Standardization of DiaSorin and Roche automated third generation PTH assays with an International Standard: impact on clinical populations.

Abstract:

BACKGROUND:Standardization of parathyroid hormone (PTH) assays is a major issue, especially in hemodialyzed (HD) patients. Two automated third generation PTH assays (Roche Elecsys and DiaSorin Liaison) are now available. These assays are specific for the (1-84) PTH and do not cross-react with the (7-84) fragment, contrary to second generation (intact) assays. We aimed to calibrate the two methods against the WHO International PTH Standard (IS) 95/646 to see if the two assays could provide comparable results in a population of healthy subjects, HD patients and patients suffering from primary hyperparathyroidism (PHP). METHODS:We selected 79 healthy subjects and two populations of patients presenting PTH disorders: 56 HD and 27 PHP patients. We reconstituted the IS in a pool of human serum containing undetectable levels of 1-84 PTH and prepared 13 serum standards ranging from 0 to 2000 pg/mL. The standards were run on the two instruments to calibrate the assays on the IS. The different populations were run before and after restandardization. RESULTS:As these kits were differently calibrated, the results obtained after restandarization were significantly different. Restandardization process improved concordance between assays and, taking the analytical variability of the two kits into account, the results could be considered to be similar. CONCLUSIONS:Restandardization of automated third generation PTH assays with the WHO 1-84 PTH Standard significantly reduces inter-method variability. Reference ranges and raw values are totally transposable from one method to the other in healthy subjects, but also in diseased patients, e.g., with HD or those suffering from PHP.

journal_name

Clin Chem Lab Med

authors

Cavalier E,Delanaye P,Lukas P,Carlisi A,Gadisseur R,Souberbielle JC

doi

10.1515/cclm-2013-1027

subject

Has Abstract

pub_date

2014-08-01 00:00:00

pages

1137-41

issue

8

eissn

1434-6621

issn

1437-4331

pii

/j/cclm.ahead-of-print/cclm-2013-1027/cclm-2013-10

journal_volume

52

pub_type

杂志文章
  • Laboratory performance of sweat conductivity for the screening of cystic fibrosis.

    abstract:BACKGROUND:There are several complementary English-language guidelines for the performance of the sweat chloride test. These guidelines also incorporate information for the collection of conductivity samples. However, recommendations for the measurement and reporting of sweat conductivity are less clear than for sweat ...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2017-0530

    authors: Greaves RF,Jolly L,Massie J,Scott S,Wiley VC,Metz MP,Mackay RJ,Australasian Association of Clinical Biochemists Sweat Test Working Party in association with the Royal Australasian College of Pathologists Quality Assurance Programs.

    更新日期:2018-03-28 00:00:00

  • Evaluation of clinical cases in External Quality Assessment Scheme (EQAS) for the urinary sediment.

    abstract:BACKGROUND:The few available External Quality Assessment (EQA) programs on urinary sediment rarely include an evaluation of clinical cases. The present paper provides a descriptive analysis of clinical cases included in the Italian EQA program on urinary sediment. METHODS:Ten cases were presented over a 5-year period ...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2013-0785

    authors: Fogazzi GB,Secchiero S,Garigali G,Plebani M

    更新日期:2014-06-01 00:00:00

  • Use of a fully automated immunoassay for celiac disease screening in a pediatric population.

    abstract:BACKGROUND:Celiac disease (CD) is an immune-mediated disorder of the small bowel in which gluten and related cereal ingestion leads to chronic inflammation and damage to the small bowel mucosa in genetically susceptible individuals. The presence of IgA type tissue-transglutaminase antibodies (IgA-anti-tTG) in individua...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2011.164

    authors: Ress K,Harro J,Uibo O,Uibo R

    更新日期:2011-06-01 00:00:00

  • Is the association of serum lipase with beta2-microglobulin or C-reactive protein useful for establishing the diagnosis and prognosis of patients with acute pancreatitis?

