Abstract:
BACKGROUND:Untreated sensorineural hearing loss (SNHL) has been linked to depression, social isolation, anxiety, and a reduction in health-related quality of life (QoL), and is independently associated with cognitive decline. Only one in five persons with SNHL pursues amplification; 76-97% of those having hearing aids report regular or occasional use. Although hearing aid use during all waking hours is advocated for children, recommendations for adults are not as clear. Treatment outcomes, including benefit, satisfaction, and self-efficacy with hearing aids, may be predictors of self-reported hearing aid use, which is useful in clinical practice. PURPOSE:The aim of this study was to determine average hours of self-reported daily hearing aid use by adults and if treatment outcome measures of benefit, satisfaction, and self-efficacy with hearing aids can predict self-reported daily hearing aid use in adults. RESEARCH DESIGN:The present study was a prospective cross-sectional survey with retrospective chart review. STUDY SAMPLE:The study sample consisted of 152 experienced adult advanced digital technology (ADT) hearing aid users between 18 and 90 years of age who were patients in a two-office private practice in California. DATA COLLECTION AND ANALYSIS:A postal survey was sent to 500 experienced adult ADT hearing aid users. Participants completed the Visual Analog Scale for Daily Use of Hearing Aids (VASuse) and validated measures of (1) self-efficacy, (2) satisfaction, and (3) benefit. Retrospective data were collected for all respondents via chart review. Multivariable linear regression was used to explore relationships between treatment outcomes and hearing aid use. RESULTS:Experienced hearing aid users wore their hearing aids an average of 12.0 h/day. Daily hearing aid use was significantly associated with residual participation restriction (RPR) on the International Outcome Inventory for Hearing Aids (IOI-HA) item 5 (p = 0.02). The VASuse was significantly associated with the IOI-HA factor 1, "Me and My Hearing Aids" (p = 0.03), an aggregate measure of satisfaction, benefit, and QoL. CONCLUSIONS:Participants reported wearing their hearing aids an average of 12.0 h/day. Self-reported daily hearing aid use was associated with a combination of satisfaction, benefit, and increased QoL, and with RPR. The interconnectedness of satisfaction, benefit, and QoL positively affected hearing aid use, and greater levels of RPR seemed to discourage hearing aid use. If hearing aid owners are inconsistent or nonusers, then counseling and outcome measures should be used in the domains of satisfaction, benefit, and QoL. Future research should involve additional ADT hearing aid users with different experience levels across various study sites.
journal_name
J Am Acad Audioljournal_title
Journal of the American Academy of Audiologyauthors
Jilla AM,Johnson CE,Danhauer JL,Anderson M,Smith JN,Sullivan JC,Sanchez KRdoi
10.3766/jaaa.18036subject
Has Abstractpub_date
2020-02-01 00:00:00pages
87-95issue
2eissn
1050-0545issn
2157-3107journal_volume
31pub_type
杂志文章abstract:BACKGROUND:Although audiologists have been using support personnel for over 45 yr, controversy and variability continue with respect to the entry-level education, training methods, and scope of practice. PURPOSE:As part of a larger clinical practices survey, this report focuses on use of audiology assistants (AAs) for...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章,多中心研究
doi:10.3766/jaaa.17004
更新日期:2018-05-01 00:00:00
abstract::Human auditory steady-state responses (ASSRs) were recorded using stimulus rates of 78-95 Hz in normal young subjects, in elderly subjects with relatively normal hearing, and in elderly subjects with sensorineural hearing impairment. Amplitude-intensity functions calculated relative to actual sensory thresholds (sensa...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.16.3.3
更新日期:2005-03-01 00:00:00
abstract::Auditory brainstem responses were measured in response to 1000-Hz tone bursts from 115 patients with sensorineural hearing loss, presumably of cochlear origin. Mean wave V latencies and variability were comparable to those observed in normal hearing subjects for similar stimuli. The range of interaural differences in ...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1992-05-01 00:00:00
abstract:BACKGROUND:Wideband reflectance (WBR) provides important information about middle ear function and can explain variations in how the middle ear receives, absorbs, and transmits sound energy across a wide range of frequencies. However, as of yet, few normative studies have been published to guide clinicians in the pract...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.19.5.4
更新日期:2008-05-01 00:00:00
abstract::We describe the rationale for the development of a psychophysical procedure that allows individual listeners to adjust the frequency-gain characteristic of a programmable hearing aid on a unidimensional scale, based on a target-gain reference value. The listener's task is to adjust the frequency response and select th...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1992-03-01 00:00:00
abstract:BACKGROUND:Although cochlear implant patients are achieving increasingly higher levels of performance, speech perception in noise continues to be problematic. The newest generations of implant speech processors are equipped with preprocessing and/or external accessories that are purported to improve listening in noise....
