Smartphone-Based System for Learning and Inferring Hearing Aid Settings.

Abstract:

BACKGROUND:Previous research has shown that hearing aid wearers can successfully self-train their instruments' gain-frequency response and compression parameters in everyday situations. Combining hearing aids with a smartphone introduces additional computing power, memory, and a graphical user interface that may enable greater setting personalization. To explore the benefits of self-training with a smartphone-based hearing system, a parameter space was chosen with four possible combinations of microphone mode (omnidirectional and directional) and noise reduction state (active and off). The baseline for comparison was the "untrained system," that is, the manufacturer's algorithm for automatically selecting microphone mode and noise reduction state based on acoustic environment. The "trained system" first learned each individual's preferences, self-entered via a smartphone in real-world situations, to build a trained model. The system then predicted the optimal setting (among available choices) using an inference engine, which considered the trained model and current context (e.g., sound environment, location, and time). PURPOSE:To develop a smartphone-based prototype hearing system that can be trained to learn preferred user settings. Determine whether user study participants showed a preference for trained over untrained system settings. RESEARCH DESIGN:An experimental within-participants study. Participants used a prototype hearing system-comprising two hearing aids, Android smartphone, and body-worn gateway device-for ∼6 weeks. STUDY SAMPLE:Sixteen adults with mild-to-moderate sensorineural hearing loss (HL) (ten males, six females; mean age = 55.5 yr). Fifteen had ≥6 mo of experience wearing hearing aids, and 14 had previous experience using smartphones. INTERVENTION:Participants were fitted and instructed to perform daily comparisons of settings ("listening evaluations") through a smartphone-based software application called Hearing Aid Learning and Inference Controller (HALIC). In the four-week-long training phase, HALIC recorded individual listening preferences along with sensor data from the smartphone-including environmental sound classification, sound level, and location-to build trained models. In the subsequent two-week-long validation phase, participants performed blinded listening evaluations comparing settings predicted by the trained system ("trained settings") to those suggested by the hearing aids' untrained system ("untrained settings"). DATA COLLECTION AND ANALYSIS:We analyzed data collected on the smartphone and hearing aids during the study. We also obtained audiometric and demographic information. RESULTS:Overall, the 15 participants with valid data significantly preferred trained settings to untrained settings (paired-samples t test). Seven participants had a significant preference for trained settings, while one had a significant preference for untrained settings (binomial test). The remaining seven participants had nonsignificant preferences. Pooling data across participants, the proportion of times that each setting was chosen in a given environmental sound class was on average very similar. However, breaking down the data by participant revealed strong and idiosyncratic individual preferences. Fourteen participants reported positive feelings of clarity, competence, and mastery when training via HALIC. CONCLUSIONS:The obtained data, as well as subjective participant feedback, indicate that smartphones could become viable tools to train hearing aids. Individuals who are tech savvy and have milder HL seem well suited to take advantages of the benefits offered by training with a smartphone.

journal_name

J Am Acad Audiol

authors

Aldaz G,Puria S,Leifer LJ

doi

10.3766/jaaa.15099

subject

Has Abstract

pub_date

2016-10-01 00:00:00

pages

732-749

issue

9

eissn

1050-0545

issn

2157-3107

journal_volume

27

pub_type

杂志文章
  • Central auditory processing disorders and reduced motivation: three case studies.

    abstract::The central auditory test results for three normal-hearing children who were initially diagnosed as having a central auditory processing disorder and learning disability are presented. They were referred to the authors for second-opinion consultations. Central auditory processing retesting was performed by the authors...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Silman S,Silverman CA,Emmer MB

    更新日期:2000-02-01 00:00:00

  • The effect of presentation level on the Gaps-In-Noise (GIN) test.

    abstract::The Gaps-In-Noise (GIN) test is a new procedure used in the diagnosis of central auditory processing disorders. Performance on the GIN is recorded as approximate gap detection threshold and percent correct. In order to utilize the GIN test clinically, it is important to know how presentation level influences performan...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.18.2.6

    authors: Weihing JA,Musiek FE,Shinn JB

    更新日期:2007-02-01 00:00:00

  • Evidence against the influence of aging on distortion-product otoacoustic emissions.

    abstract::Previous research has reported reduced otoacoustic emission amplitude as a function of age. In each study, however, interpretation of findings was confounded by age-related hearing loss. The present study was designed to re-evaluate the contribution of age and peripheral hearing loss on the prevalence and amplitude of...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Strouse AL,Ochs MT,Hall JW 3rd

