Effect of bleaching on fracture toughness of resin composites.

Abstract:

:This study determined the effect of bleaching agents on the fracture toughness of composite materials. Four nanofilled resin composites were evaluated: Filtek Supreme Plus, Tetric EvoCeram, Premise and Esthet-X. Four concentrations of bleaching agents were tested: Opalescence PF 10%, 20%, 35% and 45%. Fifty specimens of each composite conforming to ASTM guidelines for the single edge notch bar-shaped specimen were fabricated in a metal mold. The specimens were stored in artificial saliva at 37 degrees C for a minimum of 24 hours prior to exposing them to the bleaching agents. Ten specimens of each material were used as controls. Forty specimens of each brand were evenly divided into four groups for bleaching agent application (n = 10). The resin composites were bleached on both sides for 14 days. The specimens were then subjected to a three-point bending test with a crosshead speed of 0.2 mm per second. The fracture toughness (K(Ic)) was calculated. The control group K(Ic) value of Esthet-X was significantly higher than that of the other composites in the controlled groups. Bleaching agents significantly improved the fracture toughness values of Filtek Supreme Plus. The application of bleaching agents did not significantly change the fracture toughness values of the other nanofilled resin composites tested.

journal_name

Oper Dent

journal_title

Operative dentistry

authors

Cho SD,Bulpakdi P,Matis BA,Platt JA

doi

10.2341/08-120-L

subject

Has Abstract

pub_date

2009-11-01 00:00:00

pages

703-8

issue

6

eissn

0361-7734

issn

1559-2863

journal_volume

34

pub_type

杂志文章
  • Light-emitting Diode Beam Profile and Spectral Output Influence on the Degree of Conversion of Bulk Fill Composites.

    abstract:OBJECTIVES:To evaluate the beam profile and the spectral output of monowave and polywave light-emitting diodes (LEDs) and their influence on the degree of conversion (DC) of bulk fill composites. METHODS:A monowave LED (Smartlite Focus, Dentsply) and a polywave LED (Valo Cordless, Ultradent) were characterized using a...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/16-164-L

    authors: Rocha MG,de Oliveira D,Correa IC,Correr-Sobrinho L,Sinhoreti M,Ferracane JL,Correr AB

    更新日期:2017-07-01 00:00:00

  • Influence of curing lights and modes on cross-link density of dental composites.

    abstract::This study investigated the influence of curing lights and modes on the cross-link density of dental composites. Four LED/halogen curing lights (LED-Elipar Freelight [FL], 3M-ESPE and GC e-light [EL], GC; high intensity halogen-Elipar Trilight [TL], 3M-ESPE; very high intensity halogen-Astralis 10 [AS], Ivoclar Vivade...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Yap AU,Soh MS,Han TT,Siow KS

    更新日期:2004-07-01 00:00:00

  • Curing of pit & fissure sealants using Light Emitting Diode curing units.

    abstract::Light Emitting Diode (LED) curing units are attractive to clinicians, because most are cordless and should create less heat within tooth structure. However, questions about polymerization efficacy have surrounded this technology. This research evaluated the adequacy of the depth of cure of pit & fissure sealants provi...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Platt JA,Clark H,Moore BK

    更新日期:2005-11-01 00:00:00

  • The effect of base materials with different elastic moduli on the fracture loads of machinable ceramic inlays.

    abstract::This study investigated the effect of two base materials with different elastic moduli (F2000 and Vitrebond) on the fracture load of machinable ceramic inlays. Standardized MOD cavities were prepared in 18 human maxillary first or second premolars. The teeth were randomly assigned to three groups of six premolars each...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/05-3

    authors: Banditmahakun S,Kuphausuk W,Kanchanavasita W,Kuphasuk C

    更新日期:2006-03-01 00:00:00

  • The effect of light curing source on the residual yellowing of resin composites.

    abstract:PURPOSE:This study evaluated the amount of residual yellow in cured resin composites when polymerizing with either a quartz-tungsten-halogen (QTH) or blue light-emitting diode (LED). MATERIAL AND METHODS:Twelve shades (bleaching to conventional shades) of microfill, hybrid and microhybrid resin composite specimens (n ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/06-129

    authors: Brackett MG,Brackett WW,Browning WD,Rueggeberg FA

    更新日期:2007-09-01 00:00:00

  • Placement and replacement of amalgam restorations in Italy.

