A Comparison of Word-Recognition Performances on the Auditec and VA Recorded Versions of Northwestern University Auditory Test No. 6 by Young Listeners with Normal Hearing and by Older Listeners with Sensorineural Hearing Loss Using a Randomized Presentat

Abstract:

BACKGROUND:The Auditec of St. Louis and the Department of Veterans Affairs (VA) recorded versions of the Northwestern University Auditory Test No. 6 (NU-6) are in common usage. Data on young adults with normal hearing for pure tones (YNH) demonstrate equal recognition performances on the two versions when the VA version is presented 5 dB higher but similar data on older listeners with sensorineural hearing loss (OHL) are lacking. PURPOSE:To compare word-recognition performances on the Auditec and VA versions of NU-6 presented at six presentation levels with YNH and OHL listeners. RESEARCH DESIGN:A quasi-experimental, repeated-measures design was used. STUDY SAMPLE:Twelve YNH (M = 24.0 years; PTA = 9.9-dB HL) and 36 OHL listeners (M = 71.6 years; PTA = 26.7-dB HL) participated in three, one-hour sessions. DATA COLLECTION AND ANALYSES:Each listener received 100 stimulus words that were randomized by 6 presentation levels for each of two speakers (YNH, -2 to 28-dB SL; OHL, -2 to 38-dB SL). The sessions were limited to 25 practice and 400 experimental words. Digital versions of the 16, 25-word tracks for each session were alternated between speakers. RESULTS:Each of the 48 listeners had higher recognition performances on the Auditec version of NU-6 than on the VA version. The respective overall recognition performances on the Auditec and VA versions were 71.4% and 64.1% (YNH) and 68.7% and 58.2% (OHL). At the highest presentation levels, recognition performances on the two versions differed by only 0.5% (YNH) and 3.3% (OHL). At the 50% correct point, performances on the Auditec version were 3.2 dB (YNH) and 6.1 dB (OHL) better than those on the VA version. The slopes at the 50% points on the mean functions for both speakers were about 4.9%/dB (YNH) and 3.0%/dB (OHL); however, the slopes evaluated from the individual listener data were steeper, 5.2 to 5.3%/dB (YNH) and 3.3 to 3.5%/dB (OHL). When the individual data were transformed from dB SL to dB HL, the differences between the two listener groups were emphasized. The four functions (2 speakers by 2 listener groups) were plotted for each of the 48 participants and each of the 200 words, which revealed the gamut of relations among the datasets. Examination of the data for each speaker across test sessions, in the traditional 50-word lists, and in the typically used 25-word lists of Randomization A revealed no differences of clinical concern. Finally, introspective reports from the listeners revealed that 91.7% and 83.3% of the YNH and OHL listeners, respectively, thought the Auditec speaker was easier to understand than the VA speaker. Recognition performances on each participant and on each word are presented.

journal_name

J Am Acad Audiol

authors

Wilson RH

doi

10.3766/jaaa.17135

subject

Has Abstract

pub_date

2019-05-01 00:00:00

pages

370-395

issue

5

eissn

1050-0545

issn

2157-3107

journal_volume

30

pub_type

杂志文章,随机对照试验
  • The recordability of two sonomotor responses in young normal subjects.

    abstract:BACKGROUND:It has been reported that up to 40% of patients over age 60 fail to generate a vestibular evoked myogenic potential (VEMP; Su et al, 2004). When this occurs it is difficult to determine whether the absent VEMP represents evidence of bilateral impairment of the vestibulocollic reflex pathway or a normal age-r...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.19.7.3

    authors: McCaslin DL,Jacobson GP,Harry T

    更新日期:2008-07-01 00:00:00

  • Comparison of probe insertion methods on estimates of ear canal SPL.

    abstract::Real-ear sound pressure levels (SPLs) were compared among three methods used for positioning a probe microphone in the ear canal. The probe insertion techniques included (1) an acoustic method that incorporates use of the quarter-wave anti-resonance property of the ear to determine acoustically the location of the pro...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Dirks DD,Ahlstrom JB,Eisenberg LS

    更新日期:1996-01-01 00:00:00

  • Efficacy of directional microphone hearing aids: a meta-analytic perspective.

    abstract::The literature suggests that directional microphone hearing aids (DMHAs) are a viable means for improving the signal-to-noise ratio (SNR) for hearing-impaired listeners. The amount of directional advantage they provide, however, remains relatively unclear because of variability observed among individual studies. The p...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,meta分析

    doi:

    authors: Amlani AM

    更新日期:2001-04-01 00:00:00

  • Listener Performance with a Novel Hearing Aid Frequency Lowering Technique.