journal_title:Journal of the American Academy of Audiology
pub_type: 临床试验,杂志文章
doi:10.3766/jaaa.21.7.3
更新日期:2010-07-01 00:00:00
abstract::A 52-year-old male was evaluated by the authors after initially reporting fullness in his left ear while traveling on an airplane. A unique feature of the patient's complaint was the development of severe bilateral hyperacusis (loudness discomfort levels of between 20-34 dB HL) in spite of the fact that the hearing lo...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:2000-06-01 00:00:00
abstract:BACKGROUND:Degraded hearing in older adults has been associated with reduced postural control and higher risk of falls. Both hearing loss (HL) and falls have dramatic effects on older persons' quality of life (QoL). A large body of research explored the comorbidity between the two domains. PURPOSE:The aim of the curre...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章,评审
doi:10.3766/jaaa.16044
更新日期:2017-06-01 00:00:00
abstract:BACKGROUND:Before advanced noise-management features can be recommended for use in children with hearing loss, evidence regarding their ability to use these features to optimize speech perception is necessary. PURPOSE:The purpose of this study was to examine the relation between children's preference for, and performa...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.24.9.7
更新日期:2013-10-01 00:00:00
abstract:BACKGROUND:Bilingual (BL) listeners' difficulties in adverse noise conditions are exacerbated when perceiving their second language (L2) relative to their first language (L1). Perception of L2 is also significantly poorer by BL listeners compared to native monolingual (ML) listeners. PURPOSE:The purpose of the study w...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.21.4.3
更新日期:2010-04-01 00:00:00
abstract:BACKGROUND:Complex working memory (WM) span tasks have been shown to predict speech-in-noise (SIN) recognition. Studies of complex WM span tasks suggest that, rather than indexing a single cognitive process, performance on such tasks may be governed by separate cognitive subprocesses embedded within WM. Previous resear...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.25.10.6
更新日期:2014-11-01 00:00:00
abstract:BACKGROUND:There is broad consensus that screening and diagnosis of permanent hearing loss in children must be embedded within a comprehensive, evidence-based, family-centered intervention program. Clinical practice guidelines (CPGs) for pediatric hearing assessment and hearing aid verification aim to reduce variabilit...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.15064
更新日期:2016-03-01 00:00:00
abstract::The acoustic otoscope, originally called the acoustic reflectometer, was developed and produced by John and David Teele in the early 1980s. Since initial production, two different instrument versions have been developed by two separate companies. During the period of time in which the acoustic otoscope has been in pro...
journal_title:Journal of the American Academy of Audiology
pub_type: 历史文章,杂志文章
doi:
更新日期:1998-02-01 00:00:00
abstract:BACKGROUND:We recently described a research study in which age-related changes in interaural asymmetry were elicited using the N400 of the auditory event-related potentials (AERP) (Davis et al, 2013). The N400 was the primary focus due to its sensitivity to various aspects of semantic processing (Kutas and Hillyard, 19...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.25.2.8
更新日期:2014-02-01 00:00:00
abstract::We examined the ability of 40 young children (aged five to eight) to understand speech (monosyllables, spondees, trochees, and trisyllables) when listening in a background of real-life classroom noise. All children had some difficulty understanding speech when the noise was at levels found in many classrooms (i.e., 65...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.15.7.5
更新日期:2004-07-01 00:00:00
abstract::Loudness discomfort levels (LDLs) were measured in dB HL and SPL at discrete frequencies between 500 to 4000 Hz on 31 hearing-impaired ears using TDH-50P and ER-3A earphones. The results revealed no significant differences in the measured sound pressure level (SPL) between the two earphones at all test frequencies. Ho...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1997-02-01 00:00:00
abstract::Evidence-based practice (EBP) has been widely embraced in many health-care fields as a way of maintaining currency of knowledge and state-of-the-art treatment recommendations in an age of information abundance and rapid scientific progress. Although the principles of EBP are slowly entering the specialties of communic...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章,评审
doi:10.3766/jaaa.16.7.3
更新日期:2005-07-01 00:00:00
abstract:BACKGROUND: Both the Roger remote microphone and on-ear, adaptive beamforming technologies (e.g., Phonak UltraZoom) have been shown to improve speech understanding in noise for cochlear implant (CI) listeners when tested in audio-only (A-only) test environments. PURPOSE: Our aim was to determine if adult and pediatric...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.1055/s-0040-1718893
更新日期:2020-12-09 00:00:00
abstract:BACKGROUND:A number of published studies have demonstrated the benefits of electric-acoustic stimulation (EAS) over conventional electric stimulation for adults with functional low-frequency acoustic hearing and severe-to-profound high-frequency hearing loss. These benefits potentially include better speech recognition...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.15133
更新日期:2017-02-01 00:00:00
abstract:BACKGROUND:Sloping hearing loss imposes limits on audibility for high-frequency sounds in many hearing aid users. Signal processing algorithms that shift high-frequency sounds to lower frequencies have been introduced in hearing aids to address this challenge by improving audibility of high-frequency sounds. PURPOSE:T...
