The effect of distance and tooth structure on laser fluorescence caries detection.

Abstract:

:The DIAGNOdent, a device used in caries detection, uses a laser to excite fluorescence from pigments in carious tooth structure. In clinical use assessing occlusal surfaces, distance and tooth structure may separate the instrument's tip from the fluorescent source.The aim of this in vitro study was to examine the effect of distance and tooth structure on laser fluorescence (LF) readings.In one set of experiments, a porphyrin pigmentin oil suspension was used as a LF signal source. Thin slices of enamel and dentin were obtained from extracted molars. Pigment-induced LF readings were obtained when these slices were placed between the porphyrin pigment and the LF instrument's tip. The effect of either demineralized or intact tooth tissue on pigment-induced LF readings was assessed.In other experiments on extracted molars with small occlusal caries, LF readings were taken from pit/fissure sites before and after removal of the occlusal surface.LF readings are proportional to pigment con-centration and inversely proportional to the distance between the suspension and the instrument's tip. Enamel, demineralized enamel,dentin, and demineralized dentin all caused significant reductions in LF signal, all readings being taken with the same tip-pigment distance. Demineralized enamel (white with intact surface) caused the most reduction.After sectioning of carious teeth, there was a significant increase in LF readings.The results of this study indicate that distance and the presence of tooth structure between the carious lesion and the instrument's tip reduce LF readings. These results indicate that anatomic factors interfere with the LF device's ability to assess occlusal caries. DIAGNOdent readings should not be relied on when making diagnostic decisions.

journal_name

Oper Dent

journal_title

Operative dentistry

authors

Markowitz K,Stenvall RM,Graye M

doi

10.2341/10-179-L

subject

Has Abstract

pub_date

2012-03-01 00:00:00

pages

150-60

issue

2

eissn

0361-7734

issn

1559-2863

journal_volume

37

pub_type

杂志文章
  • Adhesive Cementation Promotes Higher Fatigue Resistance to Zirconia Crowns.

    abstract:OBJECTIVE:The aim of this study was to investigate the influence of the cementation strategy on the fatigue resistance of zirconia crowns. The null hypothesis was that the cementation strategy would not affect the fatigue resistance of the crowns. METHODS AND MATERIALS:Seventy-five simplified molar tooth crown prepara...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/16-002-L

    authors: Campos F,Valandro LF,Feitosa SA,Kleverlaan CJ,Feilzer AJ,de Jager N,Bottino MA

    更新日期:2017-03-01 00:00:00

  • Antibacterial activity of dentin bonding systems, resin-modified glass ionomers, and polyacid-modified composite resins.

    abstract::The antibacterial effects of the dentin bonding systems Syntac, ProBOND, Gluma 3-Step, the resin-modified glass ionomers Photac-Fil, Fuji Lining LC, Fuji II LC, and the polyacid-modified composite resins VariGlass, Geristore, and Infinity were evaluated using the cariogenic bacteria S mutans, L salivarius, S sobrinus,...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Meiers JC,Miller GA

    更新日期:1996-11-01 00:00:00

  • Influence of Conditioning Time of Universal Adhesives on Adhesive Properties and Enamel-Etching Pattern.

    abstract:OBJECTIVES:To evaluate the effect of application protocol in resin-enamel microshear bond strength (μSBS), in situ degree of conversion, and etching pattern of three universal adhesive systems. METHODS AND MATERIALS:Sixty-three extracted third molars were sectioned in four parts (buccal, lingual, and proximals) and di...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/15-213-L

    authors: Cardenas AM,Siqueira F,Rocha J,Szesz AL,Anwar M,El-Askary F,Reis A,Loguercio A

    更新日期:2016-09-01 00:00:00

  • Light-emitting Diode Beam Profile and Spectral Output Influence on the Degree of Conversion of Bulk Fill Composites.

    abstract:OBJECTIVES:To evaluate the beam profile and the spectral output of monowave and polywave light-emitting diodes (LEDs) and their influence on the degree of conversion (DC) of bulk fill composites. METHODS:A monowave LED (Smartlite Focus, Dentsply) and a polywave LED (Valo Cordless, Ultradent) were characterized using a...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/16-164-L

    authors: Rocha MG,de Oliveira D,Correa IC,Correr-Sobrinho L,Sinhoreti M,Ferracane JL,Correr AB

    更新日期:2017-07-01 00:00:00

  • Relationship between nanoleakage and microtensile bond strength at the resin-dentin interface.

    abstract::To evaluate the correlation between microtensile dentin bond strength (microTBS) and silver ion penetration, two total-etch 3-step and one self-etch 2-step system were investigated. OptiBond FL adhesive was applied to flat occlusal dentin on six non-carious human molars, and a resin composite "crown" was formed in 2 m...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Guzmán-Armstrong S,Armstrong SR,Qian F

