Abstract:
:Exposure to drugs and toxins is a major cause for the rising number of emergency department visits each year. Immunoassays are commonly used in the emergency department to provide rapid turnaround time for acute care. The purpose of this study was to compare two automated immunoassay chemistry analyzers to determine which platform produced the fewest number of false positive/negative results. Residual patient urine samples were were collected for each of the following drugs/drug classes: cocaine (n = 40), opiates (n = 45), and amphetamines (n = 54) and confirmed either positive or negative by mass spectrometry. Split sample analyses of these specimens were performed on both the Roche COBAS INTEGRA 400 plus and Ortho Vitros 5,1 FS instruments. The results from the two chemistry analyzers were compared to confirmed results. Both immunoassays were prone to false positive results for cocaine and false negative results for opiates and amphetamines. The Vitros Fusion analyzer generated fewer false positive and false negative results for opiate and amphetamine testing than the Roche Integra, but the platforms performed comparably for cocaine.
journal_name
J Anal Toxicoljournal_title
Journal of analytical toxicologyauthors
Johnson-Davis KL,Thompson CD,Clark CJ,McMillin GA,Lehman CMdoi
10.1093/jat/bks028subject
Has Abstractpub_date
2012-06-01 00:00:00pages
345-8issue
5eissn
0146-4760issn
1945-2403pii
bks028journal_volume
36pub_type
杂志文章abstract::The efficiency of ethanolamine and potassium hydroxide (KOH) as trapping agents for CO2 was determined using a flow of 500 mL/min through CO2 absorption towers containing trapping solutions. Radiolabeled 14CO2 was produced by acidification of suspensions containing Ba14CO3. Both 100% ethanolamine and 5M ethanolamine i...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/10.1.24
更新日期:1986-01-01 00:00:00
abstract::A relatively simple procedure for the determination of carboxyhemoglobin percent saturation in postmortem samples is described. The procedure involves a quick and accurate method for calibration of the gas chromatograph to carbon monoxide. The mixed gases are extracted from blood prior to introduction into the gas chr...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/4.4.181
更新日期:1980-07-01 00:00:00
abstract::In previous experimental studies on heroin metabolites excretion in urine, the first sample was often collected a few hours after intake. In forensic cases, it is sometimes questioned if a positive urine result is expected e.g., 30 min after intake. The aim of this study was to investigate urinary excretion of heroin ...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/bkx017
更新日期:2017-06-01 00:00:00
abstract::A method is presented for the extraction and screening of basic and neutral drugs, including amphetamines. Two milliliters of blood are buffered to pH 9.0 and extracted with n-chlorobutane. Underivatized extracts are analyzed simultaneously on two complementary capillary columns placed together in one injection port u...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/10.5.198
更新日期:1986-09-01 00:00:00
abstract::Hypertension is one of the most important modifiable risk factor causing cardiovascular disease. Unfortunately, non-adherence to antihypertensive medications is frequently observed in hypertensive patients and can lead to an increase in morbidity and mortality. Until recently, there was no robust clinical method to ob...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/bkaa192
更新日期:2020-12-10 00:00:00
abstract::Gamma-hydroxybutyrate (GHB) is an endogenous compound, but its presence in postmortem blood presents a challenge when interpreting elevated levels as GHB is misused as a recreational drug and is also produced postmortem. A total of 387 postmortem cases (273 male and 114 female) submitted to the toxicology laboratory b...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/bku088
更新日期:2014-10-01 00:00:00
abstract::A 5-mg dose of cocaine free base applied to the volar forearm skin surface of a volunteer resulted in a maximal urinary benzoylecgonine concentration of 55 ng/mL at 48 h, using discrete urine specimens. A total of 58 micrograms of benzoylecgonine, representing 1.2% of the dose, was excreted in the 96-h urine. An ident...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/14.6.383
更新日期:1990-11-01 00:00:00
abstract::A simple, rapid, and reliable gas-liquid chromatographic (GLC) confirmation procedure was developed for urine samples found positive by the EMIT-dau benzodiazepine metabolite assay. The procedure involves acid hydrolysis, organic extraction, and identification using GLC-nitrogen-phosphorus detection (NPD). The method ...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/6.6.305
