Effect of Thermocycling, Degree of Conversion, and Cavity Configuration on the Bonding Effectiveness of All-in-One Adhesives.

Abstract:

:The aim of this study was to compare five all-in-one bonding agents with respect to microleakage, microtensile bond strength (μTBS), degree of conversion (DC) and the impact of cavity configuration. The materials tested were Adper Easy Bond, Clearfil S3 Bond, iBond, Optibond All-in-One, Xeno IV, and Adper Single Bond Plus as a control. The DC of each adhesive was measured on the surfaces of dentin discs (n=5) by attenuated total reflectance Fourier transform infrared spectroscopy. One hundred and forty-four extracted human molars were randomly divided and assigned to one of the five tested adhesives and the control group. The μTBS to dentin was measured on flat occlusal dentin with and without thermocycling and to the gingival floor dentin of class II cavities (n=8). All specimens were restored with Filtek Z250 resin composite. Class II samples were immersed in a 5% methylene blue dye solution for 24 hours, and microleakage was examined under a stereomicroscope. Micromorphological analysis of demineralized/deproteinized specimens was done using scanning electron microscopy. The DC and microleakage data were statistically analyzed by one-way analysis of variance (ANOVA) and μTBS data by two-way ANOVA followed by a Bonferroni multiple comparison post hoc test (α=0.05) and Weibull-distribution survival analysis. The relation between different variables and μTBS and microleakage was tested by the Pearson correlation coefficient and regression statistics. A moderate direct relation between DC and μTBS durability was found for all the adhesives tested. Significant wide variations exist among the results obtained for single-bottle adhesives tested regarding their μTBS and microleakage. Some of the all-in-one materials tested have shown significantly inferior results under a high C-factor or after aging. The use of these materials should be carefully considered.

journal_name

Oper Dent

journal_title

Operative dentistry

authors

El-Damanhoury HM,Gaintantzopoulou M

doi

10.2341/14-185-LR1

subject

Has Abstract

pub_date

2015-09-01 00:00:00

pages

480-91

issue

5

eissn

0361-7734

issn

1559-2863

journal_volume

40

pub_type

杂志文章
  • Effect of Bleaching Gel Viscosity on Tooth Whitening Efficacy and Pulp Chamber Penetration: An In Vitro Study.

    abstract:OBJECTIVES:Whitening efficacy has been related to hydrogen peroxide (HP) diffusion into tooth structure. However, little information is available relating rheological properties to whitening efficacy. The purpose was to evaluate the whitening efficacy and HP penetration level of a 10% HP gel at three different viscosit...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/17-099-L

    authors: Kwon SR,Pallavi F,Shi Y,Oyoyo U,Mohraz A,Li Y

    更新日期:2018-05-01 00:00:00

  • Depth-dependence of Degree of Conversion and Microhardness for Dual-cure and Light-cure Composites.

    abstract:CLINICAL RELEVANCE:New dual-cure bulk-fill composites show promise for uniform degree of conversion and microhardness throughout the entire depth of direct restorations. SUMMARY: ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/19-074-L

    authors: Wang R,Wang Y

    更新日期:2020-07-01 00:00:00

  • Adhesive Cementation Promotes Higher Fatigue Resistance to Zirconia Crowns.

    abstract:OBJECTIVE:The aim of this study was to investigate the influence of the cementation strategy on the fatigue resistance of zirconia crowns. The null hypothesis was that the cementation strategy would not affect the fatigue resistance of the crowns. METHODS AND MATERIALS:Seventy-five simplified molar tooth crown prepara...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/16-002-L

    authors: Campos F,Valandro LF,Feitosa SA,Kleverlaan CJ,Feilzer AJ,de Jager N,Bottino MA

    更新日期:2017-03-01 00:00:00

  • Effect of power density on shrinkage of dental resin materials.

    abstract::This study compares volumetric changes and rates of shrinkage during different stages of polymerization of dental resin composites and compomers exposed to the same total energy by using two different combinations of power density and exposure duration. A hybrid composite and its equivalent flowable and a compomer and...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Oberholzer TG,Pameijer CH,Grobler SR,Rossouw RJ

    更新日期:2003-09-01 00:00:00

  • Influence of Conditioning Time of Universal Adhesives on Adhesive Properties and Enamel-Etching Pattern.