    更新日期:1996-10-01 00:00:00

  • Technical report: distortion product otoacoustic emissions that are not outer hair cell emissions.

    abstract:PURPOSE:To present a case study in order to alert clinicians to the possibility of occurrence of intermodulation distortion during otoacoustic emissions testing that arises from the cavity formed by the external auditory meatus and tympanic membrane rather than from the inner ear, compromising the reliability and valid...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.20.5.3

    authors: Silman S,Emmer MB,Silverman CA

    更新日期:2009-05-01 00:00:00

  • Evaluation of a "direct-comparison" approach to automatic switching in omnidirectional/directional hearing aids.

    abstract:BACKGROUND:Hearing aids today often provide both directional (DIR) and omnidirectional (OMNI) processing options with the currently active mode selected automatically by the device. The most common approach to automatic switching involves "acoustic scene analysis" where estimates of various acoustic properties of the l...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.19.9.6

    authors: Summers V,Grant KW,Walden BE,Cord MT,Surr RK,Elhilali M

    更新日期:2008-10-01 00:00:00

  • Effects of stimulus rate and gender on the auditory middle latency response.

    abstract::The effects of stimulus rate and gender on the auditory middle latency response (AMLR) waveforms were examined in 20 young adult male and female subjects. Four different repetition rates were presented to subjects (1.1/sec, 4.1/sec, 7.7/ sec, and 11.3/sec). Stimulus repetition rate had a significant effect on Pa laten...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Tucker DA,Dietrich S,Harris S,Pelletier S

    更新日期:2002-03-01 00:00:00

  • Frequency (pitch) and duration pattern tests.

    abstract::Compact disc versions of the frequency (pitch) and duration pattern tests are reported. Results are similar to previous reports on these tests using taped materials. Mean performance of normal-hearing young adults for both pattern perception tests was approximately 90 percent. There was no effect of the two presentati...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Musiek FE

    更新日期:1994-07-01 00:00:00

  • Optimizing the benefit of sound processors coupled to personal FM systems.

    abstract:BACKGROUND:Use of personal frequency modulated (FM) systems significantly improves speech recognition in noise for users of cochlear implants (CI). There are, however, a number of adjustable parameters of the cochlear implant and FM receiver that may affect performance and benefit, and there is limited evidence to guid...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 临床试验,杂志文章

    doi:10.3766/jaaa.19.8.2

    authors: Wolfe J,Schafer EC

    更新日期:2008-09-01 00:00:00

  • Observations on hearing aid users' strategies for controlling the level of their own voice.

    abstract:BACKGROUND:Evidence suggests that hearing-aid users have difficulties with own-voice level control, most likely because their auditory feedback is affected by hearing-aid amplification. PURPOSE:The purpose of this study was to investigate how changes to auditory feedback affect the voice level of hearing-aid users. R...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.20.8.5

    authors: Laugesen S,Nielsen C,Maas P,Jensen NS

    更新日期:2009-09-01 00:00:00

  • Historic perspective of the acoustic otoscope.

    abstract::The acoustic otoscope, originally called the acoustic reflectometer, was developed and produced by John and David Teele in the early 1980s. Since initial production, two different instrument versions have been developed by two separate companies. During the period of time in which the acoustic otoscope has been in pro...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 历史文章,杂志文章

    doi:

    authors: Walsh FP,Cox LC,MacDonald CB

    更新日期:1998-02-01 00:00:00

  • Acoustic and hearing aid circuit variables affecting the tolerability of aided impulsive-type sounds.

    abstract::The tolerability of aided impulsive-type stimuli was investigated in a group of 13 hearing-impaired listeners. Two linear circuits (one with a class A and one with a class D output stage) and one adaptive frequency response (AFR) circuit (with a class D output stage) were investigated. In a three-way paired-comparison...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Fortune TW,Preves DA

    更新日期:1994-09-01 00:00:00

  • Reliability of threshold estimation in hearing-impaired adults using the AMFR.

    abstract::The amplitude modulation-following response (AMFR), an auditory evoked potential elicited by continuous amplitude-modulated tones, can be recorded for carrier frequencies across the audiometric range. AMFR thresholds (based on the amplitude spectra of the responses) have been found to closely follow behavioral thresho...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Chambers RD,Meyer TA

    更新日期:1993-01-01 00:00:00

  • Balance function test correlates of the Dizziness Handicap Inventory.

