Auditory brainstem responses elicited by 1000-Hz tone bursts in patients with sensorineural hearing loss.

Abstract:

:Auditory brainstem responses were measured in response to 1000-Hz tone bursts from 115 patients with sensorineural hearing loss, presumably of cochlear origin. Mean wave V latencies and variability were comparable to those observed in normal hearing subjects for similar stimuli. The range of interaural differences in wave V latencies for 1000-Hz tone bursts were slightly greater than those observed for clicks, which may not be surprising, given the greater variability in wave V latencies for tonal stimulation, even in normal-hearing subjects. These differences, however, were not affected either by the magnitude or symmetry of hearing loss for frequencies at and above 1000 Hz. These data suggest that tone burst ABRs might be useful in otoneurologic evaluations, especially for patients with asymmetric hearing loss.

journal_name

J Am Acad Audiol

authors

Gorga MP,Kaminski JR,Beauchaine KL,Schulte L

keywords:

subject

Has Abstract

pub_date

1992-05-01 00:00:00

pages

159-65

issue

3

eissn

1050-0545

issn

2157-3107

journal_volume

3

pub_type

杂志文章
  • Observations on the relations among occlusion effect, compliance, and vent size.

    abstract::In a clinical experiment, it was found that there is a high correlation between the compliance measured by tympanometry and the minimum size of the earmold vent, which just solves the client's occlusion problem related to his/her own voice when using a hearing aid. For ears with sensorineural hearing losses, complianc...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Carle R,Laugesen S,Nielsen C

    更新日期:2002-01-01 00:00:00

  • A FIT solution.

    abstract::The Fusion at Inferred Threshold (FIT) test is a clinically useful procedure for assessing air-conduction pure-tone thresholds in any ear that may not be tested by conventional procedures with masking. It has not been widely reported in the literature. This article describes the FIT test procedure and provides four ca...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Pope ML

    更新日期:1998-06-01 00:00:00

  • Normal summating potential to tone bursts recorded from the tympanic membrane in humans.

    abstract::The use of tone-burst stimuli for electrocochleography (ECochG) may offer certain advantages over conventional broad-band clicks. Namely, the summating potential (SP) component can be examined at different frequencies and may be easier to define and measure. To apply these findings clinically, it would first be necess...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Ferraro JA,Blackwell WL,Mediavilla SJ,Thedinger BS

    更新日期:1994-01-01 00:00:00

  • Electrocochleography in the evaluation of patients with Ménière's disease/endolymphatic hydrops.

    abstract::Electrocochleography (ECochG) has evolved as an important tool in the diagnosis/assessment/monitoring of Ménière's disease/endolymphatic hydrops (MD/ELH). This manuscript provides an update on the use of ECochG for these purposes. The material presented includes descriptions of the components of the electrocochleogram...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,评审

    doi:10.3766/jaaa.17.1.6

    authors: Ferraro JA,Durrant JD

    更新日期:2006-01-01 00:00:00

  • Routine use of the crystal device integrity testing system in pediatric patients.

    abstract::Crystal Device Integrity Testing System (CITS), the first commercially available testing system of its type, allows rapid assessment of cochlear implant function by measuring averaged electrode voltages-the scalp-recorded fields generated by electrode currents. We describe our experience performing routine integrity t...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.17.10.4

    authors: Monin DL,Kazahaya K,Franck KH

    更新日期:2006-11-01 00:00:00

  • Central auditory processing in a patient with bilateral temporal lobe tumors: case report.

    abstract::The purpose of this article is to report the audiologic and central auditory processing abilities of a 34-year-old male with a right temporal lobe tumor and a history of bilateral tumors of the temporal lobes. The patient was evaluated presurgical re-exploration and again at 2.5 months and 4 months postoperatively. Te...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Fallis-Cunningham R,Keith RW,Warnick RE

    更新日期:1998-08-01 00:00:00

  • Prediction and statistical evaluation of speech recognition test scores.

    abstract::A speech test evaluation and presentation system is described. The test presentation subsystem has the flexibility and speed of live-voice testing while using recorded test materials. The speech test evaluation subsystem compares an individual subject's test performance on a monosyllabic word test with that of an aver...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Studebaker GA,Gray GA,Branch WE

    更新日期:1999-07-01 00:00:00

  • Hearing aid selection for the 1990s: where to?

    abstract::This paper discusses trends and issues in selecting amplification for new, mainly nonlinear, types of hearing aids. Some-concerns are that nonvalidated prescription formulae may proliferate; that, through concentration on loudness normalization, alternative rationales are not being evaluated; and that most new fitting...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,评审

    doi:

    authors: Byrne D

    更新日期:1996-12-01 00:00:00

  • Speech perception for adult cochlear implant recipients in a realistic background noise: effectiveness of preprocessing strategies and external options for improving speech recognition in noise.

    abstract:BACKGROUND:Although cochlear implant patients are achieving increasingly higher levels of performance, speech perception in noise continues to be problematic. The newest generations of implant speech processors are equipped with preprocessing and/or external accessories that are purported to improve listening in noise....

