Toward standardization of carbohydrate-deficient transferrin (CDT) measurements: II. Performance of a laboratory network running the HPLC candidate reference measurement procedure and evaluation of a candidate reference material.

Abstract:

:Carbohydrate-deficient transferrin (CDT) is a descriptive term used for a temporary change in the transferrin glycosylation profile caused by alcohol, and used as a biomarker of chronic high alcohol consumption. The use of an array of methods for measurement of CDT in various absolute or relative amounts, and sometimes covering different transferrin glycoforms, has complicated the comparability of results and caused confusion among medical staff. This situation prompted initiation of an IFCC Working Group on CDT standardization. This second publication of the WG-CDT covers the establishment of a network of reference laboratories running a high-performance liquid chromatography (HPLC) candidate reference measurement procedure, and evaluation of candidate secondary reference materials. The network laboratories demonstrated good and reproducible performance and thus can be used to assign target values for calibrators and controls. A candidate secondary reference material based on native human serum lyophilized with a cryo-/lyoprotectant to prevent protein denaturation was found to be commutable and stable during storage. A proposed strategy for calibration of different CDT methods is also presented. In an external quality assurance study involving 66 laboratories and covering the current routine CDT assays (HPLC, capillary electrophoresis and immunoassay), recalculation of observed results based on the nominal values for the candidate calibrator reduced the overall coefficient of variation from 18.9% to 5.5%. The logistics for distribution of reference materials and review of results were found to be functional, indicating that a full reference system for CDT may soon be available.

journal_name

Clin Chem Lab Med

authors

Helander A,Wielders JP,Jeppsson JO,Weykamp C,Siebelder C,Anton RF,Schellenberg F,Whitfield JB,IFCC Working Group on Standardization of Carbohydrate-Deficient Transferrin (WG-CDT).

doi

10.1515/CCLM.2010.322

subject

Has Abstract

pub_date

2010-11-01 00:00:00

pages

1585-92

issue

11

eissn

1434-6621

issn

1437-4331

journal_volume

48

pub_type

杂志文章
  • Prevalence of atrophic gastritis in dyspeptic patients in Piedmont. A survey using the GastroPanel test.

    abstract:BACKGROUND:Chronic atrophic gastritis (CAG) is a precursor of the intestinal type of gastric cancer, the second leading cause of cancer-related death worldwide. GastroPanel is a recently marketed serological kit for the non-invasive diagnosis of CAG, defined by some authors "even more reliable than biopsy histology". T...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2010.256

    authors: Lombardo L,Leto R,Molinaro G,Migliardi M,Ravarino N,Rocca R,Torchio B

    更新日期:2010-09-01 00:00:00

  • Poor prognosis indicated by nucleated red blood cells in peripheral blood is not associated with organ failure of the liver or kidney.

    abstract:BACKGROUND:The appearance of nucleated red blood cells (NRBCs) in peripheral blood is associated with a variety of severe diseases. When NRBCs are detected in blood, this is generally associated with increased mortality. METHODS:In a prospective study, NRBCs and other laboratory parameters were measured daily in the p...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2006.183

    authors: Stachon A,Holland-Letz T,Kempf R,Becker A,Friese J,Krieg M

    更新日期:2006-01-01 00:00:00

  • Diagnostic testing for a high-grade inflammation: parameter dynamics and novel markers.

    abstract:BACKGROUND:The timely detection of severe inflammatory conditions is of great importance for early therapy initiation and the patient's prognosis. The complex humoral and cellular processes involved in inflammation offer many opportunities for diagnostic testing, which are still unused in clinical practice. We investig...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2014-0482

    authors: Hoffmann C,Hoffmann P,Zimmermann M

    更新日期:2015-03-01 00:00:00

  • Multicenter evaluation of the analytical and clinical performance of the Elecsys S100 immunoassay in patients with malignant melanoma.

    abstract::The aim of this multicenter study was to evaluate the technical and clinical performance of the Elecsys S100 electrochemiluminescence immunoassay and to assess its utility as a tumor marker in patients with malignant melanoma. Imprecision studies yielded within-run coefficients of variation (CVs) of 0.7-2.0% and betwe...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章,多中心研究

    doi:10.1515/CCLM.2005.097

    authors: Alber B,Hein R,Garbe C,Caroli U,Luppa PB

    更新日期:2005-01-01 00:00:00

  • Comparison of standard PCR and the LightCycler technique to determine the thrombophilic mutations: an efficiency and cost study.

    abstract::For several years it has been possible to routinely detect numerous mutations in the human genome by different methods. The most common technique is a standard PCR, but real time fluorescence PCR is increasingly being used. The purpose of this paper is to compare these two different techniques from the point of view o...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2003.072

    authors: Schroell-Metzger B,Dicato M,Bosseler M,Berchem G

    更新日期:2003-04-01 00:00:00

  • Pancreatic phospholipase A2 activity in acute pancreatitis: a prognostic marker for early identification of patients at risk.

