Towards harmonization of external quality assessment/proficiency testing in hemostasis.

Abstract:

:Quality in diagnostic testing represents a key target of laboratory medicine, for which an assurance around the quality of testing is expected from all involved in the process. Laboratories attempt to assure the quality of their testing by various processes, but especially by performance of internal quality control and external quality assessment (EQA). This is especially true for tests of hemostasis and coagulation. EQA in general provides information on test accuracy and on evaluation of long-term laboratory performance. EQA providers support laboratory performance by various means, including distribution of material for testing of analytes ("proficiency testing"), educational support through expert advice, distribution of publications or case series. Participation in EQA is often a laboratory accreditation requirement. This review aims to identify some of the strengths and weaknesses of EQA, and targets attempts towards harmonization of EQA practice, in order to achieve the best outcome for participant laboratories and, thus, for patients and their clinical care providers.

journal_name

Clin Chem Lab Med

authors

Favaloro EJ,Jennings I,Olson J,Van Cott EM,Bonar R,Gosselin R,Meijer P

doi

10.1515/cclm-2018-0077

subject

Has Abstract

pub_date

2018-12-19 00:00:00

pages

115-126

issue

1

eissn

1434-6621

issn

1437-4331

pii

/j/cclm.ahead-of-print/cclm-2018-0077/cclm-2018-00

journal_volume

57

pub_type

杂志文章
  • Standards of practice and uniformity in references style.

    abstract::Authors are usually invited to follow the instructions to authors in scientific journals, because this section is likely to contain unique requirements, such as the references style requested. Authors not only must accurately check the instructions, but are also expected to verify references against the original docum...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2008.114

    authors: Salvagno GL,Lippi G,Montagnana M,Guidi GC

    更新日期:2008-01-01 00:00:00

  • Activity or mass concentration of bone-specific alkaline phosphatase as a marker of bone formation.

    abstract:BACKGROUND:Recently published data identified bone-specific alkaline phosphatase (BALP) as a good marker of bone formation in different bone diseases and osteoporosis. Two methods are available for BALP determination: one measures enzyme activity, the other its mass concentration. We compared results for BALP activity ...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2007.186

    authors: Avbersek-Luznik I,Gmeiner Stopar T,Marc J

    更新日期:2007-01-01 00:00:00

  • The influence of radiation and chemotherapy-related DNA strand breaks on carcinogenesis: an evaluation.

    abstract:PURPOSE:DNA strand breaks are believed to induce carcinogenesis. This study was conducted to analyze induction and repair of irradiation- and chemotherapy-related strand breaks in vitro. METHODS:Friend Leukemia cells were exposed to irradiation and various chemotherapeutic agents at different doses and concentrations....

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.1999.066

    authors: Froelich JJ,Schneller FR,Zahn RK

    更新日期:1999-04-01 00:00:00

  • Combining antibody tests and taking into account antibody levels improves serologic diagnosis of celiac disease.

    abstract:BACKGROUND:The European Society for Pediatric Gastroenterology and Nutrition states that if IgA anti-tissue transglutaminase (tTG) exceeds 10 times the upper limit of normal (ULN), there is the possibility to diagnose celiac disease (CD) without duodenal biopsy, if supported by anti-endomysium testing and human leukocy...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2013-1099

    authors: Oyaert M,Vermeersch P,De Hertogh G,Hiele M,Vandeputte N,Hoffman I,Bossuyt X

    更新日期:2015-09-01 00:00:00

  • Continuous analysis in extracorporeally circulating blood--a rat model applying flow-through ion-selective electrodes for the measurement of Ca2+, K+, Na+ and pH.

    abstract::A rat model is introduced which enables investigations in anticoagulated blood with continuous measurements by a flow-through electrode system. In the present study, a potentiometric ion-selective electrode (ISE)-system was used for measuring Ca2+, K+, Na+ and pH in rats. The setup was adjusted to an extracorporeal bl...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.1998.149

    authors: Heidrich JP,Niemeier A,Seyfarth M

    更新日期:1998-11-01 00:00:00

  • Rifampicin causes false-positive immunoassay results for urine opiates.

    abstract::The treatment of tuberculosis usually includes the antibiotic rifampicin, especially in patients with concomitant human immunodeficiency virus infection. Some of these patients are in withdrawal therapy for drug abuse. When opiate screening is carried out in patients receiving rifampicin, false positive results are de...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.1998.041

    authors: de Paula M,Saiz LC,González-Revaldería J,Pascual T,Alberola C,Miravalles E