    更新日期:2003-01-01 00:00:00

  • Post-gel shrinkage strain and degree of conversion of preheated resin composite cured using different regimens.

    abstract:OBJECTIVES:This study investigated the influence of resin composite preheating temperature, light curing regimen (mode and duration) on post-gel shrinkage strain (PGSS) and degree of conversion (DC) of a restorative resin composite. METHODS:A hybrid resin composite preheated to three different temperatures (37 degrees...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/09-072-L

    authors: El-Korashy DI

    更新日期:2010-03-01 00:00:00

  • Marginal adaptation of dental composites containing prepolymerized filler.

    abstract::Marginal adaptation to cylindrical dentin preparations of five commercially available dental composites--Charisma, Estelite, Herculite, Pertac, and Silux Plus--and seven experimental dental composites containing prepolymerized filler was evaluated by measurement of the wall-to-wall polymerization contraction gaps. The...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Yukitani W,Hasegawa T,Itoh K,Hisamitsu H,Wakumoto S

    更新日期:1997-11-01 00:00:00

  • The effect of light curing source on the residual yellowing of resin composites.

    abstract:PURPOSE:This study evaluated the amount of residual yellow in cured resin composites when polymerizing with either a quartz-tungsten-halogen (QTH) or blue light-emitting diode (LED). MATERIAL AND METHODS:Twelve shades (bleaching to conventional shades) of microfill, hybrid and microhybrid resin composite specimens (n ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/06-129

    authors: Brackett MG,Brackett WW,Browning WD,Rueggeberg FA

    更新日期:2007-09-01 00:00:00

  • Nanofilled Resin Composite Properties and Clinical Performance: A Review.

    abstract::The aim of this review was to compile recent evidence related to nanofilled resin composite materials regarding the properties and clinical performance. Special attention was given to mechanical properties, such as strength, hardness, abrasive wear, water sorption, and solubility. The clinical performance of nanocompo...

    journal_title:Operative dentistry

    pub_type: 杂志文章,评审

    doi:10.2341/17-208-T

    authors: Alzraikat H,Burrow MF,Maghaireh GA,Taha NA

    更新日期:2018-07-01 00:00:00

  • The effect of air abrasion with two new bonding agents on composite repair.

    abstract::This study evaluated the shear bond strength of repairs made with a composite (Herculite/Kerr) when two different surface treatment methods and two new generation bond materials were used. The bonding surfaces were prepared by sanding with 500-grit aluminum oxide sandpaper or air abrading with 25-micron aluminum oxide...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Oztas N,Alaçam A,Bardakçy Y

    更新日期:2003-03-01 00:00:00

  • Analysis of the degree of conversion of LED and halogen lights using micro-Raman spectroscopy.

    abstract::This study determined the degree of conversion of two LED (light-emitting diodes) (Elipar FreeLight [FL], 3M ESPE; GC e-Light [EL], GC), a high intensity (Elipar TriLight [TL], 3M ESPE) and a very high intensity (Astralis 10 [AS], Ivoclar Vivadent) halogen light. The degree of conversion of these lights was compared t...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Soh MS,Yap AU,Yu T,Shen ZX

    更新日期:2004-09-01 00:00:00

  • Criteria for the Replacement of Restorations: Academy of Operative Dentistry European Section.

    abstract::The replacement of a restoration is one of the most common procedures in dentistry. However, the criteria for such intervention, excluding catastrophic failure and persistent discomfort and pain, continue to be the subject of considerable debate. The decision-making process remains subjective on the part of the treati...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/15-058-O

    authors: Wilson N,Lynch CD,Brunton PA,Hickel R,Meyer-Lueckel H,Gurgan S,Pallesen U,Shearer AC,Tarle Z,Cotti E,Vanherle G,Opdam N

    更新日期:2016-09-01 00:00:00

  • Effect of fractured or sectioned fragments on the fracture strength of different reattachment techniques.

    abstract::This study evaluated the effect of fractured or sectioned fragments on the fracture strength recovery of four techniques used for reattachment and resin composite buildups. Ninety-one sound, permanent lower central incisors were used. Half the teeth were fractured in the incisal-proximal edge; the other half had the i...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Loguercio AD,Mengarda J,Amaral R,Kraul A,Reis A

    更新日期:2004-05-01 00:00:00

  • Sudden Onset of Subcutaneous Air Emphysema After the Application of Air to a Maxillary Premolar Located in a Nonsurgical Field.

    abstract::Although rare, subcutaneous air emphysema can occur during dental procedures such as endodontic treatment, surgical extractions, and preparing a tooth for an indirect or direct dental restoration. We report the development of a subcutaneous air emphysema that was introduced through the periodontal ligament of an untre...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/15-155-S

    authors: Van Tubergen EA,Tindle D,Fox GM

    更新日期:2017-09-01 00:00:00

  • Marginal and internal adaptation of bulk-filled Class I and Cuspal coverage direct resin composite restorations.

