Abstract:
:The current study evaluated the chromatic influence of high, medium and low value composites on a dentin composite substrate (A2 shade) using spectrophotometric analysis. The specimens were divided into the following four groups: a) control (CG), entirely composed of dentin composite (n = 5); b) high value (GHV), dentin composite and high value composite (n = 20); c) medium value (GMV), dentin composite and medium value composite (n = 20) and d) low value (GLV), dentin composite and low value composite (n = 20). The dentin composite was 2.0 mm thick and the value composite was added in four different thicknesses, dividing the groups into four subgroups: S1 = 1.0 mm, S2 = 0.8 mm, S3 = 0.6 mm and S4 = 0.4 mm. The results were determined using the CIELAB system and differences in brightness of the specimens were analyzed using two-way ANOVA. Significant differences were found between different value resin composites, thicknesses and interactions, as revealed by the Tukey's test (HSD). Adding value composite produced lower brightness, and a gray shade was observed, compared to the control, regardless of the value or thickness of the primary composite. Eleven of the 12 subgroups presented clinically unacceptable chromatic changes, except when the 0.4 mm thickness of high value composite was used.
journal_name
Oper Dentjournal_title
Operative dentistryauthors
Schmeling M,Meyer-Filho A,de Andrada MA,Baratieri LNdoi
10.2341/09-44-Lsubject
Has Abstractpub_date
2010-01-01 00:00:00pages
44-9issue
1eissn
0361-7734issn
1559-2863journal_volume
35pub_type
杂志文章,随机对照试验abstract::Of the many factors under their control, clinicians can manipulate light-exposure duration but must deal with a set intensity of light emitted from the dental curing unit. This research investigates the interdependence of exposure duration and source intensity on resin cure at various depths within a simulated light-c...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1994-01-01 00:00:00
abstract:OBJECTIVES:To evaluate and compare the fracture toughness of dental CAD/CAM materials of different material classes intended for in-office milling (glass ceramics, hybrid, resin composites) and the influence of aging on this property. METHODS AND MATERIALS:The fracture toughness (critical intensity factor, KIc) values...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/18-161-L
更新日期:2019-07-01 00:00:00
abstract::To protect glass-ionomer cement from moisture contamination and dehydration during initial setting, immediate application of a surface coating agent is recommended. This study compared the effect of various surface coatings on F release from glass-ionomer cement. Twenty glass-ionomer cement (Ketac Fil Aplicap) disks (...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1994-09-01 00:00:00
abstract::Dentin bridging of 150 mechanically exposed monkey pulps to two adhesive resins [BondWell LC (BW); Clearfil Liner Bond II (LB)] and a calcium hydroxide cement [Dycal (DY)] were histopathologically evaluated at 3, 7, 14, 30, and 60 days after operation (n = 10). The dentin bridge structure was three-dimensionally recon...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2000-05-01 00:00:00
abstract::The objective of this paper is to review the literature concerning factors affecting adhesion to mineralized tissues. Factors related to the physicochemical structure of the adherents and to the inherent properties of composite restorative materials, along with the postulated bonding mechanisms of current adhesive sys...
