The effect of air thinning on dentin adhesive bond strength.

Abstract:

:The purpose of this study was to determine if air thinning three dentin adhesives would affect bond strength to dentin. Ninety human molars were mounted in acrylic and the occlusal surfaces ground to expose a flat dentin surface. Thirty teeth were randomly assigned to one of the following dentin bonding agent/composite combinations: A) Universal Bond 3/TPH (Caulk), B) All-Bond 2/Bis-Fil-P (Bisco), and C) Scotchbond Multi-Purpose/Z-100 (3m). The primers were applied following the manufacturers' instructions. The adhesives were applied by two methods. A thin layer of adhesive was applied with a brush to 15 specimens in each group and light cured. Adhesive was brushed on to the remaining 15 teeth in the group, air thinned for 3 seconds, and then polymerized. The appropriate composite was applied in 2 mm increments and light cured utilizing a 5 mm-in-diameter split Teflon mold. Following 3 months of water storage, all groups were shear tested to failure on an Instron Universal Testing Machine. Bond strength was significantly higher in all groups when the dentin bonding agent was painted on without being air thinned. Scotchbond Multi-Purpose had significantly higher bond strength than All-Bond 2, which had significantly higher bond strength than Universal Bond 3.

journal_name

Oper Dent

journal_title

Operative dentistry

authors

Hilton TJ,Schwartz RS

subject

Has Abstract

pub_date

1995-07-01 00:00:00

pages

133-7

issue

4

eissn

0361-7734

issn

1559-2863

journal_volume

20

pub_type

杂志文章
  • Load capability of excessively flared teeth restored with fiber-reinforced composite posts and all-ceramic crowns.

    abstract::This investigation evaluated the stabilizing effect of glass fiber reinforced posts (FRP) luted with self-adhesive universal cement on the fracture resistance of excessively flared endodontically treated teeth (ETT). Values were compared to teeth with no ferrule, 2 mm ferrule and resin cement for luting with 2 mm ferr...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/05-142

    authors: Naumann M,Preuss A,Frankenberger R

    更新日期:2006-11-01 00:00:00

  • Enamel Microabrasion and Dental Bleaching on Teeth Presenting Severe-pitted Enamel Fluorosis: A Case Report.

    abstract::The present clinical case report describes the clinical steps of enamel microabrasion associated with dental bleaching to restore severely-pitted fluorosed teeth. The process of removing the fluorotic superficial stains started by using macroabrasion with a water-cooled fine tapered 3195 FF diamond bur. Rubber dam iso...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/18-116-T

    authors: Sundfeld D,Pavani CC,Pini N,Machado LS,Schott TC,Sundfeld RH

    更新日期:2019-11-01 00:00:00

  • Effect of LED curing modes on cusp deflection and hardness of composite restorations.

    abstract::This in vitro study measured cusp deflection associated with MOD resin composite restorations in maxillary premolars with different curing light modes. Soft-start polymerization may reduce cusp deflection by reducing polymerization shrinkage stress. Forty maxillary premolars were mounted in stone and slot MOD cavities...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:

    authors: Alomari QD,Mansour YF

    更新日期:2005-11-01 00:00:00

  • Fluoride release from fluoride-containing materials.

    abstract::This in vitro study evaluated the amount of fluoride released from fluoride-containing materials over a period of 28 days. Six disk samples (2.06 +/- 0.06 cm2) were prepared of each material and divided at random into seven groups: Group 1: Chelon-Fil; Group 2: Chelon-Silver; Group 3: VariGlass; Group 4: Dyract; Group...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: de Araujo FB,García-Godoy F,Cury JA,Conceição EN

    更新日期:1996-09-01 00:00:00

  • Retentiveness of metal coping luted to teeth of uremic patients undergoing hemodialysis using five different luting cements.

    abstract:OBJECTIVES:This study aimed to assess the retention of metal copings luted to uremic teeth with five different luting agents. METHODS:A total of 35 sound natural molars was collected from uremic patients and randomly assigned into five groups (n=7). The teeth were prepared for metal copings using diamond tips and wate...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/12-523-LR2

    authors: Ghazy MH,Aboumadina MM,Mahmoud SH

    更新日期:2014-05-01 00:00:00

  • Effect of eugenol-containing temporary cements on bond strength of composite to enamel.