    abstract::This in vitro study compared the marginal and internal adaptation of bulk-filled Class I and cuspal coverage direct resin composite restorations filled with different types of adhesive restorative systems and different thicknesses of bonding agent. Seventy-two intact, caries-free, freshly extracted human molars were r...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/06-157

    authors: Stavridakis MM,Kakaboura AI,Ardu S,Krejci I

    更新日期:2007-09-01 00:00:00

  • Lesion Activity Assessment (LAA) in Conjunction With International Caries Detection and Assessment System (ICDAS) for Occlusal Caries Diagnosis in Permanent Teeth.

    abstract:OBJECTIVE:The aim of this study was to investigate the clinical performance and to validate the Lesion Activity Assessment (LAA) in conjunction with the International Caries Detection and Assessment System (ICDAS) for occlusal caries diagnosis in permanent teeth. METHODS:Patients with erupted or partially erupted thir...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/13-332-C

    authors: Cotta F,de Castilho LS,Moreira AN,Paiva SM,Ferreira EF,Ferreira LC,Magalhães CS

    更新日期:2015-09-01 00:00:00

  • Review of the effectiveness of various tooth whitening systems.

    abstract::This review compares nine published studies conducted at the Indiana University School of Dentistry. Twenty-five products in four different systems were evaluated using the Trubyte Bioform Color Ordered Shade Guide and a Chroma Meter. The dentist-prescribed overnight bleaching delta mean shade guide value (DSGV) 10 we...

    journal_title:Operative dentistry

    pub_type: 杂志文章,评审

    doi:10.2341/08-74

    authors: Matis BA,Cochran MA,Eckert G

    更新日期:2009-03-01 00:00:00

  • The effect of sandblasting and different primers on shear bond strength between yttria-tetragonal zirconia polycrystal ceramic and a self-adhesive resin cement.

    abstract:PURPOSE:To evaluate the effect of zirconia primers, air-abrasion, and tribochemical surface treatment methods on the shear bond strength between yttria-tetragonal zirconia polycrystal (Y-TZP) ceramic and self-adhesive resin cement. METHODS AND MATERIALS:Y-TZP ceramic surfaces were ground flat with 600-grit silicon car...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/13-149-L

    authors: Yi YA,Ahn JS,Park YJ,Jun SH,Lee IB,Cho BH,Son HH,Seo DG

    更新日期:2015-01-01 00:00:00

  • Endodontic Access Effect on Full Contour Zirconia and Lithium Disilicate Failure Resistance.

    abstract:OBJECTIVES:To evaluate the effect of endodontic access on the failure load resistance of both adhesively and conventionally luted, full-contour monolithic yttria-stabilized zirconium dioxide (Y-TZP) and adhesively luted lithium disilicate (LD) crowns cemented on prepared teeth. METHODS AND MATERIALS:Seventy-two human ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/18-231-L

    authors: Mallya J,DuVall N,Brewster J,Roberts H

    更新日期:2020-05-01 00:00:00

  • Degradation of Computer-aided Design/Computer-aided Manufacturing Composites by Dietary Solvents: An Optical Three-dimensional Surface Analysis.

    abstract:CLINICAL RELEVANCE:Computer-aided design/computer-aided manufacturing (CAD/CAM) composite resins are susceptible to degradation by dietary solvents. Dietary counselling is prudent when placing such CAD/CAM restorations. SUMMARY:This study determined the effect of dietary solvents on the surface roughness (Ra) of direc...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/19-070-L

    authors: Munusamy SM,Yap AU,Ching HL,Yahya NA

    更新日期:2020-07-01 00:00:00

  • Two-year clinical performance of a polyacid-modified resin composite and a resin-modified glass-ionomer restorative material.

    abstract::This study compared the clinical performance of a polyacid-modified resin composite and a resin-modified glass-ionomer restorative material over two years. Thirty-four pairs of restorations of Compoglass and Fuji II LC were placed in caries-free cervical erosion/abfraction lesions without tooth preparation. Restoratio...

    journal_title:Operative dentistry

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:

    authors: Brackett WW,Browning WD,Ross JA,Brackett MG

    更新日期:2001-01-01 00:00:00

  • Inactivation of matrix-bound matrix metalloproteinases by cross-linking agents in acid-etched dentin.

    abstract:OBJECTIVES:Published transmission electron microscopy analysis of in vitro resin-dentin bonds shows that, after 44 months, almost 70% of collagen fibrils from the hybrid layer disappear. Matrix metalloproteinases (MMPs) play an important role in that process and are thought to be the main factor responsible for the sol...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/12-425-L

    authors: Scheffel DL,Hebling J,Scheffel RH,Agee K,Turco G,de Souza Costa CA,Pashley D