    abstract::Remarkably elevated levels of phospholipase A2 (PLA2) are measurable in human blood samples in cases of acute pancreatitis. The source of the enzyme was first thought to be exclusively the pancreas, but now it is generally accepted that two isoenzymes--the pancreatic PLA2, group I, and the extrapancreatic PLA2, group ...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2002.046

    authors: Aufenanger J,Samman M,Quintel M,Fassbender K,Zimmer W,Bertsch T

    更新日期:2002-03-01 00:00:00

  • Performance analysis of the ARCHITECT anti-cyclic citrullinated peptide antibody in the diagnosis of rheumatoid arthritis.

    abstract:BACKGROUND:Anti-cyclic citrullinated peptide (CCP) antibody is emerging as an important diagnostic marker for rheumatoid arthritis (RA). We evaluated the analytical and diagnostic performance of the ARCHITECT anti-CCP (Abbott Diagnostics), a new fully automated chemiluminescent microparticle immunoassay. METHODS:Serum...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2010.046

    authors: Hwang SM,Kim JO,Yoo YM,Shin S,Kim JQ,Park MH,Song EY

    更新日期:2010-02-01 00:00:00

  • Haemoglobin A1c: analysis and standardisation.

    abstract::The measurement of glycated haemoglobin has become centrally important in the monitoring of glycaemic control in the patient with diabetes. A number of analytical techniques have been described to measure this important haemoglobin fraction, and the fraction measured depends on the technique used; this has resulted in...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 历史文章,杂志文章

    doi:10.1515/CCLM.2003.184

    authors: John WG

    更新日期:2003-09-01 00:00:00

  • A family with multiple mutations and sequence variations in the alpha- and beta-globin gene clusters.

    abstract:BACKGROUND:Usually, laboratory diagnostics of hereditary hemoglobin disorders is fairly straightforward. Sometimes, however, correct diagnosis can be difficult. In this study, we describe a family with multiple mutations and sequence variations in the alpha- and beta-globin gene clusters. METHODS:Hemocytometry results...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2008.037

    authors: de Vooght KM,van Wijk R,Rijksen G,van Solinge WW

    更新日期:2008-01-01 00:00:00

  • Evaluation of analytical performance of the Pathfast cardiac troponin I.

    abstract:BACKGROUND:Cardiac troponins are considered the cornerstone for risk stratification and diagnosis of patients with acute coronary syndrome (ACS). Following Clinical Laboratory Standards Institute (CLSI) guidelines, we assessed the analytical performances of the Pathfast (Mitsubishi, Japan) cTnI method. METHODS:We eval...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2009.182

    authors: Di Serio F,Caputo M,Zaninotto M,Ottomano C,Plebani M

    更新日期:2009-01-01 00:00:00

  • Effects of high-dose, intravenous lipid emulsion on laboratory tests in humans: a randomized, placebo-controlled, double-blind, clinical crossover trial.

    abstract::Background Intravenous lipid emulsion (ILE) is used to treat drug poisonings. The resultant hyperlipemia may affect laboratory tests but the consequences are poorly characterized. In a clinical trial we therefore investigated the effects of ILE on laboratory tests analyzed on common analytical platforms (Roche® cobas ...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章,随机对照试验

    doi:10.1515/cclm-2018-0430

    authors: Petersen KM,Jørgensen NR,Bøgevig S,Petersen TS,Jensen TB,Dalhoff KP,Christensen MB

    更新日期:2018-11-27 00:00:00

  • Clinical application of a dried blood spot assay for sirolimus and everolimus in transplant patients.

    abstract::Background Monitoring of immunosuppressive drugs such as everolimus and sirolimus is important in allograft rejection prevention in transplant patients. Dried blood spots (DBS) sampling gives patients the opportunity to sample a drop of blood from a fingerprick at home, which can be sent to the laboratory by mail. Met...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2019-0053

    authors: Veenhof H,Koster RA,Alffenaar JC,van den Berg AP,de Groot MR,Verschuuren EAM,Berger SP,Bakker SJL,Touw DJ

    更新日期:2019-11-26 00:00:00

  • European multicenter analytical evaluation of the Abbott ARCHITECT STAT high sensitive troponin I immunoassay.

    abstract:BACKGROUND:International recommendations highlight the superior value of cardiac troponins (cTns) for early diagnosis of myocardial infarction along with analytical requirements of improved precision and detectability. In this multicenter study, we investigated the analytical performance of a new high sensitive cardiac...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章,多中心研究

    doi:10.1515/cclm-2014-0107

    authors: Krintus M,Kozinski M,Boudry P,Capell NE,Köller U,Lackner K,Lefèvre G,Lennartz L,Lotz J,Herranz AM,Nybo M,Plebani M,Sandberg MB,Schratzberger W,Shih J,Skadberg Ø,Chargui AT,Zaninotto M,Sypniewska G

