Abstract:
:There have been scattered accounts reported in the oncology literature of progressive hearing loss following the conclusion of chemotherapy. In this case study, we report the audiologic findings of such a case. These data underscore the need for post-therapy monitoring in cases where threshold shifts are discovered during the course of drug administration.
journal_name
J Am Acad Audioljournal_title
Journal of the American Academy of Audiologyauthors
Sweetow RW,Will TIsubject
Has Abstractpub_date
1993-11-01 00:00:00pages
360-3issue
6eissn
1050-0545issn
2157-3107journal_volume
4pub_type
杂志文章abstract::Perception of dichotic chords (free recall and directed recall), nonsense syllables (CVs), and three-pair digits was assessed on 24 musicians and 24 nonmusicians. On the dichotic-CV and dichotic-digit free-recall tasks, there was a significant right-ear advantage, but there were no group differences. With the dichotic...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.14.10.2
更新日期:2003-12-01 00:00:00
abstract:BACKGROUND:Untreated sensorineural hearing loss (SNHL) has been linked to depression, social isolation, anxiety, and a reduction in health-related quality of life (QoL), and is independently associated with cognitive decline. Only one in five persons with SNHL pursues amplification; 76-97% of those having hearing aids ...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.18036
更新日期:2020-02-01 00:00:00
abstract:BACKGROUND:In Sweden, there is a lack of evidence-based rehabilitation programs for hearing loss. The Active Communication Education program (ACE) has successfully been used in Australia and was translated and evaluated in a Swedish pilot study. The pilot study included 23 participants (age 87 yr). No statistically sig...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.25.9.7
更新日期:2014-10-01 00:00:00
abstract:BACKGROUND:Pitch pattern sequence (PPS) and duration pattern sequence (DPS) tests are frequently used in the assessment of auditory processing disorder. Current recommendations suggest alternate, interchangeable modes for responding to stimuli. PURPOSE:The objective of the study is to evaluate the influence of respons...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.16132
更新日期:2019-01-01 00:00:00
abstract::The aim of this research was to study the effects of several stimulus parameters on adaptation characteristics of the auditory brainstem response (ABR). Recordings were obtained from normal hearing adults to separate trains of 5 rarefaction and 5 condensation clicks with interclick intervals of 10 msec and intertrain ...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1992-07-01 00:00:00
abstract:BACKGROUND:Evidence suggests that hearing-aid users have difficulties with own-voice level control, most likely because their auditory feedback is affected by hearing-aid amplification. PURPOSE:The purpose of this study was to investigate how changes to auditory feedback affect the voice level of hearing-aid users. R...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.20.8.5
更新日期:2009-09-01 00:00:00
abstract::Performance-intensity functions for PB word lists were run on 19 normal-hearing subjects and 15 subjects with sensorineural hearing losses. Comparisons were made between standard supra-aural earphones (TDH-49P) and insert phones (ER-3A). Results showed that, at least for the higher sensation levels where word recognit...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1991-01-01 00:00:00
abstract:BACKGROUND:The middle latency response (MLR) first came to light as an auditory evoked potential in 1958. Since then, it has aroused substantial interest and investigation by clinicians and researchers alike. In recent history, its use and popularity have dwindled in tandem with various other auditory evoked potentials...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.16141
更新日期:2018-10-01 00:00:00
abstract::The histories of two pediatric patients who received cochlear implants with subsequent partial recovery of hearing in the nonimplanted ear are reviewed. One child had a sudden bilateral hearing loss, presumably secondary to autoimmune ear disease. The other child had a bilateral progressive hearing loss diagnosed as l...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.16.10.2
更新日期:2005-11-01 00:00:00
abstract:BACKGROUND:Various methods have been used to measure temporal-fine-structure (TFS) sensitivity in hearing-impaired (HI) listeners. A new method called TFS-adaptive frequency (TFS-AF) test, tracks the highest frequency up to which a person can detect a given interaural phase difference (IPD) in bursts of pure tones. So ...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.18068
更新日期:2020-02-01 00:00:00
abstract:PURPOSE:To investigate the test-retest reliability of real-ear aided response (REAR) measures in open and closed hearing aid fittings in children using appropriate probe-microphone calibration techniques (stored equalization for open fittings and concurrent equalization for closed fittings). RESEARCH DESIGN:Probe-micr...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.24.7.11
更新日期:2013-07-01 00:00:00
abstract:BACKGROUND:The acoustic stapedial reflex (ASR) test provides useful information about the function of the auditory system. While it is frequently used with adults and children in a clinical setting, its use with young infants is limited. Presently, there are few data for neonates and inadequate research into the test-r...