    更新日期:2014-03-01 00:00:00

  • Efficacy of mouth rinses and toothpaste on tooth whitening.

    abstract:OBJECTIVES:People increasingly desire tooth whitening. Considering the wide range of whitening products on the market, this study evaluated the efficacy of whitening toothpastes and mouth rinses compared with the 10% carbamide peroxide (CP) whitening gel. METHODS:We obtained 120 cylindrical specimens from bovine teeth...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/11-360-L

    authors: Torres CR,Perote LC,Gutierrez NC,Pucci CR,Borges AB

    更新日期:2013-01-01 00:00:00

  • Fluoride release from fluoride-containing materials.

    abstract::This in vitro study evaluated the amount of fluoride released from fluoride-containing materials over a period of 28 days. Six disk samples (2.06 +/- 0.06 cm2) were prepared of each material and divided at random into seven groups: Group 1: Chelon-Fil; Group 2: Chelon-Silver; Group 3: VariGlass; Group 4: Dyract; Group...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: de Araujo FB,García-Godoy F,Cury JA,Conceição EN

    更新日期:1996-09-01 00:00:00

  • Caries-preventive activity of fluoride-containing resin-based desensitizers.

    abstract:OBJECTIVE:The purpose of this study was to evaluate the effects of different desensitizing agents on the prevention of root caries when applied to root surfaces. MATERIALS AND METHODS:Thirty human roots were sectioned into quarters with a 3 × 4 mm window. A desensitizer (VX, Clinpro™ XT Varnish; SP, Seal & Protect®; o...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/11-007-L

    authors: Sohn S,Yi K,Son HH,Chang J

    更新日期:2012-05-01 00:00:00

  • Placement and replacement of amalgam restorations in Italy.

    abstract::The reasons for placement and replacement and the longevity of amalgam restorations were recorded by 62 Italian private practitioners. The survey compiled 1935 amalgam restorations inserted due to primary caries (59%) and failed restorations (41%). The clinical diagnosis of secondary caries constituted 59% of failures...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Mjör IA,Toffenetti F

    更新日期:1992-03-01 00:00:00

  • Transdental photo-activation technique: hardness and marginal adaptation of composite restorations using different light sources.

    abstract::This study investigated the influence of different light sources associated with a transdental photoactivation technique on the marginal adaptation and hardness of composite restorations. Cavities (3 mm wide x 3 mm long x 1.5 mm in deep) were prepared on flattened bovine dentin and filled with Z250 composite (3M ESPE)...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/07-109

    authors: Alves EB,Alonso RC,Correr GM,Correr AB,de Moraes RR,Sinhoreti MA,Correr-Sobrinho L

    更新日期:2008-07-01 00:00:00

  • Assessing the surface roughness of a posterior resin composite: effect of surface sealing.

    abstract::This study assessed the in vitro influence of surface sealing on the surface roughness of a posterior resin composite before and after toothbrushing. Thirty specimens (13 mm diameter x 1 mm high) were fabricated from Filtek-P60 resin composite and randomly assigned to three groups (n = 10): a non-sealed control and tw...

    journal_title:Operative dentistry

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:

    authors: Takeuchi CY,Orbegoso Flores VH,Palma Dibb RG,Panzeri H,Lara EH,Dinelli W

    更新日期:2003-05-01 00:00:00

  • Efficacy of a Light-cured Tetracaine-based Anesthetic Gel for Rubber Dam Clamp Placement: A Triple-blind Randomized Clinical Trial.

    abstract:OBJECTIVES:To evaluate the efficacy of a new light-cured anesthetic gel for pain control in adults undergoing rubber dam isolation for the restorative treatment of noncarious cervical lesions (NCCLs). METHODS AND MATERIALS:This study was a randomized, split-mouth, triple-blind, controlled trial. The sample comprised 5...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/18-130-C

    authors: Wambier LM,Gonzaga CC,Chibinski A,Wambier DS,Farago PV,Loguercio AD,Reis A

    更新日期:2020-03-01 00:00:00

  • Microtensile Bond Strength of Composite Cement to Novel CAD/CAM Materials as a Function of Surface Treatment and Aging.

    abstract:OBJECTIVES:To evaluate the effect of different surface treatments on the bond strength to a composite and a polymer-infiltrated ceramic CAD/CAM block after six-month artificial aging. METHODS AND MATERIALS:Two types of CAD/CAM blocks (Cerasmart, GC; Enamic, Vita Zahnfabrik) were cut in slabs of 4-mm thickness, divided...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/15-263-L

    authors: Lise DP,Van Ende A,De Munck J,Vieira L,Baratieri LN,Van Meerbeek B

    更新日期:2017-01-01 00:00:00