    更新日期:2014-11-01 00:00:00

  • Hyperhomocysteinemia and high-density lipoprotein metabolism in cardiovascular disease.

    abstract::Hyperhomocysteinemia (HHcy) is a significant and independent risk factor for cardiovascular disease (CVD) and the underlying mechanism is unclear. We and others have reported that homocysteine (Hcy) is inversely correlated with plasma high-density lipoprotein cholesterol (HDL-C) and apolipoprotein AI (apoA-I) in patie...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章,评审

    doi:10.1515/CCLM.2007.358

    authors: Liao D,Yang X,Wang H

    更新日期:2007-01-01 00:00:00

  • Thrombophilia screening--at the right time, for the right patient, with a good reason.

    abstract::Thrombophilia can be identified in about half of all patients presenting with venous thromboembolism (VTE). Thrombophilia screening for various indications has increased tremendously, but whether the results of such tests help in the clinical management of patients is uncertain. Here, current recommendations for throm...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章,评审

    doi:10.1515/CCLM.2010.367

    authors: Stegnar M

    更新日期:2010-12-01 00:00:00

  • Amniotic fibronectin fragmentation and expression of its domains, sialyl and fucosyl glycotopes associated with pregnancy complicated by intrauterine infection.

    abstract:BACKGROUND:The presence of fibronectin fragments has been observed in some inflammatory diseases and is believed to reflect tissue breakdown. In this study, possible fibronectin fragmentation and alterations in its domain and sialyl and fucosyl glycotope expressions were analyzed in amniotic fluids in relation to intra...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2007.041

    authors: Hirnle L,Katnik-Prastowska I

    更新日期:2007-01-01 00:00:00

  • Skin aging by glycation: lessons from the reconstructed skin model.

    abstract:BACKGROUND:Aging is the result of several mechanisms which operate simultaneously. Among them, glycation is of particular interest because it is a reaction which affects slowly renewing tissues and macromolecules with elevated half-life, like the dermis, a skin compartment highly affected by aging. Glycation produces c...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2013-0091

    authors: Pageon H,Zucchi H,Rousset F,Monnier VM,Asselineau D

    更新日期:2014-01-01 00:00:00

  • Performance characteristics of a microfluidic Lab-on-Chip electrophoresis system for high-density lipoprotein (HDL) subfraction separation and measurement.

    abstract:BACKGROUND:High-density lipoprotein (HDL) is believed to be protective against coronary heart disease (CHD). HDL is comprised of different subfractions. Of these, HDL 2b is believed to be the most important in preventing CHD. Current methods for HDL subfraction measurements are not standardized and often exhibit poor a...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2010.133

    authors: Yang DH,Konigshofer Y,Dike J,Chang E,Mueller O

    更新日期:2010-06-01 00:00:00

  • A patient with AL amyloidosis with negative free light chain results.

    abstract::The detection and quantification of amyloidogenic monoclonal light chains are necessary for the diagnosis and evaluation of response to treatment in AL amyloidosis. However, the amyloid clone is often small and difficult to detect. We report the case of a 68-year-old man who was referred to our Center in April 2013 af...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2015-0847

    authors: Milani P,Valentini V,Ferraro G,Basset M,Russo F,Foli A,Palladini G,Merlini G

    更新日期:2016-06-01 00:00:00

  • Novel haptoglobin insertion/deletion polymorphism is associated with the lipid profile and C-reactive protein (CRP) concentration.

    abstract::We discovered a hitherto undescribed insertion/deletion (I/D) polymorphism of 7 base pairs in intron 4 of the HP1 allele and intron 4 and 6 of the HP2 allele. Genotyping was performed in 311 Belgian subjects. The association between serum haptoglobin (Hp) and lipid concentrations and the Hp I/D genotypes was investiga...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2002.081

    authors: Wuyts B,Hetet G,Grandchamp B,Delanghe JR

    更新日期:2002-05-01 00:00:00

  • Are the currently used reference intervals for creatine kinase (CK) reflecting the general population? The Tromsø Study.

    abstract:BACKGROUND:Laboratory reference intervals are not necessarily reflecting the range in the background population. This study compared creatine kinase (CK) reference intervals calculated from a large sample from a Norwegian population with those elaborated by the Nordic Reference Interval Project (NORIP). It also assesse...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2011.776

    authors: Lilleng H,Johnsen SH,Wilsgaard T,Bekkelund SI

    更新日期:2011-11-10 00:00:00

  • Instability of cerebrospinal fluid after delayed storage and repeated freezing: a holistic study by drop coating deposition Raman spectroscopy.