    abstract:BACKGROUND:Sloping hearing loss imposes limits on audibility for high-frequency sounds in many hearing aid users. Signal processing algorithms that shift high-frequency sounds to lower frequencies have been introduced in hearing aids to address this challenge by improving audibility of high-frequency sounds. PURPOSE:T...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 临床试验,杂志文章

    doi:10.3766/jaaa.16157

    authors: Kirby BJ,Kopun JG,Spratford M,Mollak CM,Brennan MA,McCreery RW

    更新日期:2017-10-01 00:00:00

  • Speech Understanding and Sound Source Localization by Cochlear Implant Listeners Using a Pinna-Effect Imitating Microphone and an Adaptive Beamformer.

    abstract:BACKGROUND:Sentence understanding scores for patients with cochlear implants (CIs) when tested in quiet are relatively high. However, sentence understanding scores for patients with CIs plummet with the addition of noise. PURPOSE:To assess, for patients with CIs (MED-EL), (1) the value to speech understanding of two n...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.16126

    authors: Dorman MF,Natale S,Loiselle L

    更新日期:2018-03-01 00:00:00

  • Hearing aid selection for the 1990s: where to?

    abstract::This paper discusses trends and issues in selecting amplification for new, mainly nonlinear, types of hearing aids. Some-concerns are that nonvalidated prescription formulae may proliferate; that, through concentration on loudness normalization, alternative rationales are not being evaluated; and that most new fitting...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,评审

    doi:

    authors: Byrne D

    更新日期:1996-12-01 00:00:00

  • The Association between Hearing Loss, Postural Control, and Mobility in Older Adults: A Systematic Review.

    abstract:BACKGROUND:Degraded hearing in older adults has been associated with reduced postural control and higher risk of falls. Both hearing loss (HL) and falls have dramatic effects on older persons' quality of life (QoL). A large body of research explored the comorbidity between the two domains. PURPOSE:The aim of the curre...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,评审

    doi:10.3766/jaaa.16044

    authors: Agmon M,Lavie L,Doumas M

    更新日期:2017-06-01 00:00:00

  • Human frequency-following response correlates of the distortion product at 2F1-F2.

    abstract::We characterized the 2F1-F2 distortion product reflected in the human frequency-following response (FFR). In the first experiment, we evaluated the input-output growth functions of the distortion product at 2F1-F2 (FFR-DP) for three primary pairs. In the second experiment, we tested the effect of primary tone level va...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.15.3.2

    authors: Pandya PK,Krishnan A

    更新日期:2004-03-01 00:00:00

  • The Effect of Presentation Mode and Production Type on Word Memory for Hearing Impaired Signers.

    abstract:BACKGROUND:Production effect (PE) is a memory phenomenon referring to better memory for produced (vocalized) than for non-produced (silently read) items. Reading aloud was found to improve verbal memory for normal-hearing individuals, as well as for cochlear implant users, studying visually and aurally presented materi...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.17030

    authors: Swead RT,Mama Y,Icht M

    更新日期:2018-11-01 00:00:00

  • Prescriptive hearing aid fitting by parameter adjustment and selection.

    abstract::We describe the rationale for the development of a psychophysical procedure that allows individual listeners to adjust the frequency-gain characteristic of a programmable hearing aid on a unidimensional scale, based on a target-gain reference value. The listener's task is to adjust the frequency response and select th...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Punch JL,Robb R

    更新日期:1992-03-01 00:00:00

  • Outcome survey of auditory-verbal graduates: study of clinical efficacy.

    abstract::Audiologists must be knowledgeable about the efficacy of aural habilitation practices because we are often the first professionals to inform parents about their child's hearing impairment. The purpose of this investigation was to document the status of graduates of one aural habilitation option; auditory-verbal. A con...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Goldberg DM,Flexer C

    更新日期:1993-05-01 00:00:00

  • Intraoperative Electrically Evoked Compound Action Potential (ECAP) Measurements in Traditional and Hearing Preservation Cochlear Implantation.

    abstract:BACKGROUND:In current practice, the status of residual low-frequency acoustic hearing in hearing preservation cochlear implantation (CI) is unknown until activation two to three weeks postoperatively. The intraoperatively measured electrically evoked compound action potential (ECAP), a synchronous response from electri...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.18052

    authors: Nassiri AM,Yawn RJ,Gifford RH,Haynes DS,Roberts JB,Gilbane MS,Murfee J,Bennett ML

