Abstract:
:Excessive etching of the dentin may decrease bond strength because the adhesive may fail to completely infiltrate to the base of the over-etched demineralized collagen network. The purpose of the present study was to evaluate the influence of increasing etching times on the microtensile bond strength of Single Bond and the leakage of silver ions within the hybrid layer. After etching occlusal dentin for 15, 30, or 60 seconds with 35% phosphoric acid gel, Single Bond was applied and cured for 10 seconds. Z100 was added and cured for 60 seconds. After 24 hours of water immersion, the teeth were sectioned into slices 0.7 mm thick, and hour-glass-shaped specimens were prepared. Alternate slices were either dried for 30 minutes in air, kept wet, or they were coated with fingernail varnish except for 0.5 mm around the bonded area. Only the varnished samples were then stained with 50% AgNO3. Microtensile bond strength was tested using a Vitrodyne V-1000 universal tester. The samples of the stained group were embedded in self-curing PMMA and polished. All samples were observed with an SEM. Nanoleakage of silver ions was measured by exposure to laser ablation with an inductively connected plasma mass spectrometer and by electron dispersive elemental analysis. Increasing etching times seemed to have a negligible effect on bond strength of Single Bond, producing an average value of ca 38 MPa. However, the silver uptake increased upon prolonged etching times. Short-term results suggest that overetching has no detrimental effect on bond strength values of Single Bond. However, increased silver uptake, depending on the etching time, raises concern about the long-term stability of the bond.
journal_name
Oper Dentjournal_title
Operative dentistryauthors
Paul SJ,Welter DA,Ghazi M,Pashley Dkeywords:
subject
Has Abstractpub_date
1999-05-01 00:00:00pages
181-8issue
3eissn
0361-7734issn
1559-2863journal_volume
24pub_type
杂志文章abstract:CLINICAL RELEVANCE:Computer-aided design/computer-aided manufacturing (CAD/CAM) composite resins are susceptible to degradation by dietary solvents. Dietary counselling is prudent when placing such CAD/CAM restorations. SUMMARY:This study determined the effect of dietary solvents on the surface roughness (Ra) of direc...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/19-070-L
更新日期:2020-07-01 00:00:00
abstract:OBJECTIVES:To evaluate the effect of different surface treatments on the bond strength to a composite and a polymer-infiltrated ceramic CAD/CAM block after six-month artificial aging. METHODS AND MATERIALS:Two types of CAD/CAM blocks (Cerasmart, GC; Enamic, Vita Zahnfabrik) were cut in slabs of 4-mm thickness, divided...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/15-263-L
更新日期:2017-01-01 00:00:00
abstract:OBJECTIVE:The purpose of this study was to evaluate the strengthening effect of resin composite, cured by a modified layering protocol, for teeth with simulated coronal fracture and weakened immature roots. METHODS:Fifty maxillary teeth were decoronated and their apices sectioned to standardize the length to 12 mm. Pr...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/12-525L
更新日期:2014-05-01 00:00:00
abstract::This study evaluated the cytotoxicity of four single component dentin bonding agents: Syntac Single Component, Prime & Bond 2.1, Single Bond and One Up Bond F. The test materials were applied on dentin discs of dentin barrier models in the same way as in the clinical procedures recommended by each manufacturer. Cell v...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2003-07-01 00:00:00
abstract::Standardized class 4 cavities were prepared in bovine incisors and restored with a microfilled composite resin. The composite restorations were retained either by acid etching technique (AET) alone or by acid etching technique in combination with a self-threading retentive pin. Pins covered with a bonding/opaquer coat...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1994-05-01 00:00:00
abstract::This study evaluated the pulp biocompatability of a new light-cured composite resin which was placed in etched glass-ionomer-lined cavities of monkey teeth. The pulpal response to this material was less than that to zinc-oxide eugenol cement in each observation period. Therefore this material seems to meet acceptable ...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1991-07-01 00:00:00
abstract::Most currently marketed fluoride varnishes (FVs) have not been evaluated for their effectiveness in preventing dental caries. The objective of this study was to investigate the anticaries efficacy, measured as fluoride release into artificial saliva (AS); change in surface microhardness of early enamel caries lesions;...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/18-040-L
