Transdental photo-activation technique: hardness and marginal adaptation of composite restorations using different light sources.

Abstract:

:This study investigated the influence of different light sources associated with a transdental photoactivation technique on the marginal adaptation and hardness of composite restorations. Cavities (3 mm wide x 3 mm long x 1.5 mm in deep) were prepared on flattened bovine dentin and filled with Z250 composite (3M ESPE). Nine groups (n=10) were defined according to the curing technique (direct; transdental--photo-activation through 1 mm of enamel and 2 mm of dentin; mixed--transdental + direct) and light source (QTH XL2500, 3M ESPE; PAC Apollo 95E, DMD; LED Ultrablue Is, DMC) combination. Marginal adaptation was evaluated using a dye staining method, and the percentage of stained margins was recorded. Knoop Hardness readings were made across the transversal section of the fillings. Data were submitted to two-way ANOVA and Tukey's test (p< or =0.05). For margin analysis, although none of the curing conditions provided perfect adaptation, the mixed technique showed lower gap formation. No significant differences were detected between the transdental and other techniques, and no significant differences were detected among the light sources. For hardness, the direct technique showed slightly greater hardness than the mixed technique. Also, the mixed technique yielded greater hardness than the transdental technique. Among the light sources, the LED showed greater hardness than the PAC; whereas, no significant differences between the QTH and other sources were detected. The mixed technique might improve the marginal adaptation of restorations, while not being detrimental to composite hardness.

journal_name

Oper Dent

journal_title

Operative dentistry

authors

Alves EB,Alonso RC,Correr GM,Correr AB,de Moraes RR,Sinhoreti MA,Correr-Sobrinho L

doi

10.2341/07-109

subject

Has Abstract

pub_date

2008-07-01 00:00:00

pages

421-5

issue

4

eissn

0361-7734

issn

1559-2863

journal_volume

33

pub_type

杂志文章
  • The influence of surface standardization of lithium disilicate glass ceramic on bond strength to a dual resin cement.

    abstract::In vitro studies to assess bond strength between resins and ceramics have used surfaces that have been ground flat to ensure standardization; however, in patients, ceramic surfaces are irregular. The effect of a polished and unpolished ceramic on bond strength needs to be investigated. Sixty ceramic specimens (20×5×2 ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/11-009-L

    authors: Brum R,Mazur R,Almeida J,Borges G,Caldas D

    更新日期:2011-09-01 00:00:00

  • Longevity of low- and high-copper amalgams analyzed by preparation class, tooth site, patient age, and operator.

    abstract::The purpose of this study was to compare the long-term survivals of two low-copper and three high-copper amalgam alloys, and to analyze four clinical factors for their possible effects on the restoration survivals. Some 1476 polished restorations were placed in hospital patients by a large number of operators and asse...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Smales RJ

    更新日期:1991-09-01 00:00:00

  • Analysis of the degree of conversion of LED and halogen lights using micro-Raman spectroscopy.

    abstract::This study determined the degree of conversion of two LED (light-emitting diodes) (Elipar FreeLight [FL], 3M ESPE; GC e-Light [EL], GC), a high intensity (Elipar TriLight [TL], 3M ESPE) and a very high intensity (Astralis 10 [AS], Ivoclar Vivadent) halogen light. The degree of conversion of these lights was compared t...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Soh MS,Yap AU,Yu T,Shen ZX

    更新日期:2004-09-01 00:00:00

  • Degree of conversion and hardness of a silorane-based composite resin: effect of light-curing unit and depth.

    abstract:PURPOSE:To investigate the effect of different light-curing units and depths on the degree of conversion (DC) through Fourier transform infrared spectroscopy (FTIR) and Knoop Hardness Number (KHN) of a silorane-based composite resin (Filtek LS, 3M ESPE, St Paul, MN, USA) (LS). MATERIALS AND METHODS:LS specimens mounte...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/12-479

    authors: Torres SA,Silva GC,Maria DA,Campos WR,Magalhães CS,Moreira AN

    更新日期:2014-05-01 00:00:00

  • Comparison of two methods of measuring dye penetration in restoration microleakage studies.

    abstract::This study compared the slice method of measuring microleakage to the whole-wall method. Forty-eight Class V direct metal restorations were placed in the buccal and lingual surfaces of 24 human molars. Following thermocycling and storage in 2% methylene blue stain for 12 hours, the teeth were sectioned and the restora...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Williams PT,Schramke D,Stockton L