    abstract::The purpose of this study was to find out the degree to which eugenol-containing temporary cements or temporary filling materials affected shear bond strength of a dual-cure resin luting cement to acid-etched enamel. For this purpose 56 human caries-free third molars were embedded in acrylic resin and cross sectioned ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Jung M,Ganss C,Senger S

    更新日期:1998-03-01 00:00:00

  • Effect of fractured or sectioned fragments on the fracture strength of different reattachment techniques.

    abstract::This study evaluated the effect of fractured or sectioned fragments on the fracture strength recovery of four techniques used for reattachment and resin composite buildups. Ninety-one sound, permanent lower central incisors were used. Half the teeth were fractured in the incisal-proximal edge; the other half had the i...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Loguercio AD,Mengarda J,Amaral R,Kraul A,Reis A

    更新日期:2004-05-01 00:00:00

  • Barcoll hardness of different resin-based composites cured by halogen or light emitting diode (LED).

    abstract::The clinical performance of light curing resin composites is greatly influenced by the quality of the light-curing unit (LCU). Halogen LCUs are commonly used for curing composite materials. However, they have some drawbacks. The development of new, blue, super bright light emitting diodes (LED LCU) of 470-nm wavelengt...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Bala O,Uçtasli MB,Tüz MA

    更新日期:2005-01-01 00:00:00

  • Effect of preliminary treatment of the dentin surface on the shear bond strength of resin composite to dentin.

    abstract::This study evaluated the effect of two dentin disinfectants (Consepsis, Tubulicid), one aqueous HEMA solution (Aqua Prep), a combination of Aqua Prep and Tubulicid and an air abrasion treatment (50 microns aluminum oxide) on the shear bond strength (SBS) of two acetone-based single bottle adhesives (One Step and Prime...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Pilo R,Cardash HS,Oz-Ari B,Ben-Amar A

    更新日期:2001-11-01 00:00:00

  • Six-month Follow-up of the Effect of Nonvital Bleaching on IL-1β and RANK-L: A Randomized Clinical Trial.

    abstract:OBJECTIVES:It has been reported that bleaching generates an increase in the activity of osteoclasts in vitro. We quantified the RANK-L and IL-1β biomarkers in a double-blind, randomized clinical trial evaluating the in vivo effect of hydrogen peroxide (35%) and peroxide carbamide (37%) six months after whitening. METH...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/18-023-C

    authors: Bersezio C,Estay J,Sáez M,Sánchez F,Vernal R,Fernández E

    更新日期:2019-11-01 00:00:00

  • Online Only Articles.

    abstract::On occasion we receive manuscripts that we would like to publish, but do not have the page room to include in the print journal. For the full article, please go to www.jopdentonline.org or enter the provided address into your address bar. ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/1559-2863-43.5.561

    authors:

    更新日期:2018-09-01 00:00:00

  • Marginal adaptation of dental composites containing prepolymerized filler.

    abstract::Marginal adaptation to cylindrical dentin preparations of five commercially available dental composites--Charisma, Estelite, Herculite, Pertac, and Silux Plus--and seven experimental dental composites containing prepolymerized filler was evaluated by measurement of the wall-to-wall polymerization contraction gaps. The...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Yukitani W,Hasegawa T,Itoh K,Hisamitsu H,Wakumoto S

    更新日期:1997-11-01 00:00:00

  • Two-year clinical performance of a low-shrinkage composite in posterior restorations.

    abstract:OBJECTIVES:The aim of this study was to compare the two-year clinical performance of three restorative systems in posterior restorations, which included a low-shrinkage composite and both etch-and-rinse and self-etch adhesive strategies. MATERIALS AND METHODS:After signing an informed consent, 25 patients received thr...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/12-364-C

    authors: Baracco B,Perdigão J,Cabrera E,Ceballos L

    更新日期:2013-11-01 00:00:00

  • Repair of non-carious amalgam margin defects.