    更新日期:2019-11-01 00:00:00

  • Evaluation of the efficacy of a multimemory hearing aid.

    abstract::Although multimemory hearing aids have theoretical advantages over conventional "single memory" hearing aids, research and clinical data are not available to support their efficacy. The present study reports on the usefulness of a commercially available multimemory hearing aid in daily listening situations. Nineteen e...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Kuk FK

    更新日期:1992-09-01 00:00:00

  • Effects of stimulus rate and gender on the auditory middle latency response.

    abstract::The effects of stimulus rate and gender on the auditory middle latency response (AMLR) waveforms were examined in 20 young adult male and female subjects. Four different repetition rates were presented to subjects (1.1/sec, 4.1/sec, 7.7/ sec, and 11.3/sec). Stimulus repetition rate had a significant effect on Pa laten...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Tucker DA,Dietrich S,Harris S,Pelletier S

    更新日期:2002-03-01 00:00:00

  • High resolution recording of late cortical surface potentials N1 and gamma band response (GBR).

    abstract::The present investigation was conducted to help determine whether source activity of the direct recorded N1 response differed from that of the gamma band response (GBR). Auditory evoked cortical potential data from two patients with intractable epilepsy undergoing prolonged video EEG monitoring after implantation of s...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Jacobson GP,Henderson J,Smith BJ,Elisevich KV

    更新日期:1998-04-01 00:00:00

  • The effect of digital phase cancellation feedback reduction systems on amplified sound quality.

    abstract::The effect of feedback reduction (FBR) systems on sound quality recorded from two commercially available hearing aids was evaluated using paired comparison judgments by 16 participants with mild to severe sloping hearing loss. These comparisons were made with the FBR systems on and off without audible feedback and whi...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 临床试验,杂志文章

    doi:10.3766/jaaa.18.5.5

    authors: Johnson EE,Ricketts TA,Hornsby BW

    更新日期:2007-05-01 00:00:00

  • Psychoacoustic measures of tinnitus.

    abstract::This report reviews research from the 1930s to the present that has extended our understanding by investigating the characteristics of tinnitus that can be studied using psychoacoustic techniques. Studies of tinnitus masking and residual inhibition began in the 1970s, leading to the therapeutic use of tinnitus masking...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,评审

    doi:

    authors: Henry JA,Meikle MB

    更新日期:2000-03-01 00:00:00

  • Quantification of Head Acceleration during Vestibular Rehabilitation Exercises.

    abstract:PURPOSE:Vestibular rehabilitation exercises have been proven to reduce symptoms and diminish the risk of falls in those with dizziness and balance impairments. The first purpose of this study is to investigate a new method of measuring head movements during habituation vestibular rehabilitation exercises. The second is...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.16026

    authors: Hogan AE,Spindel JH,Gray LC

    更新日期:2018-01-01 00:00:00

  • The influence of caffeine on calorics and cervical vestibular evoked myogenic potentials (cVEMPs).

    abstract:BACKGROUND:Prior to undergoing vestibular function testing, it is not uncommon for clinicians to request that patients abstain from caffeine 24 hr prior to the administration of the tests. However, there is little evidence that caffeine affects vestibular function. PURPOSE:To evaluate whether the results from two test...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.25.3.5

    authors: McNerney K,Coad ML,Burkard R

    更新日期:2014-03-01 00:00:00

  • Effects of pre-existing hearing loss and gender on proposed ANSI S12.13 outcomes for characterizing hearing conservation program effectiveness: preliminary investigation.

    abstract::Draft American National Standard "Evaluating the Effectiveness of Hearing Conservation Programs" identifies potentially important links between audiometric threshold variability outcomes and occupational hearing conservation program (HCP) practices. Unacceptable threshold variability in annual audiograms may identify ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Amos NE,Simpson TH

    更新日期:1995-11-01 00:00:00

  • Behavioral and electrophysiologic binaural processing in persons with symmetric hearing loss.

    abstract:BACKGROUND:Binaural hearing improves our ability to understand speech and to localize sounds. Hearing loss can interfere with binaural cues, and despite the success of amplification, ∼25% of people with bilateral hearing loss fit with two hearing aids choose to wear only one (e.g., Brooks and Bulmer, 1981). One explana...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.22.3.6

    authors: Leigh-Paffenroth ED,Roup CM,Noe CM

    更新日期:2011-03-01 00:00:00

  • Acoustic and hearing aid circuit variables affecting the tolerability of aided impulsive-type sounds.

