Efficiency of the polymer bur SmartPrep compared with conventional tungsten carbide bud bur in dentin caries excavation.

Abstract:

:SmartPrep is a rotating instrument for dentin caries excavation made from a special polymer. The manufacturer's product information stated that SmartPrep removes carious dentin selectively. This in vitro study compared the efficiency of SmartPrep with conventional tungsten carbide bud burs. Fifty extracted teeth were split in the center of a carious lesion. The 100 specimens were randomly divided into five groups. Five dentists were asked to excavate 10 teeth each: one half with SmartPrep and the corresponding half with conventional bud burs. The time needed for the caries excavation was measured. Subsequently, histological specimens were produced from all cavities and analyzed by light-microscope after Mallory-Azan-staining. The thickness of the remaining caries was measured (< 1 mm or > 1 mm). The time expended was analyzed using the paired t-test. The results were analyzed for the remaining caries and thickness of the carious layer for every tooth, using the non-parametric Wilcoxon test for combined random samples. A binary logistical regression was performed to determine the influence of the three variables (tooth, sections or bur) on the criteria "caries" or "carious layer thickness (> 1 mm)." The average time to excavate a cavity with SmartPrep was 208.1 seconds, and it was 228.32 seconds with conventional bud burs. The difference between the recorded times was not statistically significant (p > 0.05). In 37 of 50 teeth, the number of carious sections was higher in the SmartPrep group than in the bud bur group. In nine teeth, the quantity of carious sections was higher in the bud bur group than in the SmartPrep group. Four teeth showed no difference in the number of carious sections. The results were statistically significantly different (p < 0.001). In 30 teeth, the number of carious sections with a carious layer thicker than 1 mm was higher in the SmartPrep group compared with the bud bur group. In nine teeth, the number of carious sections was higher in the bud bur group than in the SmartPrep group. Eleven teeth showed no difference in thickness of the carious dentin layer. These results were statistically significantly different (p = 0.003). Binary logistical regression showed that only the variable "bur" (bud bur or SmartPrep) influenced the results concerning the criterion "caries" (p < 0.001).

journal_name

Oper Dent

journal_title

Operative dentistry

authors

Dammaschke T,Rodenberg TN,Schäfer E,Ott KH

doi

10.2341/05-24

subject

Has Abstract

pub_date

2006-03-01 00:00:00

pages

256-60

issue

2

eissn

0361-7734

issn

1559-2863

journal_volume

31

pub_type

杂志文章,随机对照试验
  • Effects of light activation, agent concentration, and tooth thickness on dental sensitivity after bleaching.

    abstract:UNLABELLED:Examining three bleaching systems, this in vivo clinical trial evaluated the relationship among tooth sensitivity, light activation, and agent concentration, and it correlated dental sensitivity with tooth thickness. MATERIALS AND METHODS:Eighty-seven volunteer patients were included. Inclusion criteria wer...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/12-335-C

    authors: Moncada G,Sepúlveda D,Elphick K,Contente M,Estay J,Bahamondes V,Fernandez E,Oliveira OB,Martin J

    更新日期:2013-09-01 00:00:00

  • The effect of various surface coatings on fluoride release from glass-ionomer cement.

    abstract::To protect glass-ionomer cement from moisture contamination and dehydration during initial setting, immediate application of a surface coating agent is recommended. This study compared the effect of various surface coatings on F release from glass-ionomer cement. Twenty glass-ionomer cement (Ketac Fil Aplicap) disks (...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Castro GW,Gray SE,Buikema DJ,Reagan SE

    更新日期:1994-09-01 00:00:00

  • The effect of flowable materials on the microleakage of Class II composite restorations that extend apical to the cemento-enamel junction.

    abstract::This in vitro study investigated the effects of a thin layer of flowable composite or compomer on microleakage occurring in Class II packable and nanofilled composite restorations that extend apical to the cemento-enamel junction (CEJ). The current study also investigated any differences in microleakage that occur bet...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/08-91

    authors: Sadeghi M,Lynch CD

    更新日期:2009-05-01 00:00:00

  • Restoration deterioration related to later failure.

    abstract::The purpose of this study was to determine the relationship between the deterioration and the later failure of a very large number of amalgams and anterior resin composites examined over periods of up to 16 years. Assessments were made of the deterioration of various clinical factors or characteristics of the restorat...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Smales RJ,Webster DA