journal_title:Journal of the American Academy of Audiology
pub_type: 临床试验,杂志文章
doi:10.3766/jaaa.16157
更新日期:2017-10-01 00:00:00
abstract:BACKGROUND AND PURPOSE:Multiple auditory steady-state responses (ASSRs) to stimuli modulated at approximately 80 Hz are a promising technique for threshold estimation in infants, but additional data are required. RESEARCH DESIGN:We obtained multiple ASSRs to air-conducted (AC) stimuli. STUDY SAMPLE:There were 54 chil...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.20.3.6
更新日期:2009-03-01 00:00:00
abstract::A speech test evaluation and presentation system is described. The test presentation subsystem has the flexibility and speed of live-voice testing while using recorded test materials. The speech test evaluation subsystem compares an individual subject's test performance on a monosyllabic word test with that of an aver...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1999-07-01 00:00:00
abstract::As humans, we hear the way we do because of at least three major forces. The first is phylogeny, the evolutionary changes in the auditory system since its beginnings. The second is embryology, the formation of the system in each individual. Finally, there is the interaction between the biologically determined mechanis...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章,评审
doi:
更新日期:1995-03-01 00:00:00
abstract:BACKGROUND:Cochlear implant (CI) recipients experience difficulty understanding speech in noise. Remote-microphone technology that improves the signal-to-noise ratio is recognized as an effective means to improve speech recognition in noise; however, there are no published studies evaluating the potential benefits of a...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.15005
更新日期:2015-06-01 00:00:00
abstract::The aim of this research was to study the effects of several stimulus parameters on adaptation characteristics of the auditory brainstem response (ABR). Recordings were obtained from normal hearing adults to separate trains of 5 rarefaction and 5 condensation clicks with interclick intervals of 10 msec and intertrain ...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1992-07-01 00:00:00
abstract::This study examined the influence of technology, demographic factors, and prefitting expectations, attitudes, and adjustment to hearing loss on hearing aid outcome. Clients obtaining new hearing aids completed questionnaires measuring personal adjustment to hearing loss, expectations of and attitudes toward hearing ai...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:2001-02-01 00:00:00
abstract:BACKGROUND:Previous research has shown that hearing aid wearers can successfully self-train their instruments' gain-frequency response and compression parameters in everyday situations. Combining hearing aids with a smartphone introduces additional computing power, memory, and a graphical user interface that may enable...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.15099
更新日期:2016-10-01 00:00:00
abstract:BACKGROUND:Significant growth in the U.S. population over the next 30 yr will likely increase the demand for hearing-care services. In addition, increased accessibility to hearing-care services may be realized due to increased insurance coverage associated with health-care reform efforts. In order to meet this demand, ...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章,评审
doi:10.3766/jaaa.24.5.7
更新日期:2013-05-01 00:00:00
abstract:BACKGROUND:Evidence suggests that hearing-aid users have difficulties with own-voice level control, most likely because their auditory feedback is affected by hearing-aid amplification. PURPOSE:The purpose of this study was to investigate how changes to auditory feedback affect the voice level of hearing-aid users. R...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.20.8.5
更新日期:2009-09-01 00:00:00
abstract::We characterized the 2F1-F2 distortion product reflected in the human frequency-following response (FFR). In the first experiment, we evaluated the input-output growth functions of the distortion product at 2F1-F2 (FFR-DP) for three primary pairs. In the second experiment, we tested the effect of primary tone level va...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.15.3.2
更新日期:2004-03-01 00:00:00