Fracture Toughness Analysis of Ceramic and Resin Composite CAD/CAM Material.

Abstract:

OBJECTIVES:To evaluate and compare the fracture toughness of dental CAD/CAM materials of different material classes intended for in-office milling (glass ceramics, hybrid, resin composites) and the influence of aging on this property. METHODS AND MATERIALS:The fracture toughness (critical intensity factor, KIc) values of 9 CAD/CAM restorative materials (Ambarino High-Class, Brilliant Crios, Cerasmart, exp. CAD/CAM composite, Katana Avencia, Lava Ultimate, VITA Enamic, IPS Empress CAD, and IPS e.max CAD) were determined using the SEVNB method in a four-point bending setup. Twenty bending bars of each material with a 4 × 3 cross and a minimum length of 12 mm were cut out of CAD/CAM milling blocks. Notching was done starting with a pre-cut and consecutive polishing and v-shaping with a razor blade, resulting in a final depth of v-shaped notches of between 0.8 and 1.2 mm. Half of the specimens were selected for initial fracture toughness measurements. The others were thermocycled in distilled water for 30,000× (5/55°C; 30-second dwell time) before testing. Specimen fracture surfaces were analyzed using confocal laser scanning microscopy. RESULTS:All specimens for each material fractured into two fragments and showed the typical compression curl and brittle failure markings. Comparing initial KIc values, lithium disilicate ceramic IPS e.max CAD showed significantly the highest and leucite-reinforced ceramic IPS Empress CAD significantly the lowest KIc values (p<0.001). All tested CAD/CAM materials with a resin component ranged in the same KIc value group (p>0.999-0.060). After thermal cycling, the highest KIc values were measured for lithium disilicate ceramic IPS e.max CAD, followed by resin composite materials Ambarino High-Class (p<0.001-0.006) and hybrid material VITA Enamic (p<0.001-0.016), while the significantly lowest values were reflected for the resin composite materials Cerasmart, LAVA Ultimate (p<0.001-0.006), and Katana Avencia (p<0.001-0.009). The roughness of the fracture surfaces varied depending on the microstructure of the respective material. The ceramic surfaces showed the smoothest surfaces. The fracture surface of VITA Enamic revealed microstructural inhomogeneities and microcracks. For CAD/CAM resin composite materials, crack paths through the matrix and interfaces of matrix and fillers could be observed at the microstructure level. CONCLUSIONS:The materials tested show differences in fracture toughness typical for the class they belong to. With one exception (Ambarino High-Class), thermocycling affected the fracture toughness of materials with a resin component negatively, whereas the leucite and lithium disilicate ceramic showed stability.

journal_name

Oper Dent

journal_title

Operative dentistry

authors

Hampe R,Theelke B,Lümkemann N,Eichberger M,Stawarczyk B

doi

10.2341/18-161-L

subject

Has Abstract

pub_date

2019-07-01 00:00:00

pages

E190-E201

issue

4

eissn

0361-7734

issn

1559-2863

journal_volume

44

pub_type

杂志文章
  • The effect of flowable materials on the microleakage of Class II composite restorations that extend apical to the cemento-enamel junction.

    abstract::This in vitro study investigated the effects of a thin layer of flowable composite or compomer on microleakage occurring in Class II packable and nanofilled composite restorations that extend apical to the cemento-enamel junction (CEJ). The current study also investigated any differences in microleakage that occur bet...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/08-91

    authors: Sadeghi M,Lynch CD

    更新日期:2009-05-01 00:00:00

  • Barcoll hardness of different resin-based composites cured by halogen or light emitting diode (LED).

    abstract::The clinical performance of light curing resin composites is greatly influenced by the quality of the light-curing unit (LCU). Halogen LCUs are commonly used for curing composite materials. However, they have some drawbacks. The development of new, blue, super bright light emitting diodes (LED LCU) of 470-nm wavelengt...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Bala O,Uçtasli MB,Tüz MA

    更新日期:2005-01-01 00:00:00

  • Factors affecting adhesion to mineralized tissues.

    abstract::The objective of this paper is to review the literature concerning factors affecting adhesion to mineralized tissues. Factors related to the physicochemical structure of the adherents and to the inherent properties of composite restorative materials, along with the postulated bonding mechanisms of current adhesive sys...

    journal_title:Operative dentistry

    pub_type: 杂志文章,评审

    doi:

    authors: Van Meerbeek B,Lambrechts P,Inokoshi S,Braem M,Vanherle G

    更新日期:1992-01-01 00:00:00

  • Effect of cyclic loading on the bond strength of class II restorations with different composite materials.

