Fit of veneers made by CAD-CAM and platinum foil methods.

Abstract:

:Veneers were fabricated by CEREC CAD-CAM and the platinum foil techniques for standardized preparations on 10 artificial teeth. Mesial preparation contacts were broken, but distal contacts remained intact. The veneers were cemented in a standardized manner to their teeth. The veneers and their attached cement were embedded in epoxy resin and sectioned twice gingivally-incisally and mesially-distally to produce eight sections. Three-way ANOVA disclosed that the main effects of fabrication method, section location, and measurement point location as well as all interaction terms significantly affected fit (P < 0.05). However, the difference in mean overall fit between the fabrication methods was too small to be of clinical importance. Restoration of the broken approximal contact did not compromise fit. Incisal margins had the greatest marginal openings. Surface measurement point locations were less well adapted than internal locations. Fit maps for CEREC and platinum foil veneers were strikingly similar.

journal_name

Oper Dent

journal_title

Operative dentistry

authors

Suh PS,Johnson R,White SN

subject

Has Abstract

pub_date

1997-05-01 00:00:00

pages

121-7

issue

3

eissn

0361-7734

issn

1559-2863

journal_volume

22

pub_type

杂志文章
  • Nanoleakage at the dentin adhesive interface vs microtensile bond strength.

    abstract::Excessive etching of the dentin may decrease bond strength because the adhesive may fail to completely infiltrate to the base of the over-etched demineralized collagen network. The purpose of the present study was to evaluate the influence of increasing etching times on the microtensile bond strength of Single Bond an...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Paul SJ,Welter DA,Ghazi M,Pashley D

    更新日期:1999-05-01 00:00:00

  • Adherence of plaque components to different restorative materials.

    abstract::This study compared the amount of artificial plaque synthesized in vitro by Streptococcus sobrinus on various dental materials using radioisotopes. In particular, plaque-retaining capacities of new types of ceramics were the focus of this study. Specimens were fabricated from the following materials (one amalgam alloy...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Kawai K,Urano M

    更新日期:2001-07-01 00:00:00

  • Degradation of Computer-aided Design/Computer-aided Manufacturing Composites by Dietary Solvents: An Optical Three-dimensional Surface Analysis.

    abstract:CLINICAL RELEVANCE:Computer-aided design/computer-aided manufacturing (CAD/CAM) composite resins are susceptible to degradation by dietary solvents. Dietary counselling is prudent when placing such CAD/CAM restorations. SUMMARY:This study determined the effect of dietary solvents on the surface roughness (Ra) of direc...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/19-070-L

    authors: Munusamy SM,Yap AU,Ching HL,Yahya NA

    更新日期:2020-07-01 00:00:00

  • The effect of various surface coatings on fluoride release from glass-ionomer cement.

    abstract::To protect glass-ionomer cement from moisture contamination and dehydration during initial setting, immediate application of a surface coating agent is recommended. This study compared the effect of various surface coatings on F release from glass-ionomer cement. Twenty glass-ionomer cement (Ketac Fil Aplicap) disks (...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Castro GW,Gray SE,Buikema DJ,Reagan SE

    更新日期:1994-09-01 00:00:00

  • Restoration deterioration related to later failure.

    abstract::The purpose of this study was to determine the relationship between the deterioration and the later failure of a very large number of amalgams and anterior resin composites examined over periods of up to 16 years. Assessments were made of the deterioration of various clinical factors or characteristics of the restorat...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Smales RJ,Webster DA

    更新日期:1993-07-01 00:00:00

  • Effect of light activation mode on the incompatibility between one-bottle adhesives and light-cured composites: an in vitro shear bond strength study.

    abstract::This study examined the effect of different light activation modes for light-cured resin-based composites on the shear bond strength to dentin of two one-bottle adhesives with differing acidity. In this experimental study, a flat middle dentin surface was prepared on 110 extracted sound molars using a 600-grit polish ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/08-048-L

    authors: Shafiei F,Saffarpour A,Moradmand M,Alavi AA

    更新日期:2009-09-01 00:00:00

  • Bonding of Adhesive Luting Agents to Caries-affected Dentin Induced by a Microcosm Biofilm Model.

