Relationship between nanoleakage and microtensile bond strength at the resin-dentin interface.

Abstract:

:To evaluate the correlation between microtensile dentin bond strength (microTBS) and silver ion penetration, two total-etch 3-step and one self-etch 2-step system were investigated. OptiBond FL adhesive was applied to flat occlusal dentin on six non-carious human molars, and a resin composite "crown" was formed in 2 mm increments. After 24-hour water storage, the teeth were sectioned with a low-speed diamond saw to obtain four-square sticks (approximately 2 mm X 2 mm) per tooth. Cylindrical tensile test specimens were formed with an 0.5 mm2 cross-sectional area. Nail varnish was applied to the dentin within 0.5-1.0 mm of the interface before immersing in 50% silver nitrate for 15 minutes. Following silver fixation, tensile testing was performed in a Zwick UTM at 1 mm/minute using a passive gripping fixture to obtain 72-hour microTBS [23.9 MPa]. The percentage area of silver penetration was measured on debonded specimens using light microscopy and Image-Pro Plus Software [89%]. The procedures were repeated using Scotchbond Multi-Purpose Plus [microTBS = 27.8 MPa; nanoleakage = 67%] and Clearfil SE bond [microTBS = 36 MPa; nanoleakage = 55%]. No significant correlation between microtensile bond strength and nanoleakage was found for all systems. A weak-to-moderate negative relationship was found between microTBS and nanoleakage for OptiBond FL (Spearman r = -0.3844). No correlation was found for the remaining adhesive systems. The correlation between these two common laboratory measurements appears to be adhesive-system dependent.

journal_name

Oper Dent

journal_title

Operative dentistry

authors

Guzmán-Armstrong S,Armstrong SR,Qian F

keywords:

subject

Has Abstract

pub_date

2003-01-01 00:00:00

pages

60-6

issue

1

eissn

0361-7734

issn

1559-2863

journal_volume

28

pub_type

杂志文章
  • Effect of composite resin contamination with powdered and unpowdered latex gloves on its shear bond strength to bovine dentin.

    abstract::The aim of the present study was to evaluate the effect of composite resin contamination with powdered and unpowdered latex gloves on the shear bond strength of etch-and-rinse and two-step self-etch adhesive systems. Standard flat dentin surfaces were prepared on the facial aspect of 120 bovine incisors and randomly a...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/11-088-L

    authors: Oskoee SS,Navimipour EJ,Bahari M,Ajami AA,Oskoee PA,Abbasi NM

    更新日期:2012-09-01 00:00:00

  • Effect of fractured or sectioned fragments on the fracture strength of different reattachment techniques.

    abstract::This study evaluated the effect of fractured or sectioned fragments on the fracture strength recovery of four techniques used for reattachment and resin composite buildups. Ninety-one sound, permanent lower central incisors were used. Half the teeth were fractured in the incisal-proximal edge; the other half had the i...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Loguercio AD,Mengarda J,Amaral R,Kraul A,Reis A

    更新日期:2004-05-01 00:00:00

  • Efficacy of a Light-cured Tetracaine-based Anesthetic Gel for Rubber Dam Clamp Placement: A Triple-blind Randomized Clinical Trial.

    abstract:OBJECTIVES:To evaluate the efficacy of a new light-cured anesthetic gel for pain control in adults undergoing rubber dam isolation for the restorative treatment of noncarious cervical lesions (NCCLs). METHODS AND MATERIALS:This study was a randomized, split-mouth, triple-blind, controlled trial. The sample comprised 5...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/18-130-C

    authors: Wambier LM,Gonzaga CC,Chibinski A,Wambier DS,Farago PV,Loguercio AD,Reis A

    更新日期:2020-03-01 00:00:00

  • A suggested method for mixing direct filling restorative gallium alloy.

    abstract::Good wettability is one of the desirable physical properties of mercury-free gallium-based alloys (Gallium Alloy GF). However, wettability, while providing good adhesion to the cavity wall, has the adverse effect of causing stickiness to the inside of the capsule during mixing, and also to the metal hand instruments u...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Momoi Y,Asami Y,Ozawa M,Kohno A

    更新日期:1996-01-01 00:00:00

  • Review of the effectiveness of various tooth whitening systems.

    abstract::This review compares nine published studies conducted at the Indiana University School of Dentistry. Twenty-five products in four different systems were evaluated using the Trubyte Bioform Color Ordered Shade Guide and a Chroma Meter. The dentist-prescribed overnight bleaching delta mean shade guide value (DSGV) 10 we...

    journal_title:Operative dentistry

    pub_type: 杂志文章,评审

    doi:10.2341/08-74

    authors: Matis BA,Cochran MA,Eckert G

    更新日期:2009-03-01 00:00:00

  • The use of resin composite pins to improve retention of Class IV resin composite restorations.