    abstract::The reasons for placement and replacement and the longevity of amalgam restorations were recorded by 62 Italian private practitioners. The survey compiled 1935 amalgam restorations inserted due to primary caries (59%) and failed restorations (41%). The clinical diagnosis of secondary caries constituted 59% of failures...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Mjör IA,Toffenetti F

    更新日期:1992-03-01 00:00:00

  • Effect of C-factor on microtensile bond strengths of low-shrinkage composites.

    abstract:UNLABELLED:This study evaluated the microtensile bond strength (μ-TBS) of low-shrinkage composites with their corresponding adhesive systems, Filtek Silorane/Silorane adhesive (SIL, 3M ESPE AG, Seefeld, Germany) and Aelite LS/One-Step Plus (AL, BISCO Inc, Schaumburg, IL, USA) in cavities with different C-factors. Filte...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/10-105-L

    authors: El-Sahn NA,El-Kassas DW,El-Damanhoury HM,Fahmy OM,Gomaa H,Platt JA

    更新日期:2011-05-01 00:00:00

  • Tooth regeneration in operative dentistry.

    abstract::For many years, operative dentistry has been using regenerative approaches to treat dental disease. The use of calcium hydroxide to stimulate reparative or reactionary dentin is clearly an example of such a therapeutic strategy. The advent of tissue engineering is allowing dentistry to move forward in the use of regen...

    journal_title:Operative dentistry

    pub_type: 杂志文章,评审

    doi:10.2341/06-000

    authors: Nör JE

    更新日期:2006-11-01 00:00:00

  • In Vitro Biocompatibility of Contemporary Bulk-fill Composites.

    abstract::This study evaluated the biocompatibility of contemporary bulk-fill resin-based composites (RBCs) including PRG (pre-reacted glass ionomer) materials based on the International Organization for Standardization 10993. In addition, the effect of composite thickness on cytotoxicity was also assessed. Two standard composi...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/15-059-L

    authors: Toh WS,Yap AU,Lim SY

    更新日期:2015-11-01 00:00:00

  • Reversal of dentin bonding to bleached teeth.

    abstract::Many studies have shown a considerable reduction in enamel bond strength of resin composite restorations when the bonding procedure is carried out immediately after bleaching. These studies claim that a certain waiting period is needed prior to restoration to reach the original bond strength values prior to bleaching....

    journal_title:Operative dentistry

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:

    authors: Kaya AD,Türkün M

    更新日期:2003-11-01 00:00:00

  • Clinical evaluation of DIAGNOdent in detection of occlusal caries in newly erupted noncavitated first permanent molars in caries-active children.

    abstract:OBJECTIVE:The aim of this study was to compare the in vivo diagnostic ability of a laser fluorescence system (DIAGNOdent, KaVo, Biberac, Germany) with that of visual inspection in the early detection of occlusal caries in newly erupted noncavitated first permanent molars among caries-active children. MATERIALS AND MET...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/10-309-C

    authors: Duruturk L,Ciftçi A,Baharoğlu S,Oztuna D

    更新日期:2011-07-01 00:00:00

  • Influence of adhesive application duration on dentin bond strength of single-application bonding systems.

    abstract::This study examined the relationship between the bond agent application duration and the dentin bond strength of several single-application bonding systems. The restorative material/ bonding systems used were Reactmer, with its single-application bonding system Reactmer Bond (RB, Shofu Inc, Kyoto, Japan); Palfique Est...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Miyazaki M,Tsubota K,Onose H,Hinoura K

    更新日期:2002-05-01 00:00:00

  • Effect of light activation mode on the incompatibility between one-bottle adhesives and light-cured composites: an in vitro shear bond strength study.

    abstract::This study examined the effect of different light activation modes for light-cured resin-based composites on the shear bond strength to dentin of two one-bottle adhesives with differing acidity. In this experimental study, a flat middle dentin surface was prepared on 110 extracted sound molars using a 600-grit polish ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/08-048-L

    authors: Shafiei F,Saffarpour A,Moradmand M,Alavi AA

    更新日期:2009-09-01 00:00:00

  • Inactivation of matrix-bound matrix metalloproteinases by cross-linking agents in acid-etched dentin.

