Abstract:
:The present study investigated the effect of three high-viscosity bulk-fill resin-based composite materials on cuspal deflection in natural teeth. Thirty-two sound maxillary premolar teeth with large slot mesio-occlusal-distal cavities were distributed into four groups (n=8). Three groups were restored with bulk-fill resin composite materials (Tetric EvoCeram Bulk Fill, Ivoclar Vivadent, Schaan, Liechtenstein; x-tra fil, VOCO, Cuxhaven, Germany; and SonicFill, Kerr, Orange, CA, USA) in a single 4-mm increment. The conventional composite group, Filtek Z100 (3M ESPE, St Paul, MN, USA), was used to restore the cavities in 2-mm increments. Cusp deflection was recorded postirradiation using a Nikon measurescope UM-2 (Nikon, Tokyo, Japan) by measuring the changes in the bucco-palatal widths of the teeth at five minutes, 24 hours, and 48 hours after completion of the restorations. Cuspal deflection was significantly higher in the conventional composite than in the Tetric EvoCeram Bulk Fill ( p=0.0031), x-tra fil ( p=0.0029), and SonicFill Bulk ( p=0.0002) groups. There were no significant differences in cuspal deflection among the three bulk-fill materials (all p<0.05). In conclusion, all the investigated bulk-fill resin composites exhibited cuspal deflection values that were smaller than those associated with a conventional incrementally placed resin composite.
journal_name
Oper Dentjournal_title
Operative dentistryauthors
Elsharkasi MM,Platt JA,Cook NB,Yassen GH,Matis BAdoi
10.2341/16-072-Lsubject
Has Abstractpub_date
2018-01-01 00:00:00pages
E1-E9issue
1eissn
0361-7734issn
1559-2863journal_volume
43pub_type
杂志文章abstract::The clinical performance of light curing resin composites is greatly influenced by the quality of the light-curing unit (LCU). Halogen LCUs are commonly used for curing composite materials. However, they have some drawbacks. The development of new, blue, super bright light emitting diodes (LED LCU) of 470-nm wavelengt...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2005-01-01 00:00:00
abstract::SUMMARY The purpose of this study was to evaluate the influence the width of the occlusal isthmus and inlay material had on the stress distribution, displacement, and fracture resistance of upper human premolars. For this in vitro test, 35 intact upper premolars (UPM) were selected and five were kept intact for the co...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/13-092-L
更新日期:2014-07-01 00:00:00
abstract::This study investigated the influence of curing lights and modes on the cross-link density of dental composites. Four LED/halogen curing lights (LED-Elipar Freelight [FL], 3M-ESPE and GC e-light [EL], GC; high intensity halogen-Elipar Trilight [TL], 3M-ESPE; very high intensity halogen-Astralis 10 [AS], Ivoclar Vivade...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2004-07-01 00:00:00
abstract::Minimally invasive flowable composite Class I restorations are widely used. However, flowable composites are characterized by low filler contents, modified resin formulations, low moduli of elasticity, low viscosity, generally poor mechanical properties, and decreased long-term stability. The purpose of this study was...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/11-106-L
更新日期:2012-05-01 00:00:00
abstract::This in vitro study assessed the effect of a step-cure light curing method on resin/dentin bond strength on the buccal wall of Class I cavities in human teeth. Occlusal enamel was removed to expose a flat dentin surface. Twenty four box-shaped cavities (C-factor = 4.5) were prepared in dentin. Prime&Bond 2.1 was appli...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/05-37
更新日期:2006-05-01 00:00:00
abstract::This study evaluated the effects of acid etching of the enamel and the combination of different light sources (halogen light, light-emitting diodes [LEDs], and LED/Laser) and the bleaching product on color change, penetration of hydrogen peroxide (H2O2), and cytotoxicity over time. The color change (ΔE) and the amount...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/14-364-L
更新日期:2016-01-01 00:00:00
abstract::Detailed and accurate impressions are made when the oral environment is dry during the impression process. Maintaining a dry field on medically, physically, or emotionally compromised patients can be very challenging. If not achieved, it may compromise dental care and accurate outcomes. This article describes a techni...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/11-290-T
更新日期:2014-01-01 00:00:00
abstract::Veneers were fabricated by CEREC CAD-CAM and the platinum foil techniques for standardized preparations on 10 artificial teeth. Mesial preparation contacts were broken, but distal contacts remained intact. The veneers were cemented in a standardized manner to their teeth. The veneers and their attached cement were emb...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1997-05-01 00:00:00