更新日期:1982-11-01 00:00:00
abstract::Caffeine is the most widely consumed drug in the world with coffee representing a major source of intake. Despite widespread availability, various medical conditions necessitate caffeine-restricted diets. Patients on certain prescription medications are advised to discontinue caffeine intake. Such admonition has impli...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/30.8.611
更新日期:2006-10-01 00:00:00
abstract::A rapid, specific and quantitative high-performance liquid chromatography assay procedure is described for the determination of ICI 125, 211, (I), a guanidino-thiazole H2-receptor antagonist, in small samples of animal plasma. A 0.2 mL aliquot of plasma is extracted at pH 9 with ethyl acetate. After reconstitution in ...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/4.5.244
更新日期:1980-09-01 00:00:00
abstract::Endogenous γ-hydroxybutyric acid (GHB) concentrations in blood and urine are well documented, but there are very little data on natural levels in saliva, a biological matrix increasingly used for drug testing. We measured endogenous GHB concentrations in 120 unpaid volunteers who also provided anonymous epidemiologica...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/anatox/35.3.148
更新日期:2011-04-01 00:00:00
abstract::The measurement of cefoperazone concentrations in cerebral spinal fluid (CSF) is important to understanding the biodisposition and pharmacokinetic behavior of the drug. We have demonstrated that cefoperazone is unstable in methanol and at alkaline pH and these factors may affect the accurate quantitation of the drug i...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/6.2.85
更新日期:1982-03-01 00:00:00
abstract::The Substance Abuse and Mental Health Services Administration (SAMHSA) is currently evaluating hydrocodone (HC) for inclusion in the Mandatory Guidelines for Federal Workplace Drug Testing Programs. This study evaluated the time course of HC, norhydrocodone (NHC), dihydrocodeine (DHC) and hydromorphone (HM) in paired ...
journal_title:Journal of analytical toxicology
pub_type: 临床试验,杂志文章
doi:10.1093/jat/bkv050
更新日期:2015-09-01 00:00:00
abstract::Salicylate excretion was studied in the breast milk of a nursing mother (Patient A) taking chronic therapeutic doses of aspirin, and caffeine excretion was monitored in the breast milk of a nursing mother (Patient B) who was a heavy coffee drinker. Salicylate concentrations were maximal in serum at 2.25 hours (10.8 mg...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/6.2.64
更新日期:1982-03-01 00:00:00
abstract::A new method was developed to apply the advantages of automated gas chromatographic headspace analysis to delayed measurement of alcohol in whole breath (W-B). End-expiratory breath and vapor-alcohol samples were collected in sealed, heated 22-mL glass vials, stored for 0-15 days, and thereafter analyzed for alcohol b...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/6.5.217
更新日期:1982-09-01 00:00:00
abstract::Draft guidelines for the use of oral fluid for workplace drug testing are under development by the Substance Abuse and Mental Health Services Administration (SAMHSA) in cooperation with industry and researchers. Comparison studies of the effectiveness of oral fluid testing versus urine testing are needed to establish ...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/26.8.541
更新日期:2002-11-01 00:00:00
abstract::Methyl methacrylate polymer (PolyMMA) is widely used as the composite resin for the dental plate. During the fabrication process of PolyMMA for the polymerization reaction, benzoylperoxide (BPO) and N,N-dimethyl p-toluidine (DMPT) are added as the initiator and the stimulator, respectively. Because these compounds exh...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/17.2.73
更新日期:1993-03-01 00:00:00
abstract::A liquid chromatographic method was developed for the analysis of indandione and 4-hydroxycoumarin anticoagulant rodenticides in blood serum and liver. The method enabled the measurement of serum and liver concentrations of eight anticoagulant rodenticides: brodifacoum, bromadiolone, chlorophacinone, coumafuryl, couma...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/17.1.56
更新日期:1993-01-01 00:00:00
abstract::We present a method that permits the simultaneous analysis of carbamazepine (CBZ) and its major biotransformation products, carbamazepine-10,11-epoxide (CBZ-E) and carbamazepine-10,11-dihydroxide (CBZ-diOH), in plasma samples. The method consists of plasma extraction in alkaline medium with NaCl added using chloroform...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/16.2.88
