Effect of preheating resin composite and light-curing units on the microleakage of Class II restorations submitted to thermocycling.

Abstract:

:This in vitro study evaluated microleakage in Class II cavities restored with dental composite and varying light-curing units and the temperature of the composite when subjected to a thermocycling test. Ninety cavities were prepared on the proximal surfaces of bovine teeth and randomly divided according to the light-curing mode (QTH-420 mW/cm2, LED 2nd generation-1100 mW/cm2, or LED 3rd generation-700 mW/cm2) and temperature of the resin composite (23°C, 54°C and 60°C). Following the restorative procedures and thermocycling, the samples were immersed in methylene blue for 12 hours. The samples were ground and the powder prepared for analysis in an absorbance spectrophotometer. All the results were statistically analyzed using the nonparametric tests of Kruskal-Wallis and Dunn (p ≤ 0.05). The results showed that there was no statistical difference between the light-curing modes at a temperature of 23°C. For 54°C, QTH showed a microleakage mean that was significantly lower than those of the LED groups, and for 60°C, QTH had a microleakage mean significantly lower than that of the LED 2nd generation group. There was no statistical difference between the temperatures of the resin composite when LEDs were used. For QTH, 54°C showed statistically lower microleakage than 23°C. The group preheated to 60°C showed no difference when compared to the group heated to 23°C. Preheating the resin composite (54°C and 60°C) did not improve the microleakage means when high-irradiance LED was used; however, it decreased the microleakage means when a QTH with low irradiance was used.

journal_name

Oper Dent

journal_title

Operative dentistry

authors

dos Santos RE,Lima AF,Soares GP,Ambrosano GM,Marchi GM,Lovadino JR,Aguiar FH

doi

10.2341/10-226-LR1

subject

Has Abstract

pub_date

2011-01-01 00:00:00

pages

60-5

issue

1

eissn

0361-7734

issn

1559-2863

journal_volume

36

pub_type

杂志文章
  • Effect of dual cure composite as dentin substitute on marginal integrity of class II open-sandwich restorations.

    abstract::The current study compared the marginal adaptation of Class II open-sandwich restorations with a RMGIC versus a dual-cure composite as dentin substitute. Class II cavities were prepared on 50 extracted human third molars. The teeth were randomly assigned to two groups of 25 teeth to compare one dual cure composite (Mu...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/08-29

    authors: Koubi S,Raskin A,Dejou J,About I,Tassery H,Camps J,Proust JP

    更新日期:2009-03-01 00:00:00

  • Buonocore Memorial Lecture. Dentin caries: progression and clinical management.

    abstract::A fundamental issue of restorative treatment is assessing the different conditions of cases not only from tooth-to-tooth but also from the activity of each caries lesion and the size of the cavity. In addition, restorative treatment is sometimes carried out for prosthetic and cosmetic purposes and involves cutting sou...

    journal_title:Operative dentistry

    pub_type:

    doi:

    authors: Bjørndal L

    更新日期:2002-05-01 00:00:00

  • Short-term dentin bridging of mechanically-exposed pulps capped with adhesive resin systems.

    abstract::Dentin bridging of 150 mechanically exposed monkey pulps to two adhesive resins [BondWell LC (BW); Clearfil Liner Bond II (LB)] and a calcium hydroxide cement [Dycal (DY)] were histopathologically evaluated at 3, 7, 14, 30, and 60 days after operation (n = 10). The dentin bridge structure was three-dimensionally recon...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Kitasako Y,Shibata S,Pereira PN,Tagami J

    更新日期:2000-05-01 00:00:00

  • Effect of grooves on resistance form of Class 2 amalgams with wide occlusal preparations.

    abstract::This study evaluated in vitro the necessity of retention grooves in approximal boxes in class 2 preparations with faciolingually wide occlusal extensions (occlusal isthmus width 1.8 mm). Thirty-six class 2 mesio-occlusal cavities were prepared in sound human maxillary premolar teeth and divided into three groups of 12...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Summitt JB,Osborne JW,Burgess JO,Howell ML

    更新日期:1993-03-01 00:00:00

  • Cumulative assessment of factors leading to restorative decisions in an educational environment. A graphical demonstration using an in vitro case.

    abstract::Even though accuracy and inter-examiner variation assessments of borderline restorative items have been previously reported, no attempt has been made to replicate the effect of cumulative, sequential diagnostic and treatment planning decisions. This study assesses the cumulative effect of factors indicating restorativ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Maupomé G