    abstract::In the Emergency Department it is mandatory to establish the diagnosis and the prognosis of acute pancreatitis as soon as possible. To evaluate whether the association of serum lipase either with serum beta2-microglobulin or with C-reactive protein allows simultaneously to establish the diagnosis and the prognosis of ...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 临床试验,杂志文章

    doi:10.1515/CCLM.1998.166

    authors: Pezzilli R,Morselli-Labate AM,Barakat B,Fiocchi M,Cappelletti O

    更新日期:1998-12-01 00:00:00

  • An International Standard for whole blood folate: evaluation of a lyophilised haemolysate in an international collaborative study.

    abstract::Folate measurements, particularly for whole blood, show wide inter-laboratory and inter-methodology variability. This variability appears to be due in part to the lack of internationally accepted reference materials. A whole blood haemolysate, lyophilised in ampoules and designated 95/528, was therefore evaluated by 1...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2004.090

    authors: Thorpe SJ,Sands D,Heath AB,Hamilton MS,Blackmore S,Barrowcliffe T

    更新日期:2004-05-01 00:00:00

  • Lactase persistence genotyping: rapid detection of seven sequence variants in a single tube with melting curve analyses.

    abstract:BACKGROUND:Lactase persistence is an inherited autosomal dominant trait that confers the ability to digest lactose after weaning. Lactose persistence is caused by single nucleotide variants in a regulatory element for the lactase gene (LCT). In Europeans, lactase persistence is associated with the nucleotide variant LC...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2014-0123

    authors: Strand H,Sørensen LK,Ingebretsen OC

    更新日期:2014-09-01 00:00:00

  • Mid-stream vs. first-voided urine collection by using automated analyzers for particle examination in healthy subjects: an Italian multicenter study.

    abstract:BACKGROUND:In analogy with other areas of laboratory diagnostics, the pre-analytical phase is the leading source of variability also in urinalysis. We carried out a multicentric study for comparing results obtained from first-voided and mid-stream urine samples. METHODS:Each of the six hospital-based clinical laborato...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章,多中心研究

    doi:10.1515/cclm.2011.823

    authors: Manoni F,Gessoni G,Alessio MG,Caleffi A,Saccani G,Silvestri MG,Poz D,Ercolin M,Tinello A,Valverde S,Ottomano C,Lippi G

    更新日期:2011-12-20 00:00:00

  • Diagnosis biomarkers in acute intestinal ischemic injury: so close, yet so far.

    abstract::Acute intestinal ischemic injury (i3) is a life-threatening condition with disastrous prognosis, which is currently difficult to diagnose at the early stages of the disease; a rapid diagnosis is mandatory to avoid irreversible ischemia, extensive bowel resection, sepsis and death. The overlapping protein expression of...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章,评审

    doi:10.1515/cclm-2017-0291

    authors: Peoc'h K,Nuzzo A,Guedj K,Paugam C,Corcos O

    更新日期:2018-02-23 00:00:00

  • Comparison of procalcitonin, sCD14 and interleukin-6 values in septic patients.

    abstract::The aim of the study was to investigate whether procalcitonin, soluble CD14 and interleukin-6 show advantages in predicting the outcome and specificity for bacterial infection in patients with sepsis in comparison to common C-reactive protein measurement. Laboratory parameters were measured in plasma of patients durin...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2000.007

    authors: Herrmann W,Ecker D,Quast S,Klieden M,Rose S,Marzi I

    更新日期:2000-01-01 00:00:00

  • The correlation between glucose fluctuation from self-monitored blood glucose and the major adverse cardiac events in diabetic patients with acute coronary syndrome during a 6-month follow-up by WeChat application.

    abstract::Background This study aimed to investigate the correlation between glucose fluctuation from self-monitored blood glucose (SMBG) and the major adverse cardiac events (MACE) in diabetic patients with acute coronary syndrome (ACS) during a 6-month follow-up period using the WeChat application. Methods From November 2016 ...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2018-0220

    authors: Xia J,Hu S,Xu J,Hao H,Yin C,Xu D

    更新日期:2018-11-27 00:00:00

  • The clinical impact of screening for gestational diabetes.