    更新日期:2002-11-01 00:00:00

  • Review of the effectiveness of various tooth whitening systems.

    abstract::This review compares nine published studies conducted at the Indiana University School of Dentistry. Twenty-five products in four different systems were evaluated using the Trubyte Bioform Color Ordered Shade Guide and a Chroma Meter. The dentist-prescribed overnight bleaching delta mean shade guide value (DSGV) 10 we...

    journal_title:Operative dentistry

    pub_type: 杂志文章,评审

    doi:10.2341/08-74

    authors: Matis BA,Cochran MA,Eckert G

    更新日期:2009-03-01 00:00:00

  • Effect of a chlorhexidine-containing adhesive on dentin bond strength stability.

    abstract:PURPOSE:The present study aimed to investigate a novel adhesive system containing 0.2% chlorhexidine digluconate (CHX) for its ability to improve the stability of the adhesive interface compared with the use of 2% CHX as a therapeutic primer. Furthermore, the study aimed to confirm the inhibitory properties of these CH...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/12-239-L

    authors: Sabatini C

    更新日期:2013-11-01 00:00:00

  • Chromatic influence of value resin composites.

    abstract::The current study evaluated the chromatic influence of high, medium and low value composites on a dentin composite substrate (A2 shade) using spectrophotometric analysis. The specimens were divided into the following four groups: a) control (CG), entirely composed of dentin composite (n = 5); b) high value (GHV), dent...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/09-44-L

    authors: Schmeling M,Meyer-Filho A,de Andrada MA,Baratieri LN

    更新日期:2010-01-01 00:00:00

  • Influence of light energy density on effectiveness of composite cure.

    abstract::This study investigated the influence of light energy density (intensity x time) on the effectiveness of composite cure in view of the curing profiles of new light-polymerization units. This investigation used a digital microhardness tester to evaluate the hardness of the top/bottom surfaces and hardness ratio of 2 mm...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Yap AU,Seneviratne C

    更新日期:2001-09-01 00:00:00

  • The shear bond strength between luting cements and zirconia ceramics after two pre-treatments.

    abstract::This study evaluated the shear-bond strength of 11 luting cements from different material classes to manufactured pre-treated zirconia ceramics (Lava: 97% ZrO2, stabilized with 3% Y2O3). In addition, the influence of the curing method on shear-bond strength was investigated. The cements examined were one zinc-phosphat...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Piwowarczyk A,Lauer HC,Sorensen JA

    更新日期:2005-05-01 00:00:00

  • Two-year clinical performance of a polyacid-modified resin composite and a resin-modified glass-ionomer restorative material.

    abstract::This study compared the clinical performance of a polyacid-modified resin composite and a resin-modified glass-ionomer restorative material over two years. Thirty-four pairs of restorations of Compoglass and Fuji II LC were placed in caries-free cervical erosion/abfraction lesions without tooth preparation. Restoratio...

    journal_title:Operative dentistry

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:

    authors: Brackett WW,Browning WD,Ross JA,Brackett MG

    更新日期:2001-01-01 00:00:00

  • The Effect of Phosphoric Acid Pre-etching Times on Bonding Performance and Surface Free Energy with Single-step Self-etch Adhesives.

    abstract:OBJECTIVE:The purpose of this study was to evaluate the effect of phosphoric acid pre-etching times on shear bond strength (SBS) and surface free energy (SFE) with single-step self-etch adhesives. METHODS:The three single-step self-etch adhesives used were: 1) Scotchbond Universal Adhesive (3M ESPE), 2) Clearfil tri-S...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/15-221-L

    authors: Tsujimoto A,Barkmeier WW,Takamizawa T,Latta MA,Miyazaki M

    更新日期:2016-07-01 00:00:00

  • Effect of eugenol-containing temporary cements on bond strength of composite to enamel.

    abstract::The purpose of this study was to find out the degree to which eugenol-containing temporary cements or temporary filling materials affected shear bond strength of a dual-cure resin luting cement to acid-etched enamel. For this purpose 56 human caries-free third molars were embedded in acrylic resin and cross sectioned ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Jung M,Ganss C,Senger S

    更新日期:1998-03-01 00:00:00

  • Fracture Toughness Analysis of Ceramic and Resin Composite CAD/CAM Material.