    abstract::Balance Function test data alone cannot capture the reaction that a patient has to balance system disease. The present investigation examined the relations among components of the balance function examination (electronystagmography, rotational testing, and platform posturography) and self-perceived dizziness handicap,...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Jacobson GP,Newman CW,Hunter L,Balzer GK

    更新日期:1991-10-01 00:00:00

  • Audiometric correlates of the unaided APHAB.

    abstract::The Abbreviated Profile of Hearing Aid Benefit (APHAB) is a self-report questionnaire that is used to quantify the impact of a hearing problem on an individual's daily life. In this investigation, the relationships were explored between typical clinical audiometric data and the four subscale scores of the APHAB admini...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Cox RM,Alexander GC,Gray GA

    更新日期:2003-09-01 00:00:00

  • The Effect of Test, Electrode, and Rate on Electrocochleography Measures.

    abstract:BACKGROUND:Electrocochleography (ECochG) is the measurement of stimulus-related cochlear potentials and the compound action potential (AP). Its primary clinical application is with the assessment of inner ear disorders. There are few studies examining the variability of ECochG measures. PURPOSE:The objective of the st...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.17081

    authors: Lake AB,Stuart A

    更新日期:2019-01-01 00:00:00

  • Parents' perceptions of an emerging community-based newborn hearing screening program: A case study.

    abstract::Thirty-six parents of 106 children (34% response rate) born between March 2000 and February 2003 retrospectively completed the "Probe of Parents' Perceptions: An Early Hearing Detection and Intervention (EHDI) Outcome Measure" (PPP) assessing their participation in an emerging community-based newborn hearing screening...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,多中心研究

    doi:10.3766/jaaa.17.3.6

    authors: Danhauer JL,Johnson CE

    更新日期:2006-03-01 00:00:00

  • Considerations for cochlear implantation of children with sudden, fluctuating hearing loss.

    abstract::The histories of two pediatric patients who received cochlear implants with subsequent partial recovery of hearing in the nonimplanted ear are reviewed. One child had a sudden bilateral hearing loss, presumably secondary to autoimmune ear disease. The other child had a bilateral progressive hearing loss diagnosed as l...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.16.10.2

    authors: Sweetow RW,Rosbe KW,Philliposian C,Miller MT

    更新日期:2005-11-01 00:00:00

  • Short- and long-term effects of the modified swedish version of the Active Communication Education (ACE) program for adults with hearing loss.

    abstract:BACKGROUND:In Sweden, there is a lack of evidence-based rehabilitation programs for hearing loss. The Active Communication Education program (ACE) has successfully been used in Australia and was translated and evaluated in a Swedish pilot study. The pilot study included 23 participants (age 87 yr). No statistically sig...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.25.9.7

    authors: Oberg M,Bohn T,Larsson U

    更新日期:2014-10-01 00:00:00

  • Demand for audiology services: 30-yr projections and impact on academic programs.

    abstract:BACKGROUND:Significant growth in the U.S. population over the next 30 yr will likely increase the demand for hearing-care services. In addition, increased accessibility to hearing-care services may be realized due to increased insurance coverage associated with health-care reform efforts. In order to meet this demand, ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,评审

    doi:10.3766/jaaa.24.5.7

    authors: Windmill IM,Freeman BA

    更新日期:2013-05-01 00:00:00

  • Investigating speechreading and deafness.

    abstract:BACKGROUND:The visual speech signal can provide sufficient information to support successful communication. However, individual differences in the ability to appreciate that information are large, and relatively little is known about their sources. PURPOSE:Here a body of research is reviewed regarding the development ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,评审

    doi:10.3766/jaaa.21.3.4

    authors: Auer ET

    更新日期:2010-03-01 00:00:00

  • Effects of open-set and closed-set task demands on spoken word recognition.

    abstract::Closed-set tests of spoken word recognition are frequently used in clinical settings to assess the speech discrimination skills of hearing-impaired listeners, particularly children. Speech scientists have reported robust effects of lexical competition and talker variability in open-set tasks but not closed-set tasks, ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,随机对照试验

    doi:10.3766/jaaa.17.5.4

    authors: Clopper CG,Pisoni DB,Tierney AT

    更新日期:2006-05-01 00:00:00

  • Knowledge of Hearing Loss among University Students Pursuing Careers in Health Care.