    abstract::Gestational diabetes mellitus (GDM) is defined as carbohydrate intolerance during pregnancy. In Denmark the health service offers selective screening for GDM, i.e., admission to an oral glucose tolerance test (OGTT) after pre-screening with interview for clinical risk factors for GDM, two capillary fasting blood gluco...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 临床试验,杂志文章

    doi:10.1515/CCLM.2004.209

    authors: Schytte T,Jørgensen LG,Brandslund I,Petersen PH,Andersen B

    更新日期:2004-01-01 00:00:00

  • Evaluation of errors in a clinical laboratory: a one-year experience.

    abstract:BACKGROUND:Efficient laboratory service is the cornerstone of modern health care systems. Scientific innovations have contributed to substantial improvements in the field of laboratory science, but errors still prevail. These errors are classified as preanalytical, analytical and postanalytical, depending upon the time...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2010.006

    authors: Goswami B,Singh B,Chawla R,Mallika V

    更新日期:2010-01-01 00:00:00

  • Development and evaluation of an element-tagged immunoassay coupled with inductively coupled plasma mass spectrometry detection: can we apply the new assay in the clinical laboratory?

    abstract::Introduction Element-tagged immunoassay coupled with inductively coupled plasma-mass spectrometry (ICP-MS) detection has the potential to revolutionize immunoassay analysis in clinical detection; however, a systematic evaluation with the standard guidelines of the assay is needed to ensure its performance meets the re...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2019-0566

    authors: Jiang W,Sun G,Wen X,Men S,Cui W,Jing M,Jia X,Hu Z,Pu D,Zhang S,Yuan X,Liu X,Zhang X,Wang C

    更新日期:2020-06-25 00:00:00

  • Evaluation of Prevent ID and Quantum Blue rapid tests for fecal calprotectin.

    abstract:BACKGROUND:Tests for fecal calprotectin are usually either enzyme-linked immunosorbent assays (ELISA) or a time-resolved fluorimetric immunoassay (TRFIA). These time-consuming tests are performed only once every 1 or 2 weeks. Before the results of the tests are known most patients have already undergone colonoscopy. A ...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2011-0855

    authors: Hessels J,Douw G,Yildirim DD,Meerman G,van Herwaarden MA,van den Bergh FA

    更新日期:2012-01-13 00:00:00

  • Cardiotoxic effects and myocardial injury: the search for a more precise definition of drug cardiotoxicity.

    abstract::Drug-induced cardiotoxicity is a major clinical problem; cardiotoxic drugs may induce both cardiac dysfunction and myocardial injury. Several recent studies reported that cardiac troponins measured with high-sensitivity methods (hs-cTn) can enable the early detection of myocardial injury related to chemotherapy or abu...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2020-0566

    authors: Cardinale DM,Zaninotto M,Cipolla CM,Passino C,Plebani M,Clerico A

    更新日期:2020-08-26 00:00:00

  • The integration of the detection of systemic sclerosis-associated antibodies in a routine laboratory setting: comparison of different strategies.

    abstract:BACKGROUND:Detection of systemic sclerosis-associated autoantibodies (SSc-Ab) is mostly restricted to anti-centromere and anti-topoisomerase-I. However, anti-RNA-polymerase-III and anti-PM/Scl are also important diagnostic markers for the disease supporting their incorporation in the laboratory repertoire. The aim of t...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2013-0211

    authors: Bonroy C,Smith V,Van Steendam K,Van Praet J,Deforce D,Devreese K,De Keyser F

    更新日期:2013-11-01 00:00:00

  • A two-step method for the extraction of high-quality RNA from endoscopic biopsies.

    abstract::The use of molecular techniques such as quantitative RT-PCR depends on the quality of cellular RNA. In particular, RNA extraction from endoscopic biopsies is difficult with respect to yield, and especially integrity. Endoscopic biopsies taken from the gastric antrum, corpus and duodenum were subjected to various RNA e...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2003.159

    authors: Wex T,Treiber G,Lendeckel U,Malfertheiner P

    更新日期:2003-08-01 00:00:00

  • Cytokines as plasma markers of abdominal aortic aneurysm.

