Effects of framing coil shape, orientation, and thickness on intra-aneurysmal flow.

Abstract:

:To study the effects of the geometrical characteristics of a framing coil on aneurysm thromboembolization efficacy, the hemodynamics in lateral aneurysms filled with coils having a different shape, orientation, and thickness were analyzed using computational fluid dynamics. The aneurysms packed with vortex and cage-shaped coils were modeled using three different coil orientations: transverse, parallel, and orthogonal. The orthogonal orientation of a vortex coil and parallel orientation of a cage-shaped coil showed higher inflow, vorticity, and wall shear stress in the dome region, which provide an unfavorable hemodynamic environment for thromboembolization. Thicker coils also produced unfavorable hemodynamic conditions compared to normal coils having the same shape, orientation, and total coil volume. Though the effects of coil shape and orientation on the hemodynamic parameters of interest were not consistent, the open area at the distal half of the mid-transverse plane of an aneurysm showed significant positive correlation with flow into the dome region and mean vorticity in the dome region. Therefore, blocking the distal mid-transverse plane of an aneurysm using coils would effectively reduce the intra-aneurysmal flow activity and provide a more efficient hemodynamic environment for thromboembolization.

journal_name

Med Biol Eng Comput

authors

Jeong W,Han MH,Rhee K

doi

10.1007/s11517-013-1073-2

subject

Has Abstract

pub_date

2013-09-01 00:00:00

pages

981-90

issue

9

eissn

0140-0118

issn

1741-0444

journal_volume

51

pub_type

杂志文章
  • Registration and geometric modelling of the spine during scoliosis surgery: a comparison study of different pre-operative reconstruction techniques and intra-operative tracking systems.

    abstract::During scoliosis instrumentation surgery, it is difficult for surgeons fully to track vertebral motion in 3D, because only the posterior elements of the spine are exposed. Different intra-operative modelling approaches are evaluated using a registration technique that matches intra-operative measurements with a 3D pre...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513328

    authors: Mac-Thiong JM,Aubin CE,Dansereau J,de Guise JA,Brodeur P,Labelle H

    更新日期:1999-07-01 00:00:00

  • Estimation of single motor unit conduction velocity from surface electromyogram signals detected with linear electrode arrays.

    abstract::This work addresses the problem of estimating the conduction velocity (CV) of single motor unit (MU) action potentials from surface EMG signals detected with linear electrode arrays during voluntary muscle contractions. In ideal conditions, that is without shape or scale changes of the propagating signals and with add...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344807

    authors: Farina D,Muhammad W,Fortunato E,Meste O,Merletti R,Rix H

    更新日期:2001-03-01 00:00:00

  • Cardiac anisotropy in boundary-element models for the electrocardiogram.

    abstract::The boundary-element method (BEM) is widely used for electrocardiogram (ECG) simulation. Its major disadvantage is its perceived inability to deal with the anisotropic electric conductivity of the myocardial interstitium, which led researchers to represent only intracellular anisotropy or neglect anisotropy altogether...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0472-x

    authors: Potse M,Dubé B,Vinet A

    更新日期:2009-07-01 00:00:00

  • A weighted ensemble-based active learning model to label microarray data.

    abstract::Classification of cancerous genes from microarray data is an important research area in bioinformatics. Large amount of microarray data are available, but it is very costly to label them. This paper proposes an active learning model, a semi-supervised classification approach, to label the microarray data using which p...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02238-1

    authors: De R,Chakraborty A,Chatterjee A,Sarkar R

    更新日期:2020-10-01 00:00:00

  • Experimental and numerical investigation on soft tissue dynamic response due to turbulence-induced arterial vibration.

    abstract::Peripheral arterial occlusive disease is a serious cardiovascular disorder. The arterial occlusion leads to turbulent flow and arterial sound generation on the inner vessel wall. Stenosis-induced vibro-acoustic waves propagate through the surrounding soft tissues and reach the skin surface. In this study, the feasibil...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-01995-y

    authors: Salman HE,Yazicioglu Y

    更新日期:2019-08-01 00:00:00

  • Analysis of amplitude and frequency variations of essential and Parkinsonian tremors.

