Repair of dimethacrylate-based composite restorations by a silorane-based composite: a one-year randomized clinical trial.

Abstract:

PURPOSE:To investigate clinical performance of a low-shrinkage silorane-based composite resin when used for repairing conventional dimethacrylate-based composite restorations. BACKGROUND:Despite the continued development of resin-based materials, polymerization shrinkage and shrinkage stress still require improvement. A silorane-based monomer system was recently made available for dental restorations. This report refers to the use of this material for making repairs and evaluates the clinical performance of this alternative treatment. MATERIALS AND METHODS:One operator repaired the defective dimethacrylate-based composite resin restorations that were randomly assigned to one of two treatment groups: control (n=50) repair with Adper SE Plus (3M/ESPE) and Filtek P60 Posterior Restorative (3M/ESPE), and test (n=50) repair with P90 System Adhesive Self-Etch Primer and Bond (3M/ESPE) and Filtek P90 Low Shrink Posterior Restorative (3M/ESPE). After one week, restorations were finished and polished. Two calibrated examiners (Kw≥0.78) evaluated all repaired restorations, blindly and independently, at baseline and one year. The parameters examined were marginal adaptation, anatomic form, surface roughness, marginal discoloration, postoperative sensitivity, and secondary caries. The restorations were classified as Alpha, Bravo, or Charlie, according to modified US Public Health Service criteria. Mann-Whitney and Wilcoxon tests were used to compare the groups. RESULTS:Of the 100 restorations repaired in this study, 93 were reexamined at baseline. Dropout from baseline to one-year recall was 11%. No statistically significant differences were found between the materials for all clinical criteria, at baseline or at one-year recall (p>0.05). No statistically significant differences were registered (p>0.05) for each material when compared for all clinical criteria at baseline and at one-year recall. CONCLUSIONS:The hypothesis tested in this randomized controlled clinical trial was accepted. After the one-year evaluations, the silorane-based composite exhibited a similar performance compared with dimethacrylate-based composite when used to make repairs.

journal_name

Oper Dent

journal_title

Operative dentistry

authors

Popoff DA,Santa Rosa TT,Ferreira RC,Magalhães CS,Moreira AN,Mjör IA

doi

10.2341/11-121-C

subject

Has Abstract

pub_date

2012-09-01 00:00:00

pages

E1-10

issue

5

eissn

0361-7734

issn

1559-2863

journal_volume

37

pub_type

杂志文章,随机对照试验
  • Restoration deterioration related to later failure.

    abstract::The purpose of this study was to determine the relationship between the deterioration and the later failure of a very large number of amalgams and anterior resin composites examined over periods of up to 16 years. Assessments were made of the deterioration of various clinical factors or characteristics of the restorat...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Smales RJ,Webster DA

    更新日期:1993-07-01 00:00:00

  • The microtensile bond strength of Fuji IX glass ionomer cement to antibacterial conditioned dentin.

    abstract:INTRODUCTION:Adding antibacterial agents to a dentin conditioner used for a glass ionomer cement (GIC) has been shown to be antibacterial; however, it is not known whether this antimicrobial conditioning agent affects the bond strength to dentin in situ. This study applied GIC to antibacterial conditioned dentin withou...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Botelho MG

    更新日期:2005-05-01 00:00:00

  • Combination of Acetaminophen/Codeine Analgesics Does Not Avoid Bleaching-Induced Tooth Sensitivity: A Randomized, Triple-Blind Two-Center Clinical Trial.

    abstract::Bleaching-induced tooth sensitivity (TS) is highly prevalent. OBJECTIVE:This study aimed to determine if the combination of opioids and nonopioids analgesics (Tylex) may provide a better analgesic effect. METHOD:A triple-blind, parallel, randomized two-center clinical trial was conducted with 105 healthy patients wh...

    journal_title:Operative dentistry

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.2341/17-092-C

    authors: Coppla FM,Rezende M,de Paula E,Farago PV,Loguercio AD,Kossatz S,Reis A

    更新日期:2018-03-01 00:00:00

  • Effect of Ferrule Thickness on Fracture Resistance of Teeth Restored With a Glass Fiber Post or Cast Post.

    abstract:PURPOSE:To investigate the influence of ferrule thickness on fracture resistance after mechanical cycling of teeth restored with different intracanal posts. METHODS AND MATERIALS:One hundred twenty bovine incisor teeth were randomized into six study groups, based on the intracanal post used (fiber post or cast post an...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/18-241-L

    authors: Fontana PE,Bohrer TC,Wandscher VF,Valandro LF,Limberger IF,Kaizer OB

    更新日期:2019-11-01 00:00:00

  • Two-year clinical performance of self-etching adhesive systems in composite restorations of anterior teeth.