    abstract:OBJECTIVES:Published transmission electron microscopy analysis of in vitro resin-dentin bonds shows that, after 44 months, almost 70% of collagen fibrils from the hybrid layer disappear. Matrix metalloproteinases (MMPs) play an important role in that process and are thought to be the main factor responsible for the sol...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/12-425-L

    authors: Scheffel DL,Hebling J,Scheffel RH,Agee K,Turco G,de Souza Costa CA,Pashley D

    更新日期:2014-03-01 00:00:00

  • In vivo examination of the Scotchbond Multi-Purpose Dental Adhesive System in rat (vitalmicroscopic study).

    abstract::No data are available on the direct acute vascular effect of dental bonding materials on the dental pulp. This study investigated the effects of the components of a composite resin-bonding system on pulpal vascular diameter. Three groups of 10 male Sprague-Dawley rats (weighing 330 +/- 51 g) were used for this investi...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Iványi I,Balogh AE,Rosivall L,Nyárasdy I

    更新日期:2000-09-01 00:00:00

  • Repair of non-carious amalgam margin defects.

    abstract::This study investigated the microleakage associated with the repair of non-carious amalgam defects using flowable resin composite. Occlusal amalgam preparations were accomplished on 36 non-carious mandibular molars. A standardized 40-micron marginal defect was made by condensing amalgam against a mylar matrix strip. S...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Roberts HW,Charlton DG,Murchison DF

    更新日期:2001-05-01 00:00:00

  • Dynamic Viscoelastic Characterization of Bulk-fill Resin-based Composites and Their Conventional Counterparts.

    abstract::This study compared the viscoelastic properties of restorative and flowable bulk-fill resin-based composites (RBCs) with their conventional counterparts and evaluated the impact of aqueous solutions on viscoelastic properties. The materials examined included three conventional RBCs (Filtek Z350, Tetric N Ceram, and Be...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/19-005-L

    authors: Yap AU,Eweis AH,Yahya NA

    更新日期:2020-03-01 00:00:00

  • The microtensile bond strength of Fuji IX glass ionomer cement to antibacterial conditioned dentin.

    abstract:INTRODUCTION:Adding antibacterial agents to a dentin conditioner used for a glass ionomer cement (GIC) has been shown to be antibacterial; however, it is not known whether this antimicrobial conditioning agent affects the bond strength to dentin in situ. This study applied GIC to antibacterial conditioned dentin withou...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Botelho MG

    更新日期:2005-05-01 00:00:00

  • Effect of Simulated Mastication on the Surface Roughness and Wear of Machinable Ceramics and Opposing Dental Enamel.

    abstract:OBJECTIVE::Computer aided design-computer aided machining (CAD-CAM) ceramic crowns are replacing ceramo-metal ones due to newly developed mechanical properties and esthetics. To obtain knowledge about their interactions due to polishing and occlusal contacts with the opposing dental enamel specimen, including surface r...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/17-153-L

    authors: Daryakenari G,Alaghehmand H,Bijani A

    更新日期:2019-01-01 00:00:00

  • In vivo occlusal wear of posterior composite restorations.

    abstract::The available and proposed methods for determining the in vivo occlusal wear values of classes 1 and 2 restorations made of resinfilled composite materials are critically reviewed. A methodology to be used to address the fundamental question of the link between the wear of the in vivo restorations and the relevant mec...

    journal_title:Operative dentistry

    pub_type: 杂志文章,评审

    doi:

    authors: Lewis G

    更新日期:1991-03-01 00:00:00

  • Buonocore Memorial Lecture. Dentin caries: progression and clinical management.

    abstract::A fundamental issue of restorative treatment is assessing the different conditions of cases not only from tooth-to-tooth but also from the activity of each caries lesion and the size of the cavity. In addition, restorative treatment is sometimes carried out for prosthetic and cosmetic purposes and involves cutting sou...

    journal_title:Operative dentistry

    pub_type:

    doi:

    authors: Bjørndal L

    更新日期:2002-05-01 00:00:00

  • Labeled vs actual concentration of bleaching agents.

    abstract::The purpose of this study was to determine if the actual concentration of bleaching agents available in four different countries were the same as the label indicated and within the recommendations of the International Standard on Tooth Whitening. The method recommended for assaying peroxide by the United States Pharma...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/11-367-L

    authors: Matis BA,Matis JI,Wang Y,Monteiro S,Al-Qunaian TA,Millard R

    更新日期:2013-05-01 00:00:00

  • Novel Microscalpels for Removing Proximal Composite Resin Overhangs on Class II Restorations.