journal_title:Operative dentistry
pub_type: 杂志文章,评审
doi:
更新日期:1992-01-01 00:00:00
abstract:CLINICAL RELEVANCE:When a resin nanoceramic inlay is cemented using self-adhesive cement, a universal dentin adhesive can be applied to the prepared cavity. The application of the adhesive before self-adhesive cement placement provides similar or better interfacial adaptation than without the adhesive. SUMMARY:Purpose...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/19-141-L
更新日期:2020-11-01 00:00:00
abstract::The clinical performance of light curing resin composites is greatly influenced by the quality of the light-curing unit (LCU). Halogen LCUs are commonly used for curing composite materials. However, they have some drawbacks. The development of new, blue, super bright light emitting diodes (LED LCU) of 470-nm wavelengt...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2005-01-01 00:00:00
abstract::The tested hypotheses of this study were that dentin enamel bonding agents (DBAs) proposed for compomers create a hybrid layer (HL) that seals the margins of Class V restorations and HL is free from voids or gaps on both enamel and dentin margins. For purposes of this study, Class V restorations (n = 70) were made in ...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2004-01-01 00:00:00
abstract::The purpose of this study was to evaluate the 1-year results of the dentin bond (DBS)/viscous resin liner combinations Amalgambond Plus, Tenure/Panavia, Syntac/Dual Cem, and All-Bond 2/Liner F in reducing microleakage in class 5 cavity preparations restored with an admixed or a spherical amalgam alloy and to compare t...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1998-01-01 00:00:00
abstract::This study evaluated the two-year clinical performance of two minimally invasive cavity preparation techniques, bur and laser, in Class I occlusal resin composite restorations. Twenty-seven patients, each having at least one pair of occlusal caries, were enrolled in this study. For each patient, one of the cavities wa...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/09-339-C
更新日期:2010-09-01 00:00:00
abstract:OBJECTIVES:To evaluate the effect of different surface treatments on the bond strength to a composite and a polymer-infiltrated ceramic CAD/CAM block after six-month artificial aging. METHODS AND MATERIALS:Two types of CAD/CAM blocks (Cerasmart, GC; Enamic, Vita Zahnfabrik) were cut in slabs of 4-mm thickness, divided...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/15-263-L
更新日期:2017-01-01 00:00:00
abstract::This study evaluated the effect of cyclic loading on the bond strength of Class II restorations using different composite materials. Class II preparations with gingival margins located in dentin were performed on the mesial surface of 80 bovine incisors. The teeth were randomly allocated to eight groups (n=10) accordi...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/07-65
更新日期:2008-03-01 00:00:00
abstract::This study investigated the reasons for placement and replacement of dental restorations in the United States Navy Dental Corps. The relationship between restoration longevity and the reasons for replacement of restorations was also studied. Data on newly placed dental restorations were collected from restorative dent...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1993-09-01 00:00:00
abstract::This investigation examined the susceptibility to staining and translucency changes of some new tooth-colored restorative materials after immersion in different beverages. The materials studied were 3M Filtek Z350XT (ZT), 3M Filtek 350XT Flowable Restorative (ZF), Shofu Beautifil Flow Plus (BF), Shofu Beautifil II (B2...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/149027-L
更新日期:2015-03-01 00:00:00
abstract:PURPOSE:To investigate clinical performance of a low-shrinkage silorane-based composite resin when used for repairing conventional dimethacrylate-based composite restorations. BACKGROUND:Despite the continued development of resin-based materials, polymerization shrinkage and shrinkage stress still require improvement....
journal_title:Operative dentistry
pub_type: 杂志文章,随机对照试验
doi:10.2341/11-121-C
更新日期:2012-09-01 00:00:00
abstract::SUMMARY The purpose of this study was to evaluate the influence the width of the occlusal isthmus and inlay material had on the stress distribution, displacement, and fracture resistance of upper human premolars. For this in vitro test, 35 intact upper premolars (UPM) were selected and five were kept intact for the co...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/13-092-L
更新日期:2014-07-01 00:00:00
abstract:OBJECTIVES:Inadequately polymerized resin cements may negatively affect the clinical performance of cemented all-ceramic restorations. The purpose of this in vitro study was to evaluate the effect of ceramic thickness and shade on the microhardness of various light-cured (LC) and dual-cured (DC) resin cements. The amou...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/10-206-L
更新日期:2011-11-01 00:00:00
abstract::This study evaluated the effect of an intracoronal resin composite pin on Class IV resin composite restorations. A control group of 16 bovine teeth was prepared with standardized conventional Class IV preparations. For an experimental group, 16 similar Class IV preparations were made, with the addition of an intracoro...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2000-07-01 00:00:00
abstract::On occasion we receive manuscripts that we would like to publish, but do not have the page room to include in the print journal. For the full article, please go to www.jopdentonline.org or enter the provided address into your address bar. ...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/1559-2863-42.6.680
更新日期:2017-11-01 00:00:00
abstract::This study compares volumetric changes and rates of shrinkage during different stages of polymerization of dental resin composites and compomers exposed to the same total energy by using two different combinations of power density and exposure duration. A hybrid composite and its equivalent flowable and a compomer and...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2003-09-01 00:00:00
abstract::The purpose of this double-blind clinical trial was to compare the retention rate in noncarious Class V lesions of two resin-based composite restorative materials with contrasting stiffness. Isolation with retraction cord, pressed paper triangles, and cotton rolls was used to closely mimic the procedures generally use...