    abstract:OBJECTIVE:The aim of this study was to evaluate the two-year clinical performance of Class III, IV, and V composite restorations using a two-step etch-and-rinse adhesive system (2-ERA) and three one-step self-etching adhesive systems (1-SEAs). MATERIAL AND METHODS:Two hundred Class III, IV, and V composite restoration...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/11-397-C

    authors: Barcellos DC,Batista GR,Silva MA,Pleffken PR,Rangel PM,Fernandes VV Jr,Di Nicoló R,Torres CR

    更新日期:2013-05-01 00:00:00

  • Impact of Recently Developed Universal Adhesives on Tensile Bond Strength to Computer-aided Design/Manufacturing Ceramics.

    abstract:OBJECTIVES:The aim of this investigation was to test the tensile bond strength (TBS) between different computer-aided-design/manufacturing (CAD/CAM) ceramics after conditioning using different universal adhesive systems and resin composite cement. METHODS AND MATERIALS:Substrates of four CAD/CAM ceramics-1) VITABLOCS ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/18-017-L

    authors: Liebermann A,Detzer J,Stawarczyk B

    更新日期:2019-07-01 00:00:00

  • Effect of Simulated Mastication on the Surface Roughness and Wear of Machinable Ceramics and Opposing Dental Enamel.

    abstract:OBJECTIVE::Computer aided design-computer aided machining (CAD-CAM) ceramic crowns are replacing ceramo-metal ones due to newly developed mechanical properties and esthetics. To obtain knowledge about their interactions due to polishing and occlusal contacts with the opposing dental enamel specimen, including surface r...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/17-153-L

    authors: Daryakenari G,Alaghehmand H,Bijani A

    更新日期:2019-01-01 00:00:00

  • Curing of pit & fissure sealants using Light Emitting Diode curing units.

    abstract::Light Emitting Diode (LED) curing units are attractive to clinicians, because most are cordless and should create less heat within tooth structure. However, questions about polymerization efficacy have surrounded this technology. This research evaluated the adequacy of the depth of cure of pit & fissure sealants provi...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Platt JA,Clark H,Moore BK

    更新日期:2005-11-01 00:00:00

  • Pulpal response to a new light-cured composite placed in etched glass-ionomer lined cavities.

    abstract::This study evaluated the pulp biocompatability of a new light-cured composite resin which was placed in etched glass-ionomer-lined cavities of monkey teeth. The pulpal response to this material was less than that to zinc-oxide eugenol cement in each observation period. Therefore this material seems to meet acceptable ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Hosoda H,Inokoshi S,Shimada Y,Harnirattisai C,Otsuki M

    更新日期:1991-07-01 00:00:00

  • Technique on restoring sub-gingival cervical lesion.

    abstract::This article outlines an atraumatic isolation approach and a conservative instrumentation sequence, followed by use of a highly viscous, rapid-setting, capsulated glass ionomer cement to manage a difficult deep proximal-cervical Class V lesion. ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Chan DC,Adkins J

    更新日期:2004-05-01 00:00:00

  • Comparison of two-step versus four-step composite finishing/polishing disc systems: evaluation of a new two-step composite polishing disc system.

    abstract:OBJECTIVE:The purpose of this study was to evaluate surface finish and gloss of a two-step composite finishing/polishing (F/P) disc system compared with two multistep systems on five composites. METHODS:Seventy-five disc-shaped composite specimens (D=10.0 mm, 2 mm thick, n=15 per composite) were made of microfill (Dur...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/10-162-L

    authors: da Costa JB,Goncalves F,Ferracane JL

    更新日期:2011-03-01 00:00:00

  • Effect of gender, experience, and value on color perception.

    abstract:STATEMENT OF THE PROBLEM:Precise shade matching can be one of the most difficult tasks for the dentist and some variables may influence the process of shade comparison. PURPOSE OF THE STUDY:This study tested the differences in shade perception between genders, the influence of the observer's clinical experience, and t...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/10-057-C

    authors: Milagres V,Teixeira ML,Miranda ME,Osorio Silva CH,Ribeiro Pinto JR

    更新日期:2012-05-01 00:00:00

  • Novel Microscalpels for Removing Proximal Composite Resin Overhangs on Class II Restorations.

    abstract:INTRODUCTION:Limited access to interdental spaces complicates removal of excess material when placing class II composite resin restorations. Evidence-based recommendations on interproximal finishing are rare. We present novel microscalpels for this indication. The aim of the study was to test their fracture strength an...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/16-012-L

    authors: Wolff D,Schick S,Staehle HJ,Frese C

    更新日期:2017-05-01 00:00:00

  • Microtensile Bond Strength of Composite Cement to Novel CAD/CAM Materials as a Function of Surface Treatment and Aging.

