Abstract:
:This study evaluated in vitro the necessity of retention grooves in approximal boxes in class 2 preparations with faciolingually wide occlusal extensions (occlusal isthmus width 1.8 mm). Thirty-six class 2 mesio-occlusal cavities were prepared in sound human maxillary premolar teeth and divided into three groups of 12. In one group, the preparations had no retention grooves. In another group, retention grooves 0.3-0.5 mm deep were prepared at the axioproximal line angles and extended from the gingival floor occlusally to just gingival to the occlusal dentinoenamel junction. In the third group, a 1 mm-long groove was prepared extending from the axiopulpal line angle occlusally to just gingival to the occlusal dentinoenamel junction. The marginal ridges of the amalgam were loaded at an angle of 13.5 degrees from vertical in an Instron Testing Machine until the restorations failed. Results indicated no significant difference in load to cause failure in any of the three groups. Restorations without approximal retention grooves possessed as much resistance to failure as those with grooves.
journal_name
Oper Dentjournal_title
Operative dentistryauthors
Summitt JB,Osborne JW,Burgess JO,Howell MLsubject
Has Abstractpub_date
1993-03-01 00:00:00pages
42-7issue
2eissn
0361-7734issn
1559-2863journal_volume
18pub_type
杂志文章abstract::Dentin bridging of 150 mechanically exposed monkey pulps to two adhesive resins [BondWell LC (BW); Clearfil Liner Bond II (LB)] and a calcium hydroxide cement [Dycal (DY)] were histopathologically evaluated at 3, 7, 14, 30, and 60 days after operation (n = 10). The dentin bridge structure was three-dimensionally recon...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2000-05-01 00:00:00
abstract::A core foundation system is frequently used in endodontically treated teeth that suffer excessive loss of the coronal portion of their structure. The volumetric shrinkage of core foundation resins may create marginal gaps that influence the bonding ability and longevity of a restored tooth. Little is known about how a...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2005-09-01 00:00:00
abstract:OBJECTIVE:To study the interfacial ultra-morphology formed by "all-in-one" self-etch adhesives. METHODS:Forty-nine extracted molars were assigned to one of five all-in-one adhesives: Adper Prompt L-Pop (AP, 3M ESPE); Clearfil S3 Bond (S3, Kuraray); G-Bond (GB, GC America); iBond (iB, Heraeus Kulzer) and Xeno IV (XE, D...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/07-133
更新日期:2008-09-01 00:00:00
abstract::The current study compared the marginal adaptation of Class II open-sandwich restorations with a RMGIC versus a dual-cure composite as dentin substitute. Class II cavities were prepared on 50 extracted human third molars. The teeth were randomly assigned to two groups of 25 teeth to compare one dual cure composite (Mu...
journal_title:Operative dentistry
pub_type: 杂志文章,随机对照试验
doi:10.2341/08-29
更新日期:2009-03-01 00:00:00
abstract:OBJECTIVES:To evaluate the bond strength of adhesive luting agents applied to caries-affected dentin (CAD). METHODS:Thirty-six noncarious human third molars were abraded to expose an occlusal dentin surface. Caries lesions were induced in half of the samples using a microcosm biofilm model. Biofilm was cultivated unde...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/14-169-L
更新日期:2015-05-01 00:00:00
abstract::This in vitro study assessed the effect of a step-cure light curing method on resin/dentin bond strength on the buccal wall of Class I cavities in human teeth. Occlusal enamel was removed to expose a flat dentin surface. Twenty four box-shaped cavities (C-factor = 4.5) were prepared in dentin. Prime&Bond 2.1 was appli...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/05-37
更新日期:2006-05-01 00:00:00
abstract::This study evaluated the effect of different chairside polishing systems on the surface roughness and topography of monolithic zirconia. Thirty-five monolithic zirconia specimens (Lava PLUS, 3M ESPE) were fabricated and divided into five groups of seven and polished with the following: Group 1 (WZ)-Dura white stone fo...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/15-064-L
更新日期:2016-07-01 00:00:00
abstract:OBJECTIVES:To evaluate the effect of minocycline and chlorhexidine pretreatment of acid-etched dentin on the longevity of resin-dentin bond strength (μTBS) and nanoleakage of two-step etch-and-rinse adhesives. METHODS:Before application of Prime & Bond NT and Adper Single Bond 2 in occlusal dentin, the dentin surfaces...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/15-023-L
