Clinical evaluation of DIAGNOdent in detection of occlusal caries in newly erupted noncavitated first permanent molars in caries-active children.

Abstract:

OBJECTIVE:The aim of this study was to compare the in vivo diagnostic ability of a laser fluorescence system (DIAGNOdent, KaVo, Biberac, Germany) with that of visual inspection in the early detection of occlusal caries in newly erupted noncavitated first permanent molars among caries-active children. MATERIALS AND METHODS:A total of 505 mandibular first permanent molar teeth in 307 children aged 6 to 7 years with decayed, missing, and filled tooth surfaces (DMFS)>8 were examined. Visual examination and DIAGNOdent measurement of caries were compared for teeth with intact occlusal surfaces or varying degrees of fissure discoloration, but with no radiologic evidence of enamel or dentin caries. Teeth were classified according to caries status as sound, enamel caries, or dentin caries using visual examination and DIAGNOdent scoring systems corresponding to histologic definitions of caries depth. Analysis of the results was performed using Cohen's unweighted kappa statistic. RESULTS:Statistical analysis revealed "poor" agreement between the two diagnostic methods (κ=0.231). CONCLUSION:Clinical results suggest that the DIAGNOdent device does not seem to be suitable for accurate diagnosis of early caries lesions in newly erupted first permanent molars.

journal_name

Oper Dent

journal_title

Operative dentistry

authors

Duruturk L,Ciftçi A,Baharoğlu S,Oztuna D

doi

10.2341/10-309-C

subject

Has Abstract

pub_date

2011-07-01 00:00:00

pages

348-55

issue

4

eissn

0361-7734

issn

1559-2863

journal_volume

36

pub_type

杂志文章
  • Efficacy testing of visible-light-curing units.

    abstract::This study evaluated (1) the effect of known reductions in the output of curing lights on the depth of cure of various resins as determined by hardness measurements, and (2) the ability of the clinician to detect reduced light output by use of an explorer to compare the hardness of the top and bottom surfaces of resin...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Fowler CS,Swartz ML,Moore BK

    更新日期:1994-03-01 00:00:00

  • Sudden Onset of Subcutaneous Air Emphysema After the Application of Air to a Maxillary Premolar Located in a Nonsurgical Field.

    abstract::Although rare, subcutaneous air emphysema can occur during dental procedures such as endodontic treatment, surgical extractions, and preparing a tooth for an indirect or direct dental restoration. We report the development of a subcutaneous air emphysema that was introduced through the periodontal ligament of an untre...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/15-155-S

    authors: Van Tubergen EA,Tindle D,Fox GM

    更新日期:2017-09-01 00:00:00

  • Effect of Surface Sealants and Polishing Time on Composite Surface Roughness and Microhardness.

    abstract::The objective of this study was to evaluate the effect of surface sealants and polishing delay time on a nanohybrid resin composite roughness and microhardness. Eighty disc specimens were made with a nanohybrid resin (Esthet-X HD, Dentsply). The specimens were divided into two groups (n=40) according to polishing time...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/17-048-L

    authors: Ruschel VC,Bona VS,Baratieri LN,Maia HP

    更新日期:2018-07-01 00:00:00

  • The effect of ceramic restoration shade and thickness on the polymerization of light- and dual-cure resin cements.

    abstract:OBJECTIVES:Inadequately polymerized resin cements may negatively affect the clinical performance of cemented all-ceramic restorations. The purpose of this in vitro study was to evaluate the effect of ceramic thickness and shade on the microhardness of various light-cured (LC) and dual-cured (DC) resin cements. The amou...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/10-206-L

    authors: Kilinc E,Antonson SA,Hardigan PC,Kesercioglu A

    更新日期:2011-11-01 00:00:00

  • Factors associated with microleakage in Class II resin composite restorations.

    abstract::This in vitro study investigated the correlation between factors related to cavosurface marginal adaptation and microleakage in Class II cavities restored with a light- or chemical-activated resin composite. Standardized cavities were prepared in 40 molars that were randomly divided between both materials. Each of the...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/06-16

    authors: Idriss S,Abduljabbar T,Habib C,Omar R

    更新日期:2007-01-01 00:00:00

  • Comparison of two methods of measuring dye penetration in restoration microleakage studies.

    abstract::This study compared the slice method of measuring microleakage to the whole-wall method. Forty-eight Class V direct metal restorations were placed in the buccal and lingual surfaces of 24 human molars. Following thermocycling and storage in 2% methylene blue stain for 12 hours, the teeth were sectioned and the restora...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Williams PT,Schramke D,Stockton L