    abstract:OBJECTIVES:To evaluate the effect of different surface treatments on the bond strength to a composite and a polymer-infiltrated ceramic CAD/CAM block after six-month artificial aging. METHODS AND MATERIALS:Two types of CAD/CAM blocks (Cerasmart, GC; Enamic, Vita Zahnfabrik) were cut in slabs of 4-mm thickness, divided...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/15-263-L

    authors: Lise DP,Van Ende A,De Munck J,Vieira L,Baratieri LN,Van Meerbeek B

    更新日期:2017-01-01 00:00:00

  • Enamel Microabrasion and Dental Bleaching on Teeth Presenting Severe-pitted Enamel Fluorosis: A Case Report.

    abstract::The present clinical case report describes the clinical steps of enamel microabrasion associated with dental bleaching to restore severely-pitted fluorosed teeth. The process of removing the fluorotic superficial stains started by using macroabrasion with a water-cooled fine tapered 3195 FF diamond bur. Rubber dam iso...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/18-116-T

    authors: Sundfeld D,Pavani CC,Pini N,Machado LS,Schott TC,Sundfeld RH

    更新日期:2019-11-01 00:00:00

  • Barcoll hardness of different resin-based composites cured by halogen or light emitting diode (LED).

    abstract::The clinical performance of light curing resin composites is greatly influenced by the quality of the light-curing unit (LCU). Halogen LCUs are commonly used for curing composite materials. However, they have some drawbacks. The development of new, blue, super bright light emitting diodes (LED LCU) of 470-nm wavelengt...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Bala O,Uçtasli MB,Tüz MA

    更新日期:2005-01-01 00:00:00

  • Effect of cyclic loading on the microtensile bond strengths of total-etch and self-etch adhesives.

    abstract:OBJECTIVE:To evaluate the effect of mechanical loading on the microtensile bond strength (MTBS) of five adhesive systems to dentin. METHODS:Flat dentin surfaces from human molars were divided into five groups and bonded with total-etch self-priming adhesives (Single Bond, Prime&Bond NT and Prime&Bond XP), two-step sel...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/04-161

    authors: Toledano M,Osorio R,Albaladejo A,Aguilera FS,Tay FR,Ferrari M

    更新日期:2006-01-01 00:00:00

  • Two-year clinical evaluation of IPS Empress II ceramic onlays/inlays.

    abstract::The stronger the ceramic material, the longer the restoration stays in the mouth. The current study evaluated the two-year clinical performance of a strong ceramic system, IPS Empress II, with increased strength on onlay/inlay restorations of molars. Teeth from 35 patients, including three premolars and 32 molars, wer...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/08-97

    authors: Tagtekin DA,Ozyöney G,Yanikoglu F

    更新日期:2009-07-01 00:00:00

  • Bonding ability of paste-paste glass ionomer systems to tooth structure: in vitro studies.

    abstract::This study investigated the effect of nonrinse conditioners (ie, Ketac Nano Primer [KNP] and GC Self Conditioner [SC]) used as substrate pretreatment and their respective paste-paste resin-modified glass-ionomer cement (RMGIC) (ie, Ketac Nano [KN] and Fuji Filling LC [FF]) on microtensile bond strength to dentin and m...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/14-030-L

    authors: Cook NB,Feitosa SA,Patel A,Alfawaz Y,Eckert GJ,Bottino MC

    更新日期:2015-05-01 00:00:00

  • Effect of a chlorhexidine-containing adhesive on dentin bond strength stability.

    abstract:PURPOSE:The present study aimed to investigate a novel adhesive system containing 0.2% chlorhexidine digluconate (CHX) for its ability to improve the stability of the adhesive interface compared with the use of 2% CHX as a therapeutic primer. Furthermore, the study aimed to confirm the inhibitory properties of these CH...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/12-239-L

    authors: Sabatini C

    更新日期:2013-11-01 00:00:00

  • Brushing abrasion of luting cements under neutral and acidic conditions.

    abstract::Four resin based materials (Compolute Aplicap, ESPE; Variolink Ultra, Vivadent; C&B Metabond, Parkell and Panavia 21, Kuraray), two carboxylate cements (Poly-F Plus, Dentsply DeTrey and Durelon Maxicap, ESPE), two glass-ionomer cements (Fuji I, GC and Ketac-Cem Aplicap, ESPE), one resin-modified glass ionomer cement (...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Buchalla W,Attin T,Hellwig E

