Abstract:
BACKGROUND:Prior to undergoing vestibular function testing, it is not uncommon for clinicians to request that patients abstain from caffeine 24 hr prior to the administration of the tests. However, there is little evidence that caffeine affects vestibular function. PURPOSE:To evaluate whether the results from two tests commonly used in a clinical setting to assess vestibular function (i.e., calorics and the cervical vestibular evoked myogenic potential [cVEMP]) are affected by caffeine. RESEARCH DESIGN:Subjects were tested with and without consuming a moderate amount of caffeine prior to undergoing calorics and cVEMPs. STUDY SAMPLE:Thirty young healthy controls (mean = 23.28 yr; females = 21). Subjects were excluded if they reported any history of vestibular/balance impairment. DATA COLLECTION AND ANALYSIS:The Variotherm Plus Caloric Irrigator was used to administer the water, while the I-Portal VNG software was used to collect and analyze subjects' eye movements. The TECA Evoked Potential System was used for the cVEMP stimulus presentation as well as for the data collection. During cVEMP collection, subjects were asked to monitor their sternocleidomastoid muscle contraction with a Delsys EMG monitor. IBM SPSS Statistics 20 was used to statistically analyze the results via paired t-tests. RESULTS:Analysis of the data revealed that ingestion of caffeine did not significantly influence the results of either test of vestibular function. CONCLUSIONS:The results revealed that a moderate amount of caffeine does not have a clinically significant effect on the results from caloric and cVEMP tests in young healthy adults. Future research is necessary to determine whether similar results would be obtained from individuals with a vestibular impairment, as well as older adults.
journal_name
J Am Acad Audioljournal_title
Journal of the American Academy of Audiologyauthors
McNerney K,Coad ML,Burkard Rdoi
10.3766/jaaa.25.3.5subject
Has Abstractpub_date
2014-03-01 00:00:00pages
261-7issue
3eissn
1050-0545issn
2157-3107journal_volume
25pub_type
杂志文章abstract:PURPOSE:To investigate the test-retest reliability of real-ear aided response (REAR) measures in open and closed hearing aid fittings in children using appropriate probe-microphone calibration techniques (stored equalization for open fittings and concurrent equalization for closed fittings). RESEARCH DESIGN:Probe-micr...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.24.7.11
更新日期:2013-07-01 00:00:00
abstract::The tolerability of aided impulsive-type stimuli was investigated in a group of 13 hearing-impaired listeners. Two linear circuits (one with a class A and one with a class D output stage) and one adaptive frequency response (AFR) circuit (with a class D output stage) were investigated. In a three-way paired-comparison...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1994-09-01 00:00:00
abstract::The Hearing-in-Noise Test (HINT) is able to measure the benefit to speech intelligibility in noise conferred when the noise masker is displaced 90 degrees in eccentricity from a speech source located at zero degrees azimuth. Both psychoacoustic and neurophysiological data suggest that the perceptual benefit of the 90-...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.14.9.7
更新日期:2003-11-01 00:00:00
abstract:BACKGROUND:Although cochlear implant patients are achieving increasingly higher levels of performance, speech perception in noise continues to be problematic. The newest generations of implant speech processors are equipped with preprocessing and/or external accessories that are purported to improve listening in noise....
