Abstract:
PURPOSE:The present study aimed to investigate a novel adhesive system containing 0.2% chlorhexidine digluconate (CHX) for its ability to improve the stability of the adhesive interface compared with the use of 2% CHX as a therapeutic primer. Furthermore, the study aimed to confirm the inhibitory properties of these CHX concentrations (0.2% and 2.0%) on dentin matrix metalloproteinase activity by gelatin zymography. METHODS:Superficial dentin substrate for bonding was obtained from 120 non-carious human molars. A conventional adhesive Peak LC Bond and a CHX-containing adhesive Peak Universal Bond were used either in combination with 35% phosphoric acid (etch-and-rinse approach) or with self-etching primer (self-etch approach) for evaluation of the variables CHX treatment (2.0% therapeutic primer and 0.2% adhesive), adhesive approach (etch-and-rinse and self-etch), and storage time (24 hours and six months). A bonding jig was used to fabricate composite cylinders, which were stored for either 24 hours or six months, after which shear bond strength (SBS) was evaluated using a notched-edge testing device. A three-way analysis of variance and a Student t-test with a significance level of p<0.05 were used to analyze the data. Extracts from concentrated demineralized human dentin powder were subjected to sodium dodecyl sulfate polyacrylamide gel electrophoresis and incubated in the presence of 0.2% and 2.0% CHX. RESULTS:No significant effect of CHX treatment, adhesive approach, storage time variables, or their interactions on mean SBS was demonstrated (p<0.05). No significant difference between the control and the CHX-treated groups was detected for either adhesive technique at 24 hours or six months (p<0.05). No significant variation in mean SBS was detected after six months of storage (p<0.05). Zymographic analysis revealed bands of enzymatic activity for the group demineralized with phosphoric acid and complete inhibition of gelatinolytic activity for the groups treated with 0.2% and 2.0% CHX. CONCLUSIONS:CHX demonstrated inhibition of dentin proteolytic activity. However, when CHX was incorporated into a commercially available adhesive or used as a therapeutic primer, no difference in bond strength was observed at baseline or after six months of storage relative to the control group without CHX.
journal_name
Oper Dentjournal_title
Operative dentistryauthors
Sabatini Cdoi
10.2341/12-239-Lsubject
Has Abstractpub_date
2013-11-01 00:00:00pages
609-17issue
6eissn
0361-7734issn
1559-2863journal_volume
38pub_type
杂志文章,随机对照试验abstract::This study compared the post-gel contraction of two "low-shrinkage" composites (InTen-S [IS], Ivoclar-Vivadent; Aelite LS [AL], BISCO Inc) and an ormocer (Admira [AM], Voco) to two conventional mini-filled composites (Renew [RN], BISCO; Z100 [ZO], 3M ESPE). A strain-monitoring device and test configuration were used t...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2004-03-01 00:00:00
abstract::This study examined the relationship between the bond agent application duration and the dentin bond strength of several single-application bonding systems. The restorative material/ bonding systems used were Reactmer, with its single-application bonding system Reactmer Bond (RB, Shofu Inc, Kyoto, Japan); Palfique Est...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2002-05-01 00:00:00
abstract:PURPOSE:To investigate the influence of ferrule thickness on fracture resistance after mechanical cycling of teeth restored with different intracanal posts. METHODS AND MATERIALS:One hundred twenty bovine incisor teeth were randomized into six study groups, based on the intracanal post used (fiber post or cast post an...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/18-241-L
更新日期:2019-11-01 00:00:00
abstract::This study evaluated the effect of two dentin disinfectants (Consepsis, Tubulicid), one aqueous HEMA solution (Aqua Prep), a combination of Aqua Prep and Tubulicid and an air abrasion treatment (50 microns aluminum oxide) on the shear bond strength (SBS) of two acetone-based single bottle adhesives (One Step and Prime...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2001-11-01 00:00:00
abstract::This in vitro study investigated the correlation between factors related to cavosurface marginal adaptation and microleakage in Class II cavities restored with a light- or chemical-activated resin composite. Standardized cavities were prepared in 40 molars that were randomly divided between both materials. Each of the...