    abstract::Variations in the amplitude and period of essential and Parkinsonian tremors were studied. It was found that the variations in frequency (or period) were mostly similar to the white noise, with the standard deviation typically less than 10% of the mean, whereas the variations in amplitude were much larger, with standa...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344710

    authors: Gao JB

    更新日期:2004-05-01 00:00:00

  • CFD simulations for paper-based DNA amplification reaction (LAMP) of Mycobacterium tuberculosis-point-of-care diagnostic perspective.

    abstract::Loop-mediated isothermal amplification or LAMP has been identified to be an efficient technology for point-of-care diagnostics. Paper-based LAMP technique has tremendous potential in replacing the existing tube-based technology as the manufacturing cost of a paper-based device is comparatively lower and easy-to-use. L...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02082-y

    authors: Das D,Panigrahi PK

    更新日期:2020-02-01 00:00:00

  • Dynamics of magnetic particles in cylindrical Halbach array: implications for magnetic cell separation and drug targeting.

    abstract::Magnetic nanoparticles for therapy and diagnosis are at the leading edge of the rapidly developing field of bionanotechnology. In this study, we have theoretically studied motion of magnetic nano- as well as micro-particles in the field of cylindrical Halbach array of permanent magnets. Magnetic flux density was model...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0636-8

    authors: Babinec P,Krafcík A,Babincová M,Rosenecker J

    更新日期:2010-08-01 00:00:00

  • Model of glucose sensor error components: identification and assessment for new Dexcom G4 generation devices.

    abstract::It is clinically well-established that minimally invasive subcutaneous continuous glucose monitoring (CGM) sensors can significantly improve diabetes treatment. However, CGM readings are still not as reliable as those provided by standard fingerprick blood glucose (BG) meters. In addition to unavoidable random measure...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-014-1226-y

    authors: Facchinetti A,Del Favero S,Sparacino G,Cobelli C

    更新日期:2015-12-01 00:00:00

  • Automatic P-wave analysis of patients prone to atrial fibrillation.

    abstract::A method is presented for automatic analysis of the P-wave, based on lead II of a 12-lead standard ECG, in resting conditions during a routine examination for the detection of patients prone to atrial fibrillation (AF), one of the most prevalent arrhythmias. First, the P-wave was delineated, and this was achieved in t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02347697

    authors: Clavier L,Boucher JM,Lepage R,Blanc JJ,Cornily JC

    更新日期:2002-01-01 00:00:00

  • OKAS-3D: optoelectronic jaw movement recording system with six degrees of freedom.

    abstract::OKAS-3D is a further development of the single floating circle target tracker. This tracker consists of a cathode ray tube display, a lens in front of the display and a circular light-sensitive photocell placed in the image field of the lens. A small circular trace generated on the screen is focused around the photoce...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02510786

    authors: Naeije M,Van der Weijden JJ,Megens CC

    更新日期:1995-09-01 00:00:00

  • Interface mechanics in external prosthetics: review of interface stress measurement techniques.

    abstract::Instrumentation to measure accurately the stresses at the interface of a residual limb and prosthetic socket has a strong potential for use in prosthetic treatment. As a tool in the clinical setting, the device would allow a clinician to identify sites of excessive loading, information which could then be combined wit...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/BF02522507

    authors: Sanders JE

    更新日期:1995-07-01 00:00:00

  • Delineation of the ischemic stroke lesion based on watershed and relative fuzzy connectedness in brain MRI.

    abstract::Precise segmentation of stroke lesions from brain magnetic resonance (MR) images poses a challenging task in automated diagnosis. In this paper, we proposed a new method called watershed-based lesion segmentation algorithm (WLSA), which is a novel intensity-based segmentation technique used to delineate infarct lesion...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1726-7

    authors: Subudhi A,Jena S,Sabut S

    更新日期:2018-05-01 00:00:00

  • Ultrasonic characterization of ultrasound contrast agents.

    abstract::The main constituent of an ultrasound contrast agent (UCA) is gas-filled microbubbles. An average UCA contains billions per ml. These microbubbles are excellent ultrasound scatterers due to their high compressibility. In an ultrasound field they act as resonant systems, resulting in harmonic energy in the backscattere...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0497-1

    authors: de Jong N,Emmer M,van Wamel A,Versluis M

    更新日期:2009-08-01 00:00:00

  • Influence of synchronous and sequential stimulation on muscle fatigue.