journal_title:Journal of the American Academy of Audiology
pub_type: 临床试验,杂志文章
doi:10.3766/jaaa.23.1.5
更新日期:2012-01-01 00:00:00
abstract:BACKGROUND:Prescriptive methods have been at the core of modern hearing aid fittings for the past several decades. Every decade or so, there have been revisions to existing methods and/or the emergence of new methods that become widely used. In 2001 Byrne et al provided a comparison of insertion gain for generic prescr...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.22.7.5
更新日期:2011-07-01 00:00:00
abstract:PURPOSE:There will likely be several different tinnitus treatments necessary, and it is important to understand patient preferences and factors that might contribute to treatment acceptability. This study explores the acceptability of a wide range of different tinnitus treatments, from noninvasive wearable devices to s...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.23.2.6
更新日期:2012-02-01 00:00:00
abstract:BACKGROUND:The compound action potential (CAP) has been suggested in the literature as an alternative to otoacoustic emissions for evaluating the efferent auditory system. However, very few studies have examined efferent influence on auditory nerve potentials in humans. PURPOSE:This study examines the effects of prese...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.15002
更新日期:2016-02-01 00:00:00
abstract:BACKGROUND:Production effect (PE) is a memory phenomenon referring to better memory for produced (vocalized) than for non-produced (silently read) items. Reading aloud was found to improve verbal memory for normal-hearing individuals, as well as for cochlear implant users, studying visually and aurally presented materi...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.17030
更新日期:2018-11-01 00:00:00
abstract:BACKGROUND:The visual speech signal can provide sufficient information to support successful communication. However, individual differences in the ability to appreciate that information are large, and relatively little is known about their sources. PURPOSE:Here a body of research is reviewed regarding the development ...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章,评审
doi:10.3766/jaaa.21.3.4
更新日期:2010-03-01 00:00:00
abstract::Compact disc versions of the frequency (pitch) and duration pattern tests are reported. Results are similar to previous reports on these tests using taped materials. Mean performance of normal-hearing young adults for both pattern perception tests was approximately 90 percent. There was no effect of the two presentati...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1994-07-01 00:00:00
abstract:BACKGROUND:The relation between the auditory steady-state response (ASSR) and behavioral audiometric thresholds requires further clarification in the case of adults with auditory neuropathy/auditory dys-synchrony (AN/AD). PURPOSE:The aim of this study was to compare pure-tone audiometric threshold (PTAT) and ASSR in a...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.20.10.4
更新日期:2009-11-01 00:00:00
abstract:BACKGROUND:Motivational interviewing (MI) has been used in consultation settings to motivate hearing aid users to increase hearing aid usage. However, the effect of MI on those who use their hearing aids only rarely or not at all has not been explored. PURPOSE:The aims of this pilot study were to evaluate the effect o...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.16184
更新日期:2018-09-01 00:00:00
abstract::This study describes audiologic methodology and results for evaluating potential ototoxicity in a phase I clinical trial of a new glycopeptide. This study was conducted under good clinical practices, which are regulated by the US Food and Drug Administration (FDA) (21 Code of Federal Regulations), and input from the F...
journal_title:Journal of the American Academy of Audiology
pub_type: 临床试验,杂志文章,随机对照试验
doi:
更新日期:2003-04-01 00:00:00
abstract::In studies to date, the effectiveness of the directional microphone has been investigated independently of the signal processing scheme used in the hearing aid. In addition, the number and placement of the background noise speakers can create an advantage for a particular polar pattern (i.e., cardioid, supercardioid, ...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:2001-11-01 00:00:00
abstract::In recent years, we have observed causes of congenital or early onset hearing disorders that had not been recognized or known to exist before. These include drugs passed to an as-yet unborn child. Principal among them is alcohol, but others, such as cocaine, are now also occupying our attention. This article reviews t...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章,评审
doi:
更新日期:1995-09-01 00:00:00
abstract:BACKGROUND:Complex working memory (WM) span tasks have been shown to predict speech-in-noise (SIN) recognition. Studies of complex WM span tasks suggest that, rather than indexing a single cognitive process, performance on such tasks may be governed by separate cognitive subprocesses embedded within WM. Previous resear...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.25.10.6
更新日期:2014-11-01 00:00:00
abstract:BACKGROUND:The acceptable noise level (ANL) serves to accurately predict the listener's likelihood of success with amplification. It has been proposed as a pre-hearing aid fitting protocol for hearing aid selection and counseling purposes. The ANL is a subjective measure of the listener's ability to accept background n...
journal_title:Journal of the American Academy of Audiology
pub_type: 临床试验,杂志文章
doi:10.3766/jaaa.23.7.5
更新日期:2012-07-01 00:00:00
abstract:BACKGROUND:Cochlear implant (CI) recipients experience difficulty understanding speech in noise. Remote-microphone technology that improves the signal-to-noise ratio is recognized as an effective means to improve speech recognition in noise; however, there are no published studies evaluating the potential benefits of a...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.15005
更新日期:2015-06-01 00:00:00
abstract:BACKGROUND: Both the Roger remote microphone and on-ear, adaptive beamforming technologies (e.g., Phonak UltraZoom) have been shown to improve speech understanding in noise for cochlear implant (CI) listeners when tested in audio-only (A-only) test environments. PURPOSE: Our aim was to determine if adult and pediatric...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.1055/s-0040-1718893
更新日期:2020-12-09 00:00:00
abstract:BACKGROUND/PURPOSE:The acceptable noise level (ANL) test is the only test that is known to predict success with hearing aids with a high degree of accuracy. A person's ANL is the maximal amount of background noise that he or she is "willing to put up with" while listening to running speech. It is defined as the speech ...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.25.6.10
更新日期:2014-06-01 00:00:00
abstract::A 52-year-old male was evaluated by the authors after initially reporting fullness in his left ear while traveling on an airplane. A unique feature of the patient's complaint was the development of severe bilateral hyperacusis (loudness discomfort levels of between 20-34 dB HL) in spite of the fact that the hearing lo...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:2000-06-01 00:00:00
abstract:BACKGROUND:Wideband acoustic immittance (WAI) measures provide information about middle-ear function across the traditional audiometric frequency range from 0.25 to 8.0 kHz. Recent studies have found that WAI is effective in predicting the presence of conductive hearing loss (CHL). It is not known whether WAI can accur...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.25.5.5
更新日期:2014-05-01 00:00:00