Abstract:
:This in vitro study measured cusp deflection associated with MOD resin composite restorations in maxillary premolars with different curing light modes. Soft-start polymerization may reduce cusp deflection by reducing polymerization shrinkage stress. Forty maxillary premolars were mounted in stone and slot MOD cavities were prepared. The teeth were randomized into four groups: Group A--cavities were etched, bonded and restored with two increments of Z-100 composite. Each increment was cured with an LED curing light (fast curing mode). Group B--similar to Group A except that the LED curing light with pulse curing mode was used. Group C--similar to Group A except that the LED curing light with stepped curing mode was used. Group D--a visible curing light was used for curing the composite. The distance between the indexed cusp tips was measured before the restorations were completed and five minutes after, 24 hours after and two weeks after completion of the restorations. The mean contraction of the cusps in microm at five minutes, 24 hours and two weeks, respectively, for each group was A: 25.4, 16.2 and 8.2, B: 6.4, 3.4 and 2.2, C: 11.6, 7.0 and 4.4, D: 33.0, 21.6 and 15.8. Group D resulted in the highest deflection, Group A was intermediate and Groups B and C were the lowest. Ten samples of the composite for each group with 2-mm thickness were prepared for the Vickers hardness test. No difference among the samples was found.
journal_name
Oper Dentjournal_title
Operative dentistryauthors
Alomari QD,Mansour YFkeywords:
subject
Has Abstractpub_date
2005-11-01 00:00:00pages
684-9issue
6eissn
0361-7734issn
1559-2863journal_volume
30pub_type
杂志文章,随机对照试验abstract::Provisional restorations of full crown preparations may permit more microleakage of bacteria and their products than the final castings do. However, most investigations of the sealing qualities of cemented castings have reported that they too permit dye leakage. One approach to the problem is to seal the dentin with d...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1992-01-01 00:00:00
abstract::This study evaluated the in vivo effects of bleaching agents containing 10% carbamide peroxide (Platinum/Colgate) or 7.5% hydrogen peroxide (Day White 2Z/Discus Dental) on mutans Streptococcus during dental bleaching. The products were applied on 30 volunteers who needed dental bleaching. In each volunteer, one of the...
journal_title:Operative dentistry
pub_type: 临床试验,杂志文章,随机对照试验
doi:
更新日期:2005-07-01 00:00:00
abstract::This study investigated the effectiveness of cure and post-gel shrinkage of three visible light-cured composite resins (In Ten-S [IT], Ivoclar Vivadent; Z100 [ZO], 3M-ESPE; Tetric Ceram [TC], Ivoclar Vivadent) when polymerized with a very high intensity (1296 +/- 2 mW/cm2) halogen light (Astralis 10, Ivoclar Vivadent)...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2003-07-01 00:00:00
abstract::Coronal fractures of posterior teeth are not rare in clinical practice. Most of the time they constitute a restorational problem for the clinician, since they usually end below the free gingival crest. Two hundred coronal fractures of posterior teeth were examined in this study, with respect to several factors. Some o...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1989-01-01 00:00:00
abstract:OBJECTIVE::Computer aided design-computer aided machining (CAD-CAM) ceramic crowns are replacing ceramo-metal ones due to newly developed mechanical properties and esthetics. To obtain knowledge about their interactions due to polishing and occlusal contacts with the opposing dental enamel specimen, including surface r...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/17-153-L
更新日期:2019-01-01 00:00:00
abstract::Good wettability is one of the desirable physical properties of mercury-free gallium-based alloys (Gallium Alloy GF). However, wettability, while providing good adhesion to the cavity wall, has the adverse effect of causing stickiness to the inside of the capsule during mixing, and also to the metal hand instruments u...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1996-01-01 00:00:00
abstract::Most manufacturers of dental adhesives have both a total-etch adhesive and a simplified self-etching adhesive available on the market. This study measured the enamel microtensile bond strengths of five pairs of enamel adhesives as a function of enamel roughness. The proximal surfaces of 25 extracted mandibular molars ...
journal_title:Operative dentistry
pub_type: 临床试验,杂志文章,随机对照试验
doi:
更新日期:2005-07-01 00:00:00
abstract::This in vitro study compared the marginal and internal adaptation of bulk-filled Class I and cuspal coverage direct resin composite restorations filled with different types of adhesive restorative systems and different thicknesses of bonding agent. Seventy-two intact, caries-free, freshly extracted human molars were r...