    abstract::This study investigated the microleakage associated with the repair of non-carious amalgam defects using flowable resin composite. Occlusal amalgam preparations were accomplished on 36 non-carious mandibular molars. A standardized 40-micron marginal defect was made by condensing amalgam against a mylar matrix strip. S...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Roberts HW,Charlton DG,Murchison DF

    更新日期:2001-05-01 00:00:00

  • Quantitative evaluation of approximal contacts in Class 2 composite resin restorations: a clinical study.

    abstract::The purpose of this study was to develop an accurate and reproducible intraoral method of measuring the distance between two teeth, and to conduct a clinical pilot study of the effect of placement of a class 2 posterior resin restoration upon this intertooth dimension. A Kaman Sciences KD-2611 noncontact displacement ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Wang JC,Charbeneau GT,Gregory WA,Dennison JB

    更新日期:1989-10-01 00:00:00

  • Factors affecting light transmission of single-use, plastic light-curing tips.

    abstract::Recently, manufacturers introduced presterilized, single-use, plastic light-curing tips to be used either routinely or on patients with known or questionable communicable health concerns. The purpose of this study was to examine the effect of these single-use tips on light transmission compared to conventional fiber-o...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Rueggeberg FA,Caughman WF

    更新日期:1998-07-01 00:00:00

  • Two-year clinical comparison of a microfilled and a hybrid resin-based composite in non-carious Class V lesions.

    abstract::The purpose of this double-blind clinical trial was to compare the retention rate in noncarious Class V lesions of two resin-based composite restorative materials with contrasting stiffness. Isolation with retraction cord, pressed paper triangles, and cotton rolls was used to closely mimic the procedures generally use...

    journal_title:Operative dentistry

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:

    authors: Browning WD,Brackett WW,Gilpatrick RO

    更新日期:2000-01-01 00:00:00

  • In vivo examination of the Scotchbond Multi-Purpose Dental Adhesive System in rat (vitalmicroscopic study).

    abstract::No data are available on the direct acute vascular effect of dental bonding materials on the dental pulp. This study investigated the effects of the components of a composite resin-bonding system on pulpal vascular diameter. Three groups of 10 male Sprague-Dawley rats (weighing 330 +/- 51 g) were used for this investi...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Iványi I,Balogh AE,Rosivall L,Nyárasdy I

    更新日期:2000-09-01 00:00:00

  • Efficacy testing of visible-light-curing units.

    abstract::This study evaluated (1) the effect of known reductions in the output of curing lights on the depth of cure of various resins as determined by hardness measurements, and (2) the ability of the clinician to detect reduced light output by use of an explorer to compare the hardness of the top and bottom surfaces of resin...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Fowler CS,Swartz ML,Moore BK

    更新日期:1994-03-01 00:00:00

  • The influence of surface standardization of lithium disilicate glass ceramic on bond strength to a dual resin cement.

    abstract::In vitro studies to assess bond strength between resins and ceramics have used surfaces that have been ground flat to ensure standardization; however, in patients, ceramic surfaces are irregular. The effect of a polished and unpolished ceramic on bond strength needs to be investigated. Sixty ceramic specimens (20×5×2 ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/11-009-L

    authors: Brum R,Mazur R,Almeida J,Borges G,Caldas D

    更新日期:2011-09-01 00:00:00

  • Labeled vs actual concentration of bleaching agents.

    abstract::The purpose of this study was to determine if the actual concentration of bleaching agents available in four different countries were the same as the label indicated and within the recommendations of the International Standard on Tooth Whitening. The method recommended for assaying peroxide by the United States Pharma...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/11-367-L

    authors: Matis BA,Matis JI,Wang Y,Monteiro S,Al-Qunaian TA,Millard R

    更新日期:2013-05-01 00:00:00

  • Effects of delayed polishing on gap formation of cervical restorations.

    abstract::This study evaluated the effect of polishing after one-day storage in water on the gap formation around a Class V restoration completely bordered by enamel (coronal cavity) using one resin-modified glass ionomer, one compomer and one conventional glass ionomer as a control. The study also examined gap formation of the...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Irie M,Suzuki K

    更新日期:2002-01-01 00:00:00

  • Tooth regeneration in operative dentistry.