    更新日期:2000-07-01 00:00:00

  • Bond strength of glass ionomers to coronal and radicular dentin.

    abstract::A study was conducted to compare the shear bond strength of a glass-ionomer cement and glass-ionomer base to coronal and radicular dentin. Two different glass ionomers were bonded to paired coronal and radicular human dentin surfaces that had received no surface treatment or had been treated passively for 20 seconds w...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Berry EA 3rd,Powers JM

    更新日期:1994-07-01 00:00:00

  • Effect of Minocycline on the Durability of Dentin Bonding Produced with Etch-and-Rinse Adhesives.

    abstract:OBJECTIVES:To evaluate the effect of minocycline and chlorhexidine pretreatment of acid-etched dentin on the longevity of resin-dentin bond strength (μTBS) and nanoleakage of two-step etch-and-rinse adhesives. METHODS:Before application of Prime & Bond NT and Adper Single Bond 2 in occlusal dentin, the dentin surfaces...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/15-023-L

    authors: Loguercio AD,Stanislawczuk R,Malaquias P,Gutierrez MF,Bauer J,Reis A

    更新日期:2016-09-01 00:00:00

  • Degree of conversion and hardness of a silorane-based composite resin: effect of light-curing unit and depth.

    abstract:PURPOSE:To investigate the effect of different light-curing units and depths on the degree of conversion (DC) through Fourier transform infrared spectroscopy (FTIR) and Knoop Hardness Number (KHN) of a silorane-based composite resin (Filtek LS, 3M ESPE, St Paul, MN, USA) (LS). MATERIALS AND METHODS:LS specimens mounte...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/12-479

    authors: Torres SA,Silva GC,Maria DA,Campos WR,Magalhães CS,Moreira AN

    更新日期:2014-05-01 00:00:00

  • Impact of Silane-containing Universal Adhesive on the Biaxial Flexural Strength of a Resin Cement/Glass-ceramic System.

    abstract::The aim of this study was to determine whether using a silane-containing universal adhesive as a silane primer in glass-ceramic/resin cement systems affects biaxial flexural strength (BFS) and bonded interface integrity after loading. Glass-ceramic (IPS e.max CAD, Ivoclar/Vivadent, Schaan, Liechtenstein) disc-shaped s...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/17-356-L

    authors: Murillo-Gómez F,Wanderley RB,De Goes MF

    更新日期:2019-03-01 00:00:00

  • Labeled vs actual concentration of bleaching agents.

    abstract::The purpose of this study was to determine if the actual concentration of bleaching agents available in four different countries were the same as the label indicated and within the recommendations of the International Standard on Tooth Whitening. The method recommended for assaying peroxide by the United States Pharma...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/11-367-L

    authors: Matis BA,Matis JI,Wang Y,Monteiro S,Al-Qunaian TA,Millard R

    更新日期:2013-05-01 00:00:00

  • Influence of curing methods and matrix type on the marginal seal of class II resin-based composite restorations in vitro.

    abstract::This study determined the influence of light curing protocols and matrix type on the margin quality and marginal seal of Class II resin-based composite restorations. In extracted human molars, box-shaped MOD cavities with 1 mm wide interproximal bevels were prepared with cervical margins located at least 1 mm coronal ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/04-194

    authors: Hofmann N,Hunecke A

    更新日期:2006-01-01 00:00:00

  • Dynamic Viscoelastic Characterization of Bulk-fill Resin-based Composites and Their Conventional Counterparts.

    abstract::This study compared the viscoelastic properties of restorative and flowable bulk-fill resin-based composites (RBCs) with their conventional counterparts and evaluated the impact of aqueous solutions on viscoelastic properties. The materials examined included three conventional RBCs (Filtek Z350, Tetric N Ceram, and Be...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/19-005-L

    authors: Yap AU,Eweis AH,Yahya NA

    更新日期:2020-03-01 00:00:00

  • Cuspal Deflection in Premolar Teeth Restored with Bulk-Fill Resin-Based Composite Materials.

    abstract::The present study investigated the effect of three high-viscosity bulk-fill resin-based composite materials on cuspal deflection in natural teeth. Thirty-two sound maxillary premolar teeth with large slot mesio-occlusal-distal cavities were distributed into four groups (n=8). Three groups were restored with bulk-fill ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/16-072-L

    authors: Elsharkasi MM,Platt JA,Cook NB,Yassen GH,Matis BA

    更新日期:2018-01-01 00:00:00

  • Online Only Articles.