    更新日期:1998-04-01 00:00:00

  • Lipoprotein lipase gene polymorphisms in Croatian patients with coronary artery disease.

    abstract::Modifications in lipoprotein lipase levels lead to elevated triglycerides and reduced high density lipoprotein (HDL), both of which are risk factors for coronary artery disease (CAD). Hence, we examined the influence of the -93T/G, D9N, N291S, and S447X polymorphisms in the lipoprotein lipase (LPL) gene on CAD risk an...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2003.082

    authors: Ferencak G,Pasalić D,Grsković B,Cheng S,Fijal B,Sesto M,Skodlar J,Rukavina AS

    更新日期:2003-04-01 00:00:00

  • Comparability of five analytical systems for the determination of triiodothyronine, thyroxine and thyroid-stimulating hormone.

    abstract:BACKGROUND:The purpose of an external quality assessment (EQA) is to evaluate the analytical capability of clinical laboratories, identify differences among the laboratories and improve analytical quality. Our EQA results show that the rates of unsatisfactory performance for thyroid hormone tests were the highest in al...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2006.251

    authors: Zhou Q,Li S,Li X,Wang W,Wang Z

    更新日期:2006-01-01 00:00:00

  • Comparison of methods for calculating serum osmolality: multivariate linear regression analysis.

    abstract:BACKGROUND:There are several methods for calculating serum osmolality, and their accordance with measured osmolality is the subject of controversy. METHODS:The concentrations of sodium, potassium, glucose, blood urea nitrogen (BUN) and osmolalities of 210 serum samples were measured. Two empirical equations were deduc...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2005.109

    authors: Rasouli M,Kalantari KR

    更新日期:2005-01-01 00:00:00

  • Thrombophilia screening--at the right time, for the right patient, with a good reason.

    abstract::Thrombophilia can be identified in about half of all patients presenting with venous thromboembolism (VTE). Thrombophilia screening for various indications has increased tremendously, but whether the results of such tests help in the clinical management of patients is uncertain. Here, current recommendations for throm...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章,评审

    doi:10.1515/CCLM.2010.367

    authors: Stegnar M

    更新日期:2010-12-01 00:00:00

  • Performance evaluation of an Indoxyl Sulfate Assay Kit "NIPRO".

    abstract::Background The relationship between renal disease and cardiovascular disease (CVD) is currently known as cardiorenal syndrome. Indoxyl sulfate (IS) is one of the uremic toxins that accelerates the progression of cardiorenal syndrome. This report presents a new method for measuring IS in a simpler way. Methods We evalu...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2019-0218

    authors: Fushimi Y,Tatebe J,Okuda Y,Ishii T,Ujiie S,Morita T

    更新日期:2019-10-25 00:00:00

  • Serum levels of matrix metalloproteinase-2 and -9 and conventional tumor markers (CEA and CA 19-9) in patients with colorectal and gastric cancers.

    abstract:BACKGROUND:Matrix metalloproteinases (MMPs), especially MMP-2 and MMP-9, play an important role in tumor invasion and metastasis. This study aimed to determine the serum levels of MMP-2, MMP-9, 130- and 225-kDa gelatinolytic bands and conventional tumor markers, carcinoembryonic antigen (CEA) and cancer antigen (CA) 19...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2009.212

    authors: Emara M,Cheung PY,Grabowski K,Sawicki G,Wozniak M

    更新日期:2009-01-01 00:00:00

  • Laboratory approaches for predicting and managing the risk of cardiovascular disease: postanalytical opportunities of lipid and lipoprotein testing.

    abstract::Abstract Lipoprotein-related risk of cardiovascular disease (CVD) can be adequately predicted in subjects with elevated total cholesterol and low-density lipoprotein (LDL-)cholesterol using the available guidelines. However, individuals with dyslipidemia can have normal total- and LDL-cholesterol concentrations. Many ...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章,评审

    doi:10.1515/cclm-2011-0636

    authors: Langlois MR

    更新日期:2012-04-10 00:00:00

  • Newborn screening for haemoglobinopathies by high performance liquid chromatography (HPLC): diagnostic utility of different approaches in resource-poor settings.

    abstract:BACKGROUND:Sickle cell disease is a major health burden in India. The aim of the study was to compare the diagnostic utility of two different approaches on automated high performance liquid chromatography (HPLC) for newborn screening for sickle cell disorders and other haemoglobinopathies in India. METHODS:Newborn bab...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2014-0452

    authors: Upadhye DS,Jain DL,Trivedi YL,Nadkarni AH,Ghosh K,Colah RB

    更新日期:2014-12-01 00:00:00

  • Customer satisfaction survey to improve the European cystic fibrosis external quality assessment scheme.