    更新日期:2002-11-01 00:00:00

  • The effect of additional enamel etching and a flowable composite to the interfacial integrity of Class II adhesive composite restorations.

    abstract::This in vitro study evaluated the interfacial integrity of Class II resin composite restorations. The influence of a flowable composite and additional enamel etching was also evaluated. Deep, saucer-shaped Class II cavities were prepared in the mesial and distal proximal surfaces of 25 extracted human molars and assig...

    journal_title:Operative dentistry

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:

    authors: Belli S,Inokoshi S,Ozer F,Pereira PN,Ogata M,Tagami J

    更新日期:2001-01-01 00:00:00

  • Criteria for the Replacement of Restorations: Academy of Operative Dentistry European Section.

    abstract::The replacement of a restoration is one of the most common procedures in dentistry. However, the criteria for such intervention, excluding catastrophic failure and persistent discomfort and pain, continue to be the subject of considerable debate. The decision-making process remains subjective on the part of the treati...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/15-058-O

    authors: Wilson N,Lynch CD,Brunton PA,Hickel R,Meyer-Lueckel H,Gurgan S,Pallesen U,Shearer AC,Tarle Z,Cotti E,Vanherle G,Opdam N

    更新日期:2016-09-01 00:00:00

  • The microtensile bond strength of Fuji IX glass ionomer cement to antibacterial conditioned dentin.

    abstract:INTRODUCTION:Adding antibacterial agents to a dentin conditioner used for a glass ionomer cement (GIC) has been shown to be antibacterial; however, it is not known whether this antimicrobial conditioning agent affects the bond strength to dentin in situ. This study applied GIC to antibacterial conditioned dentin withou...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Botelho MG

    更新日期:2005-05-01 00:00:00

  • Effect of power density on shrinkage of dental resin materials.

    abstract::This study compares volumetric changes and rates of shrinkage during different stages of polymerization of dental resin composites and compomers exposed to the same total energy by using two different combinations of power density and exposure duration. A hybrid composite and its equivalent flowable and a compomer and...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Oberholzer TG,Pameijer CH,Grobler SR,Rossouw RJ

    更新日期:2003-09-01 00:00:00

  • Factors affecting light transmission of single-use, plastic light-curing tips.

    abstract::Recently, manufacturers introduced presterilized, single-use, plastic light-curing tips to be used either routinely or on patients with known or questionable communicable health concerns. The purpose of this study was to examine the effect of these single-use tips on light transmission compared to conventional fiber-o...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Rueggeberg FA,Caughman WF

    更新日期:1998-07-01 00:00:00

  • Water Sorption and Solubility of Luting Agents Used Under Ceramic Laminates With Different Degrees of Translucency.

    abstract:PURPOSE:The aim of this study was to evaluate the effect of low-thickness ceramic laminate translucency on water sorption and solubility in resin luting agents. METHODS AND MATERIALS:Ceramic slides (15×0.7 mm) were generated using lithium disilicate (IPS e.max Press, Ivoclar-Vivadent, Schaan, Liechtenstein) that were ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/15-201-L

    authors: Leal CL,Queiroz A,Foxton RM,Argolo S,Mathias P,Cavalcanti AN

    更新日期:2016-09-01 00:00:00

  • A clinical study on interdental separation techniques.

    abstract::The effect of interdental separation of a special separation ring and wooden wedge was investigated. In a split-mouth design, 27 patients were randomly assigned to one of two groups (W or S). In 11 patients, an interdental wooden wedge (Hawe-Neos) was placed (group W), and in 16 patients, a separation ring (Composi-Ti...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/06-73

    authors: Loomans BA,Opdam NJ,Bronkhorst EM,Roeters FJ,Dörfer CE

    更新日期:2007-05-01 00:00:00

  • Influence of Thermal Cycling on Flexural Properties and Simulated Wear of Computer-aided Design/Computer-aided Manufacturing Resin Composites.

    abstract:OBJECTIVE:The purpose of this study was to evaluate the influence of thermal cycling on the flexural properties and simulated wear of computer-aided design/computer-aided manufacturing (CAD/CAM) resin composites. METHODS:The six CAD/CAM resin composites used in this study were 1) Lava Ultimate CAD/CAM Restorative (LU)...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/16-046-L

    authors: Tsujimoto A,Barkmeier WW,Takamizawa T,Latta MA,Miyazaki M

    更新日期:2017-01-01 00:00:00

  • Fit of veneers made by CAD-CAM and platinum foil methods.