journal_title:Operative dentistry
pub_type: 杂志文章,随机对照试验
doi:10.2341/06-16
更新日期:2007-01-01 00:00:00
abstract::On occasion we receive manuscripts that we would like to publish, but do not have the page room to include in the print journal. For the full article, please go to www.jopdentonline.org or enter the provided address into your address bar. ...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/1559-2863-42.6.680
更新日期:2017-11-01 00:00:00
abstract::This study evaluated the biocompatibility of contemporary bulk-fill resin-based composites (RBCs) including PRG (pre-reacted glass ionomer) materials based on the International Organization for Standardization 10993. In addition, the effect of composite thickness on cytotoxicity was also assessed. Two standard composi...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/15-059-L
更新日期:2015-11-01 00:00:00
abstract::A literature review was conducted on adhesive Class I and II restorations and nondestructive in vitro tests using the PubMed/Medline database for the 1995-2010 period. The first part of this review has presented and critically appraised selected literature dealing with the quality and in vitro behavior of adhesive Cla...
journal_title:Operative dentistry
pub_type: 杂志文章,评审
doi:10.2341/12-020B-LIT
更新日期:2013-09-01 00:00:00
abstract::Post-operative sensitivity (POS) may be observed in recently placed posterior composites. Evidence-based guidelines for the management of posterior composites with POS have yet to be determined. This study examined a retrospective analysis of the findings of a unique multi-center clinical trial to investigate the five...
journal_title:Operative dentistry
pub_type: 临床试验,杂志文章,多中心研究
doi:
更新日期:2003-11-01 00:00:00
abstract::This study compared the slice method of measuring microleakage to the whole-wall method. Forty-eight Class V direct metal restorations were placed in the buccal and lingual surfaces of 24 human molars. Following thermocycling and storage in 2% methylene blue stain for 12 hours, the teeth were sectioned and the restora...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2002-11-01 00:00:00
abstract:OBJECTIVE:The aim of this study was to evaluate the two-year clinical performance of Class III, IV, and V composite restorations using a two-step etch-and-rinse adhesive system (2-ERA) and three one-step self-etching adhesive systems (1-SEAs). MATERIAL AND METHODS:Two hundred Class III, IV, and V composite restoration...
journal_title:Operative dentistry
pub_type: 杂志文章,随机对照试验
doi:10.2341/11-397-C
更新日期:2013-05-01 00:00:00
abstract::The reasons for placement and replacement and the longevity of amalgam restorations were recorded by 62 Italian private practitioners. The survey compiled 1935 amalgam restorations inserted due to primary caries (59%) and failed restorations (41%). The clinical diagnosis of secondary caries constituted 59% of failures...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1992-03-01 00:00:00
abstract::This study investigated the effect of nonrinse conditioners (ie, Ketac Nano Primer [KNP] and GC Self Conditioner [SC]) used as substrate pretreatment and their respective paste-paste resin-modified glass-ionomer cement (RMGIC) (ie, Ketac Nano [KN] and Fuji Filling LC [FF]) on microtensile bond strength to dentin and m...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/14-030-L
更新日期:2015-05-01 00:00:00
abstract::Good wettability is one of the desirable physical properties of mercury-free gallium-based alloys (Gallium Alloy GF). However, wettability, while providing good adhesion to the cavity wall, has the adverse effect of causing stickiness to the inside of the capsule during mixing, and also to the metal hand instruments u...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1996-01-01 00:00:00
abstract::This study investigated the influence of different light sources associated with a transdental photoactivation technique on the marginal adaptation and hardness of composite restorations. Cavities (3 mm wide x 3 mm long x 1.5 mm in deep) were prepared on flattened bovine dentin and filled with Z250 composite (3M ESPE)...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/07-109
更新日期:2008-07-01 00:00:00
abstract:PURPOSE:The aim of this study was to evaluate the effect of low-thickness ceramic laminate translucency on water sorption and solubility in resin luting agents. METHODS AND MATERIALS:Ceramic slides (15×0.7 mm) were generated using lithium disilicate (IPS e.max Press, Ivoclar-Vivadent, Schaan, Liechtenstein) that were ...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/15-201-L
更新日期:2016-09-01 00:00:00
abstract::Various core materials with different shades affect the final color of high-translucency monolithic zirconia restorations. The blue core shows the greatest color difference in final zirconia restorations followed by metal, A3 dentin-shade resin core, and white core. ...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/19-238-L
更新日期:2020-12-21 00:00:00
abstract:CLINICAL RELEVANCE:Using a material that optimizes marginal seal when using a margin elevation technique to manage deep class II cavities should enhance clinical outcomes. SUMMARY:Objectives: The purpose of this laboratory study was to perform a tridimensional interfacial gap evaluation of class II cavities with ename...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/19-161-L
更新日期:2020-09-01 00:00:00
abstract::This investigation examined the susceptibility to staining and translucency changes of some new tooth-colored restorative materials after immersion in different beverages. The materials studied were 3M Filtek Z350XT (ZT), 3M Filtek 350XT Flowable Restorative (ZF), Shofu Beautifil Flow Plus (BF), Shofu Beautifil II (B2...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/149027-L
更新日期:2015-03-01 00:00:00
abstract::One hundred non-carious, non-undercut cervical lesions were restored with Silux Plus or Estio LC and bonded with Fuji Bond LC. The restorations were evaluated yearly for retention and marginal discoloration. After five years, the overall retention rate was 96%. Of the 41 restorations examined at five years, five had c...