更新日期:2016-09-01 00:00:00
abstract::This in vitro study evaluated microleakage in Class II cavities restored with dental composite and varying light-curing units and the temperature of the composite when subjected to a thermocycling test. Ninety cavities were prepared on the proximal surfaces of bovine teeth and randomly divided according to the light-c...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/10-226-LR1
更新日期:2011-01-01 00:00:00
abstract:OBJECTIVE:This study evaluated the differences in enamel color change, surface hardness, elastic modulus, and surface roughness between treatments with four bleaching gels containing carbamide peroxide (two at 10% and one each at 35%, and 45%) and two bleaching gels containing hydrogen peroxide (two at 40%). METHODS:E...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/15-010-L
更新日期:2016-01-01 00:00:00
abstract::Ceramic root-canal posts offer potential advantages over other types with respect to aesthetics and biocompatibility. Any post must be sufficiently rigid and retentive to withstand functional forces. Ceraposts (1.2 mm coronal diameter, ceramic, tapering, smooth posts) and Paraposts (1.25 mm, stainless-steel, parallel,...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2000-05-01 00:00:00
abstract:OBJECTIVE:The aim of this study was to compare the in vivo diagnostic ability of a laser fluorescence system (DIAGNOdent, KaVo, Biberac, Germany) with that of visual inspection in the early detection of occlusal caries in newly erupted noncavitated first permanent molars among caries-active children. MATERIALS AND MET...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/10-309-C
更新日期:2011-07-01 00:00:00
abstract:OBJECTIVE:This clinical study aimed to assess the efficacies of mineral trioxide aggregate (MTA) and calcium hydroxide [Ca(OH)2] in the treatment of deep carious lesions by the direct complete caries removal technique. METHODS AND MATERIALS:A total of 100 permanent molar/premolar teeth were capped with either Ca(OH)2 ...
journal_title:Operative dentistry
pub_type: 杂志文章,随机对照试验
doi:10.2341/16-110-C
更新日期:2017-09-01 00:00:00
abstract::The bulk-filling of deep, wide dental cavities is faster and easier than traditional incremental restoration. However, the extent of cure at the bottom of the restoration should be carefully examined in combination with the polymerization contraction and gap formation that occur during the restorative procedure. The a...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/13-324-L
更新日期:2015-03-01 00:00:00
abstract::To protect glass-ionomer cement from moisture contamination and dehydration during initial setting, immediate application of a surface coating agent is recommended. This study compared the effect of various surface coatings on F release from glass-ionomer cement. Twenty glass-ionomer cement (Ketac Fil Aplicap) disks (...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1994-09-01 00:00:00
abstract::The molar proximal half-crown cast gold restoration may be an ideal choice for the conservative treatment of teeth with only one compromised proximal aspect. ...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/10-T1
更新日期:2010-03-01 00:00:00
abstract::This in-vitro study compared the resistance of extensive amalgam restorations retained by either four Regular TMS Link Plus pins, four amalgapins, Amalgambond Plus, Amalgambond Plus with HPA, Scotchbond Multi-Purpose Plus, PQ Amalgam, Panavia F 2.0, All-Bond 2 or Resinomer. Ninety caries-free third molars were embedde...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/08-5
更新日期:2008-11-01 00:00:00
abstract::This study investigated the influence of light energy density (intensity x time) on the effectiveness of composite cure in view of the curing profiles of new light-polymerization units. This investigation used a digital microhardness tester to evaluate the hardness of the top/bottom surfaces and hardness ratio of 2 mm...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2001-09-01 00:00:00
abstract:PURPOSE:To investigate the influence of ferrule thickness on fracture resistance after mechanical cycling of teeth restored with different intracanal posts. METHODS AND MATERIALS:One hundred twenty bovine incisor teeth were randomized into six study groups, based on the intracanal post used (fiber post or cast post an...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/18-241-L