journal_title:Journal of the American Academy of Audiology
pub_type: 临床试验,杂志文章
doi:10.3766/jaaa.21.7.3
更新日期:2010-07-01 00:00:00
abstract::Twelve children, ranging in age from 8.9 to 12.4 years, with histories of severe otitis media with effusion (OME) before age 3, were compared to age-matched cohorts in their ability to discriminate the frequency of tone pulses of 20-, 50-, and 200-msec duration. An adaptive procedure was used in combination with a two...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1997-04-01 00:00:00
abstract::Perception of dichotic chords (free recall and directed recall), nonsense syllables (CVs), and three-pair digits was assessed on 24 musicians and 24 nonmusicians. On the dichotic-CV and dichotic-digit free-recall tasks, there was a significant right-ear advantage, but there were no group differences. With the dichotic...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.14.10.2
更新日期:2003-12-01 00:00:00
abstract:BACKGROUND:Production effect (PE) is a memory phenomenon referring to better memory for produced (vocalized) than for non-produced (silently read) items. Reading aloud was found to improve verbal memory for normal-hearing individuals, as well as for cochlear implant users, studying visually and aurally presented materi...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.17030
更新日期:2018-11-01 00:00:00
abstract:BACKGROUND:Albeit limited, research suggests that students pursuing careers in health care receive limited training on the provision of services for people with hearing loss. As the incidence of hearing loss continues to increase among Americans, it is critical that medical professionals understand how hearing loss amo...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.17071
更新日期:2019-04-01 00:00:00
abstract::A speech test evaluation and presentation system is described. The test presentation subsystem has the flexibility and speed of live-voice testing while using recorded test materials. The speech test evaluation subsystem compares an individual subject's test performance on a monosyllabic word test with that of an aver...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1999-07-01 00:00:00
abstract::Recent advances in endoscopic optics and miniature video camera technology have made video otoscopy (VO) accessible to audiologists in a practical way. Seven categories of VO applications are presented with clinical examples: (1) general examination of the earcanal and tympanic membrane, (2) physician communication/te...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1997-12-01 00:00:00
abstract:BACKGROUND:Tinnitus can be defined as the perception of an auditory sensation, perceivable without the presence of an external sound. PURPOSE:The aim of this article is to systematically review the peer-reviewed literature on treatment approaches for tinnitus based on cognitive-behavioral therapy (CBT) and to provide ...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章,评审
doi:10.3766/jaaa.25.1.4
更新日期:2014-01-01 00:00:00
abstract:BACKGROUND:The middle latency response (MLR) first came to light as an auditory evoked potential in 1958. Since then, it has aroused substantial interest and investigation by clinicians and researchers alike. In recent history, its use and popularity have dwindled in tandem with various other auditory evoked potentials...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.16141
更新日期:2018-10-01 00:00:00
abstract:BACKGROUND:Evaluation of hearing-device signal-processing features is performed for research and development purposes, but also in clinical settings. Most people agree that the benefit experienced in a hearing-device user's daily life is most important, but laboratory tests are popular since they can be performed unifo...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.15105
更新日期:2016-07-01 00:00:00
abstract:BACKGROUND:There is broad consensus that screening and diagnosis of permanent hearing loss in children must be embedded within a comprehensive, evidence-based, family-centered intervention program. Clinical practice guidelines (CPGs) for pediatric hearing assessment and hearing aid verification aim to reduce variabilit...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.15064
更新日期:2016-03-01 00:00:00
abstract:PURPOSE:The purpose was to assess the proportion of patients seeking help for tinnitus and/or hyperacusis who have severe hyperacusis and to examine factors associated with severe hyperacusis. RESEARCH DESIGN:This was a retrospective cross-sectional study based on 362 consecutive patients who attended a National Healt...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.17015
更新日期:2018-07-01 00:00:00
abstract::This paper discusses trends and issues in selecting amplification for new, mainly nonlinear, types of hearing aids. Some-concerns are that nonvalidated prescription formulae may proliferate; that, through concentration on loudness normalization, alternative rationales are not being evaluated; and that most new fitting...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章,评审
doi:
更新日期:1996-12-01 00:00:00
abstract:BACKGROUND:The Auditec of St. Louis and the Department of Veterans Affairs (VA) recorded versions of the Northwestern University Auditory Test No. 6 (NU-6) are in common usage. Data on young adults with normal hearing for pure tones (YNH) demonstrate equal recognition performances on the two versions when the VA versio...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章,随机对照试验
