Degree of Conversion Contributes to Dentin Bonding Durability of Contemporary Universal Adhesives.

Abstract:

CLINICAL RELEVANCE:The degree of conversion of contemporary universal adhesives positively correlates with the bond strength to dentin. The correlation is more marked after thermocycling, suggesting that a high degree of conversion is required for long-term dentin bonding durability. SUMMARY:Purpose: The objectives of this study were to evaluate the micro-tensile bond strength (μTBS) of five contemporary universal adhesives to dentin after 24 hours and thermocycling (TC), to measure their degrees of conversion (DC) and to test the correlation between μTBS and DC.Methods and Materials: Four commercially available universal adhesives, Prime&Bond universal (PBU), Ecosite Bond (EB), G-Premio Bond (GPB), and Clearfil Universal Bond Quick (UBQ), and one experimental adhesive, UBQ without an amide monomer (UBQ-A), were used in this study. For the μTBS test, midcoronal dentin of 50 human molars was exposed, ground using 600-grit SiC paper, and the adhesives were applied according to the manufacturers' instructions. After resin-composite buildup and 24-hour water storage, one-half of the specimens were subjected to 15,000 thermal cycles. The specimens were sectioned into beams and stressed in tension at a crosshead speed of 1 mm/min until failure. The DC of adhesives applied to dentin was evaluated using attenuated total reflectance Fourier-transform infrared spectroscopy immediately after light-curing. All data were statistically analyzed at a significance level of 0.05.Results: The highest μTBSs were obtained with UBQ, UBQ-A, and PBU, which were not significantly different from each other both after 24 hours and TC. The μTBS of GPB was lower compared with the aforementioned adhesives, but significantly only after TC, and the lowest μTBSs were obtained with EB. TC did not affect the μTBSs of UBQ, UBQ-A, and PBU significantly, but a significant decrease was observed with GPB and EB. The highest DC was obtained with PBU and UBQ, followed by 2-hydroxyethyl methacrylate-rich adhesives UBQ-A and EB, which exhibited significantly lower DCs. The DC of GPB could not be determined because the reference peak at 1608 cm-1 was not detected in its spectra. A significant positive correlation was shown between μTBS and DC after 24 hours (r=0.716) and TC (r=0.856).Conclusion: μTBS and DC were positively correlated, more markedly after TC, which suggests that DC may be an important factor for bond durability.

journal_name

Oper Dent

journal_title

Operative dentistry

authors

Tichy A,Hosaka K,Abdou A,Nakajima M,Tagami J

doi

10.2341/19-165-L

subject

Has Abstract

pub_date

2020-09-01 00:00:00

pages

556-566

issue

5

eissn

0361-7734

issn

1559-2863

pii

436330

journal_volume

45

pub_type

杂志文章
  • Influence of carbamide peroxide on the flexural strength of tooth-colored restorative materials: an in vitro study at different environmental temperatures.

    abstract::The current study investigated the influence of carbamide peroxide on the flexural strength of tooth-colored restorative materials at two environmental temperatures. Seven restorative materials were used, including four resin composites (Filtek Z350, Filtek Z250, Synergy Flow and Filtek P60), a polyacid-modified compo...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/09-139-L

    authors: Yu H,Li Q,Lin Y,Buchalla W,Wang Y

    更新日期:2010-05-01 00:00:00

  • Post-gel shrinkage strain and degree of conversion of preheated resin composite cured using different regimens.

    abstract:OBJECTIVES:This study investigated the influence of resin composite preheating temperature, light curing regimen (mode and duration) on post-gel shrinkage strain (PGSS) and degree of conversion (DC) of a restorative resin composite. METHODS:A hybrid resin composite preheated to three different temperatures (37 degrees...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/09-072-L

    authors: El-Korashy DI

    更新日期:2010-03-01 00:00:00

  • Antibacterial activity of various self-etching adhesive systems against oral streptococci.

    abstract::The antibacterial properties of self-etching adhesive systems constitute an important issue in operative dentistry, since viable bacteria can still be present after cavity preparation. The current study evaluated the antibacterial activity of five one-step self-etching adhesives (SEAs) and four self-etching primers (S...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/09-297-L

    authors: Esteves CM,Ota-Tsuzuki C,Reis AF,Rodrigues JA

    更新日期:2010-07-01 00:00:00

  • Lesion Activity Assessment (LAA) in Conjunction With International Caries Detection and Assessment System (ICDAS) for Occlusal Caries Diagnosis in Permanent Teeth.

    abstract:OBJECTIVE:The aim of this study was to investigate the clinical performance and to validate the Lesion Activity Assessment (LAA) in conjunction with the International Caries Detection and Assessment System (ICDAS) for occlusal caries diagnosis in permanent teeth. METHODS:Patients with erupted or partially erupted thir...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/13-332-C

    authors: Cotta F,de Castilho LS,Moreira AN,Paiva SM,Ferreira EF,Ferreira LC,Magalhães CS