    abstract::This study evaluated the effect of an intracoronal resin composite pin on Class IV resin composite restorations. A control group of 16 bovine teeth was prepared with standardized conventional Class IV preparations. For an experimental group, 16 similar Class IV preparations were made, with the addition of an intracoro...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Roberts HW,Hermesch CB,Charlton DG

    更新日期:2000-07-01 00:00:00

  • Reversal of dentin bonding to bleached teeth.

    abstract::Many studies have shown a considerable reduction in enamel bond strength of resin composite restorations when the bonding procedure is carried out immediately after bleaching. These studies claim that a certain waiting period is needed prior to restoration to reach the original bond strength values prior to bleaching....

    journal_title:Operative dentistry

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:

    authors: Kaya AD,Türkün M

    更新日期:2003-11-01 00:00:00

  • Endodontic Access Effect on Full Contour Zirconia and Lithium Disilicate Failure Resistance.

    abstract:OBJECTIVES:To evaluate the effect of endodontic access on the failure load resistance of both adhesively and conventionally luted, full-contour monolithic yttria-stabilized zirconium dioxide (Y-TZP) and adhesively luted lithium disilicate (LD) crowns cemented on prepared teeth. METHODS AND MATERIALS:Seventy-two human ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/18-231-L

    authors: Mallya J,DuVall N,Brewster J,Roberts H

    更新日期:2020-05-01 00:00:00

  • Nanoleakage at the dentin adhesive interface vs microtensile bond strength.

    abstract::Excessive etching of the dentin may decrease bond strength because the adhesive may fail to completely infiltrate to the base of the over-etched demineralized collagen network. The purpose of the present study was to evaluate the influence of increasing etching times on the microtensile bond strength of Single Bond an...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Paul SJ,Welter DA,Ghazi M,Pashley D

    更新日期:1999-05-01 00:00:00

  • Chromatic influence of value resin composites.

    abstract::The current study evaluated the chromatic influence of high, medium and low value composites on a dentin composite substrate (A2 shade) using spectrophotometric analysis. The specimens were divided into the following four groups: a) control (CG), entirely composed of dentin composite (n = 5); b) high value (GHV), dent...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/09-44-L

    authors: Schmeling M,Meyer-Filho A,de Andrada MA,Baratieri LN

    更新日期:2010-01-01 00:00:00

  • Bonding ability of paste-paste glass ionomer systems to tooth structure: in vitro studies.

    abstract::This study investigated the effect of nonrinse conditioners (ie, Ketac Nano Primer [KNP] and GC Self Conditioner [SC]) used as substrate pretreatment and their respective paste-paste resin-modified glass-ionomer cement (RMGIC) (ie, Ketac Nano [KN] and Fuji Filling LC [FF]) on microtensile bond strength to dentin and m...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/14-030-L

    authors: Cook NB,Feitosa SA,Patel A,Alfawaz Y,Eckert GJ,Bottino MC

    更新日期:2015-05-01 00:00:00

  • Effect of Conventional and Acid-modified Casein Phosphopeptide-Amorphous Calcium Phosphate Crèmes on Dentin Permeability Before and After Acid Challenge.

    abstract::This study investigated the effect of conventional and acidified casein phosphopeptide-amorphous calcium phosphate-containing crèmes (CPP-ACP and ACPP-ACP) on dentin permeability (DP) before and after acid challenge, using a fluid-flow measuring device and scanning electron microscopic (SEM) examination. Fifty dentin ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/17-382-L

    authors: Kijsamanmith K,Banomyong D,Burrow MF,Kanchanasantikul P,Wipawiwat S,Srikam S,Laojarungphesatchakorn S

    更新日期:2019-09-01 00:00:00

  • Effect of Minocycline on the Durability of Dentin Bonding Produced with Etch-and-Rinse Adhesives.

    abstract:OBJECTIVES:To evaluate the effect of minocycline and chlorhexidine pretreatment of acid-etched dentin on the longevity of resin-dentin bond strength (μTBS) and nanoleakage of two-step etch-and-rinse adhesives. METHODS:Before application of Prime & Bond NT and Adper Single Bond 2 in occlusal dentin, the dentin surfaces...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/15-023-L

    authors: Loguercio AD,Stanislawczuk R,Malaquias P,Gutierrez MF,Bauer J,Reis A

    更新日期:2016-09-01 00:00:00

  • Composite photopolymerization with diode laser.