    abstract::The tolerability of aided impulsive-type stimuli was investigated in a group of 13 hearing-impaired listeners. Two linear circuits (one with a class A and one with a class D output stage) and one adaptive frequency response (AFR) circuit (with a class D output stage) were investigated. In a three-way paired-comparison...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Fortune TW,Preves DA

    更新日期:1994-09-01 00:00:00

  • Rate, frequency, and intensity effects on early auditory evoked potentials and binaural interaction component in humans.

    abstract::The binaural interaction component (BIC) of the auditory brainstem response (ABR) and BIC of the frequency-following response (FFR) to tonal stimuli were studied in normal-hearing adults. The ABR and BIC latencies from all subjects were consistently shorter to the click-like sound than to the 2.0 kHz tone burst. Incre...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Parthasarathy TK,Moushegian G

    更新日期:1993-07-01 00:00:00

  • Central auditory processing disorders and reduced motivation: three case studies.

    abstract::The central auditory test results for three normal-hearing children who were initially diagnosed as having a central auditory processing disorder and learning disability are presented. They were referred to the authors for second-opinion consultations. Central auditory processing retesting was performed by the authors...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Silman S,Silverman CA,Emmer MB

    更新日期:2000-02-01 00:00:00

  • Multiple-ASSR thresholds in infants and young children with hearing loss.

    abstract:BACKGROUND:The multiple auditory steady-state response (multiple ASSR) is a promising technique for determining thresholds for infants and children. However, there are few data for infants and young children with hearing loss where multiple-ASSR thresholds have been compared to frequency-specific gold standard (i.e., b...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.21.8.5

    authors: Van Maanen A,Stapells DR

    更新日期:2010-09-01 00:00:00

  • Evaluation and treatment of severe hyperacusis.

    abstract::A 52-year-old male was evaluated by the authors after initially reporting fullness in his left ear while traveling on an airplane. A unique feature of the patient's complaint was the development of severe bilateral hyperacusis (loudness discomfort levels of between 20-34 dB HL) in spite of the fact that the hearing lo...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Valente M,Goebel J,Duddy D,Sinks B,Peterein J

    更新日期:2000-06-01 00:00:00

  • Evaluation of a BICROS System with a Directional Microphone in the Receiver and Transmitter.

    abstract:BACKGROUND:The bilateral contralateral routing of signals (BICROS) system has provided limited benefit for speech recognition in noise for patients with asymmetric sensorineural hearing loss, even when an automatic adaptive multichannel directional microphone (DM) is in the receiver (Rx) and an omnidirectional micropho...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,随机对照试验

    doi:10.3766/jaaa.15031

    authors: Valente M,Oeding K

    更新日期:2015-11-01 00:00:00

  • Performance of musicians and nonmusicians on dichotic chords, dichotic CVs, and dichotic digits.

    abstract::Perception of dichotic chords (free recall and directed recall), nonsense syllables (CVs), and three-pair digits was assessed on 24 musicians and 24 nonmusicians. On the dichotic-CV and dichotic-digit free-recall tasks, there was a significant right-ear advantage, but there were no group differences. With the dichotic...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.14.10.2

    authors: Nelson MD,Wilson RH,Kornhass S

    更新日期:2003-12-01 00:00:00

  • Hearing Aid Benefit in Patients with Mild Sensorineural Hearing Loss: A Systematic Review.

    abstract:BACKGROUND:Untreated sensorineural hearing loss (SNHL) is associated with chronic health-care conditions, isolation, loneliness, and reduced quality of life. Although hearing aids can minimize the negative effects of SNHL, only about one in five persons with SNHL seeks help for communication problems. Many persons wait...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,meta分析

    doi:10.3766/jaaa.14076

    authors: Johnson CE,Danhauer JL,Ellis BB,Jilla AM

    更新日期:2016-04-01 00:00:00

  • A Revision Surgery for Cochlear Implantation in a Case of Incomplete Partition Type I.

    abstract:BACKGROUND:Patients with cochlear malformations were long considered poor candidates for cochlear implantation (CI), and surgical approaches different than the standard facial recess approach were used to access the inner ear. There is no previous long-term follow-up of a patient with significantly malformed inner ear ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.15107

    authors: Rizk HG,Hagood F,Holcomb MA,Meyer TA

    更新日期:2016-11-01 00:00:00