abstract:CLINICAL RELEVANCE:Pigments in tooth structures affect the diffusion of H2O2 through enamel and dentin. The bleaching methodology can be impacted. SUMMARY:Objective: The aim of this study was to evaluate the influence of the presence of pigments in tooth structures on the trans-enamel and trans-dentin diffusion of hyd...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/19-013-L
更新日期:2020-11-01 00:00:00
abstract:CLINICAL RELEVANCE:Computer-aided design/computer-aided manufacturing (CAD/CAM) composite resins are susceptible to degradation by dietary solvents. Dietary counselling is prudent when placing such CAD/CAM restorations. SUMMARY:This study determined the effect of dietary solvents on the surface roughness (Ra) of direc...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/19-070-L
更新日期:2020-07-01 00:00:00
abstract::Traumatic dental injuries usually occur among children and adolescents, with maxillary central incisors as the most often affected teeth. Complicated crown-root fractures are particularly challenging for esthetic and functional rehabilitation and often require a multidisciplinary approach. A 21-year-old male patient c...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/15-080-T
更新日期:2016-11-01 00:00:00
abstract::A study was conducted to compare the shear bond strength of a glass-ionomer cement and glass-ionomer base to coronal and radicular dentin. Two different glass ionomers were bonded to paired coronal and radicular human dentin surfaces that had received no surface treatment or had been treated passively for 20 seconds w...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1994-07-01 00:00:00
abstract::A literature review was conducted on adhesive Class I and II restorations and nondestructive in vitro tests using the PubMed/Medline database for the 1995-2010 period. The first part of this review has presented and critically appraised selected literature dealing with the quality and in vitro behavior of adhesive Cla...
journal_title:Operative dentistry
pub_type: 杂志文章,评审
doi:10.2341/12-020B-LIT
更新日期:2013-09-01 00:00:00
abstract:OBJECTIVE:The aim of this study was to compare the in vivo diagnostic ability of a laser fluorescence system (DIAGNOdent, KaVo, Biberac, Germany) with that of visual inspection in the early detection of occlusal caries in newly erupted noncavitated first permanent molars among caries-active children. MATERIALS AND MET...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/10-309-C
更新日期:2011-07-01 00:00:00
abstract::The effect of microabrasion on human enamel has been well documented; however, no information is available on its effect on dentin or restorative materials. The purpose of this study was to evaluate the effect of the microabrasion technique on the surface roughness of restorative materials and enamel and dentin surfac...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1996-03-01 00:00:00
abstract::Most manufacturers of dental adhesives have both a total-etch adhesive and a simplified self-etching adhesive available on the market. This study measured the enamel microtensile bond strengths of five pairs of enamel adhesives as a function of enamel roughness. The proximal surfaces of 25 extracted mandibular molars ...
journal_title:Operative dentistry
pub_type: 临床试验,杂志文章,随机对照试验
doi:
更新日期:2005-07-01 00:00:00
abstract::The antibacterial properties of self-etching adhesive systems constitute an important issue in operative dentistry, since viable bacteria can still be present after cavity preparation. The current study evaluated the antibacterial activity of five one-step self-etching adhesives (SEAs) and four self-etching primers (S...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/09-297-L
更新日期:2010-07-01 00:00:00
abstract::Amalgapins are susceptible to early fracture during matrix removal and carving. The purpose of this study was to examine the early fracture resistance of amalgapin-retained restorations using a spherical amalgam alloy, an admixed amalgam alloy, a combination of admixed alloy over the spherical alloy, and a recently in...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1998-03-01 00:00:00
abstract::To evaluate the correlation between microtensile dentin bond strength (microTBS) and silver ion penetration, two total-etch 3-step and one self-etch 2-step system were investigated. OptiBond FL adhesive was applied to flat occlusal dentin on six non-carious human molars, and a resin composite "crown" was formed in 2 m...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2003-01-01 00:00:00
abstract::This review compares nine published studies conducted at the Indiana University School of Dentistry. Twenty-five products in four different systems were evaluated using the Trubyte Bioform Color Ordered Shade Guide and a Chroma Meter. The dentist-prescribed overnight bleaching delta mean shade guide value (DSGV) 10 we...