    abstract:OBJECTIVES:To evaluate the effect of application protocol in resin-enamel microshear bond strength (μSBS), in situ degree of conversion, and etching pattern of three universal adhesive systems. METHODS AND MATERIALS:Sixty-three extracted third molars were sectioned in four parts (buccal, lingual, and proximals) and di...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/15-213-L

    authors: Cardenas AM,Siqueira F,Rocha J,Szesz AL,Anwar M,El-Askary F,Reis A,Loguercio A

    更新日期:2016-09-01 00:00:00

  • Microleakage of dentin/amalgam alloy bonding agents: results after 1 year.

    abstract::The purpose of this study was to evaluate the 1-year results of the dentin bond (DBS)/viscous resin liner combinations Amalgambond Plus, Tenure/Panavia, Syntac/Dual Cem, and All-Bond 2/Liner F in reducing microleakage in class 5 cavity preparations restored with an admixed or a spherical amalgam alloy and to compare t...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Meiers JC,Turner EW

    更新日期:1998-01-01 00:00:00

  • Effect of light intensity and exposure duration on cure of resin composite.

    abstract::Of the many factors under their control, clinicians can manipulate light-exposure duration but must deal with a set intensity of light emitted from the dental curing unit. This research investigates the interdependence of exposure duration and source intensity on resin cure at various depths within a simulated light-c...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Rueggeberg FA,Caughman WF,Curtis JW Jr

    更新日期:1994-01-01 00:00:00

  • In vivo examination of the Scotchbond Multi-Purpose Dental Adhesive System in rat (vitalmicroscopic study).

    abstract::No data are available on the direct acute vascular effect of dental bonding materials on the dental pulp. This study investigated the effects of the components of a composite resin-bonding system on pulpal vascular diameter. Three groups of 10 male Sprague-Dawley rats (weighing 330 +/- 51 g) were used for this investi...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Iványi I,Balogh AE,Rosivall L,Nyárasdy I

    更新日期:2000-09-01 00:00:00

  • Cytotoxicity evaluation of single component dentin bonding agents.

    abstract::This study evaluated the cytotoxicity of four single component dentin bonding agents: Syntac Single Component, Prime & Bond 2.1, Single Bond and One Up Bond F. The test materials were applied on dentin discs of dentin barrier models in the same way as in the clinical procedures recommended by each manufacturer. Cell v...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Vajrabhaya LO,Pasasuk A,Harnirattisai C

    更新日期:2003-07-01 00:00:00

  • Bulk-fill resin composites: polymerization contraction, depth of cure, and gap formation.

    abstract::The bulk-filling of deep, wide dental cavities is faster and easier than traditional incremental restoration. However, the extent of cure at the bottom of the restoration should be carefully examined in combination with the polymerization contraction and gap formation that occur during the restorative procedure. The a...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/13-324-L

    authors: Benetti AR,Havndrup-Pedersen C,Honoré D,Pedersen MK,Pallesen U

    更新日期:2015-03-01 00:00:00

  • Sudden Onset of Subcutaneous Air Emphysema After the Application of Air to a Maxillary Premolar Located in a Nonsurgical Field.

    abstract::Although rare, subcutaneous air emphysema can occur during dental procedures such as endodontic treatment, surgical extractions, and preparing a tooth for an indirect or direct dental restoration. We report the development of a subcutaneous air emphysema that was introduced through the periodontal ligament of an untre...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/15-155-S

    authors: Van Tubergen EA,Tindle D,Fox GM

    更新日期:2017-09-01 00:00:00

  • Cracked tooth syndrome in an unrestored maxillary premolar: a case report.

    abstract::Cracked tooth syndrome is known to occur most frequently in heavily restored teeth. Nevertheless, when the symptoms occur in intact teeth, there is difficulty in obtaining a correct diagnosis because it is difficult for the dentist to find where the crack is located. This clinical report describes the diagnostic proce...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/13-257

    authors: Batalha-Silva S,Gondo R,Stolf SC,Baratieri LN

    更新日期:2014-09-01 00:00:00

  • Influence of bleaching agents and desensitizing varnishes on the water content of dentin.

    abstract::This in vitro study investigated the possible dehydration of dentin caused by bleaching agents. Furthermore, it tested whether protective dentin varnishes can maintain the physiological moisture of dentin during bleaching treatment. Fifty-five standardized dentin cylinders were prepared from freshly extracted bovine i...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/05-89

    authors: Betke H,Kahler E,Reitz A,Hartmann G,Lennon A,Attin T

    更新日期:2006-09-01 00:00:00

  • The Effect of Resin-modified Glass-ionomer Cement Base and Bulk-fill Resin Composite on Cuspal Deformation.