    abstract:UNLABELLED:The pathogenesis of abdominal aortic aneurysms (AAA) is a complex process in which atherosclerosis and inflammation play a leading role. Cytokines are important mediators of both processes. The aim of our study was to determine whether plasma levels of cytokines which are most involved in AAA pathogenesis ca...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2000.178

    authors: Treska V,Topolcan O,Pecen L

    更新日期:2000-11-01 00:00:00

  • The association between plasminogen activator inhibitor type 1 (PAI-1) levels, PAI-1 4G/5G polymorphism, and myocardial infarction: a Mendelian randomization meta-analysis.

    abstract:BACKGROUND:The circulating levels of plasminogen activator inhibitor type 1 (PAI-1) are increased in individuals carrying the 4G allele at position -675 of the PAI-1 gene. In turn, overexpression of PAI-1 has been found to affect both atheroma and thrombosis. However, the association between PAI-1 levels and the incide...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章,meta分析

    doi:10.1515/cclm-2013-1124

    authors: Nikolopoulos GK,Bagos PG,Tsangaris I,Tsiara CG,Kopterides P,Vaiopoulos A,Kapsimali V,Bonovas S,Tsantes AE

    更新日期:2014-07-01 00:00:00

  • Precision performance at low levels and 99th percentile concentration of the Access AccuTnl assay on two different platforms.

    abstract:BACKGROUND:Cardiac troponins currently represent the preferred biomarkers for the detection of myocardial necrosis. The objective of the present study was to compare the performance of the Access AccuTnl assay (Beckman Coulter) measured on two different platforms, the UniCel Dxl 800 and the Access 2 (Beckman Coulter). ...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm.2009.080

    authors: Zaninotto M,Mion MM,Novello E,Moretti M,Delprete E,Rocchi MB,Sisti D,Plebani M

    更新日期:2009-01-01 00:00:00

  • European multicenter analytical evaluation of the Abbott ARCHITECT STAT high sensitive troponin I immunoassay.

    abstract:BACKGROUND:International recommendations highlight the superior value of cardiac troponins (cTns) for early diagnosis of myocardial infarction along with analytical requirements of improved precision and detectability. In this multicenter study, we investigated the analytical performance of a new high sensitive cardiac...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章,多中心研究

    doi:10.1515/cclm-2014-0107

    authors: Krintus M,Kozinski M,Boudry P,Capell NE,Köller U,Lackner K,Lefèvre G,Lennartz L,Lotz J,Herranz AM,Nybo M,Plebani M,Sandberg MB,Schratzberger W,Shih J,Skadberg Ø,Chargui AT,Zaninotto M,Sypniewska G

    更新日期:2014-11-01 00:00:00

  • Holotranscobalamin as a predictor of vitamin B12 status.

    abstract::We report on the performance of a new test, holotranscobalamin, as compared to well established markers of vitamin B12 deficiency (plasma cobalamins, methylmalonic acid, and homocysteine). Holotranscobalamin was analyzed in 143 samples by a competitive radiobinding assay (Axis-Shield). Employing a cut-off value of 50 ...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2003.228

    authors: Hvas AM,Nexo E

    更新日期:2003-11-01 00:00:00

  • DNA methylation biomarkers in biological fluids for early detection of respiratory tract cancer.

    abstract::Cancers of the respiratory tract (lung and head and neck) share common aetiologies, risk factors and molecular characteristics. Epigenetic reprogramming is one of the hallmarks of cancer and DNA methylation is currently the best-studied form. There are a number of characteristics of DNA methylation, which seem advanta...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章,评审

    doi:10.1515/cclm-2012-0124

    authors: Markopoulou S,Nikolaidis G,Liloglou T

    更新日期:2012-10-01 00:00:00

  • Prostate-specific antigen and new related markers for prostate cancer.