journal_title:Operative dentistry
pub_type: 杂志文章,评审
doi:10.2341/08-74
更新日期:2009-03-01 00:00:00
abstract::Four resin based materials (Compolute Aplicap, ESPE; Variolink Ultra, Vivadent; C&B Metabond, Parkell and Panavia 21, Kuraray), two carboxylate cements (Poly-F Plus, Dentsply DeTrey and Durelon Maxicap, ESPE), two glass-ionomer cements (Fuji I, GC and Ketac-Cem Aplicap, ESPE), one resin-modified glass ionomer cement (...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2000-11-01 00:00:00
abstract::The reasons for placement and replacement and the longevity of amalgam restorations were recorded by 62 Italian private practitioners. The survey compiled 1935 amalgam restorations inserted due to primary caries (59%) and failed restorations (41%). The clinical diagnosis of secondary caries constituted 59% of failures...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1992-03-01 00:00:00
abstract::The current study compared the marginal adaptation of Class II open-sandwich restorations with a RMGIC versus a dual-cure composite as dentin substitute. Class II cavities were prepared on 50 extracted human third molars. The teeth were randomly assigned to two groups of 25 teeth to compare one dual cure composite (Mu...
journal_title:Operative dentistry
pub_type: 杂志文章,随机对照试验
doi:10.2341/08-29
更新日期:2009-03-01 00:00:00
abstract:OBJECTIVES:To evaluate the beam profile and the spectral output of monowave and polywave light-emitting diodes (LEDs) and their influence on the degree of conversion (DC) of bulk fill composites. METHODS:A monowave LED (Smartlite Focus, Dentsply) and a polywave LED (Valo Cordless, Ultradent) were characterized using a...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/16-164-L
更新日期:2017-07-01 00:00:00
abstract:PURPOSE:This study evaluated the effect of thermocycling on the microtensile bond strength of four adhesive luting agents to GN-I CAD-CAM ceramic. The hypothesis tested was that thermocycling did not affect bonding effectiveness, irrespective of the luting agents used. MATERIALS AND METHODS:Ceramic specimens of two di...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:10.2341/06-106
更新日期:2007-07-01 00:00:00
abstract::This study investigated the effects of an at-home bleaching gel containing 15% carbamide peroxide on the susceptibility of tooth-colored restorative materials to different staining solutions. The tooth-colored restoratives used in this study were a nano resin composite (Filtek Z350), a packable resin composite (Filtek...
journal_title:Operative dentistry
pub_type: 杂志文章,随机对照试验
doi:10.2341/08-42
更新日期:2009-01-01 00:00:00
abstract::This in vitro study investigated the effects of a thin layer of flowable composite or compomer on microleakage occurring in Class II packable and nanofilled composite restorations that extend apical to the cemento-enamel junction (CEJ). The current study also investigated any differences in microleakage that occur bet...
journal_title:Operative dentistry
pub_type: 杂志文章,随机对照试验
doi:10.2341/08-91
更新日期:2009-05-01 00:00:00
abstract:OBJECTIVES:This study aimed to assess the retention of metal copings luted to uremic teeth with five different luting agents. METHODS:A total of 35 sound natural molars was collected from uremic patients and randomly assigned into five groups (n=7). The teeth were prepared for metal copings using diamond tips and wate...
journal_title:Operative dentistry
pub_type: 杂志文章,随机对照试验
doi:10.2341/12-523-LR2
更新日期:2014-05-01 00:00:00
abstract::This study examined the relationship between the bond agent application duration and the dentin bond strength of several single-application bonding systems. The restorative material/ bonding systems used were Reactmer, with its single-application bonding system Reactmer Bond (RB, Shofu Inc, Kyoto, Japan); Palfique Est...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:2002-05-01 00:00:00
abstract::V-shaped cervical cavities prepared in monkey teeth were restored with several dentin bonding systems, and the in vivo resin-dentin interfacial structures were observed under the scanning electron microscope using an argon-ion etching technique. The hybrid layer could be clearly observed; its depth was dependent on th...
journal_title:Operative dentistry
pub_type: 杂志文章
doi:
更新日期:1995-09-01 00:00:00