    abstract::In acute experiments the sciatic nerve of the rat is electrically stimulated to induce fatigue in the medial Gastrocnemius muscle. Fatigue tests are carried out using intermittent stimulation of different compartments (sequential) or a single compartment (synchronous) of the sciatic nerve. The activation of different ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02530036

    authors: Thomsen M,Veltink PH

    更新日期:1997-05-01 00:00:00

  • Using three-dimensional multigrid-based snake and multiresolution image registration for reconstruction of cranial defect.

    abstract::In cranioplasty, neurosurgeons use bone grafts to repair skull defects. To ensure the protection of intracranial tissues and recover the original head shape for aesthetic purposes, a custom-made pre-fabricated prosthesis must match the cranial incision as closely as possible. In our previous study (Liao et al. in Med ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0972-y

    authors: Liao YL,Lu CF,Wu CT,Lee JD,Lee ST,Sun YN,Wu YT

    更新日期:2013-02-01 00:00:00

  • Non-contact diagnostic system for sleep apnea-hypopnea syndrome based on amplitude and phase analysis of thoracic and abdominal Doppler radars.

    abstract::Full-night polysomnography (PSG) has been recognized as the gold standard test for sleep apnea-hypopnea syndrome (SAHS). However, PSG examinees are physically restrained for the full night by many contact sensors and obtrusive connecting cables, inducing mental stress. We developed a non-contact SAHS diagnostic system...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1370-z

    authors: Kagawa M,Tojima H,Matsui T

    更新日期:2016-05-01 00:00:00

  • Classification of foetal heart rate sequences based on fractal features.

    abstract::Visual inspection of foetal heart rate (FHR) sequences is an important means of foetal well-being evaluation. The application of fractal features for classifying physiologically relevant FHR sequence patterns is reported. The use of fractal features is motivated by the difficulties exhibited by traditional classificat...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02510743

    authors: Felgueiras CS,de Sá JP,Bernardes J,Gama S

    更新日期:1998-03-01 00:00:00

  • Model for the assessment of heart period and arterial pressure variability interactions and of respiration influences.

    abstract::A model which assesses the closed-loop interaction between heart period (HP) and arterial pressure (AP) variabilities and the influence of respiration on both is applied to evaluate the sources of low frequency (LF approximately 0.1 Hz) and high frequency (HF, respiratory rate approximately 0.25 Hz) in conscious dogs ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02518911

    authors: Baselli G,Cerutti S,Badilini F,Biancardi L,Porta A,Pagani M,Lombardi F,Rimoldi O,Furlan R,Malliani A

    更新日期:1994-03-01 00:00:00

  • Detection of very low-frequency oscillations of cerebral haemodynamics is influenced by data detrending.

    abstract::Recent studies were investigated that report spontaneous oscillations of cerebral perfusion in the very low-frequency range (0.01-0.04 Hz), emphasising details of spectral estimation. The effects of different spectral estimation procedures were compared, using simulated and clinical data. It was shown that data detren...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02343541

    authors: Müller T,Reinhard M,Oehm E,Hetzel A,Timmer J

    更新日期:2003-01-01 00:00:00

  • Detection of compressed tracheal sound patterns with large amplitude variation during sleep.

    abstract::The objective of the present work was to develop automated methods for the compressed tracheal breathing sound analysis. Overnight tracheal breathing sound was recorded from ten apnoea patients. From each patient, three different types of tracheal sound deflection pattern, each of 10 min duration, were visually scored...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-008-0317-z

    authors: Kulkas A,Rauhala E,Huupponen E,Virkkala J,Tenhunen M,Saastamoinen A,Himanen SL

    更新日期:2008-04-01 00:00:00

  • Silicon-based microelectrodes for neurophysiology, micromachined from silicon-on-insulator wafers.