    journal_title:Journal of the American Academy of Audiology

    pub_type: 临床试验,杂志文章

    doi:10.3766/jaaa.21.7.3

    authors: Gifford RH,Revit LJ

    更新日期:2010-07-01 00:00:00

  • Audiologic monitoring for potential ototoxicity in a phase I clinical trial of a new glycopeptide antibiotic.

    abstract::This study describes audiologic methodology and results for evaluating potential ototoxicity in a phase I clinical trial of a new glycopeptide. This study was conducted under good clinical practices, which are regulated by the US Food and Drug Administration (FDA) (21 Code of Federal Regulations), and input from the F...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:

    authors: Campbell KC,Kelly E,Targovnik N,Hughes L,Van Saders C,Gottlieb AB,Dorr MB,Leighton A

    更新日期:2003-04-01 00:00:00

  • Reception thresholds for sentences in quiet and noise for monolingual English and bilingual Mandarin-English listeners.

    abstract:BACKGROUND:Bilingual (BL) listeners' difficulties in adverse noise conditions are exacerbated when perceiving their second language (L2) relative to their first language (L1). Perception of L2 is also significantly poorer by BL listeners compared to native monolingual (ML) listeners. PURPOSE:The purpose of the study w...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.21.4.3

    authors: Stuart A,Zhang J,Swink S

    更新日期:2010-04-01 00:00:00

  • Brief tone discrimination by children with histories of early otitis media.

    abstract::Twelve children, ranging in age from 8.9 to 12.4 years, with histories of severe otitis media with effusion (OME) before age 3, were compared to age-matched cohorts in their ability to discriminate the frequency of tone pulses of 20-, 50-, and 200-msec duration. An adaptive procedure was used in combination with a two...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Cranford JL,Thompson N,Hoyer E,Faires W

    更新日期:1997-04-01 00:00:00

  • Expectations of older adults regarding the use of hearing aids.

    abstract::A 48-item questionnaire was administered to 100 older adults to determine their expectations regarding hearing aid use. The sample consisted of volunteers from a variety of senior citizen organizations and ranged in age from 55 to 92 years. Only individuals who reported no prior hearing aid usage were included in the ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Kricos PB,Lesner SA,Sandridge SA

    更新日期:1991-07-01 00:00:00

  • Comparison of probe insertion methods on estimates of ear canal SPL.

    abstract::Real-ear sound pressure levels (SPLs) were compared among three methods used for positioning a probe microphone in the ear canal. The probe insertion techniques included (1) an acoustic method that incorporates use of the quarter-wave anti-resonance property of the ear to determine acoustically the location of the pro...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Dirks DD,Ahlstrom JB,Eisenberg LS

    更新日期:1996-01-01 00:00:00

  • Masking redux. II: A recommended masking protocol.

    abstract::This is the second in a series of two papers on masking. The objective of these papers is to develop a masking protocol that provides valid measures of threshold and is, in general, faster than the plateau method. In the first paper, a masking method was presented that can replace the traditional plateau method in mos...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.15.1.5

    authors: Turner RG

    更新日期:2004-01-01 00:00:00

  • Probe-microphone measurements with body-worn instruments: loudspeaker and reference microphone effects.

    abstract::Probe-microphone measurements are typically made with behind-the-ear (BTE) and in-the-ear (ITE) hearing aids with the loudspeaker located at 0-degrees or 45-degrees azimuth at head level and the reference microphone positioned on the head near the hearing aid microphone. With body-worn instruments, these conditions ma...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Nelson JA,Hawkins DB

    更新日期:1994-03-01 00:00:00

  • Optimizing the benefit of sound processors coupled to personal FM systems.

    abstract:BACKGROUND:Use of personal frequency modulated (FM) systems significantly improves speech recognition in noise for users of cochlear implants (CI). There are, however, a number of adjustable parameters of the cochlear implant and FM receiver that may affect performance and benefit, and there is limited evidence to guid...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 临床试验,杂志文章

    doi:10.3766/jaaa.19.8.2

    authors: Wolfe J,Schafer EC

    更新日期:2008-09-01 00:00:00

  • The Australian experience: global system for mobile communications wireless telephones and hearing aids.

    abstract::A digital, wireless telephone system, the Global System for Mobile Communications (GSM), was introduced in Australia in 1993. Studies were conducted at the National Acoustic Laboratories to determine how the use of GSM mobile telephones (i.e., wireless telephones) causes interference in hearing aids and how hearing ai...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Byrne D,Burwood E

    更新日期:2001-06-01 00:00:00

  • Acoustic stapedial reflexes in healthy neonates: normative data and test-retest reliability.

    abstract:BACKGROUND:The acoustic stapedial reflex (ASR) test provides useful information about the function of the auditory system. While it is frequently used with adults and children in a clinical setting, its use with young infants is limited. Presently, there are few data for neonates and inadequate research into the test-r...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 临床试验,杂志文章

    doi:10.3766/jaaa.23.1.5

    authors: Kei J

    更新日期:2012-01-01 00:00:00

  • Intertester reliability of the acceptable noise level.