    abstract:OBJECTIVES:This study investigated cuspal deformation in teeth restored with different types of adhesive materials with and without a base. METHODS:Mesio-occluso-distal slot cavities of moderately large dimension were prepared on extracted maxillary premolars (n=24). Teeth were assigned to one of four groups and resto...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/14-331-L

    authors: Nguyen KV,Wong RH,Palamara J,Burrow MF

    更新日期:2016-03-01 00:00:00

  • The effect of energy application sequence on the microtensile bond strength of different C-factor cavity preparations.

    abstract::This study investigated the effect of three equivalent radiant exposure energy application sequences (EASs): high intensity power (HIP: 1,177 mW/cm2, 40 seconds), low intensity power (LOP: 573 mW/cm2, 71 seconds) and ramp (RMP: 650 mW/cm2, 5 seconds, then the irradiance increases to 1047 mW/cm2, 37 seconds) on the mic...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/06-30

    authors: Maghaireh G,Bouschlicher MR,Qian F,Armstrong SR

    更新日期:2007-03-01 00:00:00

  • Effect of Surface Sealants and Polishing Time on Composite Surface Roughness and Microhardness.

    abstract::The objective of this study was to evaluate the effect of surface sealants and polishing delay time on a nanohybrid resin composite roughness and microhardness. Eighty disc specimens were made with a nanohybrid resin (Esthet-X HD, Dentsply). The specimens were divided into two groups (n=40) according to polishing time...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/17-048-L

    authors: Ruschel VC,Bona VS,Baratieri LN,Maia HP

    更新日期:2018-07-01 00:00:00

  • Efficacy testing of visible-light-curing units.

    abstract::This study evaluated (1) the effect of known reductions in the output of curing lights on the depth of cure of various resins as determined by hardness measurements, and (2) the ability of the clinician to detect reduced light output by use of an explorer to compare the hardness of the top and bottom surfaces of resin...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Fowler CS,Swartz ML,Moore BK

    更新日期:1994-03-01 00:00:00

  • Class II composite restorations: importance of cervical enamel in vitro.

    abstract:OBJECTIVE:This study evaluated the importance of enamel at the cervical margin for support and retention of a class II composite restoration in relation to fracture strength, fracture mode, and leakage. METHODS:Sixty-five newly extracted teeth were randomly divided into five groups. Within each group, standardized cla...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/10-126-L

    authors: Laegreid T,Gjerdet NR,Vult von Steyern P,Johansson AK

    更新日期:2011-03-01 00:00:00

  • Short-term dentin bridging of mechanically-exposed pulps capped with adhesive resin systems.

    abstract::Dentin bridging of 150 mechanically exposed monkey pulps to two adhesive resins [BondWell LC (BW); Clearfil Liner Bond II (LB)] and a calcium hydroxide cement [Dycal (DY)] were histopathologically evaluated at 3, 7, 14, 30, and 60 days after operation (n = 10). The dentin bridge structure was three-dimensionally recon...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Kitasako Y,Shibata S,Pereira PN,Tagami J

    更新日期:2000-05-01 00:00:00

  • Randomized Clinical Trial to Evaluate MTA Indirect Pulp Capping in Deep Caries Lesions After 24-Months.

    abstract:OBJECTIVE:This clinical study aimed to assess the efficacies of mineral trioxide aggregate (MTA) and calcium hydroxide [Ca(OH)2] in the treatment of deep carious lesions by the direct complete caries removal technique. METHODS AND MATERIALS:A total of 100 permanent molar/premolar teeth were capped with either Ca(OH)2 ...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/16-110-C

    authors: Koc Vural U,Kiremitci A,Gokalp S

    更新日期:2017-09-01 00:00:00

  • Restoration of occlusal vertical dimension in dental erosion caused by gastroesophageal reflux: case report.

    abstract::The authors describe a minimally invasive procedure for occlusal rehabilitation in a young patient presenting with mild mandibular prognathism and loss of occlusal vertical dimension caused by dental erosion from chronic gastroesophageal reflux. ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/09-110T

    authors: Reston EG,Closs LQ,Busato AL,Broliato GA,Tessarollo FR

    更新日期:2010-01-01 00:00:00

  • Coronal fractures in posterior teeth.

    abstract::Coronal fractures of posterior teeth are not rare in clinical practice. Most of the time they constitute a restorational problem for the clinician, since they usually end below the free gingival crest. Two hundred coronal fractures of posterior teeth were examined in this study, with respect to several factors. Some o...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Lagouvardos P,Sourai P,Douvitsas G

