Abstract:
:This in-vitro study compared the resistance of extensive amalgam restorations retained by either four Regular TMS Link Plus pins, four amalgapins, Amalgambond Plus, Amalgambond Plus with HPA, Scotchbond Multi-Purpose Plus, PQ Amalgam, Panavia F 2.0, All-Bond 2 or Resinomer. Ninety caries-free third molars were embedded in acrylic resin and their occlusal surfaces reduced to within 2 mm of their CEJ. Tytin amalgam alloy was hand-condensed into copper band matrices reinforced with modeling compound after placement of mechanical retention or application of the amalgam bonding agents. Modeling compound and copper bands were removed after 24 hours, and the restorations were adjusted to produce specimens 5 mm in height with a 1 mm bevel on the occlusal-axial surface. The specimens were stored in 100% humidity for one month followed by immersion in de-ionized water for 24 hours at 37 degrees C. The specimens were loaded in compression at a 45 degrees angle in an Instron Universal Testing Machine at a crosshead speed of 0.02 inches/minute. The mean failure loads and standard deviations recorded in Newtons were as follows: Amalgambond Plus with HPA 2160N (380), Scotchbond Multi-Purpose Plus 1900N (380), four Amalgapins 1770N (340), PQAmalgam 1660N (270), Panavia F 2.0 1620N (440), Amalgambond Plus 1570N (390), four Regular TMS Link Plus Pins 1325N (406), All-Bond 2 1300N (390) and Resinomer 1245N (310). A one-way ANOVA and Tukey post hoc analysis indicated all amalgam bonding agents were statistically equal to either four Regular TMS Link Plus pins orfour amalgapins.
journal_name
Oper Dentjournal_title
Operative dentistryauthors
Imbery TA,Coudron J,Moon PCdoi
10.2341/08-5subject
Has Abstractpub_date
2008-11-01 00:00:00pages
666-74issue
6eissn
0361-7734issn
1559-2863journal_volume
33pub_type
杂志文章abstract::This study evaluated the microleakage of resin-modified glass ionomer, flowable compomer and flowable resin composite restorations on a Class V cavity of simulated advanced root caries under a flexural load cycling condition. Thirty-six non-carious human maxillary premolars were mounted in cylindrical acrylic resin mo...
journal_title:Operative dentistry
pub_type: 临床试验,杂志文章,随机对照试验
doi:
更新日期:2005-03-01 00:00:00
abstract:OBJECTIVES:To evaluate the bond strength of adhesive luting agents applied to caries-affected dentin (CAD). METHODS:Thirty-six noncarious human third molars were abraded to expose an occlusal dentin surface. Caries lesions were induced in half of the samples using a microcosm biofilm model. Biofilm was cultivated unde...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/14-169-L
更新日期:2015-05-01 00:00:00
abstract::This study evaluated the two-year clinical performance of two minimally invasive cavity preparation techniques, bur and laser, in Class I occlusal resin composite restorations. Twenty-seven patients, each having at least one pair of occlusal caries, were enrolled in this study. For each patient, one of the cavities wa...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/09-339-C
更新日期:2010-09-01 00:00:00
abstract:PURPOSE:This study evaluated the effect of thermocycling on the microtensile bond strength of four adhesive luting agents to GN-I CAD-CAM ceramic. The hypothesis tested was that thermocycling did not affect bonding effectiveness, irrespective of the luting agents used. MATERIALS AND METHODS:Ceramic specimens of two di...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/06-106
更新日期:2007-07-01 00:00:00
abstract:OBJECTIVE:The aim of this study was to compare the in vivo diagnostic ability of a laser fluorescence system (DIAGNOdent, KaVo, Biberac, Germany) with that of visual inspection in the early detection of occlusal caries in newly erupted noncavitated first permanent molars among caries-active children. MATERIALS AND MET...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/10-309-C
更新日期:2011-07-01 00:00:00
abstract::Veneers were fabricated by CEREC CAD-CAM and the platinum foil techniques for standardized preparations on 10 artificial teeth. Mesial preparation contacts were broken, but distal contacts remained intact. The veneers were cemented in a standardized manner to their teeth. The veneers and their attached cement were emb...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1997-05-01 00:00:00
abstract::This study compared microleakage of composite bonded to etched flattened enamel in seven groups of five extracted maxillary molars. The facial enamel of the molars was ground flat and etched for 20 seconds with 37% phosphoric acid gel. In one group, etching gel was not rinsed but dried only. In four groups, gel was ri...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1993-01-01 00:00:00