更新日期:2019-11-01 00:00:00
abstract::This study investigated the reasons for placement and replacement of dental restorations in the United States Navy Dental Corps. The relationship between restoration longevity and the reasons for replacement of restorations was also studied. Data on newly placed dental restorations were collected from restorative dent...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1993-09-01 00:00:00
abstract::No data are available on the direct acute vascular effect of dental bonding materials on the dental pulp. This study investigated the effects of the components of a composite resin-bonding system on pulpal vascular diameter. Three groups of 10 male Sprague-Dawley rats (weighing 330 +/- 51 g) were used for this investi...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2000-09-01 00:00:00
abstract::A fundamental issue of restorative treatment is assessing the different conditions of cases not only from tooth-to-tooth but also from the activity of each caries lesion and the size of the cavity. In addition, restorative treatment is sometimes carried out for prosthetic and cosmetic purposes and involves cutting sou...
journal_title:Operative dentistry
pub_type:
doi:
更新日期:2002-05-01 00:00:00
abstract:OBJECTIVES:Inadequately polymerized resin cements may negatively affect the clinical performance of cemented all-ceramic restorations. The purpose of this in vitro study was to evaluate the effect of ceramic thickness and shade on the microhardness of various light-cured (LC) and dual-cured (DC) resin cements. The amou...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/10-206-L
更新日期:2011-11-01 00:00:00
abstract::Coronal fractures of posterior teeth are not rare in clinical practice. Most of the time they constitute a restorational problem for the clinician, since they usually end below the free gingival crest. Two hundred coronal fractures of posterior teeth were examined in this study, with respect to several factors. Some o...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1989-01-01 00:00:00
abstract::The available and proposed methods for determining the in vivo occlusal wear values of classes 1 and 2 restorations made of resinfilled composite materials are critically reviewed. A methodology to be used to address the fundamental question of the link between the wear of the in vivo restorations and the relevant mec...
journal_title:Operative dentistry
pub_type: 杂志文章,评审
doi:
更新日期:1991-03-01 00:00:00
abstract:OBJECTIVES:People increasingly desire tooth whitening. Considering the wide range of whitening products on the market, this study evaluated the efficacy of whitening toothpastes and mouth rinses compared with the 10% carbamide peroxide (CP) whitening gel. METHODS:We obtained 120 cylindrical specimens from bovine teeth...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/11-360-L
更新日期:2013-01-01 00:00:00
abstract::Different approaches have been proposed to improve the adaptation of Class II restorations, including applying low-elasticity modulus base liners. This in vitro fatigue test (or study) evaluated the influence of the compomer base-lining configuration on restoration adaptation. Direct Class II MOD box-shaped composite ...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2002-09-01 00:00:00
abstract::This study evaluated the effects of acid etching of the enamel and the combination of different light sources (halogen light, light-emitting diodes [LEDs], and LED/Laser) and the bleaching product on color change, penetration of hydrogen peroxide (H2O2), and cytotoxicity over time. The color change (ΔE) and the amount...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/14-364-L
更新日期:2016-01-01 00:00:00
abstract::Recently, manufacturers introduced presterilized, single-use, plastic light-curing tips to be used either routinely or on patients with known or questionable communicable health concerns. The purpose of this study was to examine the effect of these single-use tips on light transmission compared to conventional fiber-o...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1998-07-01 00:00:00
abstract::The stronger the ceramic material, the longer the restoration stays in the mouth. The current study evaluated the two-year clinical performance of a strong ceramic system, IPS Empress II, with increased strength on onlay/inlay restorations of molars. Teeth from 35 patients, including three premolars and 32 molars, wer...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/08-97
更新日期:2009-07-01 00:00:00