doi:10.3766/jaaa.17135
更新日期:2019-05-01 00:00:00
abstract::This is the second in a series of two papers on masking. The objective of these papers is to develop a masking protocol that provides valid measures of threshold and is, in general, faster than the plateau method. In the first paper, a masking method was presented that can replace the traditional plateau method in mos...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.15.1.5
更新日期:2004-01-01 00:00:00
abstract:PURPOSE:To present a case study in order to alert clinicians to the possibility of occurrence of intermodulation distortion during otoacoustic emissions testing that arises from the cavity formed by the external auditory meatus and tympanic membrane rather than from the inner ear, compromising the reliability and valid...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.20.5.3
更新日期:2009-05-01 00:00:00
abstract::Crystal Device Integrity Testing System (CITS), the first commercially available testing system of its type, allows rapid assessment of cochlear implant function by measuring averaged electrode voltages-the scalp-recorded fields generated by electrode currents. We describe our experience performing routine integrity t...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.17.10.4
更新日期:2006-11-01 00:00:00
abstract::Balance Function test data alone cannot capture the reaction that a patient has to balance system disease. The present investigation examined the relations among components of the balance function examination (electronystagmography, rotational testing, and platform posturography) and self-perceived dizziness handicap,...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1991-10-01 00:00:00
abstract::This report reviews research from the 1930s to the present that has extended our understanding by investigating the characteristics of tinnitus that can be studied using psychoacoustic techniques. Studies of tinnitus masking and residual inhibition began in the 1970s, leading to the therapeutic use of tinnitus masking...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章,评审
doi:
更新日期:2000-03-01 00:00:00
abstract::We describe the rationale for the development of a psychophysical procedure that allows individual listeners to adjust the frequency-gain characteristic of a programmable hearing aid on a unidimensional scale, based on a target-gain reference value. The listener's task is to adjust the frequency response and select th...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1992-03-01 00:00:00
abstract::There have been scattered accounts reported in the oncology literature of progressive hearing loss following the conclusion of chemotherapy. In this case study, we report the audiologic findings of such a case. These data underscore the need for post-therapy monitoring in cases where threshold shifts are discovered du...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1993-11-01 00:00:00
abstract:BACKGROUND: Ecological momentary assessment (EMA) is a methodology involving repeated surveys to collect in-situ self-reports that describe respondents' current or recent experiences. Audiology literature comparing in-situ and retrospective self-reports is scarce. PURPOSE: To compare the sensitivity of in-situ and ret...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.1055/s-0040-1719133
更新日期:2020-12-15 00:00:00
abstract:BACKGROUND:Complex working memory (WM) span tasks have been shown to predict speech-in-noise (SIN) recognition. Studies of complex WM span tasks suggest that, rather than indexing a single cognitive process, performance on such tasks may be governed by separate cognitive subprocesses embedded within WM. Previous resear...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.25.10.6
更新日期:2014-11-01 00:00:00
abstract::Compact disc versions of the frequency (pitch) and duration pattern tests are reported. Results are similar to previous reports on these tests using taped materials. Mean performance of normal-hearing young adults for both pattern perception tests was approximately 90 percent. There was no effect of the two presentati...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1994-07-01 00:00:00
abstract::The purpose of this study was to develop a test to assess the ability of persons with cochlear implants (CIs) to interpret musical signals. Up to this time, the main direction in outcomes studies of cochlear implantation has been in relation to speech recognition abilities. With improvement in CI hardware and processi...
journal_title:Journal of the American Academy of Audiology
pub_type: 临床试验,杂志文章
doi:10.3766/jaaa.19.1.6
更新日期:2008-01-01 00:00:00
abstract::Auditory training has long been advocated to enhance communication but has never been time or cost-effective. This article describes the concepts underlying the development of a home-based, interactive adaptive computer program designed to engage the adult hearing-impaired listener in the hearing-aid-fitting process, ...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章,随机对照试验
doi:10.3766/jaaa.17.8.2
更新日期:2006-09-01 00:00:00
abstract::The Three-Clinic Hearing Aid Selection Profile (HASP) was developed to assess a patient's beliefs about a number of basic considerations felt to be critical to the hearing aid selection (HAS) process. These characteristics are felt to be key to the acceptance of amplification and include motivation, expectations, cost...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:2001-03-01 00:00:00