    abstract:INTRODUCTION:Limited access to interdental spaces complicates removal of excess material when placing class II composite resin restorations. Evidence-based recommendations on interproximal finishing are rare. We present novel microscalpels for this indication. The aim of the study was to test their fracture strength an...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/16-012-L

    authors: Wolff D,Schick S,Staehle HJ,Frese C

    更新日期:2017-05-01 00:00:00

  • Effect of preheating resin composite and light-curing units on the microleakage of Class II restorations submitted to thermocycling.

    abstract::This in vitro study evaluated microleakage in Class II cavities restored with dental composite and varying light-curing units and the temperature of the composite when subjected to a thermocycling test. Ninety cavities were prepared on the proximal surfaces of bovine teeth and randomly divided according to the light-c...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/10-226-LR1

    authors: dos Santos RE,Lima AF,Soares GP,Ambrosano GM,Marchi GM,Lovadino JR,Aguiar FH

    更新日期:2011-01-01 00:00:00

  • A Conservative Approach to Ceramic Veneers: A Case Report.

    abstract::Bonding to enamel has been shown to provide reliable results, and thus conservative tooth preparations are key to the success of ceramic bonded restorations. The wax-up is the first diagnostic tool available to evaluate discrepancies between current and ideal tooth proportions. The clinician's diagnostic mock-up provi...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/19-051-T

    authors: Jurado C,Watanabe H,Tinoco JV,Valenzuela HU,Perez GG,Tsujimoto A

    更新日期:2020-05-01 00:00:00

  • Efficacy testing of visible-light-curing units.

    abstract::This study evaluated (1) the effect of known reductions in the output of curing lights on the depth of cure of various resins as determined by hardness measurements, and (2) the ability of the clinician to detect reduced light output by use of an explorer to compare the hardness of the top and bottom surfaces of resin...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Fowler CS,Swartz ML,Moore BK

    更新日期:1994-03-01 00:00:00

  • Composite cure and shrinkage associated with high intensity curing light.

    abstract::This study investigated the effectiveness of cure and post-gel shrinkage of three visible light-cured composite resins (In Ten-S [IT], Ivoclar Vivadent; Z100 [ZO], 3M-ESPE; Tetric Ceram [TC], Ivoclar Vivadent) when polymerized with a very high intensity (1296 +/- 2 mW/cm2) halogen light (Astralis 10, Ivoclar Vivadent)...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Yap AU,Wong NY,Siow KS

    更新日期:2003-07-01 00:00:00

  • Effects of secondary curing on indirect posterior composite resins.

    abstract::This study was designed to compare strength, elastic modulus (stiffness), and hardness for five composite resin materials that are used for laboratory-fabricated posterior composite restorations. Ten specimens of each material were processed according to the manufacturer's instructions. Statistical analysis indicated ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Reinhardt JW,Boyer DB,Stephens NH

    更新日期:1994-11-01 00:00:00

  • Analysis of the degree of conversion of LED and halogen lights using micro-Raman spectroscopy.

    abstract::This study determined the degree of conversion of two LED (light-emitting diodes) (Elipar FreeLight [FL], 3M ESPE; GC e-Light [EL], GC), a high intensity (Elipar TriLight [TL], 3M ESPE) and a very high intensity (Astralis 10 [AS], Ivoclar Vivadent) halogen light. The degree of conversion of these lights was compared t...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Soh MS,Yap AU,Yu T,Shen ZX

    更新日期:2004-09-01 00:00:00

  • Degree of conversion and hardness of a silorane-based composite resin: effect of light-curing unit and depth.

    abstract:PURPOSE:To investigate the effect of different light-curing units and depths on the degree of conversion (DC) through Fourier transform infrared spectroscopy (FTIR) and Knoop Hardness Number (KHN) of a silorane-based composite resin (Filtek LS, 3M ESPE, St Paul, MN, USA) (LS). MATERIALS AND METHODS:LS specimens mounte...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/12-479

    authors: Torres SA,Silva GC,Maria DA,Campos WR,Magalhães CS,Moreira AN

    更新日期:2014-05-01 00:00:00