    abstract::Veneers were fabricated by CEREC CAD-CAM and the platinum foil techniques for standardized preparations on 10 artificial teeth. Mesial preparation contacts were broken, but distal contacts remained intact. The veneers were cemented in a standardized manner to their teeth. The veneers and their attached cement were emb...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Suh PS,Johnson R,White SN

    更新日期:1997-05-01 00:00:00

  • In vitro bonding performance of self-etch adhesives: II--ultramorphological evaluation.

    abstract:OBJECTIVE:To study the interfacial ultra-morphology formed by "all-in-one" self-etch adhesives. METHODS:Forty-nine extracted molars were assigned to one of five all-in-one adhesives: Adper Prompt L-Pop (AP, 3M ESPE); Clearfil S3 Bond (S3, Kuraray); G-Bond (GB, GC America); iBond (iB, Heraeus Kulzer) and Xeno IV (XE, D...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/07-133

    authors: Perdigão J,Lopes MM,Gomes G

    更新日期:2008-09-01 00:00:00

  • Randomized Clinical Trial to Evaluate MTA Indirect Pulp Capping in Deep Caries Lesions After 24-Months.

    abstract:OBJECTIVE:This clinical study aimed to assess the efficacies of mineral trioxide aggregate (MTA) and calcium hydroxide [Ca(OH)2] in the treatment of deep carious lesions by the direct complete caries removal technique. METHODS AND MATERIALS:A total of 100 permanent molar/premolar teeth were capped with either Ca(OH)2 ...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/16-110-C

    authors: Koc Vural U,Kiremitci A,Gokalp S

    更新日期:2017-09-01 00:00:00

  • Two-year clinical performance of a polyacid-modified resin composite and a resin-modified glass-ionomer restorative material.

    abstract::This study compared the clinical performance of a polyacid-modified resin composite and a resin-modified glass-ionomer restorative material over two years. Thirty-four pairs of restorations of Compoglass and Fuji II LC were placed in caries-free cervical erosion/abfraction lesions without tooth preparation. Restoratio...

    journal_title:Operative dentistry

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:

    authors: Brackett WW,Browning WD,Ross JA,Brackett MG

    更新日期:2001-01-01 00:00:00

  • Prospective Clinical Study of Zirconia Full-coverage Restorations on Teeth Prepared With Biologically Oriented Preparation Technique on Gingival Health: Results After Two-year Follow-up.

    abstract:OBJECTIVES:To evaluate the clinical behavior of one-piece complete-coverage crowns and fixed partial dentures (FPDs) on teeth with vertical preparation without finish line biologically oriented preparation technique (BOPT). METHODS AND MATERIALS:This prospective study included 52 patients requiring treatment with rest...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/17-124-C

    authors: Agustín-Panadero R,Serra-Pastor B,Fons-Font A,Solá-Ruíz MF

    更新日期:2018-09-01 00:00:00

  • Effect of gender, experience, and value on color perception.

    abstract:STATEMENT OF THE PROBLEM:Precise shade matching can be one of the most difficult tasks for the dentist and some variables may influence the process of shade comparison. PURPOSE OF THE STUDY:This study tested the differences in shade perception between genders, the influence of the observer's clinical experience, and t...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/10-057-C

    authors: Milagres V,Teixeira ML,Miranda ME,Osorio Silva CH,Ribeiro Pinto JR

    更新日期:2012-05-01 00:00:00

  • Efficacy of a Light-cured Tetracaine-based Anesthetic Gel for Rubber Dam Clamp Placement: A Triple-blind Randomized Clinical Trial.

    abstract:OBJECTIVES:To evaluate the efficacy of a new light-cured anesthetic gel for pain control in adults undergoing rubber dam isolation for the restorative treatment of noncarious cervical lesions (NCCLs). METHODS AND MATERIALS:This study was a randomized, split-mouth, triple-blind, controlled trial. The sample comprised 5...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/18-130-C

    authors: Wambier LM,Gonzaga CC,Chibinski A,Wambier DS,Farago PV,Loguercio AD,Reis A

    更新日期:2020-03-01 00:00:00

  • Effect of light activation mode on the incompatibility between one-bottle adhesives and light-cured composites: an in vitro shear bond strength study.