abstract::Cracked tooth syndrome is known to occur most frequently in heavily restored teeth. Nevertheless, when the symptoms occur in intact teeth, there is difficulty in obtaining a correct diagnosis because it is difficult for the dentist to find where the crack is located. This clinical report describes the diagnostic proce...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/13-257
更新日期:2014-09-01 00:00:00
abstract:OBJECTIVES:Inadequately polymerized resin cements may negatively affect the clinical performance of cemented all-ceramic restorations. The purpose of this in vitro study was to evaluate the effect of ceramic thickness and shade on the microhardness of various light-cured (LC) and dual-cured (DC) resin cements. The amou...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/10-206-L
更新日期:2011-11-01 00:00:00
abstract::This study examined the effect of different light activation modes for light-cured resin-based composites on the shear bond strength to dentin of two one-bottle adhesives with differing acidity. In this experimental study, a flat middle dentin surface was prepared on 110 extracted sound molars using a 600-grit polish ...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/08-048-L
更新日期:2009-09-01 00:00:00
abstract::Good wettability is one of the desirable physical properties of mercury-free gallium-based alloys (Gallium Alloy GF). However, wettability, while providing good adhesion to the cavity wall, has the adverse effect of causing stickiness to the inside of the capsule during mixing, and also to the metal hand instruments u...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1996-01-01 00:00:00
abstract:OBJECTIVE:This in vitro study evaluated the effect of polishing with different polishing systems on the surface roughness and gloss of commercial composites. METHODS:One hundred disk-shaped specimens (10 mm in diameter × 2 mm thick) were made with Filtek P-90, Filtek Z350 XT, Opallis, and Grandio. The specimens were m...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/14-014L
更新日期:2015-07-01 00:00:00
abstract:CLINICAL RELEVANCE:New dual-cure bulk-fill composites show promise for uniform degree of conversion and microhardness throughout the entire depth of direct restorations. SUMMARY: ...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/19-074-L
更新日期:2020-07-01 00:00:00
abstract:PURPOSE:To investigate the effect of different light-curing units and depths on the degree of conversion (DC) through Fourier transform infrared spectroscopy (FTIR) and Knoop Hardness Number (KHN) of a silorane-based composite resin (Filtek LS, 3M ESPE, St Paul, MN, USA) (LS). MATERIALS AND METHODS:LS specimens mounte...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/12-479
更新日期:2014-05-01 00:00:00
abstract::This study compared the clinical performance of a nanofilled resin composite for posterior restorations with 2 microhybrid and 1 packable composite after 12 months of clinical service. Forty-two patients with at least 5 Class I or II restorations under occlusion were enrolled in this study. A total of 148 restorations...
journal_title:Operative dentistry
pub_type: 杂志文章,随机对照试验
doi:10.2341/05-103
更新日期:2006-07-01 00:00:00
abstract::Provisional restorations of full crown preparations may permit more microleakage of bacteria and their products than the final castings do. However, most investigations of the sealing qualities of cemented castings have reported that they too permit dye leakage. One approach to the problem is to seal the dentin with d...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1992-01-01 00:00:00
abstract::Marginal adaptation to cylindrical dentin preparations of five commercially available dental composites--Charisma, Estelite, Herculite, Pertac, and Silux Plus--and seven experimental dental composites containing prepolymerized filler was evaluated by measurement of the wall-to-wall polymerization contraction gaps. The...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1997-11-01 00:00:00
abstract::SmartPrep is a rotating instrument for dentin caries excavation made from a special polymer. The manufacturer's product information stated that SmartPrep removes carious dentin selectively. This in vitro study compared the efficiency of SmartPrep with conventional tungsten carbide bud burs. Fifty extracted teeth were ...