    abstract::For many years, operative dentistry has been using regenerative approaches to treat dental disease. The use of calcium hydroxide to stimulate reparative or reactionary dentin is clearly an example of such a therapeutic strategy. The advent of tissue engineering is allowing dentistry to move forward in the use of regen...

    journal_title:Operative dentistry

    pub_type: 杂志文章,评审

    doi:10.2341/06-000

    authors: Nör JE

    更新日期:2006-11-01 00:00:00

  • Enamel Surface Changes After Exposure to Bleaching Gels Containing Carbamide Peroxide or Hydrogen Peroxide.

    abstract:OBJECTIVE:This study evaluated the differences in enamel color change, surface hardness, elastic modulus, and surface roughness between treatments with four bleaching gels containing carbamide peroxide (two at 10% and one each at 35%, and 45%) and two bleaching gels containing hydrogen peroxide (two at 40%). METHODS:E...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/15-010-L

    authors: Cvikl B,Lussi A,Moritz A,Flury S

    更新日期:2016-01-01 00:00:00

  • Effect of composite resin contamination with powdered and unpowdered latex gloves on its shear bond strength to bovine dentin.

    abstract::The aim of the present study was to evaluate the effect of composite resin contamination with powdered and unpowdered latex gloves on the shear bond strength of etch-and-rinse and two-step self-etch adhesive systems. Standard flat dentin surfaces were prepared on the facial aspect of 120 bovine incisors and randomly a...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/11-088-L

    authors: Oskoee SS,Navimipour EJ,Bahari M,Ajami AA,Oskoee PA,Abbasi NM

    更新日期:2012-09-01 00:00:00

  • Effect of Surface Sealants and Polishing Time on Composite Surface Roughness and Microhardness.

    abstract::The objective of this study was to evaluate the effect of surface sealants and polishing delay time on a nanohybrid resin composite roughness and microhardness. Eighty disc specimens were made with a nanohybrid resin (Esthet-X HD, Dentsply). The specimens were divided into two groups (n=40) according to polishing time...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/17-048-L

    authors: Ruschel VC,Bona VS,Baratieri LN,Maia HP

    更新日期:2018-07-01 00:00:00

  • Two-year clinical evaluation of IPS Empress II ceramic onlays/inlays.

    abstract::The stronger the ceramic material, the longer the restoration stays in the mouth. The current study evaluated the two-year clinical performance of a strong ceramic system, IPS Empress II, with increased strength on onlay/inlay restorations of molars. Teeth from 35 patients, including three premolars and 32 molars, wer...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/08-97

    authors: Tagtekin DA,Ozyöney G,Yanikoglu F

    更新日期:2009-07-01 00:00:00

  • Longevity of low- and high-copper amalgams analyzed by preparation class, tooth site, patient age, and operator.

    abstract::The purpose of this study was to compare the long-term survivals of two low-copper and three high-copper amalgam alloys, and to analyze four clinical factors for their possible effects on the restoration survivals. Some 1476 polished restorations were placed in hospital patients by a large number of operators and asse...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Smales RJ

    更新日期:1991-09-01 00:00:00

  • Fracture resistance of extensive amalgam restorations retained by pins, amalgapins and amalgam bonding agents.

    abstract::This in-vitro study compared the resistance of extensive amalgam restorations retained by either four Regular TMS Link Plus pins, four amalgapins, Amalgambond Plus, Amalgambond Plus with HPA, Scotchbond Multi-Purpose Plus, PQ Amalgam, Panavia F 2.0, All-Bond 2 or Resinomer. Ninety caries-free third molars were embedde...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/08-5

    authors: Imbery TA,Coudron J,Moon PC

    更新日期:2008-11-01 00:00:00

  • Failure risk of posterior composites with post-operative sensitivity.

    abstract::Post-operative sensitivity (POS) may be observed in recently placed posterior composites. Evidence-based guidelines for the management of posterior composites with POS have yet to be determined. This study examined a retrospective analysis of the findings of a unique multi-center clinical trial to investigate the five...

    journal_title:Operative dentistry

    pub_type: 临床试验,杂志文章,多中心研究

    doi:

    authors: Hayashi M,Wilson NH

    更新日期:2003-11-01 00:00:00