    abstract::This study evaluated the effect of cyclic loading on the bond strength of Class II restorations using different composite materials. Class II preparations with gingival margins located in dentin were performed on the mesial surface of 80 bovine incisors. The teeth were randomly allocated to eight groups (n=10) accordi...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/07-65

    authors: Cavalcanti AN,Mitsui FH,Silva F,Peris AR,Bedran-Russo A,Marchi GM

    更新日期:2008-03-01 00:00:00

  • Class II composite restorations: importance of cervical enamel in vitro.

    abstract:OBJECTIVE:This study evaluated the importance of enamel at the cervical margin for support and retention of a class II composite restoration in relation to fracture strength, fracture mode, and leakage. METHODS:Sixty-five newly extracted teeth were randomly divided into five groups. Within each group, standardized cla...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/10-126-L

    authors: Laegreid T,Gjerdet NR,Vult von Steyern P,Johansson AK

    更新日期:2011-03-01 00:00:00

  • Cuspal Deflection in Premolar Teeth Restored with Bulk-Fill Resin-Based Composite Materials.

    abstract::The present study investigated the effect of three high-viscosity bulk-fill resin-based composite materials on cuspal deflection in natural teeth. Thirty-two sound maxillary premolar teeth with large slot mesio-occlusal-distal cavities were distributed into four groups (n=8). Three groups were restored with bulk-fill ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/16-072-L

    authors: Elsharkasi MM,Platt JA,Cook NB,Yassen GH,Matis BA

    更新日期:2018-01-01 00:00:00

  • Rigidity and retention of ceramic root canal posts.

    abstract::Ceramic root-canal posts offer potential advantages over other types with respect to aesthetics and biocompatibility. Any post must be sufficiently rigid and retentive to withstand functional forces. Ceraposts (1.2 mm coronal diameter, ceramic, tapering, smooth posts) and Paraposts (1.25 mm, stainless-steel, parallel,...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Purton DG,Love RM,Chandler NP

    更新日期:2000-05-01 00:00:00

  • Ceramic Veneers for Esthetic Restoration of Retained Primary Teeth: A 4-year Follow-up Case Report.

    abstract::Retained primary teeth in the smile zone can cause patient dissatisfaction, especially if associated with malposition of teeth. Orthodontic and prosthetic treatment options to treat the situation may not be accepted by some patients. Therefore, these patients tend to maintain their primary teeth and seek different est...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/15-363-S

    authors: Bin-Shuwaish MS

    更新日期:2017-03-01 00:00:00

  • Clinical evaluation of DIAGNOdent in detection of occlusal caries in newly erupted noncavitated first permanent molars in caries-active children.

    abstract:OBJECTIVE:The aim of this study was to compare the in vivo diagnostic ability of a laser fluorescence system (DIAGNOdent, KaVo, Biberac, Germany) with that of visual inspection in the early detection of occlusal caries in newly erupted noncavitated first permanent molars among caries-active children. MATERIALS AND MET...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/10-309-C

    authors: Duruturk L,Ciftçi A,Baharoğlu S,Oztuna D

    更新日期:2011-07-01 00:00:00

  • Effect of power density on shrinkage of dental resin materials.

    abstract::This study compares volumetric changes and rates of shrinkage during different stages of polymerization of dental resin composites and compomers exposed to the same total energy by using two different combinations of power density and exposure duration. A hybrid composite and its equivalent flowable and a compomer and...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Oberholzer TG,Pameijer CH,Grobler SR,Rossouw RJ

    更新日期:2003-09-01 00:00:00

  • The effect of various surface coatings on fluoride release from glass-ionomer cement.

    abstract::To protect glass-ionomer cement from moisture contamination and dehydration during initial setting, immediate application of a surface coating agent is recommended. This study compared the effect of various surface coatings on F release from glass-ionomer cement. Twenty glass-ionomer cement (Ketac Fil Aplicap) disks (...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Castro GW,Gray SE,Buikema DJ,Reagan SE

    更新日期:1994-09-01 00:00:00

  • Effect of light activation mode on the incompatibility between one-bottle adhesives and light-cured composites: an in vitro shear bond strength study.

    abstract::This study examined the effect of different light activation modes for light-cured resin-based composites on the shear bond strength to dentin of two one-bottle adhesives with differing acidity. In this experimental study, a flat middle dentin surface was prepared on 110 extracted sound molars using a 600-grit polish ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/08-048-L

    authors: Shafiei F,Saffarpour A,Moradmand M,Alavi AA

    更新日期:2009-09-01 00:00:00

  • Influence of Tooth Pigmentation on H2O2 Diffusion and Its Cytotoxicity After In-office Tooth Bleaching.

