Abstract:
:This study compares volumetric changes and rates of shrinkage during different stages of polymerization of dental resin composites and compomers exposed to the same total energy by using two different combinations of power density and exposure duration. A hybrid composite and its equivalent flowable and a compomer and its equivalent flowable were exposed using a halogen curing unit set at 400 mW/cm2 for 40 seconds and 800 mW/cm2 for 20 seconds: delivering 16 J/cm2 in both cases. Volumetric changes were recorded every 0.5 seconds using a mercury dilatometer. Ten replications per test condition were performed and the data were subjected to ANOVA. Statistically significant differences in shrinkage values and rates among different power densities were determined by means of paired t-tests at a 95% confidence level. Significantly more shrinkage (p<0.05) was found for the higher filled materials, Z250 and Dyract AP, when higher power density was used. However, no significant differences were found between their flowable counterparts when exposed to various power densities. Of the four materials, only Dyract AP exhibited no significant difference in shrinkage rate when various power densities were used. All the other materials exhibited significantly higher rates (p<0.05) at the higher power density.
journal_name
Oper Dentjournal_title
Operative dentistryauthors
Oberholzer TG,Pameijer CH,Grobler SR,Rossouw RJkeywords:
subject
Has Abstractpub_date
2003-09-01 00:00:00pages
622-7issue
5eissn
0361-7734issn
1559-2863journal_volume
28pub_type
杂志文章abstract::The aim of this investigation was to verify the influence of 3 light curing units on the degree of conversion, using different irradiation conditions: 1) manufacturers' recommended times of photo-activation, 2) standardizing total energy density among the units and 3) standardizing energy density at the 450-490 nm wav...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/05-81
更新日期:2006-07-01 00:00:00
abstract::To evaluate the correlation between microtensile dentin bond strength (microTBS) and silver ion penetration, two total-etch 3-step and one self-etch 2-step system were investigated. OptiBond FL adhesive was applied to flat occlusal dentin on six non-carious human molars, and a resin composite "crown" was formed in 2 m...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2003-01-01 00:00:00
abstract::This study investigated the effectiveness of cure and post-gel shrinkage of three visible light-cured composite resins (In Ten-S [IT], Ivoclar Vivadent; Z100 [ZO], 3M-ESPE; Tetric Ceram [TC], Ivoclar Vivadent) when polymerized with a very high intensity (1296 +/- 2 mW/cm2) halogen light (Astralis 10, Ivoclar Vivadent)...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2003-07-01 00:00:00
abstract:INTRODUCTION:Limited access to interdental spaces complicates removal of excess material when placing class II composite resin restorations. Evidence-based recommendations on interproximal finishing are rare. We present novel microscalpels for this indication. The aim of the study was to test their fracture strength an...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/16-012-L
更新日期:2017-05-01 00:00:00
abstract:OBJECTIVE:The aim of this study was to compare the in vivo diagnostic ability of a laser fluorescence system (DIAGNOdent, KaVo, Biberac, Germany) with that of visual inspection in the early detection of occlusal caries in newly erupted noncavitated first permanent molars among caries-active children. MATERIALS AND MET...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/10-309-C
更新日期:2011-07-01 00:00:00
abstract::The purpose of this study was to compare the long-term survivals of two low-copper and three high-copper amalgam alloys, and to analyze four clinical factors for their possible effects on the restoration survivals. Some 1476 polished restorations were placed in hospital patients by a large number of operators and asse...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1991-09-01 00:00:00
abstract::This in-vitro study compared the resistance of extensive amalgam restorations retained by either four Regular TMS Link Plus pins, four amalgapins, Amalgambond Plus, Amalgambond Plus with HPA, Scotchbond Multi-Purpose Plus, PQ Amalgam, Panavia F 2.0, All-Bond 2 or Resinomer. Ninety caries-free third molars were embedde...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/08-5
更新日期:2008-11-01 00:00:00
abstract:OBJECTIVES::To evaluate the effect of a remineralizing gel combining fluoride and calcium silicate/phosphate or a sodium fluoride gel on bleached enamel microhardness, color, and wear susceptibility. METHODS AND MATERIALS::Two hundred forty bovine enamel-dentin samples were prepared. Baseline analysis of Knoop microha...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/17-150-L
更新日期:2019-01-01 00:00:00
abstract::This study evaluated the effect of two dentin disinfectants (Consepsis, Tubulicid), one aqueous HEMA solution (Aqua Prep), a combination of Aqua Prep and Tubulicid and an air abrasion treatment (50 microns aluminum oxide) on the shear bond strength (SBS) of two acetone-based single bottle adhesives (One Step and Prime...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2001-11-01 00:00:00
abstract::This study compared the slice method of measuring microleakage to the whole-wall method. Forty-eight Class V direct metal restorations were placed in the buccal and lingual surfaces of 24 human molars. Following thermocycling and storage in 2% methylene blue stain for 12 hours, the teeth were sectioned and the restora...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2002-11-01 00:00:00
abstract:PURPOSE:The present study aimed to investigate a novel adhesive system containing 0.2% chlorhexidine digluconate (CHX) for its ability to improve the stability of the adhesive interface compared with the use of 2% CHX as a therapeutic primer. Furthermore, the study aimed to confirm the inhibitory properties of these CH...