更新日期:1992-03-01 00:00:00
abstract::The Abbott TDx Urine Amphetamine/Methamphetamine II fluorescence polarization immunoassay technique was applied to the determination of D-methamphetamine in hemolyzed whole blood. The assay was found to have 100% cross-reactivity with D-methamphetamine and only an 8% cross-reactivity with L-methamphetamine. Whole bloo...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/16.2.115
更新日期:1992-03-01 00:00:00
abstract::Ethiofencarb is one of the carbamate compounds, which are, in general, less toxic than organophosphorus insecticides. This is due to their reversible acetylcholinesterase inhibition and relative inability to cross the blood-brain barrier. Generally, ethiofencarb is regarded to be of low toxicity (LD(50) > 200 mg/kg); ...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/33.7.389
更新日期:2009-09-01 00:00:00
abstract::Preliminary data regarding the use of vernix caseosa (VC) as an alternative to other biological specimens for the determination of fetal cocaine exposure are presented. Advantages of VC analysis include its presence on all newborn babies, historical record of drug exposure, and ease of collection and storage. Fifteen ...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/20.6.509
更新日期:1996-10-01 00:00:00
abstract::The method presented describes a sensitive and specific quantitative assay for the determination of flumazenil in human plasma. Flumazenil and an internal standard, midazolam, are isolated by a basic extraction. The final extract is separated on a 25-m BP-1 capillary column and drugs are detected by selected ion monit...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/15.4.202
更新日期:1991-07-01 00:00:00
abstract::A variety of chemical agents were evaluated to determine their effects on fluorescence polarization immunoassays for drugs of abuse. Sixteen different agents, at concentrations up to 10%, were tested against urine assays for cannabinoids, cocaine (metabolite), amphetamines, opiates, phencyclidine (PCP), and barbiturat...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/17.1.14
更新日期:1993-01-01 00:00:00
abstract::The present study evaluates the suitability of headspace gas chromatography (GC) with a capillary column as a method for determining the ethanol content in different biological fluids. This procedure allows the use of headspace GC not only as a reference method but also in routine diagnostics and monitoring work. The ...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/19.4.241
更新日期:1995-07-01 00:00:00
abstract::Continuing our previous studies analyzing drugs of abuse in municipal wastewater, a method was developed for the analysis of opiates in wastewater samples using liquid chromatography coupled with tandem mass spectrometry (LC-MS-MS). Eight opiate drugs and metabolites were analyzed including codeine, hydrocodone, hydro...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/bkw022
更新日期:2016-06-01 00:00:00
abstract::Two cases of lethal overdose by temazepam are presented. In both cases, temazepam was the only drug detected, and there was no involvement of alcohol. The drug concentrations in blood, urine, and liver were measured. ...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/10.2.77
更新日期:1986-03-01 00:00:00
abstract::The objective was to develop a simple routine method for quantitative measurement of endogenous formic acid in plasma and whole blood using headspace gas chromatography-flame ionization detection. (GC-FID). Two-hundred microliters of sample was placed in a 1-mL glass vial. Fifty microliters of aqueous ethanol (10%) wa...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/31.6.342
更新日期:2007-07-01 00:00:00
abstract::Human urine was tested for tricyclic antidepressants with fluorescence polarization immunoassay (FPIA) reagents on Abbott's ADx system and with EIA reagents on Syva's ETS system. A 75-ng/mL imipramine calibrator cutoff was used with the ADx system and a 300-ng/mL nortriptyline calibrator cutoff with the ETS system. Th...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/14.5.273
更新日期:1990-09-01 00:00:00
abstract::We describe an assay for measuring cocaine and benzoylecgonine in meconium of infants born to mothers suspected of using cocaine during their pregnancy. The assay involves the use of fluorescence polarization immunoassay (FPIA) to screen for benzoylecgonine in a methanolic extract of the meconium. The FPIA is sensitiv...
journal_title:Journal of analytical toxicology
pub_type: 杂志文章
doi:10.1093/jat/16.4.261
更新日期:1992-07-01 00:00:00