    abstract::Under clinical conditions, the time needed for the proper light curing of luting composites or the multi-incremental buildup of a large restoration with halogen curing units is quite extensive. Due to the development of high power curing devices, such as argon lasers and plasma arc lights and, in order to decrease cur...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/06-79

    authors: Knezevic A,Ristic M,Demoli N,Tarle Z,Music S,Negovetic Mandic V

    更新日期:2007-05-01 00:00:00

  • The effect of energy application sequence on the microtensile bond strength of different C-factor cavity preparations.

    abstract::This study investigated the effect of three equivalent radiant exposure energy application sequences (EASs): high intensity power (HIP: 1,177 mW/cm2, 40 seconds), low intensity power (LOP: 573 mW/cm2, 71 seconds) and ramp (RMP: 650 mW/cm2, 5 seconds, then the irradiance increases to 1047 mW/cm2, 37 seconds) on the mic...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/06-30

    authors: Maghaireh G,Bouschlicher MR,Qian F,Armstrong SR

    更新日期:2007-03-01 00:00:00

  • Effect of Thermocycling, Degree of Conversion, and Cavity Configuration on the Bonding Effectiveness of All-in-One Adhesives.

    abstract::The aim of this study was to compare five all-in-one bonding agents with respect to microleakage, microtensile bond strength (μTBS), degree of conversion (DC) and the impact of cavity configuration. The materials tested were Adper Easy Bond, Clearfil S3 Bond, iBond, Optibond All-in-One, Xeno IV, and Adper Single Bond ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/14-185-LR1

    authors: El-Damanhoury HM,Gaintantzopoulou M

    更新日期:2015-09-01 00:00:00

  • Microleakage and marginal hybrid layer formation of compomer restorations.

    abstract::The tested hypotheses of this study were that dentin enamel bonding agents (DBAs) proposed for compomers create a hybrid layer (HL) that seals the margins of Class V restorations and HL is free from voids or gaps on both enamel and dentin margins. For purposes of this study, Class V restorations (n = 70) were made in ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Prati C,Nucci C,Toledano M,García-Godoy F,Breschi L,Chersoni S

    更新日期:2004-01-01 00:00:00

  • Effect of C-factor on microtensile bond strengths of low-shrinkage composites.

    abstract:UNLABELLED:This study evaluated the microtensile bond strength (μ-TBS) of low-shrinkage composites with their corresponding adhesive systems, Filtek Silorane/Silorane adhesive (SIL, 3M ESPE AG, Seefeld, Germany) and Aelite LS/One-Step Plus (AL, BISCO Inc, Schaumburg, IL, USA) in cavities with different C-factors. Filte...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/10-105-L

    authors: El-Sahn NA,El-Kassas DW,El-Damanhoury HM,Fahmy OM,Gomaa H,Platt JA

    更新日期:2011-05-01 00:00:00

  • Effect of Bleaching Gel Viscosity on Tooth Whitening Efficacy and Pulp Chamber Penetration: An In Vitro Study.

    abstract:OBJECTIVES:Whitening efficacy has been related to hydrogen peroxide (HP) diffusion into tooth structure. However, little information is available relating rheological properties to whitening efficacy. The purpose was to evaluate the whitening efficacy and HP penetration level of a 10% HP gel at three different viscosit...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/17-099-L

    authors: Kwon SR,Pallavi F,Shi Y,Oyoyo U,Mohraz A,Li Y

    更新日期:2018-05-01 00:00:00

  • Influence of adhesive application duration on dentin bond strength of single-application bonding systems.

    abstract::This study examined the relationship between the bond agent application duration and the dentin bond strength of several single-application bonding systems. The restorative material/ bonding systems used were Reactmer, with its single-application bonding system Reactmer Bond (RB, Shofu Inc, Kyoto, Japan); Palfique Est...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Miyazaki M,Tsubota K,Onose H,Hinoura K

    更新日期:2002-05-01 00:00:00

  • Effect of beverages on color and translucency of new tooth-colored restoratives.

    abstract::This investigation examined the susceptibility to staining and translucency changes of some new tooth-colored restorative materials after immersion in different beverages. The materials studied were 3M Filtek Z350XT (ZT), 3M Filtek 350XT Flowable Restorative (ZF), Shofu Beautifil Flow Plus (BF), Shofu Beautifil II (B2...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/149027-L

    authors: Tan BL,Yap AU,Ma HN,Chew J,Tan WJ

    更新日期:2015-03-01 00:00:00

  • Effect of cleansing methods on saliva-contaminated zirconia--an evaluation of resin bond durability.

    abstract::The aims of this study were to investigate 1) the influence of cleansing methods after saliva contamination and 2) aging conditions (thermocycling and water storage) on zirconia shear bond strength (SBS) with a resin cement. One hundred and eighty zirconia specimens were sandblasted with 50 μm aluminum oxide particles...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/13-323-L

    authors: Feitosa SA,Patel D,Borges AL,Alshehri EZ,Bottino MA,Özcan M,Valandro LF,Bottino MC