    更新日期:1993-07-01 00:00:00

  • Shear bond strengths of composite to dentin using six dental adhesive systems.

    abstract::The development of adhesive agents for bonding composite to dentin has rapidly evolved in recent years. It is postulated that dentin bond strengths in the range of 17 MPa are sufficient to resist the polymerization shrinkage of composite resins. The purpose of this study was to evaluate the shear bond strengths of the...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Triolo PT Jr,Swift EJ Jr,Barkmeier WW

    更新日期:1995-03-01 00:00:00

  • Clinical evaluation of a resin-modified glass ionomer adhesive system: results at five years.

    abstract::One hundred non-carious, non-undercut cervical lesions were restored with Silux Plus or Estio LC and bonded with Fuji Bond LC. The restorations were evaluated yearly for retention and marginal discoloration. After five years, the overall retention rate was 96%. Of the 41 restorations examined at five years, five had c...

    journal_title:Operative dentistry

    pub_type: 临床试验,杂志文章

    doi:

    authors: Tyas MJ,Burrow MF

    更新日期:2002-09-01 00:00:00

  • Early fracture resistance of amalgapin-retained complex amalgam restorations.

    abstract::Amalgapins are susceptible to early fracture during matrix removal and carving. The purpose of this study was to examine the early fracture resistance of amalgapin-retained restorations using a spherical amalgam alloy, an admixed amalgam alloy, a combination of admixed alloy over the spherical alloy, and a recently in...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Schulte GA,Hermesch CB,Vandewalle KS,Buikema DJ

    更新日期:1998-03-01 00:00:00

  • Effect of power density on shrinkage of dental resin materials.

    abstract::This study compares volumetric changes and rates of shrinkage during different stages of polymerization of dental resin composites and compomers exposed to the same total energy by using two different combinations of power density and exposure duration. A hybrid composite and its equivalent flowable and a compomer and...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Oberholzer TG,Pameijer CH,Grobler SR,Rossouw RJ

    更新日期:2003-09-01 00:00:00

  • Two-year clinical evaluation of IPS Empress II ceramic onlays/inlays.

    abstract::The stronger the ceramic material, the longer the restoration stays in the mouth. The current study evaluated the two-year clinical performance of a strong ceramic system, IPS Empress II, with increased strength on onlay/inlay restorations of molars. Teeth from 35 patients, including three premolars and 32 molars, wer...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/08-97

    authors: Tagtekin DA,Ozyöney G,Yanikoglu F

    更新日期:2009-07-01 00:00:00

  • Prospective Clinical Study of Zirconia Full-coverage Restorations on Teeth Prepared With Biologically Oriented Preparation Technique on Gingival Health: Results After Two-year Follow-up.

    abstract:OBJECTIVES:To evaluate the clinical behavior of one-piece complete-coverage crowns and fixed partial dentures (FPDs) on teeth with vertical preparation without finish line biologically oriented preparation technique (BOPT). METHODS AND MATERIALS:This prospective study included 52 patients requiring treatment with rest...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/17-124-C

    authors: Agustín-Panadero R,Serra-Pastor B,Fons-Font A,Solá-Ruíz MF

    更新日期:2018-09-01 00:00:00

  • Short-term dentin bridging of mechanically-exposed pulps capped with adhesive resin systems.

    abstract::Dentin bridging of 150 mechanically exposed monkey pulps to two adhesive resins [BondWell LC (BW); Clearfil Liner Bond II (LB)] and a calcium hydroxide cement [Dycal (DY)] were histopathologically evaluated at 3, 7, 14, 30, and 60 days after operation (n = 10). The dentin bridge structure was three-dimensionally recon...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Kitasako Y,Shibata S,Pereira PN,Tagami J

    更新日期:2000-05-01 00:00:00

  • Nanoleakage at the dentin adhesive interface vs microtensile bond strength.

    abstract::Excessive etching of the dentin may decrease bond strength because the adhesive may fail to completely infiltrate to the base of the over-etched demineralized collagen network. The purpose of the present study was to evaluate the influence of increasing etching times on the microtensile bond strength of Single Bond an...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Paul SJ,Welter DA,Ghazi M,Pashley D

    更新日期:1999-05-01 00:00:00

  • Randomized Clinical Trial to Evaluate MTA Indirect Pulp Capping in Deep Caries Lesions After 24-Months.