    更新日期:2015-09-01 00:00:00

  • Direct Posterior Restorations: A 13-Year Survey of Teaching Trends and Use of Materials.

    abstract:OBJECTIVE::The study aimed to evaluate teaching trends and use of materials in direct posterior restorations during a 13-year period in an Israeli dental school. METHODS::Data registered in computerized files, relating to posterior restorations performed in the student clinic during the past 13 years (2004-2016), were...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/17-361-C

    authors: Zabrovsky A,Mahmoud R,Beyth N,Ben-Gal G

    更新日期:2018-11-01 00:00:00

  • Repair of dimethacrylate-based composite restorations by a silorane-based composite: a one-year randomized clinical trial.

    abstract:PURPOSE:To investigate clinical performance of a low-shrinkage silorane-based composite resin when used for repairing conventional dimethacrylate-based composite restorations. BACKGROUND:Despite the continued development of resin-based materials, polymerization shrinkage and shrinkage stress still require improvement....

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/11-121-C

    authors: Popoff DA,Santa Rosa TT,Ferreira RC,Magalhães CS,Moreira AN,Mjör IA

    更新日期:2012-09-01 00:00:00

  • Structural Integrity Evaluation of Large MOD Restorations Fabricated With a Bulk-Fill and a CAD/CAM Resin Composite Material.

    abstract:AIMS:To evaluate the effect of two composite restorative techniques (direct bulk fill vs indirect CAD/CAM) on the fracture resistance and mode of fracture of extended mesio-occlusal-distal (MOD) cavity preparations. METHODS:Fifty-one sound human mandibular third molars were divided into three groups (n=17). Extended b...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/18-013-L

    authors: Papadopoulos C,Dionysopoulos D,Tolidis K,Kouros P,Koliniotou-Koumpia E,Tsitrou EA

    更新日期:2019-05-01 00:00:00

  • Online Only Articles.

    abstract::On occasion we receive manuscripts that we would like to publish, but do not have the page room to include in the print journal. For the full article, please go to www.jopdentonline.org or enter the provided address into your address bar. ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/1559-2863-43.5.561

    authors:

    更新日期:2018-09-01 00:00:00

  • Two-year clinical comparison of a microfilled and a hybrid resin-based composite in non-carious Class V lesions.

    abstract::The purpose of this double-blind clinical trial was to compare the retention rate in noncarious Class V lesions of two resin-based composite restorative materials with contrasting stiffness. Isolation with retraction cord, pressed paper triangles, and cotton rolls was used to closely mimic the procedures generally use...

    journal_title:Operative dentistry

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:

    authors: Browning WD,Brackett WW,Gilpatrick RO

    更新日期:2000-01-01 00:00:00

  • Effect of Simulated Mastication on the Surface Roughness and Wear of Machinable Ceramics and Opposing Dental Enamel.

    abstract:OBJECTIVE::Computer aided design-computer aided machining (CAD-CAM) ceramic crowns are replacing ceramo-metal ones due to newly developed mechanical properties and esthetics. To obtain knowledge about their interactions due to polishing and occlusal contacts with the opposing dental enamel specimen, including surface r...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/17-153-L

    authors: Daryakenari G,Alaghehmand H,Bijani A

    更新日期:2019-01-01 00:00:00

  • Marginal adaptation of dental composites containing prepolymerized filler.

    abstract::Marginal adaptation to cylindrical dentin preparations of five commercially available dental composites--Charisma, Estelite, Herculite, Pertac, and Silux Plus--and seven experimental dental composites containing prepolymerized filler was evaluated by measurement of the wall-to-wall polymerization contraction gaps. The...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Yukitani W,Hasegawa T,Itoh K,Hisamitsu H,Wakumoto S

    更新日期:1997-11-01 00:00:00

  • Effect of C-factor on microtensile bond strengths of low-shrinkage composites.

    abstract:UNLABELLED:This study evaluated the microtensile bond strength (μ-TBS) of low-shrinkage composites with their corresponding adhesive systems, Filtek Silorane/Silorane adhesive (SIL, 3M ESPE AG, Seefeld, Germany) and Aelite LS/One-Step Plus (AL, BISCO Inc, Schaumburg, IL, USA) in cavities with different C-factors. Filte...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/10-105-L

    authors: El-Sahn NA,El-Kassas DW,El-Damanhoury HM,Fahmy OM,Gomaa H,Platt JA

    更新日期:2011-05-01 00:00:00

  • Clinical evaluation of DIAGNOdent in detection of occlusal caries in newly erupted noncavitated first permanent molars in caries-active children.

