild to severe sloping hearing loss. These comparisons were made with the FBR systems on and off without audible feedback and whi...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 临床试验,杂志文章

    doi:10.3766/jaaa.18.5.5

    authors: Johnson EE,Ricketts TA,Hornsby BW

    更新日期:2007-05-01 00:00:00

  • Prescriptive hearing aid fitting by parameter adjustment and selection.

    abstract::We describe the rationale for the development of a psychophysical procedure that allows individual listeners to adjust the frequency-gain characteristic of a programmable hearing aid on a unidimensional scale, based on a target-gain reference value. The listener's task is to adjust the frequency response and select th...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Punch JL,Robb R

    更新日期:1992-03-01 00:00:00

  • Considerations for cochlear implantation of children with sudden, fluctuating hearing loss.

    abstract::The histories of two pediatric patients who received cochlear implants with subsequent partial recovery of hearing in the nonimplanted ear are reviewed. One child had a sudden bilateral hearing loss, presumably secondary to autoimmune ear disease. The other child had a bilateral progressive hearing loss diagnosed as l...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.16.10.2

    authors: Sweetow RW,Rosbe KW,Philliposian C,Miller MT

    更新日期:2005-11-01 00:00:00

  • The influence of aging on interaural asymmetries in middle latency response amplitude.

    abstract:BACKGROUND:Auditory-evoked potentials (EPs) provide a more objective assessment of central auditory nervous system (CANS) dysfunction when compared to behavioral measures because they do not require a behavioral response (Anderson and Kraus, 2010). In this regard, the middle latency response (MLR) has been considered a...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.25.4.4

    authors: Weihing J,Musiek F

    更新日期:2014-04-01 00:00:00

  • Short- and long-term effects of the modified swedish version of the Active Communication Education (ACE) program for adults with hearing loss.

    abstract:BACKGROUND:In Sweden, there is a lack of evidence-based rehabilitation programs for hearing loss. The Active Communication Education program (ACE) has successfully been used in Australia and was translated and evaluated in a Swedish pilot study. The pilot study included 23 participants (age 87 yr). No statistically sig...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.25.9.7

    authors: Oberg M,Bohn T,Larsson U

    更新日期:2014-10-01 00:00:00

  • Implications of audiologic success.

    abstract::In the last few years, a clinical consensus has emerged regarding the necessary components of an early management program for hearing-impaired children. Early detection of hearing loss, a parent-infant and supervised nursery program, and optimal amplification provisions are among these components. This paper explores ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Ross M

    更新日期:1992-01-01 00:00:00

  • Comparison of probe insertion methods on estimates of ear canal SPL.

    abstract::Real-ear sound pressure levels (SPLs) were compared among three methods used for positioning a probe microphone in the ear canal. The probe insertion techniques included (1) an acoustic method that incorporates use of the quarter-wave anti-resonance property of the ear to determine acoustically the location of the pro...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Dirks DD,Ahlstrom JB,Eisenberg LS

    更新日期:1996-01-01 00:00:00

  • Connected Audiological Rehabilitation: 21st Century Innovations.

    abstract:BACKGROUND:Tele-audiology provides a means to offer audiologic rehabilitation (AR) in a cost-, resource-, and time-effective manner. If designed appropriately, it also has the capability of personalizing rehabilitation to the user in terms of content, depth of detail, etc., thus permitting selection of the best content...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,评审

    doi:10.3766/jaaa.14062

    authors: Saunders GH,Chisolm TH

    更新日期:2015-10-01 00:00:00

  • A Comparison of Word-Recognition Performances on the Auditec and VA Recorded Versions of Northwestern University Auditory Test No. 6 by Young Listeners with Normal Hearing and by Older Listeners with Sensorineural Hearing Loss Using a Randomized Presentat

    abstract:BACKGROUND:The Auditec of St. Louis and the Department of Veterans Affairs (VA) recorded versions of the Northwestern University Auditory Test No. 6 (NU-6) are in common usage. Data on young adults with normal hearing for pure tones (YNH) demonstrate equal recognition performances on the two versions when the VA versio...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,随机对照试验

    doi:10.3766/jaaa.17135

    authors: Wilson RH

    更新日期:2019-05-01 00:00:00

  • Evaluation of a "direct-comparison" approach to automatic switching in omnidirectional/directional hearing aids.