    abstract:OBJECTIVE:This clinical study aimed to assess the efficacies of mineral trioxide aggregate (MTA) and calcium hydroxide [Ca(OH)2] in the treatment of deep carious lesions by the direct complete caries removal technique. METHODS AND MATERIALS:A total of 100 permanent molar/premolar teeth were capped with either Ca(OH)2 ...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/16-110-C

    authors: Koc Vural U,Kiremitci A,Gokalp S

    更新日期:2017-09-01 00:00:00

  • The effect of distance and tooth structure on laser fluorescence caries detection.

    abstract::The DIAGNOdent, a device used in caries detection, uses a laser to excite fluorescence from pigments in carious tooth structure. In clinical use assessing occlusal surfaces, distance and tooth structure may separate the instrument's tip from the fluorescent source.The aim of this in vitro study was to examine the effe...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/10-179-L

    authors: Markowitz K,Stenvall RM,Graye M

    更新日期:2012-03-01 00:00:00

  • The shear bond strength between luting cements and zirconia ceramics after two pre-treatments.

    abstract::This study evaluated the shear-bond strength of 11 luting cements from different material classes to manufactured pre-treated zirconia ceramics (Lava: 97% ZrO2, stabilized with 3% Y2O3). In addition, the influence of the curing method on shear-bond strength was investigated. The cements examined were one zinc-phosphat...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Piwowarczyk A,Lauer HC,Sorensen JA

    更新日期:2005-05-01 00:00:00

  • The effect of light curing source on the residual yellowing of resin composites.

    abstract:PURPOSE:This study evaluated the amount of residual yellow in cured resin composites when polymerizing with either a quartz-tungsten-halogen (QTH) or blue light-emitting diode (LED). MATERIAL AND METHODS:Twelve shades (bleaching to conventional shades) of microfill, hybrid and microhybrid resin composite specimens (n ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/06-129

    authors: Brackett MG,Brackett WW,Browning WD,Rueggeberg FA

    更新日期:2007-09-01 00:00:00

  • Effect of bleaching on fracture toughness of resin composites.

    abstract::This study determined the effect of bleaching agents on the fracture toughness of composite materials. Four nanofilled resin composites were evaluated: Filtek Supreme Plus, Tetric EvoCeram, Premise and Esthet-X. Four concentrations of bleaching agents were tested: Opalescence PF 10%, 20%, 35% and 45%. Fifty specimens ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/08-120-L

    authors: Cho SD,Bulpakdi P,Matis BA,Platt JA

    更新日期:2009-11-01 00:00:00

  • Longevity of low- and high-copper amalgams analyzed by preparation class, tooth site, patient age, and operator.

    abstract::The purpose of this study was to compare the long-term survivals of two low-copper and three high-copper amalgam alloys, and to analyze four clinical factors for their possible effects on the restoration survivals. Some 1476 polished restorations were placed in hospital patients by a large number of operators and asse...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Smales RJ

    更新日期:1991-09-01 00:00:00

  • Post-gel shrinkage strain and degree of conversion of preheated resin composite cured using different regimens.

    abstract:OBJECTIVES:This study investigated the influence of resin composite preheating temperature, light curing regimen (mode and duration) on post-gel shrinkage strain (PGSS) and degree of conversion (DC) of a restorative resin composite. METHODS:A hybrid resin composite preheated to three different temperatures (37 degrees...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/09-072-L

    authors: El-Korashy DI

    更新日期:2010-03-01 00:00:00

  • The effect of air thinning on dentin adhesive bond strength.

    abstract::The purpose of this study was to determine if air thinning three dentin adhesives would affect bond strength to dentin. Ninety human molars were mounted in acrylic and the occlusal surfaces ground to expose a flat dentin surface. Thirty teeth were randomly assigned to one of the following dentin bonding agent/composit...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Hilton TJ,Schwartz RS

    更新日期:1995-07-01 00:00:00

  • Placement and replacement of amalgam restorations in Italy.

    abstract::The reasons for placement and replacement and the longevity of amalgam restorations were recorded by 62 Italian private practitioners. The survey compiled 1935 amalgam restorations inserted due to primary caries (59%) and failed restorations (41%). The clinical diagnosis of secondary caries constituted 59% of failures...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Mjör IA,Toffenetti F

    更新日期:1992-03-01 00:00:00

  • Effect of Surface Sealants and Polishing Time on Composite Surface Roughness and Microhardness.