    abstract::On occasion we receive manuscripts that we would like to publish, but do not have the page room to include in the print journal. For the full article, please go to www.jopdentonline.org or enter the provided address into your address bar. ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/1559-2863-43.3.335

    authors:

    更新日期:2018-05-01 00:00:00

  • Enamel bond strengths of pairs of adhesives from the same manufacturer.

    abstract::Most manufacturers of dental adhesives have both a total-etch adhesive and a simplified self-etching adhesive available on the market. This study measured the enamel microtensile bond strengths of five pairs of enamel adhesives as a function of enamel roughness. The proximal surfaces of 25 extracted mandibular molars ...

    journal_title:Operative dentistry

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:

    authors: Perdigão J,Gomes G,Duarte S Jr,Lopes MM

    更新日期:2005-07-01 00:00:00

  • Influence of Thermal Cycling on Flexural Properties and Simulated Wear of Computer-aided Design/Computer-aided Manufacturing Resin Composites.

    abstract:OBJECTIVE:The purpose of this study was to evaluate the influence of thermal cycling on the flexural properties and simulated wear of computer-aided design/computer-aided manufacturing (CAD/CAM) resin composites. METHODS:The six CAD/CAM resin composites used in this study were 1) Lava Ultimate CAD/CAM Restorative (LU)...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/16-046-L

    authors: Tsujimoto A,Barkmeier WW,Takamizawa T,Latta MA,Miyazaki M

    更新日期:2017-01-01 00:00:00

  • A clinical study on interdental separation techniques.

    abstract::The effect of interdental separation of a special separation ring and wooden wedge was investigated. In a split-mouth design, 27 patients were randomly assigned to one of two groups (W or S). In 11 patients, an interdental wooden wedge (Hawe-Neos) was placed (group W), and in 16 patients, a separation ring (Composi-Ti...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/06-73

    authors: Loomans BA,Opdam NJ,Bronkhorst EM,Roeters FJ,Dörfer CE

    更新日期:2007-05-01 00:00:00

  • Combination of Acetaminophen/Codeine Analgesics Does Not Avoid Bleaching-Induced Tooth Sensitivity: A Randomized, Triple-Blind Two-Center Clinical Trial.

    abstract::Bleaching-induced tooth sensitivity (TS) is highly prevalent. OBJECTIVE:This study aimed to determine if the combination of opioids and nonopioids analgesics (Tylex) may provide a better analgesic effect. METHOD:A triple-blind, parallel, randomized two-center clinical trial was conducted with 105 healthy patients wh...

    journal_title:Operative dentistry

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.2341/17-092-C

    authors: Coppla FM,Rezende M,de Paula E,Farago PV,Loguercio AD,Kossatz S,Reis A

    更新日期:2018-03-01 00:00:00

  • Longevity of low- and high-copper amalgams analyzed by preparation class, tooth site, patient age, and operator.

    abstract::The purpose of this study was to compare the long-term survivals of two low-copper and three high-copper amalgam alloys, and to analyze four clinical factors for their possible effects on the restoration survivals. Some 1476 polished restorations were placed in hospital patients by a large number of operators and asse...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Smales RJ

    更新日期:1991-09-01 00:00:00

  • Influence of Conditioning Time of Universal Adhesives on Adhesive Properties and Enamel-Etching Pattern.

    abstract:OBJECTIVES:To evaluate the effect of application protocol in resin-enamel microshear bond strength (μSBS), in situ degree of conversion, and etching pattern of three universal adhesive systems. METHODS AND MATERIALS:Sixty-three extracted third molars were sectioned in four parts (buccal, lingual, and proximals) and di...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/15-213-L

    authors: Cardenas AM,Siqueira F,Rocha J,Szesz AL,Anwar M,El-Askary F,Reis A,Loguercio A

    更新日期:2016-09-01 00:00:00

  • Microtensile Bond Strength of Composite Cement to Novel CAD/CAM Materials as a Function of Surface Treatment and Aging.

    abstract:OBJECTIVES:To evaluate the effect of different surface treatments on the bond strength to a composite and a polymer-infiltrated ceramic CAD/CAM block after six-month artificial aging. METHODS AND MATERIALS:Two types of CAD/CAM blocks (Cerasmart, GC; Enamic, Vita Zahnfabrik) were cut in slabs of 4-mm thickness, divided...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/15-263-L

    authors: Lise DP,Van Ende A,De Munck J,Vieira L,Baratieri LN,Van Meerbeek B

    更新日期:2017-01-01 00:00:00

  • Fluoride release from fluoride-containing materials.