    abstract:CLINICAL RELEVANCE:Pigments in tooth structures affect the diffusion of H2O2 through enamel and dentin. The bleaching methodology can be impacted. SUMMARY:Objective: The aim of this study was to evaluate the influence of the presence of pigments in tooth structures on the trans-enamel and trans-dentin diffusion of hyd...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/19-013-L

    authors: de Oliveira Duque CC,Soares DG,Briso A,Ortecho-Zuta U,de Oliveira Ribeiro RA,Hebling J,de Souza Costa CA

    更新日期:2020-11-01 00:00:00

  • Cracked tooth syndrome in an unrestored maxillary premolar: a case report.

    abstract::Cracked tooth syndrome is known to occur most frequently in heavily restored teeth. Nevertheless, when the symptoms occur in intact teeth, there is difficulty in obtaining a correct diagnosis because it is difficult for the dentist to find where the crack is located. This clinical report describes the diagnostic proce...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/13-257

    authors: Batalha-Silva S,Gondo R,Stolf SC,Baratieri LN

    更新日期:2014-09-01 00:00:00

  • Composite cure and shrinkage associated with high intensity curing light.

    abstract::This study investigated the effectiveness of cure and post-gel shrinkage of three visible light-cured composite resins (In Ten-S [IT], Ivoclar Vivadent; Z100 [ZO], 3M-ESPE; Tetric Ceram [TC], Ivoclar Vivadent) when polymerized with a very high intensity (1296 +/- 2 mW/cm2) halogen light (Astralis 10, Ivoclar Vivadent)...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Yap AU,Wong NY,Siow KS

    更新日期:2003-07-01 00:00:00

  • Bulk-fill resin composites: polymerization contraction, depth of cure, and gap formation.

    abstract::The bulk-filling of deep, wide dental cavities is faster and easier than traditional incremental restoration. However, the extent of cure at the bottom of the restoration should be carefully examined in combination with the polymerization contraction and gap formation that occur during the restorative procedure. The a...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/13-324-L

    authors: Benetti AR,Havndrup-Pedersen C,Honoré D,Pedersen MK,Pallesen U

    更新日期:2015-03-01 00:00:00

  • Efficacy of a Light-cured Tetracaine-based Anesthetic Gel for Rubber Dam Clamp Placement: A Triple-blind Randomized Clinical Trial.

    abstract:OBJECTIVES:To evaluate the efficacy of a new light-cured anesthetic gel for pain control in adults undergoing rubber dam isolation for the restorative treatment of noncarious cervical lesions (NCCLs). METHODS AND MATERIALS:This study was a randomized, split-mouth, triple-blind, controlled trial. The sample comprised 5...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/18-130-C

    authors: Wambier LM,Gonzaga CC,Chibinski A,Wambier DS,Farago PV,Loguercio AD,Reis A

    更新日期:2020-03-01 00:00:00

  • Microtensile Bond Strength of Resin-Modified Glass Ionomer Cement to Sound and Artificial Caries-Affected Root Dentin With Different Conditioning.

    abstract::In this laboratory study, the microtensile bond strengths (μTBS) of resin-modified glass ionomer cement (RM-GIC) to sound and artificial caries-affected bovine root dentin (ACAD) using three different conditioning agents were evaluated after 24 hours and three months. The fractured interface was examined with a scanni...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/16-375-L

    authors: Saad A,Inoue G,Nikaido T,Ikeda M,Burrow MF,Tagami J

    更新日期:2017-11-01 00:00:00

  • Effect of Thermocycling, Degree of Conversion, and Cavity Configuration on the Bonding Effectiveness of All-in-One Adhesives.

    abstract::The aim of this study was to compare five all-in-one bonding agents with respect to microleakage, microtensile bond strength (μTBS), degree of conversion (DC) and the impact of cavity configuration. The materials tested were Adper Easy Bond, Clearfil S3 Bond, iBond, Optibond All-in-One, Xeno IV, and Adper Single Bond ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/14-185-LR1

    authors: El-Damanhoury HM,Gaintantzopoulou M

    更新日期:2015-09-01 00:00:00

  • Failure risk of posterior composites with post-operative sensitivity.

    abstract::Post-operative sensitivity (POS) may be observed in recently placed posterior composites. Evidence-based guidelines for the management of posterior composites with POS have yet to be determined. This study examined a retrospective analysis of the findings of a unique multi-center clinical trial to investigate the five...

    journal_title:Operative dentistry

    pub_type: 临床试验,杂志文章,多中心研究

    doi:

    authors: Hayashi M,Wilson NH

    更新日期:2003-11-01 00:00:00

  • Curing of pit & fissure sealants using Light Emitting Diode curing units.

    abstract::Light Emitting Diode (LED) curing units are attractive to clinicians, because most are cordless and should create less heat within tooth structure. However, questions about polymerization efficacy have surrounded this technology. This research evaluated the adequacy of the depth of cure of pit & fissure sealants provi...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Platt JA,Clark H,Moore BK