    更新日期:2000-11-01 00:00:00

  • Effect of beverages on color and translucency of new tooth-colored restoratives.

    abstract::This investigation examined the susceptibility to staining and translucency changes of some new tooth-colored restorative materials after immersion in different beverages. The materials studied were 3M Filtek Z350XT (ZT), 3M Filtek 350XT Flowable Restorative (ZF), Shofu Beautifil Flow Plus (BF), Shofu Beautifil II (B2...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/149027-L

    authors: Tan BL,Yap AU,Ma HN,Chew J,Tan WJ

    更新日期:2015-03-01 00:00:00

  • Effects of secondary curing on indirect posterior composite resins.

    abstract::This study was designed to compare strength, elastic modulus (stiffness), and hardness for five composite resin materials that are used for laboratory-fabricated posterior composite restorations. Ten specimens of each material were processed according to the manufacturer's instructions. Statistical analysis indicated ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Reinhardt JW,Boyer DB,Stephens NH

    更新日期:1994-11-01 00:00:00

  • Efficacy testing of visible-light-curing units.

    abstract::This study evaluated (1) the effect of known reductions in the output of curing lights on the depth of cure of various resins as determined by hardness measurements, and (2) the ability of the clinician to detect reduced light output by use of an explorer to compare the hardness of the top and bottom surfaces of resin...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Fowler CS,Swartz ML,Moore BK

    更新日期:1994-03-01 00:00:00

  • Administration of ascorbic acid to prevent bleaching-induced tooth sensitivity: a randomized triple-blind clinical trial.

    abstract::This study evaluated the effect of ascorbic acid, 500 mg every eight hours, on bleaching-induced tooth sensitivity. A triple-blind, parallel design, and placebo-controlled randomized clinical trial was conducted on 39 adults. The pills (placebo or ascorbic acid) were administered three times per day for 48 hours; the ...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/12-483-C

    authors: de Paula EA,Kossatz S,Fernandes D,Loguercio AD,Reis A

    更新日期:2014-03-01 00:00:00

  • Effect of composite resin contamination with powdered and unpowdered latex gloves on its shear bond strength to bovine dentin.

    abstract::The aim of the present study was to evaluate the effect of composite resin contamination with powdered and unpowdered latex gloves on the shear bond strength of etch-and-rinse and two-step self-etch adhesive systems. Standard flat dentin surfaces were prepared on the facial aspect of 120 bovine incisors and randomly a...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/11-088-L

    authors: Oskoee SS,Navimipour EJ,Bahari M,Ajami AA,Oskoee PA,Abbasi NM

    更新日期:2012-09-01 00:00:00

  • Effect of light activation mode on the incompatibility between one-bottle adhesives and light-cured composites: an in vitro shear bond strength study.

    abstract::This study examined the effect of different light activation modes for light-cured resin-based composites on the shear bond strength to dentin of two one-bottle adhesives with differing acidity. In this experimental study, a flat middle dentin surface was prepared on 110 extracted sound molars using a 600-grit polish ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/08-048-L

    authors: Shafiei F,Saffarpour A,Moradmand M,Alavi AA

    更新日期:2009-09-01 00:00:00

  • Fracture toughness of pin-retained class 4 restorations.

    abstract::Standardized class 4 cavities were prepared in bovine incisors and restored with a microfilled composite resin. The composite restorations were retained either by acid etching technique (AET) alone or by acid etching technique in combination with a self-threading retentive pin. Pins covered with a bonding/opaquer coat...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Attin T,Hellwig E,Hilgers RD,Zimmermann U

    更新日期:1994-05-01 00:00:00

  • The effect of base materials with different elastic moduli on the fracture loads of machinable ceramic inlays.

    abstract::This study investigated the effect of two base materials with different elastic moduli (F2000 and Vitrebond) on the fracture load of machinable ceramic inlays. Standardized MOD cavities were prepared in 18 human maxillary first or second premolars. The teeth were randomly assigned to three groups of six premolars each...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/05-3

    authors: Banditmahakun S,Kuphausuk W,Kanchanavasita W,Kuphasuk C

    更新日期:2006-03-01 00:00:00

  • The effect of additional enamel etching and a flowable composite to the interfacial integrity of Class II adhesive composite restorations.

    abstract::This in vitro study evaluated the interfacial integrity of Class II resin composite restorations. The influence of a flowable composite and additional enamel etching was also evaluated. Deep, saucer-shaped Class II cavities were prepared in the mesial and distal proximal surfaces of 25 extracted human molars and assig...

    journal_title:Operative dentistry

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:

    authors: Belli S,Inokoshi S,Ozer F,Pereira PN,Ogata M,Tagami J

    更新日期:2001-01-01 00:00:00