    abstract:OBJECTIVES:To evaluate and compare the fracture toughness of dental CAD/CAM materials of different material classes intended for in-office milling (glass ceramics, hybrid, resin composites) and the influence of aging on this property. METHODS AND MATERIALS:The fracture toughness (critical intensity factor, KIc) values...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/18-161-L

    authors: Hampe R,Theelke B,Lümkemann N,Eichberger M,Stawarczyk B

    更新日期:2019-07-01 00:00:00

  • Rigidity and retention of ceramic root canal posts.

    abstract::Ceramic root-canal posts offer potential advantages over other types with respect to aesthetics and biocompatibility. Any post must be sufficiently rigid and retentive to withstand functional forces. Ceraposts (1.2 mm coronal diameter, ceramic, tapering, smooth posts) and Paraposts (1.25 mm, stainless-steel, parallel,...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Purton DG,Love RM,Chandler NP

    更新日期:2000-05-01 00:00:00

  • Multidisciplinary Treatment of Complicated Crown-Root Fractures: A Case Study.

    abstract::Traumatic dental injuries usually occur among children and adolescents, with maxillary central incisors as the most often affected teeth. Complicated crown-root fractures are particularly challenging for esthetic and functional rehabilitation and often require a multidisciplinary approach. A 21-year-old male patient c...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/15-080-T

    authors: Stojanac IL,Bajkin BV,Premovic MT,Ramic BD,Petrovic LM

    更新日期:2016-11-01 00:00:00

  • Combination of Acetaminophen/Codeine Analgesics Does Not Avoid Bleaching-Induced Tooth Sensitivity: A Randomized, Triple-Blind Two-Center Clinical Trial.

    abstract::Bleaching-induced tooth sensitivity (TS) is highly prevalent. OBJECTIVE:This study aimed to determine if the combination of opioids and nonopioids analgesics (Tylex) may provide a better analgesic effect. METHOD:A triple-blind, parallel, randomized two-center clinical trial was conducted with 105 healthy patients wh...

    journal_title:Operative dentistry

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.2341/17-092-C

    authors: Coppla FM,Rezende M,de Paula E,Farago PV,Loguercio AD,Kossatz S,Reis A

    更新日期:2018-03-01 00:00:00

  • Effect of Polishing Systems on Surface Roughness and Topography of Monolithic Zirconia.

    abstract::This study evaluated the effect of different chairside polishing systems on the surface roughness and topography of monolithic zirconia. Thirty-five monolithic zirconia specimens (Lava PLUS, 3M ESPE) were fabricated and divided into five groups of seven and polished with the following: Group 1 (WZ)-Dura white stone fo...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/15-064-L

    authors: Goo CL,Yap A,Tan K,Fawzy AS

    更新日期:2016-07-01 00:00:00

  • Microshear Bond Strength of High-viscosity Glass-ionomer to Normal and Caries-affected Dentin Under Simulated Intrapulpal Pressure.

    abstract:OBJECTIVES::The use of high-viscosity glass-ionomer cements (HVGICs) for atraumatic restorative treatment (ART) restorations is widely practiced with the advent of various HVGICs. However, the bonding of the latter to caries-affected dentin (CAD) should be validated, especially because it is the common substrate left a...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/17-154-L

    authors: El-Deeb HA,Mobarak EH

    更新日期:2018-11-01 00:00:00

  • Prospective Clinical Study of Zirconia Full-coverage Restorations on Teeth Prepared With Biologically Oriented Preparation Technique on Gingival Health: Results After Two-year Follow-up.

    abstract:OBJECTIVES:To evaluate the clinical behavior of one-piece complete-coverage crowns and fixed partial dentures (FPDs) on teeth with vertical preparation without finish line biologically oriented preparation technique (BOPT). METHODS AND MATERIALS:This prospective study included 52 patients requiring treatment with rest...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/17-124-C

    authors: Agustín-Panadero R,Serra-Pastor B,Fons-Font A,Solá-Ruíz MF

    更新日期:2018-09-01 00:00:00

  • Fit of veneers made by CAD-CAM and platinum foil methods.

    abstract::Veneers were fabricated by CEREC CAD-CAM and the platinum foil techniques for standardized preparations on 10 artificial teeth. Mesial preparation contacts were broken, but distal contacts remained intact. The veneers were cemented in a standardized manner to their teeth. The veneers and their attached cement were emb...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Suh PS,Johnson R,White SN

    更新日期:1997-05-01 00:00:00

  • Influence of Nd:YAG laser irradiation on an adhesive restorative procedure.