journal_title:Operative dentistry
pub_type: 杂志文章,随机对照试验
doi:10.2341/06-157
更新日期:2007-09-01 00:00:00
abstract::This study was designed to compare strength, elastic modulus (stiffness), and hardness for five composite resin materials that are used for laboratory-fabricated posterior composite restorations. Ten specimens of each material were processed according to the manufacturer's instructions. Statistical analysis indicated ...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1994-11-01 00:00:00
abstract:OBJECTIVE:This study evaluated the differences in enamel color change, surface hardness, elastic modulus, and surface roughness between treatments with four bleaching gels containing carbamide peroxide (two at 10% and one each at 35%, and 45%) and two bleaching gels containing hydrogen peroxide (two at 40%). METHODS:E...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/15-010-L
更新日期:2016-01-01 00:00:00
abstract::The current study evaluated the chromatic influence of high, medium and low value composites on a dentin composite substrate (A2 shade) using spectrophotometric analysis. The specimens were divided into the following four groups: a) control (CG), entirely composed of dentin composite (n = 5); b) high value (GHV), dent...
journal_title:Operative dentistry
pub_type: 杂志文章,随机对照试验
doi:10.2341/09-44-L
更新日期:2010-01-01 00:00:00
abstract::A literature review was conducted on adhesive Class I and II restorations and nondestructive in vitro tests using the PubMed/Medline database for the 1995-2010 period. The first part of this review has presented and critically appraised selected literature dealing with the quality and in vitro behavior of adhesive Cla...
journal_title:Operative dentistry
pub_type: 杂志文章,评审
doi:10.2341/12-020B-LIT
更新日期:2013-09-01 00:00:00
abstract::One hundred non-carious, non-undercut cervical lesions were restored with Silux Plus or Estio LC and bonded with Fuji Bond LC. The restorations were evaluated yearly for retention and marginal discoloration. After five years, the overall retention rate was 96%. Of the 41 restorations examined at five years, five had c...
journal_title:Operative dentistry
pub_type: 临床试验,杂志文章
doi:
更新日期:2002-09-01 00:00:00
abstract::The antibacterial properties of self-etching adhesive systems constitute an important issue in operative dentistry, since viable bacteria can still be present after cavity preparation. The current study evaluated the antibacterial activity of five one-step self-etching adhesives (SEAs) and four self-etching primers (S...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/09-297-L
更新日期:2010-07-01 00:00:00
abstract::This study compared the surface finish of eight different types of aesthetic restorative materials. The materials included resin-modified (Fuji II LC [FL], GC) and highly viscous (Fuji IX GP Fast [FN], GC) glass ionomer cements, a compomer (F2000 [FT], 3M-ESPE), minifilled (Z100 [ZO], 3M-ESPE) and microfilled (A110 [A...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2004-01-01 00:00:00
abstract:OBJECTIVES:It has been reported that bleaching generates an increase in the activity of osteoclasts in vitro. We quantified the RANK-L and IL-1β biomarkers in a double-blind, randomized clinical trial evaluating the in vivo effect of hydrogen peroxide (35%) and peroxide carbamide (37%) six months after whitening. METH...
journal_title:Operative dentistry
pub_type: 杂志文章,随机对照试验
doi:10.2341/18-023-C
更新日期:2019-11-01 00:00:00
abstract:CLINICAL RELEVANCE:The degree of conversion of contemporary universal adhesives positively correlates with the bond strength to dentin. The correlation is more marked after thermocycling, suggesting that a high degree of conversion is required for long-term dentin bonding durability. SUMMARY:Purpose: The objectives of...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/19-165-L
更新日期:2020-09-01 00:00:00
abstract:PURPOSE:The present study aimed to investigate a novel adhesive system containing 0.2% chlorhexidine digluconate (CHX) for its ability to improve the stability of the adhesive interface compared with the use of 2% CHX as a therapeutic primer. Furthermore, the study aimed to confirm the inhibitory properties of these CH...