journal_title:Operative dentistry
pub_type: 杂志文章,随机对照试验
doi:10.2341/05-24
更新日期:2006-03-01 00:00:00
abstract:OBJECTIVE:The purpose of this study was to evaluate the effects of different desensitizing agents on the prevention of root caries when applied to root surfaces. MATERIALS AND METHODS:Thirty human roots were sectioned into quarters with a 3 × 4 mm window. A desensitizer (VX, Clinpro™ XT Varnish; SP, Seal & Protect®; o...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/11-007-L
更新日期:2012-05-01 00:00:00
abstract::The aim of this study was to compare five all-in-one bonding agents with respect to microleakage, microtensile bond strength (μTBS), degree of conversion (DC) and the impact of cavity configuration. The materials tested were Adper Easy Bond, Clearfil S3 Bond, iBond, Optibond All-in-One, Xeno IV, and Adper Single Bond ...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/14-185-LR1
更新日期:2015-09-01 00:00:00
abstract::The purpose of this study was to find out the degree to which eugenol-containing temporary cements or temporary filling materials affected shear bond strength of a dual-cure resin luting cement to acid-etched enamel. For this purpose 56 human caries-free third molars were embedded in acrylic resin and cross sectioned ...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1998-03-01 00:00:00
abstract::This study compared the post-gel contraction of two "low-shrinkage" composites (InTen-S [IS], Ivoclar-Vivadent; Aelite LS [AL], BISCO Inc) and an ormocer (Admira [AM], Voco) to two conventional mini-filled composites (Renew [RN], BISCO; Z100 [ZO], 3M ESPE). A strain-monitoring device and test configuration were used t...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2004-03-01 00:00:00
abstract::The purpose of this double-blind clinical trial was to compare the retention rate in noncarious Class V lesions of two resin-based composite restorative materials with contrasting stiffness. Isolation with retraction cord, pressed paper triangles, and cotton rolls was used to closely mimic the procedures generally use...
journal_title:Operative dentistry
pub_type: 临床试验,杂志文章,随机对照试验
doi:
更新日期:2000-01-01 00:00:00
abstract::The purpose of this study was to determine if the actual concentration of bleaching agents available in four different countries were the same as the label indicated and within the recommendations of the International Standard on Tooth Whitening. The method recommended for assaying peroxide by the United States Pharma...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/11-367-L
更新日期:2013-05-01 00:00:00
abstract::The clinical performance of light curing resin composites is greatly influenced by the quality of the light-curing unit (LCU). Halogen LCUs are commonly used for curing composite materials. However, they have some drawbacks. The development of new, blue, super bright light emitting diodes (LED LCU) of 470-nm wavelengt...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2005-01-01 00:00:00
abstract::The purpose of this study was to evaluate the 1-year results of the dentin bond (DBS)/viscous resin liner combinations Amalgambond Plus, Tenure/Panavia, Syntac/Dual Cem, and All-Bond 2/Liner F in reducing microleakage in class 5 cavity preparations restored with an admixed or a spherical amalgam alloy and to compare t...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1998-01-01 00:00:00
abstract::This study investigated the effect of two base materials with different elastic moduli (F2000 and Vitrebond) on the fracture load of machinable ceramic inlays. Standardized MOD cavities were prepared in 18 human maxillary first or second premolars. The teeth were randomly assigned to three groups of six premolars each...
journal_title:Operative dentistry
pub_type: 杂志文章,随机对照试验
doi:10.2341/05-3
更新日期:2006-03-01 00:00:00
abstract:OBJECTIVES:This study evaluated the bond strength of luting systems for bonding glass fiber posts to root canal dentin. The hypothesis tested was that there are no differences in bond strength of glass fiber posts luted with different cement systems. METHODS:Forty bovine incisors were randomly assigned to five differe...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/11-035-L
更新日期:2012-01-01 00:00:00
abstract:STATEMENT OF THE PROBLEM:Precise shade matching can be one of the most difficult tasks for the dentist and some variables may influence the process of shade comparison. PURPOSE OF THE STUDY:This study tested the differences in shade perception between genders, the influence of the observer's clinical experience, and t...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/10-057-C
更新日期:2012-05-01 00:00:00
abstract::This study investigated the effectiveness of cure and post-gel shrinkage of three visible light-cured composite resins (In Ten-S [IT], Ivoclar Vivadent; Z100 [ZO], 3M-ESPE; Tetric Ceram [TC], Ivoclar Vivadent) when polymerized with a very high intensity (1296 +/- 2 mW/cm2) halogen light (Astralis 10, Ivoclar Vivadent)...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2003-07-01 00:00:00