    更新日期:2015-03-01 00:00:00

  • Microshear Bond Strength of High-viscosity Glass-ionomer to Normal and Caries-affected Dentin Under Simulated Intrapulpal Pressure.

    abstract:OBJECTIVES::The use of high-viscosity glass-ionomer cements (HVGICs) for atraumatic restorative treatment (ART) restorations is widely practiced with the advent of various HVGICs. However, the bonding of the latter to caries-affected dentin (CAD) should be validated, especially because it is the common substrate left a...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/17-154-L

    authors: El-Deeb HA,Mobarak EH

    更新日期:2018-11-01 00:00:00

  • Accuracy of ceramic restorations made using an in-office optical scanning technique: an in vitro study.

    abstract::The present in vitro study concerns determination of the pre-cementation gap width of all-ceramic crowns made using an in-office digital-impression technique and subsequent computer-aided design/computer-aided manufacturing (CAD/CAM) production. Two chairside video camera systems were used: the Lava Oral scanner and C...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/12-309-L

    authors: Tidehag P,Ottosson K,Sjögren G

    更新日期:2014-05-01 00:00:00

  • Effect of Sonic Resin Composite Delivery on Void Formation Assessed by Micro-computed Tomography.

    abstract:OBJECTIVES:The aim of this study was to quantify the internal void volume formation in commercially available, resin composites inserted using conventional or sonic insertion methods, and analyzed using three-dimensional (3D) micro-computed tomography (μCT). METHODS AND MATERIALS:Four resin composites were evaluated: ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/16-331-L

    authors: Hirata R,Pacheco RR,Caceres E,Janal MN,Romero MF,Giannini M,Coelho PG,Rueggeberg FA

    更新日期:2018-03-01 00:00:00

  • Inactivation of matrix-bound matrix metalloproteinases by cross-linking agents in acid-etched dentin.

    abstract:OBJECTIVES:Published transmission electron microscopy analysis of in vitro resin-dentin bonds shows that, after 44 months, almost 70% of collagen fibrils from the hybrid layer disappear. Matrix metalloproteinases (MMPs) play an important role in that process and are thought to be the main factor responsible for the sol...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/12-425-L

    authors: Scheffel DL,Hebling J,Scheffel RH,Agee K,Turco G,de Souza Costa CA,Pashley D

    更新日期:2014-03-01 00:00:00

  • Fluoride release from fluoride-containing materials.

    abstract::This in vitro study evaluated the amount of fluoride released from fluoride-containing materials over a period of 28 days. Six disk samples (2.06 +/- 0.06 cm2) were prepared of each material and divided at random into seven groups: Group 1: Chelon-Fil; Group 2: Chelon-Silver; Group 3: VariGlass; Group 4: Dyract; Group...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: de Araujo FB,García-Godoy F,Cury JA,Conceição EN

    更新日期:1996-09-01 00:00:00

  • The Effect of Resin-modified Glass-ionomer Cement Base and Bulk-fill Resin Composite on Cuspal Deformation.

    abstract:OBJECTIVES:This study investigated cuspal deformation in teeth restored with different types of adhesive materials with and without a base. METHODS:Mesio-occluso-distal slot cavities of moderately large dimension were prepared on extracted maxillary premolars (n=24). Teeth were assigned to one of four groups and resto...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/14-331-L

    authors: Nguyen KV,Wong RH,Palamara J,Burrow MF

    更新日期:2016-03-01 00:00:00

  • Effect of preheating resin composite and light-curing units on the microleakage of Class II restorations submitted to thermocycling.

    abstract::This in vitro study evaluated microleakage in Class II cavities restored with dental composite and varying light-curing units and the temperature of the composite when subjected to a thermocycling test. Ninety cavities were prepared on the proximal surfaces of bovine teeth and randomly divided according to the light-c...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/10-226-LR1

    authors: dos Santos RE,Lima AF,Soares GP,Ambrosano GM,Marchi GM,Lovadino JR,Aguiar FH

    更新日期:2011-01-01 00:00:00

  • Antibacterial activity of various self-etching adhesive systems against oral streptococci.

    abstract::The antibacterial properties of self-etching adhesive systems constitute an important issue in operative dentistry, since viable bacteria can still be present after cavity preparation. The current study evaluated the antibacterial activity of five one-step self-etching adhesives (SEAs) and four self-etching primers (S...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/09-297-L

    authors: Esteves CM,Ota-Tsuzuki C,Reis AF,Rodrigues JA

    更新日期:2010-07-01 00:00:00