journal_title:Operative dentistry
pub_type: 杂志文章,随机对照试验
doi:10.2341/12-239-L
更新日期:2013-11-01 00:00:00
abstract:OBJECTIVE:The aim of this study was to compare the in vivo diagnostic ability of a laser fluorescence system (DIAGNOdent, KaVo, Biberac, Germany) with that of visual inspection in the early detection of occlusal caries in newly erupted noncavitated first permanent molars among caries-active children. MATERIALS AND MET...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/10-309-C
更新日期:2011-07-01 00:00:00
abstract:OBJECTIVE:To evaluate the effect of mechanical loading on the microtensile bond strength (MTBS) of five adhesive systems to dentin. METHODS:Flat dentin surfaces from human molars were divided into five groups and bonded with total-etch self-priming adhesives (Single Bond, Prime&Bond NT and Prime&Bond XP), two-step sel...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/04-161
更新日期:2006-01-01 00:00:00
abstract::Minimally invasive flowable composite Class I restorations are widely used. However, flowable composites are characterized by low filler contents, modified resin formulations, low moduli of elasticity, low viscosity, generally poor mechanical properties, and decreased long-term stability. The purpose of this study was...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/11-106-L
更新日期:2012-05-01 00:00:00
abstract::Veneers were fabricated by CEREC CAD-CAM and the platinum foil techniques for standardized preparations on 10 artificial teeth. Mesial preparation contacts were broken, but distal contacts remained intact. The veneers were cemented in a standardized manner to their teeth. The veneers and their attached cement were emb...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1997-05-01 00:00:00
abstract::The stronger the ceramic material, the longer the restoration stays in the mouth. The current study evaluated the two-year clinical performance of a strong ceramic system, IPS Empress II, with increased strength on onlay/inlay restorations of molars. Teeth from 35 patients, including three premolars and 32 molars, wer...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/08-97
更新日期:2009-07-01 00:00:00
abstract::This study evaluated the regional tensile bond strength of a dual-cure resin composite core material to root canal dentin using photo and dual-cure adhesives and different modes of polymerization. Nineteen extracted premolars were decoronated and their root canals prepared to a depth of 8 mm and a width of 1.4 mm usin...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2003-09-01 00:00:00
abstract:OBJECTIVES:To evaluate the efficacy of a new light-cured anesthetic gel for pain control in adults undergoing rubber dam isolation for the restorative treatment of noncarious cervical lesions (NCCLs). METHODS AND MATERIALS:This study was a randomized, split-mouth, triple-blind, controlled trial. The sample comprised 5...
journal_title:Operative dentistry
pub_type: 杂志文章,随机对照试验
doi:10.2341/18-130-C
更新日期:2020-03-01 00:00:00
abstract::A core foundation system is frequently used in endodontically treated teeth that suffer excessive loss of the coronal portion of their structure. The volumetric shrinkage of core foundation resins may create marginal gaps that influence the bonding ability and longevity of a restored tooth. Little is known about how a...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2005-09-01 00:00:00
abstract:OBJECTIVES::The use of high-viscosity glass-ionomer cements (HVGICs) for atraumatic restorative treatment (ART) restorations is widely practiced with the advent of various HVGICs. However, the bonding of the latter to caries-affected dentin (CAD) should be validated, especially because it is the common substrate left a...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/17-154-L
更新日期:2018-11-01 00:00:00
abstract:PURPOSE:This study evaluated the amount of residual yellow in cured resin composites when polymerizing with either a quartz-tungsten-halogen (QTH) or blue light-emitting diode (LED). MATERIAL AND METHODS:Twelve shades (bleaching to conventional shades) of microfill, hybrid and microhybrid resin composite specimens (n ...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/06-129
更新日期:2007-09-01 00:00:00
abstract::The purpose of this study was to find out the degree to which eugenol-containing temporary cements or temporary filling materials affected shear bond strength of a dual-cure resin luting cement to acid-etched enamel. For this purpose 56 human caries-free third molars were embedded in acrylic resin and cross sectioned ...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1998-03-01 00:00:00
abstract:PURPOSE:To investigate clinical performance of a low-shrinkage silorane-based composite resin when used for repairing conventional dimethacrylate-based composite restorations. BACKGROUND:Despite the continued development of resin-based materials, polymerization shrinkage and shrinkage stress still require improvement....
journal_title:Operative dentistry
pub_type: 杂志文章,随机对照试验
doi:10.2341/11-121-C
更新日期:2012-09-01 00:00:00