    abstract::The objective of this study was to evaluate the effect of surface sealants and polishing delay time on a nanohybrid resin composite roughness and microhardness. Eighty disc specimens were made with a nanohybrid resin (Esthet-X HD, Dentsply). The specimens were divided into two groups (n=40) according to polishing time...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/17-048-L

    authors: Ruschel VC,Bona VS,Baratieri LN,Maia HP

    更新日期:2018-07-01 00:00:00

  • Cytotoxicity evaluation of single component dentin bonding agents.

    abstract::This study evaluated the cytotoxicity of four single component dentin bonding agents: Syntac Single Component, Prime & Bond 2.1, Single Bond and One Up Bond F. The test materials were applied on dentin discs of dentin barrier models in the same way as in the clinical procedures recommended by each manufacturer. Cell v...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Vajrabhaya LO,Pasasuk A,Harnirattisai C

    更新日期:2003-07-01 00:00:00

  • Online Only Articles.

    abstract::On occasion we receive manuscripts that we would like to publish, but do not have the page room to include in the print journal. For the full article, please go to www.jopdentonline.org or enter the provided address into your address bar. ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/1559-2863-43.3.335

    authors:

    更新日期:2018-05-01 00:00:00

  • Surface Roughness and Gloss of Actual Composites as Polished With Different Polishing Systems.

    abstract:OBJECTIVE:This in vitro study evaluated the effect of polishing with different polishing systems on the surface roughness and gloss of commercial composites. METHODS:One hundred disk-shaped specimens (10 mm in diameter × 2 mm thick) were made with Filtek P-90, Filtek Z350 XT, Opallis, and Grandio. The specimens were m...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/14-014L

    authors: Rodrigues-Junior SA,Chemin P,Piaia PP,Ferracane JL

    更新日期:2015-07-01 00:00:00

  • Retentiveness of metal coping luted to teeth of uremic patients undergoing hemodialysis using five different luting cements.

    abstract:OBJECTIVES:This study aimed to assess the retention of metal copings luted to uremic teeth with five different luting agents. METHODS:A total of 35 sound natural molars was collected from uremic patients and randomly assigned into five groups (n=7). The teeth were prepared for metal copings using diamond tips and wate...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/12-523-LR2

    authors: Ghazy MH,Aboumadina MM,Mahmoud SH

    更新日期:2014-05-01 00:00:00

  • Effects of two in-office bleaching agents with different pH on the structure of human enamel: an in situ and in vitro study.

    abstract::This study evaluated the effects of two in-office bleaching agents (Beyond and Opalescence Boost) with different pH on the structure and mechanical properties of human enamel in vitro and in situ. One hundred and eight enamel slabs were obtained from freshly extracted premolars. The specimens were randomly distributed...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/11-173-L

    authors: Sa Y,Sun L,Wang Z,Ma X,Liang S,Xing W,Jiang T,Wang Y

    更新日期:2013-01-01 00:00:00

  • Restoration of Severely Compromised Teeth With Modern Operative Techniques.

    abstract::This case report illustrates how to restore severely compromised teeth with direct composite restorations. The size of the restorations presented is often considered by dentists as being a contraindication for direct composites. Hence, the technique is explained step by step, addressing the crucial points. ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/15-001-T

    authors: Lenhard M

    更新日期:2016-09-01 00:00:00

  • Effect of beverages on color and translucency of new tooth-colored restoratives.

    abstract::This investigation examined the susceptibility to staining and translucency changes of some new tooth-colored restorative materials after immersion in different beverages. The materials studied were 3M Filtek Z350XT (ZT), 3M Filtek 350XT Flowable Restorative (ZF), Shofu Beautifil Flow Plus (BF), Shofu Beautifil II (B2...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/149027-L

    authors: Tan BL,Yap AU,Ma HN,Chew J,Tan WJ

    更新日期:2015-03-01 00:00:00

  • Load capability of excessively flared teeth restored with fiber-reinforced composite posts and all-ceramic crowns.

    abstract::This investigation evaluated the stabilizing effect of glass fiber reinforced posts (FRP) luted with self-adhesive universal cement on the fracture resistance of excessively flared endodontically treated teeth (ETT). Values were compared to teeth with no ferrule, 2 mm ferrule and resin cement for luting with 2 mm ferr...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/05-142

    authors: Naumann M,Preuss A,Frankenberger R

    更新日期:2006-11-01 00:00:00