更新日期:2019-09-01 00:00:00
abstract::Dentin bridging of 150 mechanically exposed monkey pulps to two adhesive resins [BondWell LC (BW); Clearfil Liner Bond II (LB)] and a calcium hydroxide cement [Dycal (DY)] were histopathologically evaluated at 3, 7, 14, 30, and 60 days after operation (n = 10). The dentin bridge structure was three-dimensionally recon...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2000-05-01 00:00:00
abstract:CLINICAL RELEVANCE:When a resin nanoceramic inlay is cemented using self-adhesive cement, a universal dentin adhesive can be applied to the prepared cavity. The application of the adhesive before self-adhesive cement placement provides similar or better interfacial adaptation than without the adhesive. SUMMARY:Purpose...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/19-141-L
更新日期:2020-11-01 00:00:00
abstract:PURPOSE::The purpose of this study was to quantify the relative strength tolerance of 1-day and 30-day amalgam following saturation contamination with water, saliva, blood, and handpiece lubricant oil during condensation. METHODS AND MATERIALS::Valiant PhD XT amalgam was tested with 300 shear-strength (N=15) and 120 c...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/18-091-L
更新日期:2019-03-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to compare the two-year clinical performance of three restorative systems in posterior restorations, which included a low-shrinkage composite and both etch-and-rinse and self-etch adhesive strategies. MATERIALS AND METHODS:After signing an informed consent, 25 patients received thr...
journal_title:Operative dentistry
pub_type: 杂志文章,随机对照试验
doi:10.2341/12-364-C
更新日期:2013-11-01 00:00:00
abstract::The purpose of this study was to determine if the actual concentration of bleaching agents available in four different countries were the same as the label indicated and within the recommendations of the International Standard on Tooth Whitening. The method recommended for assaying peroxide by the United States Pharma...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/11-367-L
更新日期:2013-05-01 00:00:00
abstract:CLINICAL RELEVANCE:The use of laser light during bleaching will not reduce the incidence or severity of sensitivity and will not increase the degree of color change compared with nonlaser light sources. SUMMARY:Objective: To evaluate whether the use of laser during in-office bleaching promotes a reduction in dental se...
journal_title:Operative dentistry
pub_type: 杂志文章,meta分析
doi:10.2341/19-064-L
更新日期:2020-11-01 00:00:00
abstract::The aim of this study was to determine whether using a silane-containing universal adhesive as a silane primer in glass-ceramic/resin cement systems affects biaxial flexural strength (BFS) and bonded interface integrity after loading. Glass-ceramic (IPS e.max CAD, Ivoclar/Vivadent, Schaan, Liechtenstein) disc-shaped s...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/17-356-L
更新日期:2019-03-01 00:00:00
abstract::This research investigated the effects of wet and dry conditions of phosphoric acid etched dentin on resin bonding and determined the optimum moisture condition for resin bonding using an ethanol-based one-bottle adhesive system. Bovine dentin surfaces were etched with 35% phosphoric acid and rinsed with water. Under ...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2002-11-01 00:00:00
abstract::In the direct treatment of cervical lesions and to improve the impression-making procedure prior to fabricating indirect restorations, exposure of the gingival sulcus and control of hemorrhage or gingival fluid seepage are a prerequisite. For gingival displacement, cords impregnated with medicaments are widely used. I...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2002-07-01 00:00:00
abstract::The critical point of the clinical procedure of direct splinting is the placement of the fiber-reinforced strip, which has to be well adapted to tooth surfaces. This article describes the use of aluminum foil to cover and protect the fiber-reinforced strip from light polymerization during the direct splinting techniqu...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/05-68
更新日期:2006-05-01 00:00:00
abstract::This study examined the effect of different light activation modes for light-cured resin-based composites on the shear bond strength to dentin of two one-bottle adhesives with differing acidity. In this experimental study, a flat middle dentin surface was prepared on 110 extracted sound molars using a 600-grit polish ...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/08-048-L
更新日期:2009-09-01 00:00:00
abstract::This study investigated the leakage pathway of facial and lingual Class V cavities restored with different flowable resin composites bonded with one bonding agent by examining the resin/dentin interface. Forty Class V cavities were etched with 37% phosphoric acid gel; Single Bond dental adhesive was applied, then the ...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/07-22