journal_title:Operative dentistry
pub_type: 临床试验,杂志文章,随机对照试验
doi:
更新日期:2000-01-01 00:00:00
abstract:OBJECTIVES:This randomized clinical trial tested the three-month desensitizing effect of two protocols using nano-hydroxyapatite formulations compared with Pro-Argin and fluoride varnish. METHODS:Twenty-eight subjects with 137 teeth presenting dentin exposure with a minimal hypersensitivity of four on the visual analo...
journal_title:Operative dentistry
pub_type: 杂志文章,随机对照试验
doi:10.2341/15-145-C
更新日期:2016-07-01 00:00:00
abstract:CLINICAL RELEVANCE:The use of laser light during bleaching will not reduce the incidence or severity of sensitivity and will not increase the degree of color change compared with nonlaser light sources. SUMMARY:Objective: To evaluate whether the use of laser during in-office bleaching promotes a reduction in dental se...
journal_title:Operative dentistry
pub_type: 杂志文章,meta分析
doi:10.2341/19-064-L
更新日期:2020-11-01 00:00:00
abstract::This study evaluated the effect of two dentin disinfectants (Consepsis, Tubulicid), one aqueous HEMA solution (Aqua Prep), a combination of Aqua Prep and Tubulicid and an air abrasion treatment (50 microns aluminum oxide) on the shear bond strength (SBS) of two acetone-based single bottle adhesives (One Step and Prime...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2001-11-01 00:00:00
abstract::This study compared the surface finish of eight different types of aesthetic restorative materials. The materials included resin-modified (Fuji II LC [FL], GC) and highly viscous (Fuji IX GP Fast [FN], GC) glass ionomer cements, a compomer (F2000 [FT], 3M-ESPE), minifilled (Z100 [ZO], 3M-ESPE) and microfilled (A110 [A...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2004-01-01 00:00:00
abstract::The current study investigated the influence of carbamide peroxide on the flexural strength of tooth-colored restorative materials at two environmental temperatures. Seven restorative materials were used, including four resin composites (Filtek Z350, Filtek Z250, Synergy Flow and Filtek P60), a polyacid-modified compo...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/09-139-L
更新日期:2010-05-01 00:00:00
abstract::The development of adhesive agents for bonding composite to dentin has rapidly evolved in recent years. It is postulated that dentin bond strengths in the range of 17 MPa are sufficient to resist the polymerization shrinkage of composite resins. The purpose of this study was to evaluate the shear bond strengths of the...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1995-03-01 00:00:00
abstract::Light Emitting Diode (LED) curing units are attractive to clinicians, because most are cordless and should create less heat within tooth structure. However, questions about polymerization efficacy have surrounded this technology. This research evaluated the adequacy of the depth of cure of pit & fissure sealants provi...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2005-11-01 00:00:00
abstract::Detailed and accurate impressions are made when the oral environment is dry during the impression process. Maintaining a dry field on medically, physically, or emotionally compromised patients can be very challenging. If not achieved, it may compromise dental care and accurate outcomes. This article describes a techni...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/11-290-T
更新日期:2014-01-01 00:00:00
abstract::This study evaluated the effects of acid etching of the enamel and the combination of different light sources (halogen light, light-emitting diodes [LEDs], and LED/Laser) and the bleaching product on color change, penetration of hydrogen peroxide (H2O2), and cytotoxicity over time. The color change (ΔE) and the amount...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/14-364-L
更新日期:2016-01-01 00:00:00