journal_title:Operative dentistry
pub_type: 杂志文章,随机对照试验
doi:10.2341/12-239-L
更新日期:2013-11-01 00:00:00
abstract:OBJECTIVES:Whitening efficacy has been related to hydrogen peroxide (HP) diffusion into tooth structure. However, little information is available relating rheological properties to whitening efficacy. The purpose was to evaluate the whitening efficacy and HP penetration level of a 10% HP gel at three different viscosit...
journal_title:Operative dentistry
pub_type: 杂志文章,随机对照试验
doi:10.2341/17-099-L
更新日期:2018-05-01 00:00:00
abstract::This study compared the thickness of the hybrid layer formed using Scotchbond Multi-Purpose Plus, Single Bond 2, Prime & Bond 2.1 and Xeno III on a dentin surface prepared with a diamond bur in a high speed handpiece or prepared with an Er:YAG laser used with two parameters of pulse energy (200 and 400 mJ) and two par...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/07-84
更新日期:2008-05-01 00:00:00
abstract::This study evaluated the effect of an intracoronal resin composite pin on Class IV resin composite restorations. A control group of 16 bovine teeth was prepared with standardized conventional Class IV preparations. For an experimental group, 16 similar Class IV preparations were made, with the addition of an intracoro...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2000-07-01 00:00:00
abstract::SUMMARY The purpose of this study was to evaluate the influence the width of the occlusal isthmus and inlay material had on the stress distribution, displacement, and fracture resistance of upper human premolars. For this in vitro test, 35 intact upper premolars (UPM) were selected and five were kept intact for the co...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/13-092-L
更新日期:2014-07-01 00:00:00
abstract::Standardized class 4 cavities were prepared in bovine incisors and restored with a microfilled composite resin. The composite restorations were retained either by acid etching technique (AET) alone or by acid etching technique in combination with a self-threading retentive pin. Pins covered with a bonding/opaquer coat...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1994-05-01 00:00:00
abstract::This study investigated the influence of different light sources associated with a transdental photoactivation technique on the marginal adaptation and hardness of composite restorations. Cavities (3 mm wide x 3 mm long x 1.5 mm in deep) were prepared on flattened bovine dentin and filled with Z250 composite (3M ESPE)...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/07-109
更新日期:2008-07-01 00:00:00
abstract::This study investigated the effect of a crown-lengthening ferrule on the fracture resistance of endodontically-treated teeth restored with two dowel-core systems. Thirty-two extracted mandibular first premolars were sectioned perpendicular to the long axis at a point 1.0 mm occlusal to the buccal cementoenamel junctio...