    abstract::Although prostate-specific antigen (PSA), or human kallikrein 3, is the most valuable tool available for the diagnosis and management of prostate cancer, as currently used it is insufficiently sensitive and specific for early detection or staging of the malignancy. Many new concepts have been introduced in order to op...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章,评审

    doi:10.1515/CCLM.1998.120

    authors: Daher R,Beaini M

    更新日期:1998-09-01 00:00:00

  • Defining reference intervals for a serum growth differentiation factor-15 (GDF-15) assay in a Caucasian population and its potential utility in diabetic kidney disease (DKD).

    abstract:BACKGROUND:Growth differentiation factor-15 (GDF-15), a stress responsive cytokine, is a promising biomarker of renal functional decline in diabetic kidney disease (DKD). This study aimed primarily to establish normative data and secondarily to evaluate the potential utility of GDF-15 in DKD using Roche Diagnostics ele...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2018-0534

    authors: Hamon SM,Griffin TP,Islam MN,Wall D,Griffin MD,O'Shea PM

    更新日期:2019-03-26 00:00:00

  • Reference values for plasma dipeptidyl-peptidase IV activity and their association with other laboratory parameters.

    abstract::In blood, the exopeptidase dipeptidyl-peptidase IV (DPPIV; EC 3.4.14.5) is predominantly present in a soluble form in plasma/serum and as an activation antigen on the membrane of lymphocytes (CD26). It modifies some important biologically active peptides (neuropeptides, chemokines), and a regulatory role for DPPIV/CD2...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2001.026

    authors: Durinx C,Neels H,Van der Auwera JC,Naelaerts K,Scharpe S,De Meester I

    更新日期:2001-02-01 00:00:00

  • The uncoupling protein-1 gene -3826A/G polymorphism and hypertension in Japanese subjects.

    abstract:BACKGROUND:The possible effects of the uncoupling protein-1 (UCP-1) gene -3826A/G polymorphism on hypertension (HT) have yet to be elucidated. METHODS:A total of 578 Japanese subjects (231 males and 347 females, mean age 58.4 years) were enrolled in the study to investigate the association between HT and the -3826A/G ...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2007.253

    authors: Kotani K,Sakane N,Saiga K,Tsuzaki K,Shimohiro H,Tabata M,Kurozawa Y

    更新日期:2007-01-01 00:00:00

  • Complexity, cost, and content - three important factors for translation of clinical protein mass spectrometry tests, and the case for apolipoprotein C-III proteoform testing.

    abstract::Complexity, cost, and content are three important factors that can impede translation of clinical protein mass spectrometry (MS) tests at a larger scale. Complexity stems from the many components/steps involved in bottom-up protein MS workflows, making them significantly more complicated than enzymatic immunoassays (E...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2019-0977

    authors: Nedelkov D,Hu Y

    更新日期:2020-06-25 00:00:00

  • Automated prozone effect detection in ferritin homogeneous immunoassays using neural network classifiers.

    abstract::The application of turbidimetric homogeneous immunoassays made the determination of several plasma components widely available. The sensitivity and accuracy of these assays are appropriate enough for routine laboratory use; however, in the case of many pathologically high concentration samples, prozone effect (high do...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.1999.076

    authors: Papik K,Molnar B,Fedorcsak P,Schaefer R,Lang F,Sreter L,Feher J,Tulassay Z

    更新日期:1999-04-01 00:00:00

  • Immunoglobulin G Fc(gamma) receptor expression on polymorphonuclear cells in bronchoalveolar lavage fluid of HIV-infected and HIV-seronegative patients with bacterial pneumonia.

    abstract::This study was designed to test the hypothesis that impaired neutrophil function might contribute to the development of bacterial pneumonia in patients with HIV-infection. Numbers of inflammatory cells and immunoglobulin G Fcgamma receptor (IgG FcgammaR) I, II, III levels were investigated in bronchoalveolar lavage (B...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2004.035

    authors: Armbruster C,Krugluger W,Huber M,Stephan K

    更新日期:2004-02-01 00:00:00