    abstract:BACKGROUND:Albeit limited, research suggests that students pursuing careers in health care receive limited training on the provision of services for people with hearing loss. As the incidence of hearing loss continues to increase among Americans, it is critical that medical professionals understand how hearing loss amo...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.17071

    authors: Squires ES,Pakulski LA,Glassman J,Diehm E

    更新日期:2019-04-01 00:00:00

  • Current research with cochlear implants at Arizona State University.

    abstract::In this article we review, and discuss the clinical implications of, five projects currently underway in the Cochlear Implant Laboratory at Arizona State University. The projects are (1) norming the AzBio sentence test, (2) comparing the performance of bilateral and bimodal cochlear implant (CI) patients in realistic ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.23.6.2

    authors: Dorman MF,Spahr A,Gifford RH,Cook S,Zhang T,Loiselle L,Yost W,Cardy L,Whittingham J,Schramm D

    更新日期:2012-06-01 00:00:00

  • Development of the Three-Clinic Hearing Aid Selection Profile (HASP).

    abstract::The Three-Clinic Hearing Aid Selection Profile (HASP) was developed to assess a patient's beliefs about a number of basic considerations felt to be critical to the hearing aid selection (HAS) process. These characteristics are felt to be key to the acceptance of amplification and include motivation, expectations, cost...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Jacobson GP,Newman CW,Fabry DA,Sandridge SA

    更新日期:2001-03-01 00:00:00

  • Normal summating potential to tone bursts recorded from the tympanic membrane in humans.

    abstract::The use of tone-burst stimuli for electrocochleography (ECochG) may offer certain advantages over conventional broad-band clicks. Namely, the summating potential (SP) component can be examined at different frequencies and may be easier to define and measure. To apply these findings clinically, it would first be necess...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Ferraro JA,Blackwell WL,Mediavilla SJ,Thedinger BS

    更新日期:1994-01-01 00:00:00

  • Evaluation of a cognitive test battery in young and elderly normal-hearing and hearing-impaired persons.

    abstract::A cognitive test battery sensitive to processes important for speech understanding was developed and investigated. Test stimuli are presented as text or in an auditory or audiovisual modality. The tests investigate phonologic processing and verbal information processing. Four subject groups, young/elderly with normal-...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Hällgren M,Larsby B,Lyxell B,Arlinger S

    更新日期:2001-07-01 00:00:00

  • Hearing-aid-processed tone pips: electroacoustic and ABR characteristics.

    abstract::The auditory brainstem response (ABR) recorded while wearing a hearing aid may supply supplemental information about the benefit and appropriateness of the hearing aid for certain infants. The purposes of this study were (1) to determine the effects of different output limiting circuits on the acoustics of tone-pip st...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Brown E,Klein AJ,Snydee KA

    更新日期:1999-04-01 00:00:00

  • Effects of speech rate, background noise, and simulated hearing loss on speech rate judgment and speech intelligibility in young listeners.

    abstract:PURPOSE:To study the effect of noise on speech rate judgment and signal-to-noise ratio threshold (SNR50) at different speech rates (slow, preferred, and fast). RESEARCH DESIGN:Speech rate judgment and SNR50 tasks were completed in a normal-hearing condition and a simulated hearing-loss condition. STUDY SAMPLE:Twenty-...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.20.1.3

    authors: Adams EM,Moore RE

    更新日期:2009-01-01 00:00:00

  • Intraoperative Electrically Evoked Compound Action Potential (ECAP) Measurements in Traditional and Hearing Preservation Cochlear Implantation.

    abstract:BACKGROUND:In current practice, the status of residual low-frequency acoustic hearing in hearing preservation cochlear implantation (CI) is unknown until activation two to three weeks postoperatively. The intraoperatively measured electrically evoked compound action potential (ECAP), a synchronous response from electri...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.18052

    authors: Nassiri AM,Yawn RJ,Gifford RH,Haynes DS,Roberts JB,Gilbane MS,Murfee J,Bennett ML

    更新日期:2019-11-01 00:00:00

  • Loudness as a cue for acceptable noise levels.

    abstract:BACKGROUND/PURPOSE:The acceptable noise level (ANL) test is the only test that is known to predict success with hearing aids with a high degree of accuracy. A person's ANL is the maximal amount of background noise that he or she is "willing to put up with" while listening to running speech. It is defined as the speech ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.25.6.10

    authors: Recker KL,McKinney MF,Edwards BW

    更新日期:2014-06-01 00:00:00