    abstract::A process is described for the fabrication of silicon-based microelectrodes for neurophysiology using bonded and etched-back silicon-on-insulator (BESOI) wafers. The probe shapes are defined without high levels of boron doping in the silicon; this is considered as a step towards producing probes with active electronic...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344773

    authors: Ensell G,Banks DJ,Richards PR,Balachandran W,Ewins DJ

    更新日期:2000-03-01 00:00:00

  • Reliability of the mechanomyogram detected with an accelerometer during voluntary contractions.

    abstract::The accelerometer is used for mechanomyogram (MMG) recordings of muscle contractions. Although the mechanical characteristics of other MMG transducers have been determined with reference to the accelerometer, mechanical aspects of the accelerometer itself, including the weight of the transducer, have not been verified...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344888

    authors: Watakabe M,Mita K,Akataki K,Ito K

    更新日期:2003-03-01 00:00:00

  • A computerized volumetric segmentation method applicable to multi-centre MRI data to support computer-aided breast tissue analysis, density assessment and lesion localization.

    abstract::Density assessment and lesion localization in breast MRI require accurate segmentation of breast tissues. A fast, computerized algorithm for volumetric breast segmentation, suitable for multi-centre data, has been developed, employing 3D bias-corrected fuzzy c-means clustering and morphological operations. The full br...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1484-y

    authors: Ertas G,Doran SJ,Leach MO

    更新日期:2017-01-01 00:00:00

  • New method using multi-regression analysis on evoked electromyography during movement to adjust stimulation conditions.

    abstract::A new method of stimulation of the lower extremities was devised that automatically adjusts the stimulation conditions at any angle of the knee joint. An M-wave is considered to indicate the stimulation conditions, because it is the waveform that results from direct stimulation to the axon of the alpha motor neuron. T...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02351018

    authors: Tanabe S,Muraoka Y,Tomita Y

    更新日期:2004-01-01 00:00:00

  • Validation of the non-stereo corresponding points stereoradiographic 3D reconstruction technique.

    abstract::Several 3D reconstruction techniques deriving from stereoradiographic DLT have been presented during the last 15 years, but these techniques have usually been limited in accuracy because of the small number of corresponding anatomical landmarks identified on both radiographs. A new technique has recently been proposed...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344797

    authors: Mitulescu A,Semaan I,De Guise JA,Leborgne P,Adamsbaum C,Skalli W

    更新日期:2001-03-01 00:00:00

  • A novel finite element model-based navigation system-supported workflow for breast tumor excision.

    abstract::In the case of female breast cancer, a breast-conserving excision is often desirable. This surgery is based on preoperatively gathered MRI, mammography, and sonography images. These images are recorded in multiple patient positions, e. g., 2D mammography images in standing position with a compressed breast and 3D MRI ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-01977-0

    authors: Esslinger D,Rapp P,Knödler L,Preibsch H,Tarín C,Sawodny O,Brucker SY,Hahn M

    更新日期:2019-07-01 00:00:00

  • Development of an eye-movement analyser possessing functions for wireless transmission and autocalibration.

    abstract::An eye pointer was developed as a new line-of-sight displacement analyser. It analyses an observer's eye movements and superimposes their line of vision on a TV image which is the same as their view. A newly developed miniature colour field camera and very compact eye-movement sensors are attached to a translucent rei...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446149

    authors: Yamada M,Fukuda T,Hirota M

    更新日期:1990-07-01 00:00:00

  • Hypothetical neural control of human bipedal walking with voluntary modulation.

    abstract::A hypothetical neuromusculoskeletal model is developed to simulate human normal walking and its modulated behaviors. A small set of neural periodic patterns drive spinal muscle synergies which in turn lead to specific pattern of muscle activation and supraspinal feedback systems maintain postural balance during walkin...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0277-8

    authors: Jo S

    更新日期:2008-02-01 00:00:00

  • Synergistic effects of local temperature enhancements on cellular responses in the context of high-intensity, ultrashort electric pulses.

    abstract::Results of self-consistent analyses of cells show the possibility of temperature increases at membranes in response to a single nanosecond, high-voltage pulse, at least over small sections of the membrane. Molecular Dynamics simulations indicate that such a temperature increase could facilitate poration, which is one ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-011-0745-z

    authors: Song J,Joshi RP,Schoenbach KH

    更新日期:2011-06-01 00:00:00