    abstract:BACKGROUND:The Cystic Fibrosis European Network, coordinated from within the Katholieke Universiteit Leuven, is the provider of the European cystic fibrosis external quality assessment (EQA) scheme. The network aimed to seek feedback from laboratories that participated in the cystic fibrosis scheme in order to improve ...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2011.215

    authors: Berwouts S,Dequeker E

    更新日期:2011-08-01 00:00:00

  • Evaluation of a novel extended automated particle-based multi-analyte assay for the detection of autoantibodies in the diagnosis of primary biliary cholangitis.

    abstract:Background:Anti-mitochondrial autoantibodies (AMA) detected by indirect immunofluorescence (IIF) on rodent tissues are the diagnostic marker of primary biliary cholangitis (PBC). However, up to 15% of patients with PBC are AMA-negative by IIF. In the effort to close the serological gap and improve the diagnostic sensit...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2020-0122

    authors: Villalta D,Seaman A,Tiongson M,Warren C,Bentow C,Bizzaro N,Alessio MG,Porcelli B,Norman GL,Mahler M

    更新日期:2020-04-10 00:00:00

  • An International Standard for whole blood folate: evaluation of a lyophilised haemolysate in an international collaborative study.

    abstract::Folate measurements, particularly for whole blood, show wide inter-laboratory and inter-methodology variability. This variability appears to be due in part to the lack of internationally accepted reference materials. A whole blood haemolysate, lyophilised in ampoules and designated 95/528, was therefore evaluated by 1...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2004.090

    authors: Thorpe SJ,Sands D,Heath AB,Hamilton MS,Blackmore S,Barrowcliffe T

    更新日期:2004-05-01 00:00:00

  • Precision performance at low levels and 99th percentile concentration of the Access AccuTnl assay on two different platforms.

    abstract:BACKGROUND:Cardiac troponins currently represent the preferred biomarkers for the detection of myocardial necrosis. The objective of the present study was to compare the performance of the Access AccuTnl assay (Beckman Coulter) measured on two different platforms, the UniCel Dxl 800 and the Access 2 (Beckman Coulter). ...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm.2009.080

    authors: Zaninotto M,Mion MM,Novello E,Moretti M,Delprete E,Rocchi MB,Sisti D,Plebani M

    更新日期:2009-01-01 00:00:00

  • Rheumatoid factor interference in the determination of carbohydrate antigen 19-9 (CA 19-9).

    abstract:BACKGROUND:Investigation of a 61-year-old Caucasian male suffering from fatigue and weight loss led to the finding of a carbohydrate antigen 19-9 (CA 19-9) concentration of 80 kU/L using an ADVIA Centaur analyser. Determination of CA 19-9 on Vidas, AxSYM and Architect i2000 systems gave normal results. His rheumatoid f...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2006.205

    authors: Berth M,Bosmans E,Everaert J,Dierick J,Schiettecatte J,Anckaert E,Delanghe J

    更新日期:2006-01-01 00:00:00

  • Matrix effects in clinical immunoassays and the effect of preheating and cooling analytical samples.

    abstract::Immunological reactions are influenced by various factors including antigens, antibodies and other variables. We focused on two items: i) matrix effects, especially of detergents and ii) temperature effects: preheating sera, especially effects on rheumatoid factor (RF) measurement and false-positive reactions in ELISA...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2004.010

    authors: Yoshida H,Imafuku Y,Nagai T

    更新日期:2004-01-01 00:00:00

  • Nitration of human plasminogen by RAW 264.7 macrophages reduces streptokinase-induced plasmin activity.

    abstract::Despite many years of study, clinical trials of new drugs to prevent thrombosis have often been disappointing. Part of the problem lies in our incomplete understanding of the regulation of plasminogen activation and/or inhibition in vivo. We have previously shown that in vitro nitration of plasminogen in plasma by per...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2006.039

    authors: Hathuc C,Hermo R,Schulze J,Gugliucci A

    更新日期:2006-01-01 00:00:00

  • A patient with AL amyloidosis with negative free light chain results.

    abstract::The detection and quantification of amyloidogenic monoclonal light chains are necessary for the diagnosis and evaluation of response to treatment in AL amyloidosis. However, the amyloid clone is often small and difficult to detect. We report the case of a 68-year-old man who was referred to our Center in April 2013 af...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2015-0847

    authors: Milani P,Valentini V,Ferraro G,Basset M,Russo F,Foli A,Palladini G,Merlini G