    abstract::This in vitro study evaluated the amount of fluoride released from fluoride-containing materials over a period of 28 days. Six disk samples (2.06 +/- 0.06 cm2) were prepared of each material and divided at random into seven groups: Group 1: Chelon-Fil; Group 2: Chelon-Silver; Group 3: VariGlass; Group 4: Dyract; Group...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: de Araujo FB,García-Godoy F,Cury JA,Conceição EN

    更新日期:1996-09-01 00:00:00

  • An In Vitro Investigation of Anticaries Efficacy of Fluoride Varnishes.

    abstract::Most currently marketed fluoride varnishes (FVs) have not been evaluated for their effectiveness in preventing dental caries. The objective of this study was to investigate the anticaries efficacy, measured as fluoride release into artificial saliva (AS); change in surface microhardness of early enamel caries lesions;...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/18-040-L

    authors: Dehailan LA,Martinez-Mier EA,Eckert GJ,Lippert F

    更新日期:2019-09-01 00:00:00

  • Accuracy of ceramic restorations made using an in-office optical scanning technique: an in vitro study.

    abstract::The present in vitro study concerns determination of the pre-cementation gap width of all-ceramic crowns made using an in-office digital-impression technique and subsequent computer-aided design/computer-aided manufacturing (CAD/CAM) production. Two chairside video camera systems were used: the Lava Oral scanner and C...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/12-309-L

    authors: Tidehag P,Ottosson K,Sjögren G

    更新日期:2014-05-01 00:00:00

  • Effect of flexural load cycling on microleakage of extended root caries restorations.

    abstract::This study evaluated the microleakage of resin-modified glass ionomer, flowable compomer and flowable resin composite restorations on a Class V cavity of simulated advanced root caries under a flexural load cycling condition. Thirty-six non-carious human maxillary premolars were mounted in cylindrical acrylic resin mo...

    journal_title:Operative dentistry

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:

    authors: Minakuchi S,Munoz CA,Jessop N

    更新日期:2005-03-01 00:00:00

  • Multidisciplinary approach in the rehabilitation of missing lateral incisors: a new trend in daily practice.

    abstract::This article reports the case of a patient with bilateral hypodontia of the maxillary lateral incisors who was dissatisfied with the outcome of initial orthodontic treatment, highlighting the importance of a multidisciplinary interaction among Restorative Dentistry, Orthodontics, and Implantology to achieve satisfacto...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/11-167-T

    authors: Closs LQ,Reston EG,Tessarollo F,Freitas MP,Broliato G

    更新日期:2012-09-01 00:00:00

  • Antibacterial activity of dentin bonding systems, resin-modified glass ionomers, and polyacid-modified composite resins.

    abstract::The antibacterial effects of the dentin bonding systems Syntac, ProBOND, Gluma 3-Step, the resin-modified glass ionomers Photac-Fil, Fuji Lining LC, Fuji II LC, and the polyacid-modified composite resins VariGlass, Geristore, and Infinity were evaluated using the cariogenic bacteria S mutans, L salivarius, S sobrinus,...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Meiers JC,Miller GA

    更新日期:1996-11-01 00:00:00

  • Technique on restoring sub-gingival cervical lesion.

    abstract::This article outlines an atraumatic isolation approach and a conservative instrumentation sequence, followed by use of a highly viscous, rapid-setting, capsulated glass ionomer cement to manage a difficult deep proximal-cervical Class V lesion. ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Chan DC,Adkins J

    更新日期:2004-05-01 00:00:00

  • Rx for caries prevention: time line for home care. A software aid for communication of patient instructions for management of dental caries.

    abstract::Treatment of a caries active patient requires the clinician to be knowledgeable in the restorative and risk management issues with which these patients often present. Modifications of risk factors that promote dental caries play an important part in the long-term restorative success in these patients. Patient complian...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Newitter DA,Meiers JC,Kazemi RB

    更新日期:2002-03-01 00:00:00

  • Effect of bleaching on fracture toughness of resin composites.

    abstract::This study determined the effect of bleaching agents on the fracture toughness of composite materials. Four nanofilled resin composites were evaluated: Filtek Supreme Plus, Tetric EvoCeram, Premise and Esthet-X. Four concentrations of bleaching agents were tested: Opalescence PF 10%, 20%, 35% and 45%. Fifty specimens ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/08-120-L

    authors: Cho SD,Bulpakdi P,Matis BA,Platt JA

    更新日期:2009-11-01 00:00:00