    更新日期:2005-11-01 00:00:00

  • In Vitro Biocompatibility of Contemporary Bulk-fill Composites.

    abstract::This study evaluated the biocompatibility of contemporary bulk-fill resin-based composites (RBCs) including PRG (pre-reacted glass ionomer) materials based on the International Organization for Standardization 10993. In addition, the effect of composite thickness on cytotoxicity was also assessed. Two standard composi...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/15-059-L

    authors: Toh WS,Yap AU,Lim SY

    更新日期:2015-11-01 00:00:00

  • Enamel Surface Changes After Exposure to Bleaching Gels Containing Carbamide Peroxide or Hydrogen Peroxide.

    abstract:OBJECTIVE:This study evaluated the differences in enamel color change, surface hardness, elastic modulus, and surface roughness between treatments with four bleaching gels containing carbamide peroxide (two at 10% and one each at 35%, and 45%) and two bleaching gels containing hydrogen peroxide (two at 40%). METHODS:E...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/15-010-L

    authors: Cvikl B,Lussi A,Moritz A,Flury S

    更新日期:2016-01-01 00:00:00

  • The microtensile bond strength of Fuji IX glass ionomer cement to antibacterial conditioned dentin.

    abstract:INTRODUCTION:Adding antibacterial agents to a dentin conditioner used for a glass ionomer cement (GIC) has been shown to be antibacterial; however, it is not known whether this antimicrobial conditioning agent affects the bond strength to dentin in situ. This study applied GIC to antibacterial conditioned dentin withou...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Botelho MG

    更新日期:2005-05-01 00:00:00

  • Effects of pre-soaked retraction cords on the microcirculation of the human gingival margin.

    abstract::In the direct treatment of cervical lesions and to improve the impression-making procedure prior to fabricating indirect restorations, exposure of the gingival sulcus and control of hemorrhage or gingival fluid seepage are a prerequisite. For gingival displacement, cords impregnated with medicaments are widely used. I...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Fazekas A,Csempesz F,Csabai Z,Vág J

    更新日期:2002-07-01 00:00:00

  • Restoration of occlusal vertical dimension in dental erosion caused by gastroesophageal reflux: case report.

    abstract::The authors describe a minimally invasive procedure for occlusal rehabilitation in a young patient presenting with mild mandibular prognathism and loss of occlusal vertical dimension caused by dental erosion from chronic gastroesophageal reflux. ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/09-110T

    authors: Reston EG,Closs LQ,Busato AL,Broliato GA,Tessarollo FR

    更新日期:2010-01-01 00:00:00

  • Microleakage resistance of minimally invasive Class I flowable composite restorations.

    abstract::Minimally invasive flowable composite Class I restorations are widely used. However, flowable composites are characterized by low filler contents, modified resin formulations, low moduli of elasticity, low viscosity, generally poor mechanical properties, and decreased long-term stability. The purpose of this study was...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/11-106-L

    authors: Bonilla ED,Stevenson RG,Caputo AA,White SN

    更新日期:2012-05-01 00:00:00

  • Factors affecting light transmission of single-use, plastic light-curing tips.

    abstract::Recently, manufacturers introduced presterilized, single-use, plastic light-curing tips to be used either routinely or on patients with known or questionable communicable health concerns. The purpose of this study was to examine the effect of these single-use tips on light transmission compared to conventional fiber-o...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Rueggeberg FA,Caughman WF

    更新日期:1998-07-01 00:00:00

  • Interfacial Evaluation of CAD/CAM Resin Inlays on the Cavity Floor Using Swept-source Optical Coherence Tomography.

    abstract:CLINICAL RELEVANCE:When a resin nanoceramic inlay is cemented using self-adhesive cement, a universal dentin adhesive can be applied to the prepared cavity. The application of the adhesive before self-adhesive cement placement provides similar or better interfacial adaptation than without the adhesive. SUMMARY:Purpose...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/19-141-L

    authors: Han SH,Shimada Y,Sadr A,Tagami J,Yang SE

    更新日期:2020-11-01 00:00:00

  • Microleakage of compomer restorations in primary teeth after preparation with bur or air abrasion.

    abstract::This study compared the degree of marginal leakage of a compomer in Class V cavities of human primary molars prepared by a conventional dental bur and air abrasion with or without acid etching. Fifty-six non-carious extracted primary molars were randomly divided into four groups (n=14) to be prepared by four technique...

    journal_title:Operative dentistry

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:

    authors: Aysegül O,Nurhan O,Haluk B,Dilek T

    更新日期:2005-03-01 00:00:00