    更新日期:2016-06-01 00:00:00

  • Clinical prognostic value of CD4+CD25+FOXP3+regulatory T cells in peripheral blood of Barcelona Clinic Liver Cancer (BCLC) stage B hepatocellular carcinoma patients.

    abstract:BACKGROUND:CD4+CD25+ forkhead box P3 (FOXP3)+ regulatory T cells (Tregs) accumulate in malignant tumors and negatively regulate antitumor immunity. However, the clinical significance of Tregs in HCC remains unclear. To determine the prognostic value of Tregs, we conducted a retrospective study on 264 patients with Barc...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2013-0878

    authors: Li F,Guo Z,Lizée G,Yu H,Wang H,Si T

    更新日期:2014-09-01 00:00:00

  • Total iron binding capacity and transferrin concentration in the assessment of iron status.

    abstract::Transferrin concentration and total iron binding capacity (TIBC) are currently used to assess iron status. Although correlation between TIBC and transferrin is generally considered as good, conversion factors between the two analytes found in literature show large differences. Although the price per test is lower for ...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章,评审

    doi:10.1515/CCLM.2002.176

    authors: Kasvosve I,Delanghe J

    更新日期:2002-10-01 00:00:00

  • A laboratory-based risk score for medical intensive care patients.

    abstract:BACKGROUND:Established general risk score models for intensive care patients incorporate several clinical and laboratory data. However, the collection, documentation and classification of clinical data are time-consuming, incur labor-related costs, and are dependent on the experience of the examiner. Therefore, in the ...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2008.136

    authors: Stachon A,Segbers E,Hering S,Kempf R,Holland-Letz T,Krieg M

    更新日期:2008-01-01 00:00:00

  • Permissible performance limits of regression analyses in method comparisons.

    abstract::Method comparisons are indispensable tools for the extensive validation of analytic procedures. Laboratories often only want to know whether an established procedure (x-method) can be replaced by another one (y-method) without interfering with diagnostic purposes. Then split patients' samples are analyzed more or less...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2011.668

    authors: Haeckel R,Wosniok W,Al Shareef N

    更新日期:2011-11-01 00:00:00

  • Clinical relevance of circulating midkine in ulcerative colitis.

    abstract:BACKGROUND:Non-invasive biochemical markers are needed to support the diagnosis of ulcerative colitis (UC), an incurable disease of unknown pathology. Midkine is an angiogenic cytokine, chemotactic towards neutrophils and macrophages, and a T-regulatory cell suppressor. METHODS:Serum midkine was measured immunoenzymat...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2009.248

    authors: Krzystek-Korpacka M,Neubauer K,Matusiewicz M

    更新日期:2009-01-01 00:00:00

  • A systematic evaluation of stool DNA preparation protocols for colorectal cancer screening via analysis of DNA methylation biomarkers.

    abstract:Objectives:Colorectal cancer (CRC) screening using stool samples is now in routine use where tumor DNA methylation analysis for leading markers such as NDRG4 and SDC2 is an integral part of the test. However, processing stool samples for reproducible and efficient extraction of human genomic DNA remains a bottleneck fo...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2020-0300

    authors: Jin S,Ye Q,Hong Y,Dai W,Zhang C,Liu W,Guo Y,Zhu D,Zhang Z,Chen S,Wang Y,Li D,Ma W,Yang Z,Li J,Zheng Z,Luan J,Wu X,Jiang F,Xu C,Ding C

    更新日期:2020-07-16 00:00:00

  • Performance of automated digital cell imaging analyzer Sysmex DI-60.

    abstract:BACKGROUND:The Sysmex DI-60 system (DI-60, Sysmex, Kobe, Japan) is a new automated digital cell imaging analyzer. We explored the performance of DI-60 in comparison with Sysmex XN analyzer (XN, Sysmex) and manual count. METHODS:In a total of 276 samples (176 abnormal and 100 normal samples), white blood cell (WBC) dif...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2017-0132

    authors: Kim HN,Hur M,Kim H,Kim SW,Moon HW,Yun YM

    更新日期:2017-11-27 00:00:00

  • Apolipoprotein E polymorphism--a risk factor for metabolic syndrome.

    abstract:BACKGROUND:Metabolic syndrome is closely related to several disturbances in lipid and lipoprotein metabolism. The aim of this study was to determine the association between apolipoprotein E (apoE) genotypes and the risk of metabolic syndrome and/or coronary heart disease complications. METHODS:The study included 279 s...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2007.258

    authors: Sima A,Iordan A,Stancu C