    abstract:OBJECTIVE:The aim of this study was to compare the in vivo diagnostic ability of a laser fluorescence system (DIAGNOdent, KaVo, Biberac, Germany) with that of visual inspection in the early detection of occlusal caries in newly erupted noncavitated first permanent molars among caries-active children. MATERIALS AND MET...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/10-309-C

    authors: Duruturk L,Ciftçi A,Baharoğlu S,Oztuna D

    更新日期:2011-07-01 00:00:00

  • Impact of Recently Developed Universal Adhesives on Tensile Bond Strength to Computer-aided Design/Manufacturing Ceramics.

    abstract:OBJECTIVES:The aim of this investigation was to test the tensile bond strength (TBS) between different computer-aided-design/manufacturing (CAD/CAM) ceramics after conditioning using different universal adhesive systems and resin composite cement. METHODS AND MATERIALS:Substrates of four CAD/CAM ceramics-1) VITABLOCS ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/18-017-L

    authors: Liebermann A,Detzer J,Stawarczyk B

    更新日期:2019-07-01 00:00:00

  • Two-year clinical performance of a low-shrinkage composite in posterior restorations.

    abstract:OBJECTIVES:The aim of this study was to compare the two-year clinical performance of three restorative systems in posterior restorations, which included a low-shrinkage composite and both etch-and-rinse and self-etch adhesive strategies. MATERIALS AND METHODS:After signing an informed consent, 25 patients received thr...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/12-364-C

    authors: Baracco B,Perdigão J,Cabrera E,Ceballos L

    更新日期:2013-11-01 00:00:00

  • Impact of Silane-containing Universal Adhesive on the Biaxial Flexural Strength of a Resin Cement/Glass-ceramic System.

    abstract::The aim of this study was to determine whether using a silane-containing universal adhesive as a silane primer in glass-ceramic/resin cement systems affects biaxial flexural strength (BFS) and bonded interface integrity after loading. Glass-ceramic (IPS e.max CAD, Ivoclar/Vivadent, Schaan, Liechtenstein) disc-shaped s...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/17-356-L

    authors: Murillo-Gómez F,Wanderley RB,De Goes MF

    更新日期:2019-03-01 00:00:00

  • Post-gel polymerization contraction of "low shrinkage" composite restoratives.

    abstract::This study compared the post-gel contraction of two "low-shrinkage" composites (InTen-S [IS], Ivoclar-Vivadent; Aelite LS [AL], BISCO Inc) and an ormocer (Admira [AM], Voco) to two conventional mini-filled composites (Renew [RN], BISCO; Z100 [ZO], 3M ESPE). A strain-monitoring device and test configuration were used t...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Yap AU,Soh MS

    更新日期:2004-03-01 00:00:00

  • Online Only Articles.

    abstract::On occasion we receive manuscripts that we would like to publish, but do not have the page room to include in the print journal. For the full article, please go to www.jopdentonline.org or enter the provided address into your address bar. ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/1559-2863-42.6.680

    authors:

    更新日期:2017-11-01 00:00:00

  • Microleakage of compomer restorations in primary teeth after preparation with bur or air abrasion.

    abstract::This study compared the degree of marginal leakage of a compomer in Class V cavities of human primary molars prepared by a conventional dental bur and air abrasion with or without acid etching. Fifty-six non-carious extracted primary molars were randomly divided into four groups (n=14) to be prepared by four technique...

    journal_title:Operative dentistry

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:

    authors: Aysegül O,Nurhan O,Haluk B,Dilek T

    更新日期:2005-03-01 00:00:00

  • Effect of dual cure composite as dentin substitute on marginal integrity of class II open-sandwich restorations.

    abstract::The current study compared the marginal adaptation of Class II open-sandwich restorations with a RMGIC versus a dual-cure composite as dentin substitute. Class II cavities were prepared on 50 extracted human third molars. The teeth were randomly assigned to two groups of 25 teeth to compare one dual cure composite (Mu...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/08-29

    authors: Koubi S,Raskin A,Dejou J,About I,Tassery H,Camps J,Proust JP

    更新日期:2009-03-01 00:00:00

  • Degradation of Computer-aided Design/Computer-aided Manufacturing Composites by Dietary Solvents: An Optical Three-dimensional Surface Analysis.

    abstract:CLINICAL RELEVANCE:Computer-aided design/computer-aided manufacturing (CAD/CAM) composite resins are susceptible to degradation by dietary solvents. Dietary counselling is prudent when placing such CAD/CAM restorations. SUMMARY:This study determined the effect of dietary solvents on the surface roughness (Ra) of direc...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/19-070-L

    authors: Munusamy SM,Yap AU,Ching HL,Yahya NA

    更新日期:2020-07-01 00:00:00

  • Degree of conversion of luting resins around ceramic inlays in natural deep cavities: a micro-Raman spectroscopy analysis.