    abstract:BACKGROUND:Hearing aids today often provide both directional (DIR) and omnidirectional (OMNI) processing options with the currently active mode selected automatically by the device. The most common approach to automatic switching involves "acoustic scene analysis" where estimates of various acoustic properties of the l...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.19.9.6

    authors: Summers V,Grant KW,Walden BE,Cord MT,Surr RK,Elhilali M

    更新日期:2008-10-01 00:00:00

  • Big Stimulus, Little Ears: Safety in Administering Vestibular-Evoked Myogenic Potentials in Children.

    abstract:BACKGROUND:Cervical and ocular vestibular-evoked myogenic potentials (VEMPs) have become common clinical vestibular assessments. However, VEMP testing requires high intensity stimuli, raising concerns regarding safety with children, where sound pressure levels may be higher due to their smaller ear canal volumes. PURP...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.15097

    authors: Thomas MLA,Fitzpatrick D,McCreery R,Janky KL

    更新日期:2017-05-01 00:00:00

  • The effect of middle age on the late positive component of the auditory event-related potential.

    abstract:BACKGROUND:We recently described a research study in which age-related changes in interaural asymmetry were elicited using the N400 of the auditory event-related potentials (AERP) (Davis et al, 2013). The N400 was the primary focus due to its sensitivity to various aspects of semantic processing (Kutas and Hillyard, 19...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.25.2.8

    authors: Davis TM,Jerger J

    更新日期:2014-02-01 00:00:00

  • Acoustic hemifields in the spatial release from masking of speech by noise.

    abstract::The Hearing-in-Noise Test (HINT) is able to measure the benefit to speech intelligibility in noise conferred when the noise masker is displaced 90 degrees in eccentricity from a speech source located at zero degrees azimuth. Both psychoacoustic and neurophysiological data suggest that the perceptual benefit of the 90-...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.14.9.7

    authors: Phillips DP,Vigneault-MacLean BK,Boehnke SE,Hall SE

    更新日期:2003-11-01 00:00:00

  • Estimating audiometric thresholds using auditory steady-state responses.

    abstract::Human auditory steady-state responses (ASSRs) were recorded using stimulus rates of 78-95 Hz in normal young subjects, in elderly subjects with relatively normal hearing, and in elderly subjects with sensorineural hearing impairment. Amplitude-intensity functions calculated relative to actual sensory thresholds (sensa...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.16.3.3

    authors: Picton TW,Dimitrijevic A,Perez-Abalo MC,Van Roon P

    更新日期:2005-03-01 00:00:00

  • Potential Benefits of an Integrated Electric-Acoustic Sound Processor with Children: A Preliminary Report.

    abstract:BACKGROUND:A number of published studies have demonstrated the benefits of electric-acoustic stimulation (EAS) over conventional electric stimulation for adults with functional low-frequency acoustic hearing and severe-to-profound high-frequency hearing loss. These benefits potentially include better speech recognition...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.15133

    authors: Wolfe J,Neumann S,Schafer E,Marsh M,Wood M,Baker RS

    更新日期:2017-02-01 00:00:00

  • Technology, expectations, and adjustment to hearing loss: predictors of hearing aid outcome.

    abstract::This study examined the influence of technology, demographic factors, and prefitting expectations, attitudes, and adjustment to hearing loss on hearing aid outcome. Clients obtaining new hearing aids completed questionnaires measuring personal adjustment to hearing loss, expectations of and attitudes toward hearing ai...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Jerram JC,Purdy SC

    更新日期:2001-02-01 00:00:00

  • Loudness as a cue for acceptable noise levels.

    abstract:BACKGROUND/PURPOSE:The acceptable noise level (ANL) test is the only test that is known to predict success with hearing aids with a high degree of accuracy. A person's ANL is the maximal amount of background noise that he or she is "willing to put up with" while listening to running speech. It is defined as the speech ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.25.6.10

    authors: Recker KL,McKinney MF,Edwards BW

    更新日期:2014-06-01 00:00:00

  • Auditory brainstem response testing in neurodiagnosis: structure versus function.

    abstract::This case report describes a 44-yr-old female referred by an outside facility who presented with progressive hearing loss in her left ear. Magnetic resonance imaging (MRI) results were normal, but a battery of audiological tests suggested neural hearing loss in the left ear. Following diagnosis of left neural hearing ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.23.4.5

    authors: Peterein JL,Neely JG

    更新日期:2012-04-01 00:00:00

  • Differences and intersubject variability of loudness discomfort levels measured in sound pressure level and hearing level for TDH-50P and ER-3A earphones.