journal_title:Operative dentistry
pub_type: 杂志文章,随机对照试验
doi:10.2341/06-169
更新日期:2007-11-01 00:00:00
abstract::In this laboratory study, the microtensile bond strengths (μTBS) of resin-modified glass ionomer cement (RM-GIC) to sound and artificial caries-affected bovine root dentin (ACAD) using three different conditioning agents were evaluated after 24 hours and three months. The fractured interface was examined with a scanni...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/16-375-L
更新日期:2017-11-01 00:00:00
abstract::Detailed and accurate impressions are made when the oral environment is dry during the impression process. Maintaining a dry field on medically, physically, or emotionally compromised patients can be very challenging. If not achieved, it may compromise dental care and accurate outcomes. This article describes a techni...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/11-290-T
更新日期:2014-01-01 00:00:00
abstract::SmartPrep is a rotating instrument for dentin caries excavation made from a special polymer. The manufacturer's product information stated that SmartPrep removes carious dentin selectively. This in vitro study compared the efficiency of SmartPrep with conventional tungsten carbide bud burs. Fifty extracted teeth were ...
journal_title:Operative dentistry
pub_type: 杂志文章,随机对照试验
doi:10.2341/05-24
更新日期:2006-03-01 00:00:00
abstract::The replacement of a restoration is one of the most common procedures in dentistry. However, the criteria for such intervention, excluding catastrophic failure and persistent discomfort and pain, continue to be the subject of considerable debate. The decision-making process remains subjective on the part of the treati...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/15-058-O
更新日期:2016-09-01 00:00:00
abstract::The purpose of this double-blind clinical trial was to compare the retention rate in noncarious Class V lesions of two resin-based composite restorative materials with contrasting stiffness. Isolation with retraction cord, pressed paper triangles, and cotton rolls was used to closely mimic the procedures generally use...
journal_title:Operative dentistry
pub_type: 临床试验,杂志文章,随机对照试验
doi:
更新日期:2000-01-01 00:00:00
abstract::Four resin based materials (Compolute Aplicap, ESPE; Variolink Ultra, Vivadent; C&B Metabond, Parkell and Panavia 21, Kuraray), two carboxylate cements (Poly-F Plus, Dentsply DeTrey and Durelon Maxicap, ESPE), two glass-ionomer cements (Fuji I, GC and Ketac-Cem Aplicap, ESPE), one resin-modified glass ionomer cement (...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2000-11-01 00:00:00
abstract::This study evaluated the effect of ascorbic acid, 500 mg every eight hours, on bleaching-induced tooth sensitivity. A triple-blind, parallel design, and placebo-controlled randomized clinical trial was conducted on 39 adults. The pills (placebo or ascorbic acid) were administered three times per day for 48 hours; the ...
journal_title:Operative dentistry
pub_type: 杂志文章,随机对照试验
doi:10.2341/12-483-C
更新日期:2014-03-01 00:00:00
abstract:OBJECTIVES:The aim of this investigation was to test the tensile bond strength (TBS) between different computer-aided-design/manufacturing (CAD/CAM) ceramics after conditioning using different universal adhesive systems and resin composite cement. METHODS AND MATERIALS:Substrates of four CAD/CAM ceramics-1) VITABLOCS ...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/18-017-L
更新日期:2019-07-01 00:00:00
abstract::Of the many factors under their control, clinicians can manipulate light-exposure duration but must deal with a set intensity of light emitted from the dental curing unit. This research investigates the interdependence of exposure duration and source intensity on resin cure at various depths within a simulated light-c...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1994-01-01 00:00:00
abstract::This study evaluated the biocompatibility of contemporary bulk-fill resin-based composites (RBCs) including PRG (pre-reacted glass ionomer) materials based on the International Organization for Standardization 10993. In addition, the effect of composite thickness on cytotoxicity was also assessed. Two standard composi...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/15-059-L
更新日期:2015-11-01 00:00:00
abstract::Recently, manufacturers introduced presterilized, single-use, plastic light-curing tips to be used either routinely or on patients with known or questionable communicable health concerns. The purpose of this study was to examine the effect of these single-use tips on light transmission compared to conventional fiber-o...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1998-07-01 00:00:00
abstract::In the direct treatment of cervical lesions and to improve the impression-making procedure prior to fabricating indirect restorations, exposure of the gingival sulcus and control of hemorrhage or gingival fluid seepage are a prerequisite. For gingival displacement, cords impregnated with medicaments are widely used. I...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2002-07-01 00:00:00