    abstract::This study evaluated the degree of conversion (%DC) of luting agents around ceramic inlays placed in deep natural cavities. Thirty-six cylindrical Class I cavities (diameter = 4 mm, depth = 4 mm) were prepared in freshly extracted human teeth and randomly divided according to the luting materials used for luting CAD/C...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/10-012-L

    authors: Lohbauer U,Pelka M,Belli R,Schmitt J,Mocker E,Jandt KD,Müller FA

    更新日期:2010-09-01 00:00:00

  • Leakage pathway of Class V cavities restored with different flowable resin composite restorations.

    abstract::This study investigated the leakage pathway of facial and lingual Class V cavities restored with different flowable resin composites bonded with one bonding agent by examining the resin/dentin interface. Forty Class V cavities were etched with 37% phosphoric acid gel; Single Bond dental adhesive was applied, then the ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/07-22

    authors: Awliya WY,El-Sahn AM

    更新日期:2008-01-01 00:00:00

  • Antibacterial activity of dentin bonding systems, resin-modified glass ionomers, and polyacid-modified composite resins.

    abstract::The antibacterial effects of the dentin bonding systems Syntac, ProBOND, Gluma 3-Step, the resin-modified glass ionomers Photac-Fil, Fuji Lining LC, Fuji II LC, and the polyacid-modified composite resins VariGlass, Geristore, and Infinity were evaluated using the cariogenic bacteria S mutans, L salivarius, S sobrinus,...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Meiers JC,Miller GA

    更新日期:1996-11-01 00:00:00

  • Marginal and internal adaptation of bulk-filled Class I and Cuspal coverage direct resin composite restorations.

    abstract::This in vitro study compared the marginal and internal adaptation of bulk-filled Class I and cuspal coverage direct resin composite restorations filled with different types of adhesive restorative systems and different thicknesses of bonding agent. Seventy-two intact, caries-free, freshly extracted human molars were r...

    journal_title:Operative dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.2341/06-157

    authors: Stavridakis MM,Kakaboura AI,Ardu S,Krejci I

    更新日期:2007-09-01 00:00:00

  • Effect of flexural load cycling on microleakage of extended root caries restorations.

    abstract::This study evaluated the microleakage of resin-modified glass ionomer, flowable compomer and flowable resin composite restorations on a Class V cavity of simulated advanced root caries under a flexural load cycling condition. Thirty-six non-carious human maxillary premolars were mounted in cylindrical acrylic resin mo...

    journal_title:Operative dentistry

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:

    authors: Minakuchi S,Munoz CA,Jessop N

    更新日期:2005-03-01 00:00:00

  • Effect of cyclic loading on the microtensile bond strengths of total-etch and self-etch adhesives.

    abstract:OBJECTIVE:To evaluate the effect of mechanical loading on the microtensile bond strength (MTBS) of five adhesive systems to dentin. METHODS:Flat dentin surfaces from human molars were divided into five groups and bonded with total-etch self-priming adhesives (Single Bond, Prime&Bond NT and Prime&Bond XP), two-step sel...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/04-161

    authors: Toledano M,Osorio R,Albaladejo A,Aguilera FS,Tay FR,Ferrari M

    更新日期:2006-01-01 00:00:00

  • The effect of distance and tooth structure on laser fluorescence caries detection.

    abstract::The DIAGNOdent, a device used in caries detection, uses a laser to excite fluorescence from pigments in carious tooth structure. In clinical use assessing occlusal surfaces, distance and tooth structure may separate the instrument's tip from the fluorescent source.The aim of this in vitro study was to examine the effe...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/10-179-L

    authors: Markowitz K,Stenvall RM,Graye M

    更新日期:2012-03-01 00:00:00

  • Relationship between nanoleakage and microtensile bond strength at the resin-dentin interface.

    abstract::To evaluate the correlation between microtensile dentin bond strength (microTBS) and silver ion penetration, two total-etch 3-step and one self-etch 2-step system were investigated. OptiBond FL adhesive was applied to flat occlusal dentin on six non-carious human molars, and a resin composite "crown" was formed in 2 m...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:

    authors: Guzmán-Armstrong S,Armstrong SR,Qian F

    更新日期:2003-01-01 00:00:00

  • Effect of light activation mode on the incompatibility between one-bottle adhesives and light-cured composites: an in vitro shear bond strength study.

    abstract::This study examined the effect of different light activation modes for light-cured resin-based composites on the shear bond strength to dentin of two one-bottle adhesives with differing acidity. In this experimental study, a flat middle dentin surface was prepared on 110 extracted sound molars using a 600-grit polish ...

    journal_title:Operative dentistry

    pub_type: 杂志文章

    doi:10.2341/08-048-L

    authors: Shafiei F,Saffarpour A,Moradmand M,Alavi AA

    更新日期:2009-09-01 00:00:00