    abstract::This study examined the effect of different light activation modes for light-cured resin-based composites on the shear bond strength to dentin of two one-bottle adhesives with differing acidity. In this experimental study, a flat middle dentin surface was prepared on 110 extracted sound molars using a 600-grit polish ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/08-048-L

    authors: Shafiei F,Saffarpour A,Moradmand M,Alavi AA

    更新日期:2009-09-01 00:00:00

  • Clinical evaluation of a resin-modified glass ionomer adhesive system: results at five years.

    abstract::One hundred non-carious, non-undercut cervical lesions were restored with Silux Plus or Estio LC and bonded with Fuji Bond LC. The restorations were evaluated yearly for retention and marginal discoloration. After five years, the overall retention rate was 96%. Of the 41 restorations examined at five years, five had c...

    journal_title:Operative dentistry

    pub_type: 临床试验,杂志文章

    doi:

    authors: Tyas MJ,Burrow MF

    更新日期:2002-09-01 00:00:00

  • Effect of mechanical properties of resin composites on the efficacy of the dentin bonding system.

    abstract::This study determined the relationship between marginal adaptation to dentin cavity preparations, tensile bond strength of the restorations, and mechanical properties of the composites. Contraction gaps, tensile bond strengths, flexural strengths, and Young's modulus of eight commercial resin composites were determine...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Hasegawa T,Itoh K,Koike T,Yukitani W,Hisamitsu H,Wakumoto S,Fujishima A

    更新日期:1999-11-01 00:00:00

  • Class II composite restorations: importance of cervical enamel in vitro.

    abstract:OBJECTIVE:This study evaluated the importance of enamel at the cervical margin for support and retention of a class II composite restoration in relation to fracture strength, fracture mode, and leakage. METHODS:Sixty-five newly extracted teeth were randomly divided into five groups. Within each group, standardized cla...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/10-126-L

    authors: Laegreid T,Gjerdet NR,Vult von Steyern P,Johansson AK

    更新日期:2011-03-01 00:00:00

  • Effect of resin cement system and root region on the push-out bond strength of a translucent fiber post.

    abstract:OBJECTIVES:This study evaluated the bond strength of luting systems for bonding glass fiber posts to root canal dentin. The hypothesis tested was that there are no differences in bond strength of glass fiber posts luted with different cement systems. METHODS:Forty bovine incisors were randomly assigned to five differe...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/11-035-L

    authors: Calixto LR,Bandéca MC,Clavijo V,Andrade MF,Vaz LG,Campos EA

    更新日期:2012-01-01 00:00:00

  • Effect of LED curing modes on cusp deflection and hardness of composite restorations.

    abstract::This in vitro study measured cusp deflection associated with MOD resin composite restorations in maxillary premolars with different curing light modes. Soft-start polymerization may reduce cusp deflection by reducing polymerization shrinkage stress. Forty maxillary premolars were mounted in stone and slot MOD cavities...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:

    authors: Alomari QD,Mansour YF

    更新日期:2005-11-01 00:00:00

  • The Effect of Resin-modified Glass-ionomer Cement Base and Bulk-fill Resin Composite on Cuspal Deformation.

    abstract:OBJECTIVES:This study investigated cuspal deformation in teeth restored with different types of adhesive materials with and without a base. METHODS:Mesio-occluso-distal slot cavities of moderately large dimension were prepared on extracted maxillary premolars (n=24). Teeth were assigned to one of four groups and resto...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/14-331-L

    authors: Nguyen KV,Wong RH,Palamara J,Burrow MF

    更新日期:2016-03-01 00:00:00

  • In Vitro Biocompatibility of Contemporary Bulk-fill Composites.

    abstract::This study evaluated the biocompatibility of contemporary bulk-fill resin-based composites (RBCs) including PRG (pre-reacted glass ionomer) materials based on the International Organization for Standardization 10993. In addition, the effect of composite thickness on cytotoxicity was also assessed. Two standard composi...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/15-059-L

    authors: Toh WS,Yap AU,Lim SY

    更新日期:2015-11-01 00:00:00

  • Effect of Sonic Resin Composite Delivery on Void Formation Assessed by Micro-computed Tomography.

    abstract:OBJECTIVES:The aim of this study was to quantify the internal void volume formation in commercially available, resin composites inserted using conventional or sonic insertion methods, and analyzed using three-dimensional (3D) micro-computed tomography (μCT). METHODS AND MATERIALS:Four resin composites were evaluated: ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/16-331-L

    authors: Hirata R,Pacheco RR,Caceres E,Janal MN,Romero MF,Giannini M,Coelho PG,Rueggeberg FA

    更新日期:2018-03-01 00:00:00