    abstract:OBJECTIVES:To evaluate the bond strength of adhesive luting agents applied to caries-affected dentin (CAD). METHODS:Thirty-six noncarious human third molars were abraded to expose an occlusal dentin surface. Caries lesions were induced in half of the samples using a microcosm biofilm model. Biofilm was cultivated unde...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/14-169-L

    authors: Peixoto AC,Bicalho AA,Isolan CP,Maske TT,Moraes RR,Cenci MS,Soares CJ,Faria-e-Silva AL

    更新日期:2015-05-01 00:00:00

  • Cumulative assessment of factors leading to restorative decisions in an educational environment. A graphical demonstration using an in vitro case.

    abstract::Even though accuracy and inter-examiner variation assessments of borderline restorative items have been previously reported, no attempt has been made to replicate the effect of cumulative, sequential diagnostic and treatment planning decisions. This study assesses the cumulative effect of factors indicating restorativ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Maupomé G

    更新日期:2000-07-01 00:00:00

  • A simplified clinical technique for a routine indirect restoration impression on a challenging patient using a dry field illuminator.

    abstract::Detailed and accurate impressions are made when the oral environment is dry during the impression process. Maintaining a dry field on medically, physically, or emotionally compromised patients can be very challenging. If not achieved, it may compromise dental care and accurate outcomes. This article describes a techni...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/11-290-T

    authors: Santucci NM,Santucci ET,Geissberger M

    更新日期:2014-01-01 00:00:00

  • Cytotoxicity evaluation of single component dentin bonding agents.

    abstract::This study evaluated the cytotoxicity of four single component dentin bonding agents: Syntac Single Component, Prime & Bond 2.1, Single Bond and One Up Bond F. The test materials were applied on dentin discs of dentin barrier models in the same way as in the clinical procedures recommended by each manufacturer. Cell v...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Vajrabhaya LO,Pasasuk A,Harnirattisai C

    更新日期:2003-07-01 00:00:00

  • Grinding With Diamond Burs and Hydrothermal Aging of a Y-TZP Material: Effect on the Material Surface Characteristics and Bacterial Adhesion.

    abstract::The aim of this study was to evaluate the effect of grinding with diamond burs and low-temperature aging on the material surface characteristics and bacteria adhesion on a yttrium-stabilized tetragonal zirconia polycrystalline (Y-TZP) surface. Y-TZP specimens were made from presintered blocks, sintered as recommended ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/16-108-L

    authors: Dutra D,Pereira G,Kantorski KZ,Exterkate R,Kleverlaan CJ,Valandro LF,Zanatta FB

    更新日期:2017-11-01 00:00:00

  • Two-year clinical performance of self-etching adhesive systems in composite restorations of anterior teeth.

    abstract:OBJECTIVE:The aim of this study was to evaluate the two-year clinical performance of Class III, IV, and V composite restorations using a two-step etch-and-rinse adhesive system (2-ERA) and three one-step self-etching adhesive systems (1-SEAs). MATERIAL AND METHODS:Two hundred Class III, IV, and V composite restoration...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/11-397-C

    authors: Barcellos DC,Batista GR,Silva MA,Pleffken PR,Rangel PM,Fernandes VV Jr,Di Nicoló R,Torres CR

    更新日期:2013-05-01 00:00:00

  • Step-cure polymerization: effect of initial light intensity on resin/dentin bond strength in class I cavities.

    abstract::This in vitro study assessed the effect of a step-cure light curing method on resin/dentin bond strength on the buccal wall of Class I cavities in human teeth. Occlusal enamel was removed to expose a flat dentin surface. Twenty four box-shaped cavities (C-factor = 4.5) were prepared in dentin. Prime&Bond 2.1 was appli...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/05-37

    authors: Santos AJ,Sarmento CF,Abuabara A,Aguiar FH,Lovadino JR

    更新日期:2006-05-01 00:00:00

  • Enamel wetness effects on bond strength using different adhesive systems.

    abstract:OBJECTIVE:To evaluate, through the application of different dentin bonding systems, the influence of wetness on shear bond strength in enamel. METHODS:This study evaluated three etch-and-rinse adhesive systems (Scotchbond MP [used with and without primer]; Singlebond; and Prime&Bond 2.1) and two self-etching adhesive ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/10-163-L

    authors: Furuse AY,Cunha LF,Moresca R,Paganeli G,Mondelli RF,Mondelli J

    更新日期:2011-05-01 00:00:00

  • Tridimensional Evaluation of the Interfacial Gap in Deep Cervical Margin Restorations: A Micro-CT Study.