    abstract::Hard tissue modification by means of laser irradiation is becoming popular in dentistry, since it promotes assorted responses between the tooth and the restorative material. Some studies on the bond strength of adhesive systems to Nd:YAG irradiated teeth have shown distinctive behaviors when irradiation was applied be...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/05-110

    authors: Franke M,Taylor AW,Lago A,Fredel MC

    更新日期:2006-09-01 00:00:00

  • Antibacterial activity of various self-etching adhesive systems against oral streptococci.

    abstract::The antibacterial properties of self-etching adhesive systems constitute an important issue in operative dentistry, since viable bacteria can still be present after cavity preparation. The current study evaluated the antibacterial activity of five one-step self-etching adhesives (SEAs) and four self-etching primers (S...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/09-297-L

    authors: Esteves CM,Ota-Tsuzuki C,Reis AF,Rodrigues JA

    更新日期:2010-07-01 00:00:00

  • Effect of cleansing methods on saliva-contaminated zirconia--an evaluation of resin bond durability.

    abstract::The aims of this study were to investigate 1) the influence of cleansing methods after saliva contamination and 2) aging conditions (thermocycling and water storage) on zirconia shear bond strength (SBS) with a resin cement. One hundred and eighty zirconia specimens were sandblasted with 50 μm aluminum oxide particles...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/13-323-L

    authors: Feitosa SA,Patel D,Borges AL,Alshehri EZ,Bottino MA,Özcan M,Valandro LF,Bottino MC

    更新日期:2015-03-01 00:00:00

  • Effect of Ferrule Thickness on Fracture Resistance of Teeth Restored With a Glass Fiber Post or Cast Post.

    abstract:PURPOSE:To investigate the influence of ferrule thickness on fracture resistance after mechanical cycling of teeth restored with different intracanal posts. METHODS AND MATERIALS:One hundred twenty bovine incisor teeth were randomized into six study groups, based on the intracanal post used (fiber post or cast post an...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/18-241-L

    authors: Fontana PE,Bohrer TC,Wandscher VF,Valandro LF,Limberger IF,Kaizer OB

    更新日期:2019-11-01 00:00:00

  • Curing of pit & fissure sealants using Light Emitting Diode curing units.

    abstract::Light Emitting Diode (LED) curing units are attractive to clinicians, because most are cordless and should create less heat within tooth structure. However, questions about polymerization efficacy have surrounded this technology. This research evaluated the adequacy of the depth of cure of pit & fissure sealants provi...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Platt JA,Clark H,Moore BK

    更新日期:2005-11-01 00:00:00

  • Ceramic Veneers for Esthetic Restoration of Retained Primary Teeth: A 4-year Follow-up Case Report.

    abstract::Retained primary teeth in the smile zone can cause patient dissatisfaction, especially if associated with malposition of teeth. Orthodontic and prosthetic treatment options to treat the situation may not be accepted by some patients. Therefore, these patients tend to maintain their primary teeth and seek different est...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/15-363-S

    authors: Bin-Shuwaish MS

    更新日期:2017-03-01 00:00:00

  • Composite cure and shrinkage associated with high intensity curing light.

    abstract::This study investigated the effectiveness of cure and post-gel shrinkage of three visible light-cured composite resins (In Ten-S [IT], Ivoclar Vivadent; Z100 [ZO], 3M-ESPE; Tetric Ceram [TC], Ivoclar Vivadent) when polymerized with a very high intensity (1296 +/- 2 mW/cm2) halogen light (Astralis 10, Ivoclar Vivadent)...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Yap AU,Wong NY,Siow KS

    更新日期:2003-07-01 00:00:00

  • Pulpal effects of composite resin restorations.

    abstract::This article reviews the literature concerning the pulpal effects of composite resin restorations. A number of aspects are addressed, including the composite resin materials themselves, bacterial leakage, acid-etch technique, and dentin bonding procedures. Guidelines for pulpal protection are discussed. ...

    journal_title:Operative dentistry

    pub_type: 杂志文章,评审

    doi:

    authors: Swift EJ Jr

    更新日期:1989-01-01 00:00:00

  • Cumulative assessment of factors leading to restorative decisions in an educational environment. A graphical demonstration using an in vitro case.

    abstract::Even though accuracy and inter-examiner variation assessments of borderline restorative items have been previously reported, no attempt has been made to replicate the effect of cumulative, sequential diagnostic and treatment planning decisions. This study assesses the cumulative effect of factors indicating restorativ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Maupomé G

    更新日期:2000-07-01 00:00:00