    abstract:BACKGROUND:The acceptable noise level (ANL) serves to accurately predict the listener's likelihood of success with amplification. It has been proposed as a pre-hearing aid fitting protocol for hearing aid selection and counseling purposes. The ANL is a subjective measure of the listener's ability to accept background n...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 临床试验,杂志文章

    doi:10.3766/jaaa.23.7.5

    authors: Gordon-Hickey S,Adams E,Moore R,Gaal A,Berry K,Brock S

    更新日期:2012-07-01 00:00:00

  • The masking-level difference in children.

    abstract::The masking-level difference (MLD) was investigated in children aged 3.9 to 9.5 years and in an adult control group in order to examine the development of the MLD with age. A three-alternative forced-choice adaptive tracking procedure was used for all listeners. MLDs were determined for a 500-Hz pure-tone signal prese...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Hall JW 3rd,Grose JH

    更新日期:1990-04-01 00:00:00

  • Audiometric correlates of the unaided APHAB.

    abstract::The Abbreviated Profile of Hearing Aid Benefit (APHAB) is a self-report questionnaire that is used to quantify the impact of a hearing problem on an individual's daily life. In this investigation, the relationships were explored between typical clinical audiometric data and the four subscale scores of the APHAB admini...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Cox RM,Alexander GC,Gray GA

    更新日期:2003-09-01 00:00:00

  • Current research with cochlear implants at Arizona State University.

    abstract::In this article we review, and discuss the clinical implications of, five projects currently underway in the Cochlear Implant Laboratory at Arizona State University. The projects are (1) norming the AzBio sentence test, (2) comparing the performance of bilateral and bimodal cochlear implant (CI) patients in realistic ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.23.6.2

    authors: Dorman MF,Spahr A,Gifford RH,Cook S,Zhang T,Loiselle L,Yost W,Cardy L,Whittingham J,Schramm D

    更新日期:2012-06-01 00:00:00

  • Behavioral characteristics of auditory processing disorder and attention-deficit hyperactivity disorder: predominantly inattentive type.

    abstract::Auditory processing disorder (APD) and attention-deficit hyperactivity disorder (ADHD) present overlapping symptomatology. Previous research has demonstrated that professionals use different behavioral descriptors to characterize APD and ADHD combined and predominantly hyperactive-impulsive subtypes, which present wit...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Chermak GD,Tucker E,Seikel JA

    更新日期:2002-06-01 00:00:00

  • An attempt to improve bilateral cochlear implants by increasing the distance between electrodes and providing complementary information to the two ears.

    abstract:OBJECTIVES:The purpose of this investigation was to determine if adult bilateral cochlear implant recipients could benefit from using a speech processing strategy in which the input spectrum was interleaved among electrodes across the two implants. DESIGN:Two separate experiments were conducted. In both experiments, s...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.21.1.7

    authors: Tyler RS,Witt SA,Dunn CC,Perreau A,Parkinson AJ,Wilson BS

    更新日期:2010-01-01 00:00:00

  • The Middle Latency Response: A Review of Findings in Various Central Nervous System Lesions.

    abstract:BACKGROUND:The middle latency response (MLR) first came to light as an auditory evoked potential in 1958. Since then, it has aroused substantial interest and investigation by clinicians and researchers alike. In recent history, its use and popularity have dwindled in tandem with various other auditory evoked potentials...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.16141

    authors: Musiek F,Nagle S

    更新日期:2018-10-01 00:00:00

  • Implications of audiologic success.

    abstract::In the last few years, a clinical consensus has emerged regarding the necessary components of an early management program for hearing-impaired children. Early detection of hearing loss, a parent-infant and supervised nursery program, and optimal amplification provisions are among these components. This paper explores ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Ross M

    更新日期:1992-01-01 00:00:00

  • Rate, frequency, and intensity effects on early auditory evoked potentials and binaural interaction component in humans.

    abstract::The binaural interaction component (BIC) of the auditory brainstem response (ABR) and BIC of the frequency-following response (FFR) to tonal stimuli were studied in normal-hearing adults. The ABR and BIC latencies from all subjects were consistently shorter to the click-like sound than to the 2.0 kHz tone burst. Incre...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Parthasarathy TK,Moushegian G

    更新日期:1993-07-01 00:00:00

  • Conductive hearing loss and middle ear pathology in young infants referred through a newborn universal hearing screening program in Australia.

    abstract:BACKGROUND:Although newborn hearing screening programs have been introduced in most states in Australia, the prevalence of conductive hearing loss and middle ear pathology in the infants referred through these programs is not known. PURPOSE:This study was designed to (1) evaluate the prevalence of conductive hearing l...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.23.9.2

    authors: Aithal S,Aithal V,Kei J,Driscoll C

    更新日期:2012-10-01 00:00:00

  • Investigating speechreading and deafness.

    abstract:BACKGROUND:The visual speech signal can provide sufficient information to support successful communication. However, individual differences in the ability to appreciate that information are large, and relatively little is known about their sources. PURPOSE:Here a body of research is reviewed regarding the development ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,评审

    doi:10.3766/jaaa.21.3.4

    authors: Auer ET