    abstract:CLINICAL RELEVANCE:Using a material that optimizes marginal seal when using a margin elevation technique to manage deep class II cavities should enhance clinical outcomes. SUMMARY:Objectives: The purpose of this laboratory study was to perform a tridimensional interfacial gap evaluation of class II cavities with ename...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/19-161-L

    authors: Scotti N,Baldi A,Vergano EA,Tempesta RM,Alovisi M,Pasqualini D,Carpegna GC,Comba A

    更新日期:2020-09-01 00:00:00

  • Nanofilled Resin Composite Properties and Clinical Performance: A Review.

    abstract::The aim of this review was to compile recent evidence related to nanofilled resin composite materials regarding the properties and clinical performance. Special attention was given to mechanical properties, such as strength, hardness, abrasive wear, water sorption, and solubility. The clinical performance of nanocompo...

    journal_title:Operative dentistry

    pub_type: 杂志文章,评审

    doi:10.2341/17-208-T

    authors: Alzraikat H,Burrow MF,Maghaireh GA,Taha NA

    更新日期:2018-07-01 00:00:00

  • In vivo examination of the Scotchbond Multi-Purpose Dental Adhesive System in rat (vitalmicroscopic study).

    abstract::No data are available on the direct acute vascular effect of dental bonding materials on the dental pulp. This study investigated the effects of the components of a composite resin-bonding system on pulpal vascular diameter. Three groups of 10 male Sprague-Dawley rats (weighing 330 +/- 51 g) were used for this investi...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Iványi I,Balogh AE,Rosivall L,Nyárasdy I

    更新日期:2000-09-01 00:00:00

  • Transdental photo-activation technique: hardness and marginal adaptation of composite restorations using different light sources.

    abstract::This study investigated the influence of different light sources associated with a transdental photoactivation technique on the marginal adaptation and hardness of composite restorations. Cavities (3 mm wide x 3 mm long x 1.5 mm in deep) were prepared on flattened bovine dentin and filled with Z250 composite (3M ESPE)...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/07-109

    authors: Alves EB,Alonso RC,Correr GM,Correr AB,de Moraes RR,Sinhoreti MA,Correr-Sobrinho L

    更新日期:2008-07-01 00:00:00

  • Enamel bond strengths of pairs of adhesives from the same manufacturer.

    abstract::Most manufacturers of dental adhesives have both a total-etch adhesive and a simplified self-etching adhesive available on the market. This study measured the enamel microtensile bond strengths of five pairs of enamel adhesives as a function of enamel roughness. The proximal surfaces of 25 extracted mandibular molars ...

    journal_title:Operative dentistry

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:

    authors: Perdigão J,Gomes G,Duarte S Jr,Lopes MM

    更新日期:2005-07-01 00:00:00

  • Effects of delayed polishing on gap formation of cervical restorations.

    abstract::This study evaluated the effect of polishing after one-day storage in water on the gap formation around a Class V restoration completely bordered by enamel (coronal cavity) using one resin-modified glass ionomer, one compomer and one conventional glass ionomer as a control. The study also examined gap formation of the...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Irie M,Suzuki K

    更新日期:2002-01-01 00:00:00

  • Treatment of Dentin Hypersensitivity Using Nano-Hydroxyapatite Pastes: A Randomized Three-Month Clinical Trial.

    abstract:OBJECTIVES:This randomized clinical trial tested the three-month desensitizing effect of two protocols using nano-hydroxyapatite formulations compared with Pro-Argin and fluoride varnish. METHODS:Twenty-eight subjects with 137 teeth presenting dentin exposure with a minimal hypersensitivity of four on the visual analo...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/15-145-C

    authors: Wang L,Magalhães AC,Francisconi-Dos-Rios LF,Calabria MP,Araújo D,Buzalaf M,Lauris J,Pereira JC

    更新日期:2016-07-01 00:00:00

  • Online Only Articles.

    abstract::On occasion we receive manuscripts that we would like to publish, but do not have the page room to include in the print journal. For the full article, please go to www.jopdentonline.org or enter the provided address into your address bar. ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/1559-2863-43.3.335

    authors:

    更新日期:2018-05-01 00:00:00

  • Effect of Ferrule Thickness on Fracture Resistance of Teeth Restored With a Glass Fiber Post or Cast Post.

    abstract:PURPOSE:To investigate the influence of ferrule thickness on fracture resistance after mechanical cycling of teeth restored with different intracanal posts. METHODS AND MATERIALS:One hundred twenty bovine incisor teeth were randomized into six study groups, based on the intracanal post used (fiber post or cast post an...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/18-241-L

    authors: Fontana PE,Bohrer TC,Wandscher VF,Valandro LF,Limberger IF,Kaizer OB

    更新日期:2019-11-01 00:00:00

  • Effect of mechanical properties of resin composites on the efficacy of the dentin bonding system.

    abstract::This study determined the relationship between marginal adaptation to dentin cavity preparations, tensile bond strength of the restorations, and mechanical properties of the composites. Contraction gaps, tensile bond strengths, flexural strengths, and Young's modulus of eight commercial resin composites were determine...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Hasegawa T,Itoh K,Koike T,Yukitani W,Hisamitsu H,Wakumoto S,Fujishima A

    更新日期:1999-11-01 00:00:00

  • Factors associated with microleakage in Class II resin composite restorations.

    abstract::This in vitro study investigated the correlation between factors related to cavosurface marginal adaptation and microleakage in Class II cavities restored with a light- or chemical-activated resin composite. Standardized cavities were prepared in 40 molars that were randomly divided between both materials. Each of the...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/06-16

    authors: Idriss S,Abduljabbar T,Habib C,Omar R

    更新日期:2007-01-01 00:00:00

  • Clinical comparison of bur- and laser-prepared minimally invasive occlusal resin composite restorations: two-year follow-up.

    abstract::This study evaluated the two-year clinical performance of two minimally invasive cavity preparation techniques, bur and laser, in Class I occlusal resin composite restorations. Twenty-seven patients, each having at least one pair of occlusal caries, were enrolled in this study. For each patient, one of the cavities wa...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/09-339-C

    authors: Yazici AR,Baseren M,Gorucu J

    更新日期:2010-09-01 00:00:00

  • The influence of surface standardization of lithium disilicate glass ceramic on bond strength to a dual resin cement.

    abstract::In vitro studies to assess bond strength between resins and ceramics have used surfaces that have been ground flat to ensure standardization; however, in patients, ceramic surfaces are irregular. The effect of a polished and unpolished ceramic on bond strength needs to be investigated. Sixty ceramic specimens (20×5×2 ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/11-009-L

    authors: Brum R,Mazur R,Almeida J,Borges G,Caldas D

    更新日期:2011-09-01 00:00:00

  • A clinical study on interdental separation techniques.

    abstract::The effect of interdental separation of a special separation ring and wooden wedge was investigated. In a split-mouth design, 27 patients were randomly assigned to one of two groups (W or S). In 11 patients, an interdental wooden wedge (Hawe-Neos) was placed (group W), and in 16 patients, a separation ring (Composi-Ti...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/06-73

    authors: Loomans BA,Opdam NJ,Bronkhorst EM,Roeters FJ,Dörfer CE

    更新日期:2007-05-01 00:00:00

  • Rigidity and retention of ceramic root canal posts.

    abstract::Ceramic root-canal posts offer potential advantages over other types with respect to aesthetics and biocompatibility. Any post must be sufficiently rigid and retentive to withstand functional forces. Ceraposts (1.2 mm coronal diameter, ceramic, tapering, smooth posts) and Paraposts (1.25 mm, stainless-steel, parallel,...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Purton DG,Love RM,Chandler NP

    更新日期:2000-05-01 00:00:00

  • The effect of distance and tooth structure on laser fluorescence caries detection.

    abstract::The DIAGNOdent, a device used in caries detection, uses a laser to excite fluorescence from pigments in carious tooth structure. In clinical use assessing occlusal surfaces, distance and tooth structure may separate the instrument's tip from the fluorescent source.The aim of this in vitro study was to examine the effe...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/10-179-L

    authors: Markowitz K,Stenvall RM,Graye M

    更新日期:2012-03-01 00:00:00