    更新日期:1989-01-01 00:00:00

  • Load capability of excessively flared teeth restored with fiber-reinforced composite posts and all-ceramic crowns.

    abstract::This investigation evaluated the stabilizing effect of glass fiber reinforced posts (FRP) luted with self-adhesive universal cement on the fracture resistance of excessively flared endodontically treated teeth (ETT). Values were compared to teeth with no ferrule, 2 mm ferrule and resin cement for luting with 2 mm ferr...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/05-142

    authors: Naumann M,Preuss A,Frankenberger R

    更新日期:2006-11-01 00:00:00

  • Comparison of surface finish of new aesthetic restorative materials.

    abstract::This study compared the surface finish of eight different types of aesthetic restorative materials. The materials included resin-modified (Fuji II LC [FL], GC) and highly viscous (Fuji IX GP Fast [FN], GC) glass ionomer cements, a compomer (F2000 [FT], 3M-ESPE), minifilled (Z100 [ZO], 3M-ESPE) and microfilled (A110 [A...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Yap AU,Yap SH,Teo CK,Ng JJ

    更新日期:2004-01-01 00:00:00

  • Post-gel shrinkage strain and degree of conversion of preheated resin composite cured using different regimens.

    abstract:OBJECTIVES:This study investigated the influence of resin composite preheating temperature, light curing regimen (mode and duration) on post-gel shrinkage strain (PGSS) and degree of conversion (DC) of a restorative resin composite. METHODS:A hybrid resin composite preheated to three different temperatures (37 degrees...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/09-072-L

    authors: El-Korashy DI

    更新日期:2010-03-01 00:00:00

  • Accuracy of ceramic restorations made using an in-office optical scanning technique: an in vitro study.

    abstract::The present in vitro study concerns determination of the pre-cementation gap width of all-ceramic crowns made using an in-office digital-impression technique and subsequent computer-aided design/computer-aided manufacturing (CAD/CAM) production. Two chairside video camera systems were used: the Lava Oral scanner and C...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/12-309-L

    authors: Tidehag P,Ottosson K,Sjögren G

    更新日期:2014-05-01 00:00:00

  • Comparative study of the effects of two bleaching agents on oral microbiota.

    abstract::This study evaluated the in vivo effects of bleaching agents containing 10% carbamide peroxide (Platinum/Colgate) or 7.5% hydrogen peroxide (Day White 2Z/Discus Dental) on mutans Streptococcus during dental bleaching. The products were applied on 30 volunteers who needed dental bleaching. In each volunteer, one of the...

    journal_title:Operative dentistry

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:

    authors: Alkmin YT,Sartorelli R,Flório FM,Basting RT

    更新日期:2005-07-01 00:00:00

  • Can Silanization Increase the Retention of Glass-fiber posts? A Systematic Review and Meta-analysis of In Vitro Studies.

    abstract::The role of silanes in the bonding of resin luting agents to glass-fiber posts (GFPs) is a controversial topic, and the question still remains whether post silanization is able to improve the retention of GFPs luted into root canals. Thus, this study was designed to determine whether evidence exists to justify silaniz...

    journal_title:Operative dentistry

    pub_type: 杂志文章,meta分析

    doi:10.2341/14-330-O

    authors: Moraes AP,Sarkis-Onofre R,Moraes RR,Cenci MS,Soares CJ,Pereira-Cenci T

    更新日期:2015-11-01 00:00:00

  • Tridimensional Evaluation of the Interfacial Gap in Deep Cervical Margin Restorations: A Micro-CT Study.

    abstract:CLINICAL RELEVANCE:Using a material that optimizes marginal seal when using a margin elevation technique to manage deep class II cavities should enhance clinical outcomes. SUMMARY:Objectives: The purpose of this laboratory study was to perform a tridimensional interfacial gap evaluation of class II cavities with ename...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/19-161-L

    authors: Scotti N,Baldi A,Vergano EA,Tempesta RM,Alovisi M,Pasqualini D,Carpegna GC,Comba A

    更新日期:2020-09-01 00:00:00

  • Microleakage resistance of minimally invasive Class I flowable composite restorations.

    abstract::Minimally invasive flowable composite Class I restorations are widely used. However, flowable composites are characterized by low filler contents, modified resin formulations, low moduli of elasticity, low viscosity, generally poor mechanical properties, and decreased long-term stability. The purpose of this study was...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/11-106-L

    authors: Bonilla ED,Stevenson RG,Caputo AA,White SN

    更新日期:2012-05-01 00:00:00