更新日期:2008-01-01 00:00:00
abstract::Of the many factors under their control, clinicians can manipulate light-exposure duration but must deal with a set intensity of light emitted from the dental curing unit. This research investigates the interdependence of exposure duration and source intensity on resin cure at various depths within a simulated light-c...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1994-01-01 00:00:00
abstract::Recently, manufacturers introduced presterilized, single-use, plastic light-curing tips to be used either routinely or on patients with known or questionable communicable health concerns. The purpose of this study was to examine the effect of these single-use tips on light transmission compared to conventional fiber-o...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1998-07-01 00:00:00
abstract:OBJECTIVE::Computer aided design-computer aided machining (CAD-CAM) ceramic crowns are replacing ceramo-metal ones due to newly developed mechanical properties and esthetics. To obtain knowledge about their interactions due to polishing and occlusal contacts with the opposing dental enamel specimen, including surface r...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/17-153-L
更新日期:2019-01-01 00:00:00
abstract::Coronal fractures of posterior teeth are not rare in clinical practice. Most of the time they constitute a restorational problem for the clinician, since they usually end below the free gingival crest. Two hundred coronal fractures of posterior teeth were examined in this study, with respect to several factors. Some o...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1989-01-01 00:00:00
abstract:OBJECTIVES:This study aimed to assess the retention of metal copings luted to uremic teeth with five different luting agents. METHODS:A total of 35 sound natural molars was collected from uremic patients and randomly assigned into five groups (n=7). The teeth were prepared for metal copings using diamond tips and wate...
journal_title:Operative dentistry
pub_type: 杂志文章,随机对照试验
doi:10.2341/12-523-LR2
更新日期:2014-05-01 00:00:00
abstract:OBJECTIVES:This study evaluated the bond strength of luting systems for bonding glass fiber posts to root canal dentin. The hypothesis tested was that there are no differences in bond strength of glass fiber posts luted with different cement systems. METHODS:Forty bovine incisors were randomly assigned to five differe...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/11-035-L
更新日期:2012-01-01 00:00:00
abstract::One hundred non-carious, non-undercut cervical lesions were restored with Silux Plus or Estio LC and bonded with Fuji Bond LC. The restorations were evaluated yearly for retention and marginal discoloration. After five years, the overall retention rate was 96%. Of the 41 restorations examined at five years, five had c...
journal_title:Operative dentistry
pub_type: 临床试验,杂志文章
doi:
更新日期:2002-09-01 00:00:00
abstract::Provisional restorations of full crown preparations may permit more microleakage of bacteria and their products than the final castings do. However, most investigations of the sealing qualities of cemented castings have reported that they too permit dye leakage. One approach to the problem is to seal the dentin with d...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1992-01-01 00:00:00
abstract::The current study compared the marginal adaptation of Class II open-sandwich restorations with a RMGIC versus a dual-cure composite as dentin substitute. Class II cavities were prepared on 50 extracted human third molars. The teeth were randomly assigned to two groups of 25 teeth to compare one dual cure composite (Mu...
journal_title:Operative dentistry
pub_type: 杂志文章,随机对照试验
doi:10.2341/08-29
更新日期:2009-03-01 00:00:00
abstract:OBJECTIVE:This in vitro study evaluated the effect of polishing with different polishing systems on the surface roughness and gloss of commercial composites. METHODS:One hundred disk-shaped specimens (10 mm in diameter × 2 mm thick) were made with Filtek P-90, Filtek Z350 XT, Opallis, and Grandio. The specimens were m...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/14-014L
更新日期:2015-07-01 00:00:00
abstract:UNLABELLED:This study evaluated the microtensile bond strength (μ-TBS) of low-shrinkage composites with their corresponding adhesive systems, Filtek Silorane/Silorane adhesive (SIL, 3M ESPE AG, Seefeld, Germany) and Aelite LS/One-Step Plus (AL, BISCO Inc, Schaumburg, IL, USA) in cavities with different C-factors. Filte...
journal_title:Operative dentistry
pub_type: 杂志文章,随机对照试验
doi:10.2341/10-105-L
更新日期:2011-05-01 00:00:00