journal_title:Operative dentistry
pub_type: 临床试验,杂志文章
doi:
更新日期:2002-09-01 00:00:00
abstract::This in vitro study investigated the possible dehydration of dentin caused by bleaching agents. Furthermore, it tested whether protective dentin varnishes can maintain the physiological moisture of dentin during bleaching treatment. Fifty-five standardized dentin cylinders were prepared from freshly extracted bovine i...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/05-89
更新日期:2006-09-01 00:00:00
abstract::This study investigated the reasons for placement and replacement of dental restorations in the United States Navy Dental Corps. The relationship between restoration longevity and the reasons for replacement of restorations was also studied. Data on newly placed dental restorations were collected from restorative dent...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1993-09-01 00:00:00
abstract::The purpose of this study was to determine if the actual concentration of bleaching agents available in four different countries were the same as the label indicated and within the recommendations of the International Standard on Tooth Whitening. The method recommended for assaying peroxide by the United States Pharma...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/11-367-L
更新日期:2013-05-01 00:00:00
abstract::The steady increase in online health information seeking by patients is ingrained in central notions of patient-centered care and shared decision-making models reflected in operative dentistry and the healthcare industry at large. More patients today seek health information prior to an appointment, communicate their f...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/14-312-LIT
更新日期:2015-09-01 00:00:00
abstract:OBJECTIVES::To evaluate the effect of a remineralizing gel combining fluoride and calcium silicate/phosphate or a sodium fluoride gel on bleached enamel microhardness, color, and wear susceptibility. METHODS AND MATERIALS::Two hundred forty bovine enamel-dentin samples were prepared. Baseline analysis of Knoop microha...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/17-150-L
更新日期:2019-01-01 00:00:00
abstract::The available and proposed methods for determining the in vivo occlusal wear values of classes 1 and 2 restorations made of resinfilled composite materials are critically reviewed. A methodology to be used to address the fundamental question of the link between the wear of the in vivo restorations and the relevant mec...
journal_title:Operative dentistry
pub_type: 杂志文章,评审
doi:
更新日期:1991-03-01 00:00:00
abstract::Detailed and accurate impressions are made when the oral environment is dry during the impression process. Maintaining a dry field on medically, physically, or emotionally compromised patients can be very challenging. If not achieved, it may compromise dental care and accurate outcomes. This article describes a techni...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/11-290-T
更新日期:2014-01-01 00:00:00
abstract:OBJECTIVES::The use of high-viscosity glass-ionomer cements (HVGICs) for atraumatic restorative treatment (ART) restorations is widely practiced with the advent of various HVGICs. However, the bonding of the latter to caries-affected dentin (CAD) should be validated, especially because it is the common substrate left a...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/17-154-L
更新日期:2018-11-01 00:00:00
abstract::This study investigated the microleakage associated with the repair of non-carious amalgam defects using flowable resin composite. Occlusal amalgam preparations were accomplished on 36 non-carious mandibular molars. A standardized 40-micron marginal defect was made by condensing amalgam against a mylar matrix strip. S...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2001-05-01 00:00:00
abstract::Standardized class 4 cavities were prepared in bovine incisors and restored with a microfilled composite resin. The composite restorations were retained either by acid etching technique (AET) alone or by acid etching technique in combination with a self-threading retentive pin. Pins covered with a bonding/opaquer coat...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1994-05-01 00:00:00