    abstract::Loudness discomfort levels (LDLs) were measured in dB HL and SPL at discrete frequencies between 500 to 4000 Hz on 31 hearing-impaired ears using TDH-50P and ER-3A earphones. The results revealed no significant differences in the measured sound pressure level (SPL) between the two earphones at all test frequencies. Ho...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Valente M,Potts LG,Valente M

    更新日期:1997-02-01 00:00:00

  • Multiple-ASSR thresholds in infants and young children with hearing loss.

    abstract:BACKGROUND:The multiple auditory steady-state response (multiple ASSR) is a promising technique for determining thresholds for infants and children. However, there are few data for infants and young children with hearing loss where multiple-ASSR thresholds have been compared to frequency-specific gold standard (i.e., b...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.21.8.5

    authors: Van Maanen A,Stapells DR

    更新日期:2010-09-01 00:00:00

  • Attend to this: the relationship between auditory processing disorders and attention deficits.

    abstract:BACKGROUND:Children clinically diagnosed with auditory processing disorders (APDs) are often described as easily distracted and inattentive, leading some researchers to propose that APDs might be a consequence of underlying attention difficulties or a subtype of attention disorders. PURPOSE:The aim of this study was t...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.25.7.6

    authors: Gyldenkærne P,Dillon H,Sharma M,Purdy SC

    更新日期:2014-07-01 00:00:00

  • Auditory brainstem responses elicited by 1000-Hz tone bursts in patients with sensorineural hearing loss.

    abstract::Auditory brainstem responses were measured in response to 1000-Hz tone bursts from 115 patients with sensorineural hearing loss, presumably of cochlear origin. Mean wave V latencies and variability were comparable to those observed in normal hearing subjects for similar stimuli. The range of interaural differences in ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Gorga MP,Kaminski JR,Beauchaine KL,Schulte L

    更新日期:1992-05-01 00:00:00

  • Hearing-aid-processed tone pips: electroacoustic and ABR characteristics.

    abstract::The auditory brainstem response (ABR) recorded while wearing a hearing aid may supply supplemental information about the benefit and appropriateness of the hearing aid for certain infants. The purposes of this study were (1) to determine the effects of different output limiting circuits on the acoustics of tone-pip st...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Brown E,Klein AJ,Snydee KA

    更新日期:1999-04-01 00:00:00

  • The need for and development of an adaptive Listening and Communication Enhancement (LACE) Program.

    abstract::Auditory training has long been advocated to enhance communication but has never been time or cost-effective. This article describes the concepts underlying the development of a home-based, interactive adaptive computer program designed to engage the adult hearing-impaired listener in the hearing-aid-fitting process, ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,随机对照试验

    doi:10.3766/jaaa.17.8.2

    authors: Sweetow RW,Sabes JH

    更新日期:2006-09-01 00:00:00

  • Knowledge of Hearing Loss among University Students Pursuing Careers in Health Care.

    abstract:BACKGROUND:Albeit limited, research suggests that students pursuing careers in health care receive limited training on the provision of services for people with hearing loss. As the incidence of hearing loss continues to increase among Americans, it is critical that medical professionals understand how hearing loss amo...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.17071

    authors: Squires ES,Pakulski LA,Glassman J,Diehm E

    更新日期:2019-04-01 00:00:00

  • Prediction and statistical evaluation of speech recognition test scores.

    abstract::A speech test evaluation and presentation system is described. The test presentation subsystem has the flexibility and speed of live-voice testing while using recorded test materials. The speech test evaluation subsystem compares an individual subject's test performance on a monosyllabic word test with that of an aver...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Studebaker GA,Gray GA,Branch WE

    更新日期:1999-07-01 00:00:00

  • The Chinese Hearing Questionnaire for School Children.

    abstract::Hearing loss is the most common of all disabilities in China, with three million of the 1.4 billion population affected. Recently, the release of an official neonatal hearing screening consensus has drawn attention to the importance of continued surveillance throughout childhood and the need for a system that is suite...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.16.9.6

    authors: Bu X,Li X,Driscoll C

    更新日期:2005-10-01 00:00:00

  • Interaural asymmetries revealed by dichotic listening tests in normal and dyslexic children.

    abstract::Normal and dyslexic right-handed children were assessed with three dichotic listening tests, the Dichotic Digits test, the Competing Words subtest of the SCAN, and the Dichotic Consonant-Vowel test. Performance was measured as both number and percentage of correct responses in the right and left ears. Laterality was d...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Moncrieff DW,Musiek FE

    更新日期:2002-09-01 00:00:00