    abstract:BACKGROUND:The handling of cerebrospinal fluid (CSF) affects the biomarker quantification used to diagnose Alzheimer's disease (AD). Only specialized centers can test for AD markers. The precise timing and freezing is required to correctly measure these biomarkers. Therefore, the effects of CSF storage temperature and ...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2013-0800

    authors: Klener J,Hofbauerová K,Bartoš A,Ríčný J,Rípová D,Kopecký V

    更新日期:2014-05-01 00:00:00

  • A two-step method for the extraction of high-quality RNA from endoscopic biopsies.

    abstract::The use of molecular techniques such as quantitative RT-PCR depends on the quality of cellular RNA. In particular, RNA extraction from endoscopic biopsies is difficult with respect to yield, and especially integrity. Endoscopic biopsies taken from the gastric antrum, corpus and duodenum were subjected to various RNA e...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2003.159

    authors: Wex T,Treiber G,Lendeckel U,Malfertheiner P

    更新日期:2003-08-01 00:00:00

  • Towards harmonization of external quality assessment/proficiency testing in hemostasis.

    abstract::Quality in diagnostic testing represents a key target of laboratory medicine, for which an assurance around the quality of testing is expected from all involved in the process. Laboratories attempt to assure the quality of their testing by various processes, but especially by performance of internal quality control an...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2018-0077

    authors: Favaloro EJ,Jennings I,Olson J,Van Cott EM,Bonar R,Gosselin R,Meijer P

    更新日期:2018-12-19 00:00:00

  • Reference intervals for thyroid hormones on the architect analyser.

    abstract::The objective of this study was to establish reference intervals for thyroid stimulating hormone (TSH), free thyroxine (FT4), free triiodothyronine (FT3), total thyronine (TT4) and total triiodothyronine (TT3) on the Architect i2000 analyser (Abbott). Serum samples were obtained from apparently healthy adults (n=217, ...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2002.028

    authors: Hubl W,Schmieder J,Gladrow E,Demant T

    更新日期:2002-02-01 00:00:00

  • Biological variation and quantification of health: the emergence of the concept of normality.

    abstract::Historical research on the concept of normality, its roots and its development show that this concept has its sources in very different areas of scientific and medical thinking. Of great importance were: (i) a new theory of disease arising early in the 19th century supposing a continuous change from the healthy to the...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 历史文章,杂志文章

    doi:10.1515/CCLM.1998.013

    authors: Büttner J

    更新日期:1998-01-01 00:00:00

  • Reference values for plasma dipeptidyl-peptidase IV activity and their association with other laboratory parameters.

    abstract::In blood, the exopeptidase dipeptidyl-peptidase IV (DPPIV; EC 3.4.14.5) is predominantly present in a soluble form in plasma/serum and as an activation antigen on the membrane of lymphocytes (CD26). It modifies some important biologically active peptides (neuropeptides, chemokines), and a regulatory role for DPPIV/CD2...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2001.026

    authors: Durinx C,Neels H,Van der Auwera JC,Naelaerts K,Scharpe S,De Meester I

    更新日期:2001-02-01 00:00:00

  • The 3rd International Standard for serum IgE: international collaborative study to evaluate a candidate preparation.

    abstract:BACKGROUND:The measurement of serum IgE aids in the diagnosis and management of atopic allergic disease and hyper-IgE immunodeficiency syndromes. The 2nd World Health Organization (WHO) International Reference Reagent (IRR) for serum IgE (75/502; 5000 IU/ampoule), is widely used to calibrate assays for serum IgE. Exhau...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2014-0243

    authors: Thorpe SJ,Heath A,Fox B,Patel D,Egner W

    更新日期:2014-09-01 00:00:00

  • Standardization of DiaSorin and Roche automated third generation PTH assays with an International Standard: impact on clinical populations.

    abstract:BACKGROUND:Standardization of parathyroid hormone (PTH) assays is a major issue, especially in hemodialyzed (HD) patients. Two automated third generation PTH assays (Roche Elecsys and DiaSorin Liaison) are now available. These assays are specific for the (1-84) PTH and do not cross-react with the (7-84) fragment, contr...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2013-1027

    authors: Cavalier E,Delanaye P,Lukas P,Carlisi A,Gadisseur R,Souberbielle JC

    更新日期:2014-08-01 00:00:00

  • Experience with post-market surveillance of in-vitro diagnostic medical devices for lay use in Germany.

    abstract:BACKGROUND:The European Directive 98/79/EC on in-vitro diagnostic medical devices (IVDs) regulates IVD marketing practices and post-market surveillance. IVD manufacturers have to inform the responsible Competent Authorities of any issues. In Germany, the Federal Institute for Drugs and Medical Devices (BfArM) is respon...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2007.058

    authors: Siekmeier R,Lütz J

    更新日期:2007-01-01 00:00:00